Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Transfusion ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38752406

RESUMO

BACKGROUND: Fetal and neonatal exposure to lead is associated with irreversible adverse effects on neural development. There is no reliable threshold for lead effect, so limiting exposure is recommended. A significant correlation has been reported between post-transfusion blood lead level (BLL) in infants and lead levels in transfused RBC units. We measured levels of lead, mercury, and cadmium, in Canadian donor blood to investigate if concerning levels for neonatal transfusion exist. STUDY DESIGN AND METHODS: Whole blood samples from blood donors (n = 2529) were shipped cold within 7 days of donation. All permanent blood donation clinics across Canada were sampled. Twelve of these permanent clinics and 8 mobile clinics with a greater potential for having higher lead or mercury levels were oversampled. Heavy metals were measured by inductively coupled plasma mass spectrometry. RESULTS: Of all donations, 2.2% (lead) and 0.4% (mercury) had levels higher than the recommended thresholds for safe neonatal transfusion. BLLs were higher in males but there was no significant difference in the blood mercury levels of males versus females. Cadmium levels were higher in females. There was a positive correlation between donor age and levels of heavy metals, with lead having the strongest correlation (r = 0.47, p < .0001). Three clinics in close proximity to two lead-producing mines were among the clinics with the highest BLLs. Significantly higher blood mercury levels were observed in coastal clinics. CONCLUSION: Our data on donor blood heavy metal levels supports considering blood transfusion as an exposure source to heavy metals and encourages informed selection of blood units for transfusion to vulnerable groups.

2.
J Infect Dis ; 227(3): 339-343, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36197948

RESUMO

The relationship between antibodies to wild-type severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens and the risk of breakthrough infections is unclear, especially during circulation of the Omicron strain. We investigated the association of anti-spike and anti-receptor binding domain antibody levels and the risk of subsequent breakthrough coronavirus disease 2019 (COVID-19). We included adult paramedics from an observational cohort study who received 2 mRNA vaccines but did not have COVID-19 before the blood collection. Higher postvaccination antibody levels to wild-type SARS-CoV-2 antigens were associated with a reduced risk of COVID-19. Further research into clinical utility of antibody levels, to inform a threshold for protection and timing of boosters, should be prioritized.


Assuntos
COVID-19 , Adulto , Humanos , SARS-CoV-2 , Anticorpos Antivirais , Infecções Irruptivas , Imunização Secundária , Anticorpos Neutralizantes
3.
Clin Chem ; 69(12): 1374-1384, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37947280

RESUMO

BACKGROUND: Physiological changes during pregnancy invalidate use of general population reference intervals (RIs) for pregnant people. The complete blood count (CBC) is commonly ordered during pregnancy, but few studies have established pregnancy RIs suitable for contemporary Canadian mothers. Prospective RI studies are challenging to perform during pregnancy while retrospective techniques fall short as pregnancy and health status are not readily available in the laboratory information system (LIS). This study derived pregnancy RIs retrospectively using LIS data linked to provincial perinatal registry data. METHODS: A 5-year healthy pregnancy cohort was defined from the British Columbia Perinatal Data Registry and linked to laboratory data from two laboratories. CBC and differential RIs were calculated using direct and indirect approaches. Impacts of maternal and pregnancy characteristics, such as age, body mass index, and ethnicity, on laboratory values were also assessed. RESULTS: The cohort contained 143 106 unique term singleton pregnancies, linked to >972 000 CBC results. RIs were calculated by trimester and gestational week. Result trends throughout gestation aligned with previous reports in the literature, although differences in exact RI limits were seen for many tests. Trimester-specific bins may not be appropriate for several CBC parameters that change rapidly within trimesters, including red blood cells (RBCs), some leukocyte parameters, and platelet counts. CONCLUSIONS: Combining information from comprehensive clinical databases with LIS data provides a robust and reliable means for deriving pregnancy RIs. The present analysis also illustrates limitations of using conventional trimester bins during pregnancy, supporting use of gestational age or empirically derived bins for defining CBC normal values during pregnancy.


Assuntos
Hematologia , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Canadá , Contagem de Células Sanguíneas , Valores de Referência
4.
Clin Infect Dis ; 75(1): e888-e891, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-34849655

RESUMO

The optimal dosing interval for severe acute respiratory syndrome coronavirus 2 vaccines remains controversial. In this prospective study, we compared serology results of paramedics vaccinated with mRNA vaccines at the recommended short (17-28 days) vs long (42-49 days) interval. We found that a long dosing interval resulted in higher spike, receptor binding domain, and spike N terminal domain antibody concentrations.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Formação de Anticorpos , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , Estudos Prospectivos , Glicoproteína da Espícula de Coronavírus
5.
Acta Neuropathol ; 141(5): 755-770, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33646358

RESUMO

Age-related neuropathologies progressively impair cognitive abilities by damaging synaptic function. We aimed to identify key components within the presynaptic SNARE (soluble N-ethylmaleimide-sensitive factor attachment protein receptor) machinery associated with cognitive performance and estimate their potential contribution to brain reserve in old age. We used targeted SRM proteomics to quantify amounts of 60 peptides, encoded in 30 different genes, in postmortem specimens of the prefrontal cortex from 1209 participants of two aging studies, with available antemortem cognitive evaluations and postmortem neuropathologic assessments. We found that select (but not all) proteoforms are strongly associated with cognitive function and the burden of Alzheimer's disease (AD) pathology. Specifically, greater abundance of STX1A (but not other syntaxins), SYT12, full-length SNAP25, and the GABAergic STXBP1 variant were robustly associated with better cognitive performance. By contrast, greater abundance of other presynaptic proteins (e.g., STXBP5 or tomosyn, STX7, or SYN2) showed a negative influence on cognition. Regression models adjusting for demographic and pathologic variables showed that altered levels of these protein species explained 7.7% additional between-subject variance in cognition (more than any individual age-related neuropathology in the model), suggesting that these molecules constitute key elements of brain reserve. Network analyses indicated that those peptides associated with brain reserve, and closest to the SNARE fusogenic activity, showed greater centrality measures and were better connected in the network. Validation assays confirmed the selective loss of the STX1A (but not STX1B) isoform in cognitively impaired cases. In rodent and human brains, STX1A was selectively located at glutamatergic terminals. However, in AD brains, STX1A was redistributed adjacent to neuritic pathology, and markedly expressed in astrocytes. Our study provides strong evidence, indicating that select presynaptic proteins are key in maintaining brain reserve. Compromised ability to sustain expression levels of these proteins may trigger synaptic dysfunction and concomitant cognitive impairment.


Assuntos
Encéfalo/metabolismo , Cognição/fisiologia , Reserva Cognitiva/fisiologia , Proteínas SNARE/metabolismo , Idoso , Idoso de 80 Anos ou mais , Animais , Encéfalo/patologia , Feminino , Humanos , Masculino , Proteômica , Ratos , Ratos Sprague-Dawley
6.
Paediatr Child Health ; 26(2): 103-107, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36381677

RESUMO

Objectives: Troponin is a marker of myocardial injury but is not well studied in children. Our primary objective was to ascertain the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional troponin I for the detection of acute myocardial dysfunction in previously healthy children. Our secondary objective was to identify clinical predictors of myocardial dysfunction in the setting of elevated troponin. Study Design: This was a retrospective chart review in a single, paediatric, tertiary care centre of troponin tests performed in all admitted children over a 4-year period. Demographics, symptoms, signs, chest x-ray, ECG, and echocardiogram abnormalities were documented. Myocardial dysfunction was presumed to be absent when the patient had a normal cardiac assessment, with or without echocardiography, and did not re-present. Results: From January 2014 through December 2017, 566 patients had troponin tested as a screen for myocardial injury. Troponin was positive in 38 of 566 cases (6.7%). Myocardial dysfunction was detected in 9 of 566 cases (1.6%). Troponin was elevated in six of nine cases of myocardial dysfunction. The sensitivity of conventional troponin I for detecting acute myocardial dysfunction was 66% (95% confidence interval [CI] 30 to 93%). The specificity was 94% (95% CI 92 to 96%). PPV was 16% (95% CI 6 to 31%) and NPV 99% (95% CI 98 to 100%). An abnormal ECG was more prevalent in patients with a true positive versus a false-positive troponin result (P=0.03). Conclusion: Troponin testing identified few cases of myocardial dysfunction. We found the test to have only 66% sensitivity. Troponin testing as a screen for myocardial injury in children has limited utility.

8.
Clin Chem Lab Med ; 55(12): 1898-1906, 2017 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-28306523

RESUMO

BACKGROUND: Inappropriate laboratory test utilization can result in unnecessary patient testing and increased healthcare costs. While several thyroid function tests are available, thyroid-stimulating hormone (TSH) is recommended as the first-line test for investigating and monitoring thyroid dysfunction. We evaluate thyroid test utilization in Northern Alberta in terms of testing patterns, frequencies, and reflex cutpoints. METHODS: This retrospective study analyzed thyroid test requests from January to December 2014. Each request was designated as appropriate or potentially inappropriate as per clinical practice guidelines and Choosing Wisely recommendations, and the frequencies of each testing pattern were calculated. Sub-analysis was performed to categorize testing patterns based on physician specialty. The number of test requests per patient was determined to assess the appropriateness of testing frequency. Receiver operating characteristic (ROC) curves were generated to define optimal TSH cutpoints for automatic reflex to FT4 testing. RESULTS: Of 752,217 test requests, approximately 10% were potentially inappropriate in terms of testing patterns. Free thyroxine (FT4) and free triiodothyronine (FT3) requested with TSH accounted for 59% of all potentially inappropriate test requests, and 49% of requests from endocrinologists (ENDO) were potentially inappropriate, occurring most frequently among those with less experience. Excessive testing frequencies were observed in 869 patients, accounting for 9382 test requests. Adjustment of our TSH reflex cutpoint would significantly increase specificity for identifying a low FT4 without compromising sensitivity. CONCLUSIONS: This study suggests that questionable testing patterns, excessive testing frequencies, and suboptimal reflexive testing cutpoints contribute to inappropriate thyroid test utilization.


Assuntos
Testes de Função Tireóidea , Tireotropina/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
9.
Crit Rev Clin Lab Sci ; 51(6): 358-78, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25244521

RESUMO

Celiac disease is a complex immune-mediated disorder that is triggered by ingestion of gluten and related proteins in genetically susceptible individuals. Under conditions of increased intestinal permeability, gluten-derived peptides can travel across the intestinal epithelium and undergo deamidation catalyzed by the tissue transglutaminase (TTG) enzyme. This renders them immunogenic in individuals expressing specific human leukocyte antigen (HLA) DQ heterodimers. The resulting immune response is characterized by the production of antibodies against both deamidated gliadin peptides (DGP) and TTG, generation of pro-inflammatory cytokines and activation of cytotoxic T cells. This response damages the intestinal epithelium resulting in the wide range of gastrointestinal and systemic symptoms observed in those with celiac disease. Celiac disease diagnosis has traditionally been based on biopsy and histological examination of the small intestine. While this approach is still considered the gold standard, it is invasive and susceptible to both false-positive and false-negative results. Several laboratory tests have become available to aid in the diagnosis and monitoring of celiac disease, and are the focus of this review. These include serological tests for celiac disease-specific antibodies such as anti-endomysial antibodies, anti-TTG antibodies and anti-DGP antibodies of both the immunoglobulin A (IgA) and immunoglobulin G (IgG) class, genetic tests to elucidate HLA DQ status and ancillary tests such as total IgA. While some have suggested that laboratory tests may replace intestinal biopsy in specific circumstances, others maintain that this procedure remains a critical component of celiac disease diagnosis. We review the analytical methodology, strengths, weaknesses, diagnostic performance and clinical utility of the various laboratory tests for celiac disease. Potential future markers and tests that are now considered obsolete are also discussed. Current clinical practice guidelines for the diagnosis and management of celiac disease from the European Society for Pediatric Gastroenterology, Hepatology and Nutrition, the American College of Gastroenterology and the World Gastroenterology Organisation are summarized, and important differences between these guidelines are highlighted.


Assuntos
Doença Celíaca/diagnóstico , Adulto , Biópsia , Doença Celíaca/imunologia , Doença Celíaca/patologia , Doença Celíaca/fisiopatologia , Criança , Humanos , Modelos Biológicos
10.
Horm Res Paediatr ; 96(3): 332-340, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36030768

RESUMO

INTRODUCTION: Hypervitaminosis D is a relatively uncommon etiology of hypercalcemia. Toxicity is usually caused by very high doses, mostly secondary to erroneous prescription or administration of vitamin D, and less commonly, contaminated foods or manufacturing errors of vitamin D-containing supplements. CASE PRESENTATION: A 16-year-old male, previously healthy, presented with 2-week history of nonspecific symptoms (fatigue, gastrointestinal complaints). Investigations showed acute kidney injury and hypercalcemia (total calcium 3.81 mmol/L). Further diagnostic workup revealed markedly elevated 25-hydroxyvitamin D levels (1,910 nmol/L). He denied taking any vitamin D supplements; however, he reported consumption of creatine and protein supplements. Mass spectrometry analysis of the creatine supplement estimated a vitamin D content of 425,000 IU per serving (100 times the upper tolerable daily dose). A few months later, another previously healthy adolescent presented with severe hypercalcemia and acute kidney injury secondary to hypervitaminosis D. He was also using a creatine supplement, from the same manufacturer brand and lot. Both patients were treated with intravenous hydration, calcitonin, and pamidronate. They maintained normocalcemia after their initial presentation but required low-calcium diets and laboratory testing for months after this exposure. DISCUSSION/CONCLUSION: We present 2 cases of hypervitaminosis D caused by a manufacturing error of a natural health product which did not claim to contain vitamin D. The use of dietary supplements is highly prevalent; this should be incorporated while taking medical history, and considered a potential source of toxicity when an alternative source cannot be found, regardless of the product label.


Assuntos
Injúria Renal Aguda , Hipercalcemia , Masculino , Humanos , Adolescente , Hipercalcemia/induzido quimicamente , Cálcio , Creatina , Vitamina D/efeitos adversos , Vitaminas/efeitos adversos , Suplementos Nutricionais/efeitos adversos , Injúria Renal Aguda/induzido quimicamente
11.
Access Microbiol ; 5(11)2023.
Artigo em Inglês | MEDLINE | ID: mdl-38074111

RESUMO

Background: We examined the 11 month longitudinal antibody decay among two-dose mRNA vaccinees, and identified factors associated with faster decay. Methods: The study included samples from the COVID-19 Occupational Risk, Seroprevalence and Immunity among Paramedics (CORSIP) longitudinal observational study of paramedics in Canada. Participants were included if they had received two mRNA vaccines without prior SARS-CoV-2 infection and provided two blood samples post-vaccination. The outcomes of interest were quantitative SARS-CoV-2 antibody concentrations. We employed spaghetti and scatter plots (with kernel-weighted local polynomial smoothing curve) to describe the trend of the antibody decay over 11 months post-vaccine and fit a mixed effect exponential decay model to examine the loss of immunogenicity and factors associated with antibody waning over time. Results: This analysis included 652 blood samples from 326 adult paramedics. Total anti-spike antibody levels peaked on the twenty-first day (antibody level 9042 U ml-1) after the second mRNA vaccine dose. Total anti-spike antibody levels declined thereafter, with a half-life of 94 [95 % CI: 70, 143] days, with levels plateauing at 295 days (antibody level 1021 U ml-1). Older age, vaccine dosing interval <35 days, and the BNT162b2 vaccine (compared to mRNA-1273 vaccine) were associated with faster antibody decay. Conclusion: Antibody levels declined after the initial mRNA series with a half-life of 94 days, plateauing at 295 days. These findings may inform the timing of booster vaccine doses and identifying individuals with faster antibody decay.

12.
Cureus ; 15(1): e34465, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36874687

RESUMO

OBJECTIVE: Emerging evidence indicates that longer SARS-CoV-2 vaccine dosing intervals results in an enhanced immune response. However, the optimal vaccine dosing interval for achieving maximum immunogenicity is unclear. METHODS: This study included samples from adult paramedics in Canada who received two doses of either BNT162b2 or mRNA-1273 vaccines and provided blood samples six months (170 to 190 days) after the first vaccine dose. The main exposure variable was vaccine dosing interval (days), categorized as "short" (first quartile), "moderate" (second quartile), "long" (third quartile), and "longest" interval (fourth quartile). The primary outcome was total spike antibody concentrations, measured using the Elecsys SARS-CoV-2 total antibody assay. Secondary outcomes included spike and receptor-binding domain (RBD) immunoglobulin G (IgG) antibody concentrations, and inhibition of angiotensin-converting enzyme 2 (ACE-2) binding to wild-type spike protein and several different Delta variant spike proteins. We fit a multiple log-linear regression model to investigate the association between vaccine dosing intervals and the antibody concentrations. RESULTS: A total of 564 adult paramedics (mean age 40 years, SD=10) were included. Compared to "short interval" (≤30 days), vaccine dosing intervals of the long (39-73 days) group (ß= 0.31, 95% Confidence interval (CI): 0.10-0.52) and the longest (≥74 days) group (ß = 0.82. 95% CI: 0.36-1.28) were associated with increased spike total antibody concentration. Compared to the short interval, the longest interval quartile was associated with higher spike IgG antibodies, while the long and longest intervals were associated with higher RBD IgG antibody concentrations. Similarly, the longest dosing intervals increased inhibition of ACE-2 binding to viral spike protein. CONCLUSION: Increased mRNA vaccine dosing intervals longer than 38 days result in higher levels of anti-spike antibodies and ACE-2 inhibition when assessed six months after the first COVID-19 vaccine.

13.
BMJ Open ; 13(6): e071228, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37308276

RESUMO

OBJECTIVE: To determine the SARS-CoV-2 seroprevalence among school workers within the Greater Vancouver area, British Columbia, Canada, after the first Omicron wave. DESIGN: Cross-sectional study by online questionnaire, with blood serology testing. SETTING: Three main school districts (Vancouver, Richmond and Delta) in the Vancouver metropolitan area. PARTICIPANTS: Active school staff enrolled from January to April 2022, with serology testing between 27 January and 8 April 2022. Seroprevalence estimates were compared with data obtained from Canadian blood donors weighted over the same sampling period, age, sex and postal code distribution. PRIMARY AND SECONDARY OUTCOMES: SARS-CoV-2 nucleocapsid antibody testing results adjusted for test sensitivity and specificity, and regional variation across school districts using Bayesian models. RESULTS: Of 1850 school staff enrolled, 65.8% (1214/1845) reported close contact with a COVID-19 case outside the household. Of those close contacts, 51.5% (625/1214) were a student and 54.9% (666/1214) were a coworker. Cumulative incidence of COVID-19 positive testing by self-reported nucleic acid or rapid antigen testing since the beginning of the pandemic was 15.8% (291/1845). In a representative sample of 1620 school staff who completed serology testing (87.6%), the adjusted seroprevalence was 26.5% (95% CrI 23.9% to 29.3%), compared with 32.4% (95% CrI 30.6% to 34.5%) among 7164 blood donors. CONCLUSION: Despite frequent COVID-19 exposures reported, SARS-CoV-2 seroprevalence among school staff in this setting remained no greater than the community reference group. Results are consistent with the premise that many infections were acquired outside the school setting, even with Omicron.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Colúmbia Britânica , Estudos Transversais , Teorema de Bayes , Estudos Soroepidemiológicos , Anticorpos Antivirais
14.
Clin Chem ; 58(9): 1364-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22829312

RESUMO

BACKGROUND: False-positive drug screen results for tetrahydrocannabinol (THC) have been observed. This study investigated the rate of unconfirmed positive screen results in infant and noninfant urine samples and evaluated possible reasons for differences. METHODS: The rate of unconfirmed positive THC screen results for urine samples was determined retrospectively in 2 independent data sets (n = 14,859, reference laboratory; n = 21,807, hospital laboratory) by comparing positive immunoassay-based drug screen results with the associated results of confirmation tests. We then assessed the rate of positive THC screens for samples with varying likelihoods of cannabinoid presence to evaluate the contribution of infant-specific urine constituents to positive results. Finally, a method to detect a THC metabolite (11-hydroxy-Δ9-THC) that occurs in meconium was developed to determine its prevalence in infant urine. RESULTS: Positive screen results failed to confirm more frequently in samples from infants (47%) than in noninfants (0.8%). The hospital laboratory observed a similar discrepancy with a different immunoassay. Infant samples with a high likelihood of containing cannabinoids despite negative confirmatory results had a similar rate of positive screening results (50%, n = 20), whereas all samples with a low likelihood of containing cannabinoids screened negative (n = 23). 11-Hydroxy-Δ9-THC was not detected in any infant urine sample tested (n = 16). CONCLUSIONS: Conventional confirmatory methods for THC may be inappropriate for urine samples from infants. Our results suggest that one or more currently unrecognized THC-associated compounds are responsible for positive THC screen results for infant urine, as opposed to an infant-associated interference.


Assuntos
Canabinoides/urina , Exposição Materna , Detecção do Abuso de Substâncias , Cromatografia Líquida , Feminino , Humanos , Lactente , Recém-Nascido , Gravidez , Espectrometria de Massas em Tandem
15.
Microbiol Spectr ; 10(2): e0270221, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35254166

RESUMO

While mRNA vaccines are highly efficacious against short-term COVID-19, long-term immunogenicity is less clear. We compared humoral immunogenicity between BNT162b2 and mRNA-1273 vaccines 6 months after the first vaccine dose, examining the wild-type strain and multiple Delta-variant lineages. Using samples from a prospective observational cohort study of adult paramedics, we included COVID-19-negative participants who received two BNT162b2 or mRNA-1273 vaccines, and provided a blood sample 170 to 190 days post first vaccine dose. We compared wild-type spike IgG concentrations using the Mann-Whitney U test. We also compared secondary outcomes of: receptor binding domain (RBD) wild-type antibody concentrations, and inhibition of angiotensin-converting enzyme 2 (ACE-2) binding to spike proteins from the wild-type strain and five Delta-variant lineages. We included 571 adults: 475 BNT162b2 (83%) and 96 mRNA-1273 (17%) vaccinees, with a mean age of 39 (SD = 10) and 43 (SD = 10) years, respectively. Spike IgG antibody concentrations were significantly higher (P < 0.0001) for those who received mRNA-1273 (GM 601 BAU/mL [GSD 2.05]) versus BNT162b2 (GM 375 BAU/mL [GSD 2.33) vaccines. Results of RBD antibody comparisons (P < 0.0001), and inhibition of ACE-2 binding to the wild-type strain and all tested Delta lineages (all P < 0.0001), were consistent. Adults who received two doses of mRNA-1273 vaccines demonstrated improved wild-type and Delta variant-specific humoral immunity outcomes at 6 months compared with those who received two doses of the BNT162b2 vaccine. IMPORTANCE The BNT162b2 and mRNA-1273 mRNA SARS-CoV-2 vaccines have demonstrated high efficacy for preventing short-term COVID-19. However, comparative long-term effectiveness is unclear, especially pertaining to the Delta variant. We tested virus-specific antibody responses 6 months after the first vaccine dose and compared individuals who received the BNT162b2 and mRNA-1273 SARS-CoV-2 vaccines. We found that individuals who received the mRNA-1273 vaccine demonstrated superior serological markers at 6 months in comparison with those who received the BNT162b2 vaccine.


Assuntos
COVID-19 , SARS-CoV-2 , Vacina de mRNA-1273 contra 2019-nCoV , Adulto , Anticorpos Antivirais , Vacina BNT162 , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , Estudos Prospectivos , SARS-CoV-2/genética , Vacinas de mRNA
16.
Microbiol Spectr ; 10(1): e0145421, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35196794

RESUMO

SARS-CoV-2 seroprevalence studies may be complicated by vaccination efforts. It is important to characterize the ability of serology methods to correctly distinguish prior infection from postvaccination seroreactivity. We report the performance of the Meso Scale Discovery (MSD) V-PLEX COVID-19 Coronavirus Panel 2 IgG assay. Using serum samples from a prospective cohort of paramedics, we calculated the performance of the V-PLEX nucleocapsid ("N") assay to classify prior SARS-CoV-2 infections, defined as a (i) history of a positive SARS-CoV-2 PCR test or (ii) positive serology results using the Roche Elecsys total nucleocapsid anti-SARS-Cov-2 assay. We calculated sensitivity and specificity at the optimal threshold (defined by the highest Youden index). We compared subgroups based on vaccination status, and between models that excluded prior infections 3 to 12 months before sample collection. Of 1119 participants, 914 (81.7%) were vaccinated and 60 (5.4%) had evidence of a preceding SARS-CoV-2 infection. Overall and within vaccinated and unvaccinated subgroups, the optimal thresholds were 828 AU/mL, 827 AU/mL, and 1324 AU/mL; with sensitivities of 0.95 (95% CI: 0.94 to 0.96), 0.95 (0.94 to 0.96), 0.94 (0.92 to 0.96) and specificities of 0.88 (0.86 to 0.90), 0.87 (0.85 to 0.89), and 0.94 (0.89 to 0.98), respectively. N-assay specificity was significantly better in unvaccinated (versus vaccinated) individuals (P = 0.005). Overall optimal thresholds based on the AUC values were higher for samples from unvaccinated participants, especially when examining infections within the preceding 9 months (5855 versus 1704 AU/mL). Overall, V-PLEX nucleocapsid assay cutoff values were higher among unvaccinated individuals. Specificity was also significantly higher among unvaccinated individuals. Different thresholds were required to achieve optimal test performance, especially for detecting SARS-CoV-2 infections within the preceding 9 months. IMPORTANCE Among a cohort of adult paramedics in Canada, we investigated the performance of nucleocapsid (N) antibody detection (measured with a V-PLEX assay) to identify previous COVID-19 infections and compared differences among vaccinated and unvaccinated. Our data indicate that vaccinated and unvaccinated groups require different thresholds to achieve optimal test performance, especially for detecting COVID-19 within the preceding 9 months. Overall, specificity was significantly higher among unvaccinated, compared to vaccinated individuals.


Assuntos
Teste Sorológico para COVID-19/normas , Vacinas contra COVID-19/administração & dosagem , COVID-19/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Pessoal Técnico de Saúde , COVID-19/prevenção & controle , Teste Sorológico para COVID-19/métodos , Vacinas contra COVID-19/classificação , Canadá , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
17.
Open Forum Infect Dis ; 9(8): ofac349, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35937649

RESUMO

Nucleocapsid serological assay sensitivity to identify severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections among vaccinees and for Omicron cases is unclear. In this prospective study, the Elecsys nucleocapsid assay was 89% sensitive in identifying SARS-CoV-2 infections 14-607 days pre-blood collection. Sensitivity was similar when comparing by vaccination status, and in Omicron (vs pre-Omicron) cases.

18.
Microbiol Spectr ; 10(5): e0131522, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36121252

RESUMO

SARS-CoV-2 anti-spike antibody concentrations and angiotensin converting enzyme-2 (ACE-2) inhibition have been used as surrogates to live viral neutralizing antibody titers; however, validity among vaccinated individuals is unclear. We tested the correlation of these measures among vaccinated participants, and examined subgroups based on duration since vaccination and vaccine dosing intervals. We analyzed 120 samples from two-dose mRNA vaccinees without previous COVID-19. We calculated Spearman correlation coefficients between wild-type viral neutralizing antibody titers and: anti-spike (total and IgG), anti-receptor-binding-domain (RBD), and anti-N-terminal-domain (NTD) antibodies; and ACE-2 binding by RBD. We performed three secondary analyses, dichotomizing samples by the first vaccination-to-blood collection interval, second vaccination-to-blood collection interval, and by the vaccine dosing interval (all groups divided by the median), and compared correlation coefficients (Fisher's Z test). Of 120 participants, 63 (53%) were women, 91 (76%) and 29 (24%) received BNT162b2 and mRNA-1273 vaccines, respectively. Overall, live viral neutralization was correlated with anti-spike total antibody (correlation coefficient = 0.80), anti-spike IgG (0.63), anti-RBD IgG (0.62), anti-NTD IgG (0.64), and RBD ACE2 binding (0.65). Samples with long (>158 days) first vaccination-to-blood collection and long (>71 days) second vaccination-to-blood collection intervals demonstrated higher correlation coefficients, compared with short groups. When comparing cases divided by short (≤39 days) versus long vaccine dosing intervals, only correlation with RBD-ACE-2 binding inhibition was higher in the long group. Among COVID-negative mRNA vaccinees, anti-spike antibody and ACE-2 inhibition concentrations are correlated with live viral neutralizing antibody titers. Correlation was stronger among samples collected at later durations from vaccination. IMPORTANCE Live viral neutralizing antibody titers are an accepted measure of immunity; however, testing procedures are labor-intensive. COVID-19 antibody and angiotensin converting enzyme-2 (ACE-2) levels have been used as surrogates to live viral neutralizing antibody titers; however, validity among vaccinated individuals is unclear. Using samples from 120 two-dose mRNA vaccinees without previous COVID-19, we found that live viral neutralization was correlated with COVID-19 antibody and ACE2 binding levels. When grouping samples by the time interval between vaccination and sample blood collection, samples collected over 158 days after the first vaccine and over 71 days from the second vaccine demonstrated stronger correlation between live viral neutralization titers and both antibody and ACE2 levels, in comparison to those collected earlier.


Assuntos
Enzima de Conversão de Angiotensina 2 , Anticorpos Neutralizantes , Vacinas contra COVID-19 , COVID-19 , Feminino , Humanos , Masculino , Anticorpos Antivirais , Vacina BNT162 , COVID-19/prevenção & controle , Imunoglobulina G , SARS-CoV-2 , Vacinação , Vacinas contra COVID-19/imunologia
19.
Microbiol Spectr ; 10(2): e0140521, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35266818

RESUMO

We investigate the diagnostic accuracy and predictive value of finger prick capillary dried blood spot (DBS) samples tested by a quantitative multiplex anti-immunoglobulin G (IgG) assay to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies after infection or vaccination. This cross-sectional study involved participants (n = 6,841) from several serological surveys conducted in nonhospitalized children and adults throughout 2020 and 2021 in British Columbia (BC), Canada. Analysis used paired DBS and serum samples from a subset of participants (n = 642) prior to vaccination to establish signal thresholds and calculate diagnostic accuracy by logistic regression. Discrimination of the logistic regression model was assessed by receiver operator curve (ROC) analysis in an n = 2,000 bootstrap of the paired sample (n = 642). The model was cross-validated in a subset of vaccinated persons (n = 90). Unpaired DBS samples (n = 6,723) were used to evaluate anti-IgG signal distributions. In comparison to paired serum, DBS samples from an unvaccinated population possessed a sensitivity of 79% (95% confidence interval [95% CI]: 58 to 91%) and specificity of 97% (95% CI: 95 to 98%). ROC analysis found that DBS samples accurately classify SARS-CoV-2 seroconversion at an 88% percent rate (area under the curve [AUC] = 88% [95% CI: 80 to 95%]). In coronavirus disease 2019 (COVID-19) vaccine dose one or two recipients, the sensitivity of DBS testing increased to 97% (95% CI: 83 to 99%) and 100% (95% CI: 88 to 100%). Modeling found that DBS testing possesses a high positive predictive value (98% [95% CI: 97 to 98%]) in a population with 75% seroprevalence. We demonstrate that DBS testing should be considered to reliably detect SARS-CoV-2 seropositivity from natural infection or vaccination. IMPORTANCE Dried blood spot samples have comparable diagnostic accuracy to serum collected by venipuncture when tested by an electrochemiluminescent assay for antibodies and should be considered to reliably detect seropositivity following SARS-CoV-2 infection and/or vaccination.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Anticorpos Antivirais , Formação de Anticorpos , COVID-19/diagnóstico , Vacinas contra COVID-19 , Criança , Estudos Transversais , Humanos , Imunoglobulina G , Estudos Soroepidemiológicos
20.
BMJ Open ; 12(4): e057846, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35383082

RESUMO

OBJECTIVES: Few studies reported COVID-19 cases in schools during the 2020/21 academic year in a setting of uninterrupted in-person schooling. The main objective was to determine the SARS-CoV-2 seroprevalence among school staff in Vancouver public schools. DESIGN: Cumulative incident COVID-19 cases among all students and school staff based on public health data, with an embedded cross-sectional serosurvey among a school staff sample that was compared to period, age, sex and geographical location-weighted data from blood donors. SETTING: Vancouver School District (British Columbia, Canada) from kindergarten to grade 12. PARTICIPANTS: Active school staff enrolled from 3 February to 23 April 2021 with serology testing from 10 February to 15 May 2021. MAIN OUTCOME MEASURES: SARS-CoV-2 seroprevalence among school staff, based on spike (S)-based (unvaccinated staff) or N-based serology testing (vaccinated staff). RESULTS: Public health data showed the cumulative incidence of COVID-19 among students attending in-person was 9.8 per 1000 students (n=47 280), and 13 per 1000 among school staff (n=7071). In a representative sample of 1689 school staff, 78.2% had classroom responsibilities, and spent a median of 17.6 hours in class per week (IQR: 5.0-25 hours). Although 21.5% (363/1686) of surveyed staff self-reported close contact with a COVID-19 case outside of their household (16.5% contacts were school-based), 5 cases likely acquired the infection at school based on viral testing. Sensitivity/Specificity-adjusted seroprevalence in 1556/1689 staff (92.1%) was 2.3% (95% CI: 1.6% to 3.2%), comparable to a sex, age, date and residency area-weighted seroprevalence of 2.6% (95% CI: 2.2% to 3.1%) among 5417 blood donors. CONCLUSION: Seroprevalence among staff was comparable to a reference group of blood donors from the same community. These data show that in-person schooling could be safely maintained during the 2020/21 school year with mitigation measures, in a large school district in Vancouver, Canada.


Assuntos
COVID-19 , SARS-CoV-2 , Colúmbia Britânica/epidemiologia , COVID-19/epidemiologia , Estudos Transversais , Humanos , Estudos Soroepidemiológicos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa