Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Res Sq ; 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38410431

RESUMO

We investigated how long-term visual experience with habitual spherical aberration (SA) influences subjective depth of focus (DoF). Nine healthy cycloplegic eyes with habitual SAs of different signs and magnitudes were enrolled. An adaptive optics (AO) visual simulator was used to measure through-focus high-contrast visual acuity after correcting all monochromatic aberrations and imposing +0.5 µm and -0.5 µm SAs for a 6-mm pupil. The positive (n=6) and negative (n=3) SA groups ranged from 0.17 to 0.8 µm and from -1.2 to -0.12 µm for a 6-mm pupil, respectively. For the positive habitual SA group, the median DoF with positive AO-induced SA (2.18D) was larger than that with negative AO-induced SA (1.91D); for the negative habitual SA group, a smaller DoF was measured with positive AO-induced SA (1.81D) than that with negative AO-induced SA (2.09D). The difference in the DoF of individual participants between the induced positive and negative SA groups showed a quadratic relationship with the habitual SA. Subjective DoF tended to be larger when the induced SA in terms of the sign and magnitude was closer to the participant's habitual SA, suggesting the importance of considering the habitual SA when applying the extended DoF method using optical or surgical procedures.

2.
Biomed Opt Express ; 15(3): 1618-1629, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38495697

RESUMO

Extended depth-of-focus (EDoF) intraocular lenses (IOLs) are typically evaluated using commercially available aberrometers. Given the intricate optical design of these IOLs, employing an appropriate wavefront reconstruction method with a sufficient sampling resolution of the aberrometer is crucial. A high-resolution Shack-Hartmann wavefront sensor was developed by magnifying the pupil aperture by a factor of five onto a lenslet array (pitch: 133 µm) and utilizing a full-frame CMOS sensor (24 by 36 mm), resulting in a 26.6 µm sampling resolution. Zonal wavefront reconstruction was used and compared with Zernike-based modal wavefront reconstruction to retain detailed local slope irregularities. Four refractive EDoF IOLs with a power of 20D were examined, and the wavefront difference between the zonal and modal methods, expressed as the root mean squared error (RMSE), remained significant for two of the IOLs up to the 16th-order Zernike spherical aberrations (SAs). Conversely, a negligibly small RMSE was observed for the other two IOLs, as long as the Zernike SAs were higher than the 6th order. The raytracing simulation results from the zonal wavefronts exhibited a stronger correlation with the results of recent optical bench studies than those from the modal wavefronts. The study suggests that certain recent refractive EDoF IOLs possess a complex optical profile that cannot be adequately characterized by limited orders of SAs.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa