Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Pharm ; 338(1-2): 35-42, 2007 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-17289314

RESUMO

It is well known that cyclodextrins are able to extract lipids constituting membranes, increasing their fluidity and permeability. This behaviour towards biological membranes is directly linked to the toxicological effects of methylated cyclodextrins. However, confusion is currently made in the literature between the different methylated cyclodextrin derivatives. Moreover, a new methylated cyclodextrin derivative recently occurred in the market, the Crysmeb. We wanted to compare and understand the effect of the most currently used cyclodextrins on a model membrane. We studied the influence of natural cyclodextrins (betaCD and gammaCD), methylated derivatives (2,6-dimethyl-betaCD (Dimeb), 2,3,6-trimethyl-betaCD (Trimeb) and randomly methylated-betaCD (Rameb), as well as the new derivative Crysmeb), hydroxypropylated derivatives (HPbetaCD of different substitution degrees and HPgammaCD) and the sulfobutylated derivative (SBEbetaCD) on the release of a fluorescent marker encapsulated in the inner cavity of liposomes. It was shown that the observed effect on calcein release can be directly related to the affinity of cyclodextrins for both lipid components of liposomes, cholesterol and phosphatidylcholine. From this relationship, we were able to determine, for each cyclodextrin, a theoretical concentration giving rise to 50% or 100% calcein release. This theoretical concentration was confirmed experimentally. We have also showed that cyclodextrins which provoke calcein release also induce large structure modifications of liposomes.


Assuntos
Ciclodextrinas/química , Lipídeos/química , Lipossomos/química , Colesterol/química , Fluoresceínas/administração & dosagem , Fluoresceínas/química , Solubilidade
2.
J Pharm Biomed Anal ; 43(3): 910-9, 2007 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-17023137

RESUMO

The inclusion complexes of tagitinin C with beta-, 2,6-di-O-methyl-beta- and gamma-cyclodextrin (CyD) was investigated in aqueous medium. The stoichiometric ratios and stability constants (K(f)) which describe the extent of formation of the complexes have been determined by UV spectroscopy and direct current tast polarography (DC(tast)), respectively. For each complex, a 1:1 molar ratio was formed in solution and the trend of stability constants was K(f) (2,6-di-O-methyl-beta-CyD)>K(f) (gamma-CyD)>K(f) (beta-CyD). The effect of molecular encapsulation on the photochemical conversion of tagitinin C was evaluated. No significant protection efficacy was noticed with beta- and gamma-CyD for the complexed drug with the respect to the free one. On the other hand, the photochemical conversion rate was slowed in presence of 2,6-di-O-methyl-beta-CyD. Data from (1)H NMR and ROESY experiments provided a clear evidence of formation of inclusion complexes. The lactone, the ester and the unsaturated ketone parts of tagitinin C inserted into the wide rim of the CyDs torus. These experimental results were confirmed by the molecular modeling using semiempirical Austin Model 1 (AM1) method.


Assuntos
Ciclodextrinas/química , Sesquiterpenos/química , Fenômenos Químicos , Físico-Química , Composição de Medicamentos , Eletroquímica , Indicadores e Reagentes , Espectroscopia de Ressonância Magnética , Modelos Moleculares , Fotoquímica , Polarografia , Espectrofotometria Ultravioleta , Água
3.
Talanta ; 71(2): 911-7, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071394

RESUMO

Supercritical fluid extraction (SFE) with carbon dioxide as extraction medium was on-line coupled to a FT-IR spectrometer equipped with a Mercury Cadmium Telluride (MCT) detector using a tailor-made high-pressure fibre optic flow cell. This method was optimised and developed for the monitoring in real time and the quantification of dynamic extractions of tagitinin C from Tithonia diversifolia leaves. In order to demonstrate the method ability to allow the direct quantification of tagitinin C in the extract medium the standard addition method was used. The area integration of curves obtained by plotting the absorbance of the highly specific C=O stretching vibration at 1668cm(-1) versus time (i.e. extractograms) was used as instrumental response. The SFE/FT-IR process was successfully validated using the accuracy profile as decision tool. On this basis, a linear regression model was chosen for the calibration curve. The relative standard deviation for repeatability and intermediate precision were between 0.8 and 3.1 %, respectively. Moreover, the method was found to be accurate as the two-sided 95% beta-expectation tolerance interval did not exceed the acceptance limits of 85 and 115% on the analytical range investigated (500-2500microg of added amount of tagitinin C). The proposed method allowed the non-destructive extraction of tagitinin C and its on-line quantitative determination in less than 25min thus facilitating the subsequent experiments or the pharmacological studies performed on this compound.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa