Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 96(32): 12966-12972, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-38684213

RESUMO

A methodology based on the use of asymmetrical flow field-flow fractionation (AF4) coupled to ICP-MS with size fraction-targeted isotope dilution analysis (IDA) has been developed, validated, and applied for the first time to determine the mass fraction of nanoscale silica (SiO2). For this purpose, 29Si-enriched SiO2 nanoparticles, to be used as an IDA spike/internal standard, were synthesized and characterized in-house. Double IDA was used to quantify an aqueous suspension of Stöber silica particles of similar characteristics to those of the 29SiO2 nanoparticle (NP) spike using a representative test material of natural Si isotopic composition as the calibrant. For fumed SiO2 NP in a highly complex food matrix, a methodology based on single IDA with AF4/ICP-MS using the same 29SiO2 NP spike was developed and validated. Relative expanded measurement uncertainties (k = 2) of 4% (double IDA) and 8% (single IDA) were achieved for nanoscale silica mass fractions of 5143 and 107 mg kg-1 in water suspension and food matrix, respectively. To assess the accuracy of AF4/ICP-IDMS for the characterization of SiO2 NP in a food matrix, standard addition measurements on samples spiked with Aerosil AF200, also in-house characterized for Si mass fraction, were undertaken, with an average recovery of 95.6 ± 4.1% (RSD, n = 3) obtained. The particle-specific IDA data obtained for both SiO2 NP-containing samples were also compared with that of post-AF4 channel external calibration using inorganic Si standards. The mass fractions obtained by IDA agreed well with those obtained by external calibration within their associated measurement uncertainties.

2.
Nanotechnology ; 35(38)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38861978

RESUMO

Biomedical analytical applications, as well as the industrial production of high-quality nano- and sub-micrometre particles, require accurate methods to quantify the absolute number concentration of particles. In this context, small-angle x-ray scattering (SAXS) is a powerful tool to determine the particle size and concentration traceable to the Système international d'unités (SI). Therefore, absolute measurements of the scattering cross-section must be performed, which require precise knowledge of all experimental parameters, such as the electron density of solvent and particles, whereas the latter is often unknown. Within the present study, novel SAXS-based approaches to determine the size distribution, density and number concentrations of sub-micron spherical silica particles with narrow size distributions and mean diameters between 160 nm and 430 nm are presented. For the first-time traceable density and number concentration measurements of silica particles are presented and current challenges in SAXS measurements such as beam-smearing, poorly known electron densities and moderately polydisperse samples are addressed. In addition, and for comparison purpose, atomic force microscopy has been used for traceable measurements of the size distribution and single particle inductively coupled plasma mass spectrometry with the dynamic mass flow approach for the accurate quantification of the number concentrations of silica particles. The possibilities and limitations of the current approaches are critically discussed in this study.

3.
Anal Chem ; 95(5): 2757-2764, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36701560

RESUMO

Surface-enhanced Raman scattering (SERS) is widely explored for the elucidation of underlying mechanisms behind biological processes. However, the capability of absolute quantitation of the number of nanoparticles from the SERS response remains a challenge. Here, we show for the first time the development of a new 2D quantitation model to allow calibration of the SERS response against the absolute concentration of SERS nanotags, as characterized by single particle inductively coupled plasma mass spectrometry (spICP-MS). A novel printing approach was adopted to prepare gelatin-based calibration standards containing the SERS nanotags, which consisted of gold nanoparticles and the Raman reporter 1,2-bis(4-pyridyl)ethylene. spICP-MS was used to characterize the Au mass concentration and particle number concentration of the SERS nanotags. Results from laser ablation inductively coupled plasma time-of-flight mass spectrometry imaging at a spatial resolution of 5 µm demonstrated a homogeneous distribution of the nanotags (between-line relative standard deviation < 14%) and a linear response of 197Au with increasing nanotag concentration (R2 = 0.99634) in the printed gelatin standards. The calibration standards were analyzed by SERS mapping, and different data processing approaches were evaluated. The reported calibration model was based on an "active-area" approach, classifying the pixels mapped as "active" or "inactive" and calibrating the SERS response against the total Au concentration and the particle number concentration, as characterized by spICP-MS. This novel calibration model demonstrates the potential for quantitative SERS imaging, with the capability of correlating the nanoparticle concentration to biological responses to further understand the underlying mechanisms of disease models.

4.
Langmuir ; 35(14): 4927-4935, 2019 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-30869903

RESUMO

Measuring the number concentration of colloidal nanoparticles (NPs) is critical for assessing reproducibility, enabling compliance with regulation, and performing risk assessments of NP-enabled products. For nanomedicines, their number concentration directly relates to their dose. However, the lack of relevant reference materials and established traceable measurement approaches make the validation of methods for NP number concentration difficult. Furthermore, commercial products often exhibit agglomeration, but guidelines for dealing with nonideal samples are scarce. We have compared the performance of five benchtop measurement methods for the measurement of colloidal number concentration in the presence of different levels of agglomeration. The methods are UV-visible spectroscopy, differential centrifugal sedimentation, dynamic light scattering, particle tracking analysis, and single-particle inductively coupled plasma mass spectrometry. We find that both ensemble and particle-by-particle methods are in close agreement for monodisperse NP samples and three methods are within 20% agreement for agglomerated samples. We discuss the sources of measurement uncertainties, including how particle agglomeration affects measurement results. This work is a first step toward validation and expansion of the toolbox of methods available for the measurement of real-world NP products.

5.
Anal Chem ; 87(11): 5482-5, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-25970520

RESUMO

We propose for the first time methodology for the determination of a number-based concentration of silica (SiO2) nanoparticles (NP) in biological serum using nanoparticle tracking analysis (NTA) as the online detector for asymmetric flow field-flow fractionation (AF4). The degree of selectivity offered by AF4 was found necessary to determine reliably number-based concentration of the measured NP in the complex matrix with a relative measurement error of 5.1% (as relative standard deviation, n = 3) and without chemical sample pretreatment. The simultaneous online coupling to other size and concentration detectors, such as multiangle light scattering (MALS) and ICPMS, for the measurement of the same NP suspension, was used to confirm the particle size determined with NTA and the equivalent particle number determined by AF4/NTA, respectively. The size- and number-based concentration data obtained by independent techniques were in a good agreement. The developed methodology can easily be extended to other types of particles or particle suspensions and other complex matrices provided that the particle size is above the limit of detection for NTA.


Assuntos
Técnicas de Química Analítica/métodos , Nanopartículas/análise , Soro/química , Dióxido de Silício/análise , Animais , Bovinos , Peso Molecular , Sistemas On-Line , Tamanho da Partícula
6.
Anal Bioanal Chem ; 406(16): 3919-27, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24817355

RESUMO

This work represents a first systematic approach to the size-based elemental quantification and size estimation of metal(loid) oxide nanoparticles such as silica (SiO2) in a real food matrix using asymmetric flow field-flow fractionation coupled online with inductively coupled plasma mass spectrometry (ICP-MS) and multi-angle light scattering (MALS) and offline with transmission electron microscopy (TEM) with energy-dispersive X-ray analysis (EDAX). Coffee creamer was selected as the model sample since it is known to contain silica as well as metal oxides such as titania at the milligramme per kilogramme levels. Optimisation of sample preparation conditions such as matrix-to-solvent ratio, defatting with organic solvents and sonication time that may affect nanoparticle size and size distribution in suspensions was investigated. Special attention was paid to the selection of conditions that minimise particle transformation during sample preparation and analysis. The coffee creamer matrix components were found to stabilise food grade SiO2 particles in comparison with water suspensions whilst no significant effect of defatting using hexane was found. The use of sample preparation procedures that mimic food cooking in real life was also investigated regarding their effect on particle size and particle size distribution of silica nanoparticles in the investigated food matrix; no significant effect of the water temperature ranging from ambient temperature to 60 °C was observed. Field-flow fractionation coupled to inductively coupled plasma-mass spectrometry (FFF-ICP-MS) analysis of extracts of both unspiked coffee creamer and coffee creamer spiked with food grade silicon dioxide, using different approaches for size estimation, enabled determination of SiO2 size-based speciation. Element-specific detection by ICP-MS and post-FFF calibration with elemental calibration standards was used to determine the elemental composition of size fractions separated online by FFF. Quantitative data on mass balance is provided for the size-based speciation of the investigated inorganic nano-objects in the complex matrix. The combination of FFF with offline fractionation by filtration and with detection by ICP-MS and TEM/EDAX has been proven essential to provide reliable information of nanoparticle size in the complex food matrix.


Assuntos
Aditivos Alimentares/química , Espectrometria de Massas/métodos , Nanopartículas/química , Dióxido de Silício/química , Aditivos Alimentares/isolamento & purificação , Espectrometria de Massas/instrumentação , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , Dióxido de Silício/isolamento & purificação
7.
Discov Nano ; 19(1): 14, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38252361

RESUMO

The concentration of cell-type specific extracellular vesicles (EVs) is a promising biomarker for various diseases. However, concentrations of EVs measured by optical techniques such as flow cytometry (FCM) or particle tracking analysis (PTA)  in clinical practice are incomparable. To allow reliable and comparable concentration measurements suitable reference materials (RMs) and SI-traceable (SI-International system of units) methods are required. Hollow organosilica beads (HOBs) are promising RM candidates for concentration measurements of EVs based on light scattering, as the shape, low refractive index, and number concentration of HOBs are comparable to EVs of the respective size range that can be detected with current optical instrumentation. Here, we present traceable methods for measuring the particle size distribution of four HOB types in the size range between 200 and 500 nm by small-angle X-ray scattering (SAXS) and atomic force microscopy (AFM), as well as the number concentration by single-particle inductively coupled plasma mass spectrometry (spICP-MS). Based on the size and shape results, traceable reference values were obtained to additionally determine the refractive index of the shell of the HOB samples by FCM. Furthermore, the estimated refractive indexes of the HOBs plausibly agree with the refractive indexes of EVs of corresponding size. Due to their narrow size distribution and their similar shape, and low refractive index, all HOB samples studied are suitable RM candidates for calibration of the measured sample volume by optical methods within the photon wavelength range used, and thus for calibration of number concentration measurements of EVs in the size range indicated. This was confirmed as the number concentration values obtained by PTA and two independent flow cytometric measurements agreed with the concentration reference values obtained by two independent spICP-MS measurements within the calculated uncertainty limits.

8.
Nanomedicine (Lond) ; 18(3): 233-258, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37078419

RESUMO

Background: Modern medicine requires intensive research to find new diagnostic and therapeutic solutions. Recently, upconverting nanoparticles (UCNPs) doped with lanthanide ions have attracted significant attention. Methods: The efficient internalization of UCNPs by cells was confirmed, and their precise cellular localization was determined by electron microscopy and confocal studies. Results: UCNPs colocalized only with specific organelles, such as early endosomes, late endosomes and lysosomes. Furthermore, experiments with chemical inhibitors confirmed the involvement of endocytosis in UCNPs internalization and helped select several mechanisms involved in internalization. Exposure to selected UCNPs concentrations did not show significant cytotoxicity, induction of oxidative stress or ultrastructural changes in cells. Conclusion: This study suggests that UCNPs offer new diagnostic options for biomedical infrared imaging.


Assuntos
Elementos da Série dos Lantanídeos , Nanopartículas , Distribuição Tecidual , Elementos da Série dos Lantanídeos/química , Diagnóstico por Imagem , Nanopartículas/química
9.
Nanomaterials (Basel) ; 13(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36985886

RESUMO

The study described in this paper was conducted in the framework of the European nPSize project (EMPIR program) with the main objective of proposing new reference certified nanomaterials for the market in order to improve the reliability and traceability of nanoparticle size measurements. For this purpose, bimodal populations as well as complexly shaped nanoparticles (bipyramids, cubes, and rods) were synthesized. An inter-laboratory comparison was organized for comparing the size measurements of the selected nanoparticle samples performed with electron microscopy (TEM, SEM, and TSEM), scanning probe microscopy (AFM), or small-angle X-ray scattering (SAXS). The results demonstrate good consistency of the measured size by the different techniques in cases where special care was taken for sample preparation, instrument calibration, and the clear definition of the measurand. For each characterization method, the calibration process is described and a semi-quantitative table grouping the main error sources is proposed for estimating the uncertainties associated with the measurements. Regarding microscopy-based techniques applied to complexly shaped nanoparticles, data dispersion can be observed when the size measurements are affected by the orientation of the nanoparticles on the substrate. For the most complex materials, hybrid approaches combining several complementary techniques were tested, with the outcome being that the reliability of the size results was improved.

10.
Small ; 8(1): 122-30, 2012 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-22102541

RESUMO

The interactions between noncancerous, primary endothelial cells and gold nanoparticles with different morphologies but the same ligand capping are investigated. The endothelial cells are incubated with gold nanospheres, nanorods, hollow gold spheres, and core/shell silica/gold nanocrystals, which are coated with monocarboxy (1-mercaptoundec-11-yl) hexaethylene glycol (OEG). Cell viability studies show that all types of gold particles are noncytotoxic. The number of particles taken up by the cells is estimated using inductively coupled plasma (ICP), and are found to differ depending on particle morphology. The above results are discussed with respect to heating efficiency. Using experimental data reported earlier and theoretical model calculations which take into account the physical properties and distribution of particles in the cellular microenvironment, it is found that collective heating effects of several cells loaded with nanoparticles must be included to explain the observed viability of the endothelial cells.


Assuntos
Células Endoteliais/citologia , Ouro/química , Nanopartículas Metálicas/química , Células Cultivadas , Células Endoteliais/ultraestrutura , Humanos , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Transmissão , Nanotecnologia
11.
Nano Lett ; 11(3): 1358-63, 2011 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-21322611

RESUMO

Laser-induced techniques that employ the surface plasmon resonances of nanoparticles have recently been introduced as an effective therapeutic tool for destroying tumor cells. Here, we adopt a low-intensity laser-induced technique to manipulate the damage and repair of a vital category of noncancerous cells, human endothelial cells. Endothelial cells construct the interior of blood vessels and play a pivotal role in angiogenesis. The degree of damage and repair of the cells is shown to be influenced by laser illumination in the presence of gold nanoparticles of different morphologies, which either target the cellular membrane or are endocytosed. A pronounced influence of the plasmonic nanoparticle laser treatment on the expression of critical angiogenic genes is shown. Our results show that plasmon-mediated mild laser treatment, combined with specific targeting of cellular membranes, enables new routes for controlling cell permeability and gene regulation in endothelial cells.


Assuntos
Endotélio Vascular/citologia , Células Cultivadas , Endotélio Vascular/ultraestrutura , Ouro , Humanos , Lasers , Nanopartículas Metálicas , Microscopia Eletrônica de Transmissão , Nanopartículas
12.
Nanomaterials (Basel) ; 12(7)2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35407290

RESUMO

Porous hollow silica particles possess promising applications in many fields, ranging from drug delivery to catalysis. From the synthesis perspective, the most challenging parameters are the monodispersity of the size distribution and the thickness and porosity of the shell of the particles. This paper demonstrates a facile two-pot approach to prepare monodisperse porous-hollow silica particles with uniform spherical shape and well-tuned shell thickness. In this method, a series of porous-hollow inorganic and organic-inorganic core-shell silica particles were synthesized via hydrolysis and condensation of 1,2-bis(triethoxysilyl) ethane (BTEE) and tetraethyl orthosilicate (TEOS) in the presence of hexadecyltrimethylammonium bromide (CTAB) as a structure-directing agent on solid silica spheres as core templates. Finally, the core templates were removed via hydrothermal treatment under alkaline conditions. Transmission electron microscopy (TEM) was used to characterize the particles' morphology and size distribution, while the changes in the chemical composition during synthesis were followed by Fourier-transform infrared spectroscopy. Single-particle inductively coupled plasma mass spectrometry (spICP-MS) was applied to assess the monodispersity of the hollow particles prepared with different reaction parameters. We found that the presence of BTEE is key to obtaining a well-defined shell structure, and the increase in the concentration of the precursor and the surfactant increases the thickness of the shell. TEM and spICP-MS measurements revealed that fused particles are also formed under suboptimal reaction parameters, causing the broadening of the size distribution, which can be preceded by using appropriate concentrations of BTEE, CTAB, and ammonia.

13.
Metallomics ; 14(12)2022 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-36367500

RESUMO

This paper discusses the feasibility of a novel strategy based on the combination of bioprinting nano-doping technology and laser ablation-inductively coupled plasma time-of-flight mass spectrometry analysis for the preparation and characterization of gelatin-based multi-element calibration standards suitable for quantitative imaging. To achieve this, lanthanide up-conversion nanoparticles were added to a gelatin matrix to produce the bioprinted calibration standards. The features of this bioprinting approach were compared with manual cryosectioning standard preparation, in terms of throughput, between batch repeatability and elemental signal homogeneity at 5 µm spatial resolution. By using bioprinting, the between batch variability for three independent standards of the same concentration of 89Y (range 0-600 mg/kg) was reduced to 5% compared to up to 27% for cryosectioning. On this basis, the relative standard deviation (RSD) obtained between three independent calibration slopes measured within 1 day also reduced from 16% (using cryosectioning) to 5% (using bioprinting), supporting the use of a single standard preparation replicate for each of the concentrations to achieve good calibration performance using bioprinting. This helped reduce the analysis time by approximately 3-fold. With cryosectioning each standard was prepared and sectioned individually, whereas using bio-printing it was possible to have up to six different standards printed simultaneously, reducing the preparation time from approximately 2 h to under 20 min (by approximately 6-fold). The bio-printed calibration standards were found stable for a period of 2 months when stored at ambient temperature and in the dark.


Assuntos
Bioimpressão , Espectrometria de Massas , Padrões de Referência , Nanopartículas , Calibragem
14.
Nanoscale ; 14(12): 4690-4704, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35262538

RESUMO

We describe the outcome of a large international interlaboratory study of the measurement of particle number concentration of colloidal nanoparticles, project 10 of the technical working area 34, "Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS). A total of 50 laboratories delivered results for the number concentration of 30 nm gold colloidal nanoparticles measured using particle tracking analysis (PTA), single particle inductively coupled plasma mass spectrometry (spICP-MS), ultraviolet-visible (UV-Vis) light spectroscopy, centrifugal liquid sedimentation (CLS) and small angle X-ray scattering (SAXS). The study provides quantitative data to evaluate the repeatability of these methods and their reproducibility in the measurement of number concentration of model nanoparticle systems following a common measurement protocol. We find that the population-averaging methods of SAXS, CLS and UV-Vis have high measurement repeatability and reproducibility, with between-labs variability of 2.6%, 11% and 1.4% respectively. However, results may be significantly biased for reasons including inaccurate material properties whose values are used to compute the number concentration. Particle-counting method results are less reproducibile than population-averaging methods, with measured between-labs variability of 68% and 46% for PTA and spICP-MS respectively. This study provides the stakeholder community with important comparative data to underpin measurement reproducibility and method validation for number concentration of nanoparticles.

15.
Small ; 7(3): 388-94, 2011 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-21294268

RESUMO

A new strategy to manipulate cell operations is demonstrated, based on membrane-receptor-specific interactions between colloidal peptide-capped gold nanoparticles and human umbilical vein endothelial cells. It is shown that colloidal gold nanoparticles of similar charge and size but capped with different peptide sequences can deliberately trigger specific cell functions related to the important biological process of blood vessel growth known as angiogenesis. Specific binding of the peptide-capped particles to two endothelial-expressed receptors (VEGFR-1, NRP-1), which control angiogenesis, is achieved. The cellular fate of the functional nanoparticles is imaged and the influence of the different peptide-coated nanoparticles on the gene expression profile of hypoxia-related and angiogenic genes is monitored. The findings open up new avenues towards the deliberate biological control of cellular functions using strategically designed nanoparticles.


Assuntos
Células Endoteliais/citologia , Coloide de Ouro/química , Nanopartículas Metálicas/química , Veias Umbilicais/citologia , Células Cultivadas , Células Endoteliais/metabolismo , Citometria de Fluxo , Humanos , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Transmissão
16.
Langmuir ; 27(16): 10119-23, 2011 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-21728291

RESUMO

Although carbodiimides and succinimides are broadly employed for the formation of amide bonds (i.e., in amino acid coupling), their use in the coupling of peptides to water-soluble carboxylic-terminated colloidal gold nanoparticles remains challenging. In this article, we present an optimization study for the successful coupling of the KPQPRPLS peptide to spherical and rodlike colloidal gold nanoparticles. We show that the concentration, reaction time, and chemical environment are all critical to achieving the formation of robust, peptide-coated colloidal nanoparticles. Agarose gel electrophoresis was used for the characterization of conjugates.


Assuntos
Ouro/química , Nanopartículas Metálicas/química , Peptídeos/química , Coloides/química , Eletroforese em Gel de Ágar
17.
Talanta ; 232: 122504, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34074453

RESUMO

A method based on asymmetric flow field-flow fractionation (AF4) coupled to ultraviolet-visible (UV-vis) spectroscopy and inductively coupled plasma mass spectrometry (ICP-MS) has been developed for silver nanoparticles (Ag NPs) detection and quantification in bivalve molluscs. Samples were pre-treated using a conventional enzymatic (pancreatin and lipase) hydrolysis procedure (37 °C, 12 h). AF4 was performed using a regenerated cellulose (RC) membrane (10 kDa, 350 µm spacer) and aqueous 5 mM Tris-HCl pH = 7.4 as carrier. AF4 separation was achieved with a program that included a focusing step with tip and focus flows of 0.20 and 3.0 mL min-1, respectively, and an injection time of 4.0 min. Elution of different size fractions was performed using a cross flow of 3.0 mL min-1 for 15 min, followed by linear cross flow decrease for 7.5 min, and a washing step for 9.4 min with no cross flow. Several bivalve molluscs (clams, oysters and variegated scallops) were analysed for total Ag content (ICP-MS after microwave assisted acid digestion), and for Ag NPs by the method presented here. Results show that Ag NPs are detected at the same elution time than proteins (UV monitoring at 280 and 405 nm), which suggests a certain interaction occurred between Ag NPs with proteins in the enzymatic extracts. AF4-UV-ICP-MS fractograms also suggest different Ag NPs size distributions for selected samples. Membrane recoveries, determined by peak area comparison of fractograms with and without application of cross flow, were within the 49-121% range. Confirmation of the presence Ag NPs in the investigated enzymatic extracts was demonstrated by SEM after an oxidative pre-treatment based on hydrogen peroxide and microwave irradiation.


Assuntos
Fracionamento por Campo e Fluxo , Nanopartículas Metálicas , Hidrólise , Espectrometria de Massas , Nanopartículas Metálicas/análise , Tamanho da Partícula , Alimentos Marinhos , Prata , Análise Espectral
18.
Langmuir ; 26(10): 7072-7, 2010 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-20078089

RESUMO

A new type of strategically designed functional ligands was used to cap gold nanocrystals and form robust colloidal nanoparticles, resistant to pH changes, temperature, and ionic strength variations as well as ligand-exchange reactions. The nanoparticles are coated with ligands that polymerize upon UV-irradiation, consequently embedding the particles in a stable organic shell. The ligand consists of an anchoring thiol group, which binds directly to the nanocrystal surface and two units, one hydrophobic and one hydrophilic. The hydrophobic alkyl unit contains a diacetylene group, which undergoes a 1,4-topochemical polymerization leading to a poly(enyne) structure during UV-irradiation. The hydrophilic unit contains an oligo-ethylene glycol chain, which ensures water solubility, and a terminal carboxylic group. Derived particles were characterized by transmission electron microscopy, surface enhanced Raman spectroscopy, and visible spectroscopy. Their stability was investigated and compared to particles capped with nonpolymerized ligands.


Assuntos
Acetileno/química , Nanopartículas/química , Água/química , Acetileno/análogos & derivados , Coloides/química , Ouro/química , Concentração de Íons de Hidrogênio , Ligantes , Concentração Osmolar , Tamanho da Partícula , Solubilidade , Propriedades de Superfície , Temperatura
19.
Langmuir ; 26(17): 13760-2, 2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20672816

RESUMO

We present a novel nanoparticle building block system based on the interactions between short synthetic oligonucleotides and peptides. Gold nanoparticles coated with DNA-binding peptides can be attached to self-organized oligonucleotide templates to formulate well-ordered structures of nanoparticles. By regulating the amount of DNA-binding peptide attached to the nanoparticle surface and using specifically designed oligonucleotides, the nanoparticle assembly can be controlled to form dimers, trimers, and adjustable-length nanoparticle chains as well as more complex structures.


Assuntos
DNA/química , Ouro/química , Nanopartículas Metálicas/química , Peptídeos/química , Oligonucleotídeos/química , Tamanho da Partícula , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa