Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pacing Clin Electrophysiol ; 47(3): 448-454, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38291877

RESUMO

BACKGROUND: Application of electrocautery to a J-wire is used to perform transseptal puncture (TSP), but with limited evidence supporting safety and efficacy. We conducted a prospective randomized controlled trial to evaluate the safety and efficacy of this technique. METHODS: Two hundred consecutive patients were randomized in a 1:1 fashion to either the ICE-guided electrified J-wire TSP group or a conventional Brockenbrough (BRK) needle TSP group. The TSP was performed with a 0.032″ guidewire under 20 W, "coag" mode and was compared to TSP using the BRK needle. The primary safety endpoints were complications related to TSP. The primary efficacy endpoints included the TSP success rate, the total TSP time, and the total procedure time. RESULTS: All patients complete the procedure safely. The electrified J-wire TSP group had a significantly shorter TSP time than BRK needle TSP group. The total procedure time, number of TSP attempts required to achieve successful LA access, width of the intra-atrial shunt at the end of ablation were similar between the two groups. The incidence of new cerebral infarction detected by MRI were similar between the two groups (3/32 patients in the J-wire TSP group and 2/26 patients in conventional BRK TSP group, p = .82). And no difference in the incidence of residual intra-atrial shunt (4.3% vs. 6%, p = .654) during the 3-month's follow up. CONCLUSION: Using an electrified J-wire for TSP under the guidance of ICE appears to be as safe as and more efficient than conventional BRK needle TSP, which may be especially useful in the era of non-fluoroscopy AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Punções/métodos , Ablação por Cateter/métodos , Ecocardiografia , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 46(12): 1478-1483, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37943004

RESUMO

BACKGROUND: Patients with non-valvular atrial fibrillation (NVAF) and previous stroke have a significantly higher risk of stroke recurrence. This study aimed to examine the safety and efficacy of the LAmbre left atrial appendage occlusion device in NVAF patients with a history of stroke. METHODS: We examined 103 consecutive NVAF patients in 11 Chinese medical centers who had a history of stroke or transient ischemic attacks (TIA) and underwent placement of the LAmbre device. Follow-up was conducted 1, 3, 6, and 12 months after the procedure. The primary endpoints were the incidence of new ischemic or hemorrhagic stroke, TIA, systemic embolism, or cardiac death. Secondary endpoints were serious perioperative or device-related complications and cerebral, gastrointestinal, or other bleeding events requiring transfusion of at least 2 units of packed red blood cells. RESULTS: Mean patient age was 67.63 ± 7.14 years; mean CHA2DS2-VASc score was 4.72 ± 1.18 and mean HAS-BLED score was 1.90 ± 1.00. LAmbre device placement was successful in 101 patients (98.05%). Mean follow-up was 12.2 months. Five patients (4.95%) developed a new pericardial effusion after the procedure; none required treatment. Eighty-six patients (85.15%) exhibited no peri-device leak (PDL). However, 13 (12.8%) had a small (0-3 mm) PDL and two (2.3%) had a moderate PDL (3-5 mm). One recurrent stroke occurred during follow-up (1.1%). No other complications occurred. CONCLUSIONS: This multicenter study shows the safety and efficacy of LAmbre left atrial appendage occlusion for NVAF patients with a history of stroke or TIA.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , AVC Isquêmico/complicações , Apêndice Atrial/cirurgia , Ataque Isquêmico Transitório/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 46(1): 3-10, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36301182

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) technology has been increasingly accepted as an integral part of atrial fibrillation (AF) ablation procedures. It is still unknown whether ICE can routinely replace transesophageal echocardiography (TEE) for routine thrombus screening in non-selective AF patients. OBJECTIVE: To assess whether ICE can routinely replace TEE in screening for left atrial (LA)/left atrial appendage (LAA) thrombus in general patients undergoing catheter ablation for AF. METHODS: A total of 2003 consecutive patients undergoing AF ablation were included. 1155 patients (ICE group) received intra-procedural ICE examination for LA/LAA thrombus screening, while 848 patients (TEE group) received pre-procedure TEE examination. The incidence of thrombus, peri-procedure complications, and hospital efficiency were assessed. RESULTS: The LA and LAA were adequately visualized in all patients. Five patients in the ICE group and 15 patients in the TEE group were found to have LAA thrombus. The incidence of major periprocedural thrombo-embolic events was comparable between two groups (0.2% vs. 0.1%, p = .76), none were due to undetected LA/LAA thrombus. Other major periprocedural complications occurred at similar rates in both groups, while post-procedure fever was less common in the ICE group (12.7% vs. 17.4%, p < .001). Procedure times and hospital length of stay were both shorter in the ICE group (142 min [87-197 min] vs. 150 min [95-205 min], and 3[2-4] day vs. 4[3-5] day, respectively, both p < .001). CONCLUSIONS: ICE can replace TEE for atrial thrombus screening in AF patients undergoing ablation without increased complications. An "ICE replacing TEE" workflow can also reduce the incidence of postoperative fever and improve hospital efficiency.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Cardiopatias , Trombose , Humanos , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Cardiopatias/complicações , Trombose/complicações
4.
Int J Cardiol ; 230: 198-203, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28063668

RESUMO

OBJECTIVES: Vascular calcification is a characteristic feature of atherosclerosis and is considered as an independent predictor of cardiovascular risk. CD137 signaling has previously shown to be involved in atherosclerosis. However, the possible role of CD137 signaling in regulation of vascular calcification has not been reported. In the present study, we investigated the effect of CD137 signaling on vascular calcification in ApoE-/- mice and in vascular smooth muscle cells (VSMCs) of mice. METHODS: Calcium deposition and muscle fibers in vivo or vitro were identified by von-Kossa and Masson's trichrome staining respectively. Alkaline phosphatase (ALP) activity was measured by the ALP assay Kit. The presence of bone morphogenic protein 2 (BMP2) and runt-related transcription factor 2 (Runx2) was detected by real-time PCR, Western blot and immunofluorescence in vitro or vivo. RESULTS: Our data shows that activation of CD137 signaling by intraperitoneal injection of agonist-CD137 antibody increased the areas of vascular calcification. Activation of CD137 signaling also increased the expression of BMP2 and Runx2 in the atherosclerotic plaques. In vitro, activation of CD137 signaling also aggravated VSMC calcification, while blocking CD137 signaling could alleviate agonist-CD137 induced VSMC calcification. In addition, the levels of calcium, BMP2 and Runx2, indicators of calcification, were all significantly elevated in agonist-CD137 group in VSMCs. CONCLUSION: Our data revealed a previously unrecognized role of CD137 signaling in vascular calcification in vivo and vitro and provides a novel target for prevention and treatment of atherosclerosis in the future.


Assuntos
Membro 9 da Superfamília de Receptores de Fatores de Necrose Tumoral/metabolismo , Calcificação Vascular/metabolismo , Animais , Western Blotting , Proteína Morfogenética Óssea 2/biossíntese , Proteína Morfogenética Óssea 2/genética , Cálcio/metabolismo , Diferenciação Celular , Células Cultivadas , Subunidade alfa 1 de Fator de Ligação ao Core/biossíntese , Subunidade alfa 1 de Fator de Ligação ao Core/genética , Modelos Animais de Doenças , Endotélio Vascular/metabolismo , Endotélio Vascular/patologia , Regulação da Expressão Gênica , Imuno-Histoquímica , Camundongos , RNA/genética , Reação em Cadeia da Polimerase em Tempo Real , Transdução de Sinais , Calcificação Vascular/genética , Calcificação Vascular/patologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa