Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 84(24): 5532-5, 2000 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-10990987

RESUMO

In reversed-field pinches, two different mechanisms have been proposed to explain the dynamo process which drives the poloidal current needed to sustain the magnetic configuration: the kinetic dynamo theory and the magnetohydrodynamic (MHD) dynamo theory. Experimentally, they can be distinguished by the radial behavior of the electron distribution function. In this Letter the trajectory deflection of frozen hydrogen pellets has been used as a diagnostic of suprathermal electrons in the plasma. The classical Spitzer-Harm distortion of the electron distribution function consistent with the MHD dynamo electric field is found to give a better modeling of the pellet trajectory.

3.
Appl Opt ; 34(15): 2712-8, 1995 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-21052416

RESUMO

The Frascati tokamak upgrade Thomson-scattering system is used for the measurement of electron-temperature and electron-density spatial profiles along the vertical diameter of the tokamak at 19 spatial points up to 10 times in a single plasma discharge, with a spatial resolution that ranges from 2 cm in the central region to 4 cm in the plasma edge. The radiation source is a Nd:YLF laser that operates at 1053 nm, with a divergence of 0.4 mrad full angle, and is capable of delivering a burst of 10 pulses with energies of 4.5 J/pulse; the interpulse time can be regulated from 20 to 100 ms. The scattered radiation is collected by two objectives: the first looks at the plasma center, and the second at the plasma edge. Bundles of optical fibers in the focal plane of the objectives carry the scattered light from the tokamak hall to a set of 19 interference-filter polychromators, whose transmission is 70%, and the rejection of the stray light at the laser wavelength is 1/10(7). The detectors are avalanche photodiodes ith a noise-equivalent power of the order of 10(-13) W/(Hz)(½) at 1053 nm. The spectral calibration of the polychromators is presented. The absolute calibration of the scattering system for the electron-density measurement has been carried out by the use of Raman scattering on hydrogen and deuterium. Examples of the results of the temporal evolution of T(e) and n(e) spatial profiles are presented for ohmic plasma heating, lower-hybrid current drive, and a pellet-injection experiment. The electron-temperature and electron-density profiles measured through Thomson scattering are compared with the temperatures measured through the use of electron-cyclotron emission and the density profiles obtained from the interferometer data.

4.
Phys Rev A Gen Phys ; 32(1): 531-537, 1985 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9896076
5.
Phys Rev A Gen Phys ; 40(12): 7387-7390, 1989 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-9902161
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa