Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38408713

RESUMO

BACKGROUND: New technologies in hip and knee arthroplasty are commonly evaluated using cost-effectiveness analyses and similar economic assessments. There is a wide variation in the methodology of these studies, introducing the potential for bias. The purpose of this study was to evaluate associations between potential financial conflicts of interest (COI) and the outcomes of economic analyses. We hypothesized that authors' COI and industry funding would be associated with conclusions favorable to a new technology. METHODS: Economic analyses making cost-effectiveness or economic implementation claims on patient-specific instrumentation, robotics, and implants used in hip and knee arthroplasty published from 2010 to 2022 were identified. Papers were evaluated to determine if conclusions were favorable to the new technology being studied. Fisher's exact test was utilized to determine the relationship between the presence of COI and an article's conclusions. RESULTS: Of 43 eligible articles, 76.7% were cost-effectiveness analyses, 23.2% were cost analyses, and 67.4% of articles had conclusions favorable to a technology. Of the 29 articles with favorable conclusions, 26 had an author with a financial COI (89.7%), and 14 had industry funding (48.3%). Of the 33 articles with a financial COI, 26 (78.8%) had favorable conclusions, and of the 16 articles with industry funding, 14 (87.5%) had favorable conclusions. Fisher's exact test revealed a statistically significant association between an article having favorable conclusions and the presence of an author's COI or industry funding (odds ratio, 13.5; 95% CI [confidence interval], 2.3 to 79.9; P = .003). CONCLUSIONS: Financial COIs were present in 79.1% of lower extremity arthroplasty economic analyses on technologies and were associated with an article having conclusions favorable to the new technology. Surgeons and decision-makers should be aware of the variability and assumptions in these studies and the potential bias of the conclusions.

2.
J Shoulder Elbow Surg ; 32(9): 1918-1923, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36935077

RESUMO

BACKGROUND: Over the last few decades, several databases and clinical registries have been used to generate studies for orthopedic surgery research including shoulder arthroplasty. Observational database studies present data that are best used to provide information regarding associations between variables but is unable to prove causation. Yet, there remains a tendency for authors to use causal language and conclusive statements in published shoulder arthroplasty literature using such databases. METHODS: We systematically identified administrative database and registry studies on shoulder arthroplasty in 5 orthopedic journals from January 2020 to December 2021. Papers were independently graded by 2 reviewers for the presence, absence, or inconsistent use of causal language throughout the publication. χ2 analyses were conducted to determine the relationship between causality language and article characteristics including the journal of publication. RESULTS: There were 65 eligible articles. According to the reviewers, 67.7% of titles and abstracts were either consistently causal or inconsistently causal in language and inference. On reviewing the full text, 69.2% were found to contain some degree of causal language (38.5% consistently causal, 30.8% inconsistently causal). There were no statistically significant associations between the journal and title and abstract final grading (P = .863) or the journal and full-text grading (P = .726). CONCLUSION: The use of causal language remains highly prevalent in observational database studies related to shoulder arthroplasty. Understanding the limitations of observational database studies is paramount for accurate interpretation of these publications.


Assuntos
Artroplastia do Ombro , Ortopedia , Humanos , Artroplastia do Ombro/efeitos adversos , Artroplastia , Idioma
3.
J Arthroplasty ; 38(5): 945-949, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36521731

RESUMO

BACKGROUND: The use of administrative databases and clinical registries in lower extremity arthroplasty research is growing. Such observational studies are unable to fully control for confounders and cannot establish causality. However, many authors use causal language when describing their aims or findings, potentially misleading readers. We examined the prevalence of causal language and inferences in the lower extremity arthroplasty literature. METHODS: We systematically identified administrative database and registry studies on hip and knee arthroplasty that were published in 4 orthopaedic journals in 2020. Articles were graded independently by two reviewers for the presence of causal language in both the title and abstract and the full text. Chi-squared analyses were conducted to determine the relationship between the causality grading and article characteristics including the journal of publication. RESULTS: Of 116 eligible articles, we classified 79.3% of titles and abstracts as either consistently causal or inconsistently causal, with only 20.7% as consistently noncausal. A total of 40.5% of full texts were consistently causal, 49.1% were inconsistent, and 10.3% were consistently noncausal. Chi-squared analyses revealed no statistically significant association between the title and abstract's grading and the journal (P = .720) nor with the use of a database or registry (P = .716). CONCLUSION: Causal language and inferences were present in 79.3% of titles and abstracts of lower extremity arthroplasty observational database studies published in 2020. The high prevalence of causal language and inferences in the arthroplasty literature may mislead readers.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Ortopedia , Publicações Periódicas como Assunto , Humanos , Prevalência , Idioma
4.
Arthroplast Today ; 22: 101161, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37521736

RESUMO

A 60-year-old man who underwent uncomplicated staged bilateral total hip arthroplasty for femoral head osteonecrosis presented with mechanical catching of his left total hip arthroplasty 3 years after index surgery. Radiographs revealed eccentricity of the left femoral head, concerning the failure of a modern moderately cross-linked polyethylene liner. Catastrophic polyethylene liner failure with significant wear, fragmentation, and femoral head abrasion was noted during revision surgery. The original liner and head were replaced, and the patient has exhibited no complications, pain, or difficulty ambulating 6 months postoperatively. This report highlights one potential novel mechanism for the failure of the Exactech Connexion GXL liner (Exactech Inc., Gainesville, FL), an implant recently reported to have a higher-than-expected failure rate, potentially due to insufficient packaging and increased oxidative processes.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa