1.
Qual Life Res ; 32(9): 2667-2679, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37118365

RESUMO

PURPOSE: To assess the psychometric properties of glaucoma-specific health-related quality of life (HRQoL) item banks (IBs), and explore their efficiency using computerized adaptive testing (CAT) simulations. METHODS: In this cross-sectional, clinical study, 300 Asian glaucoma patients answered 221 items within seven IBs: Ocular Comfort Symptoms (OS); Activity Limitation (AL); Lighting (LT); Mobility (MB); Glaucoma Management (GM); Psychosocial (PSY); and Work (WK). Rasch analysis was conducted to assess each IB's psychometric properties (e.g., item "fit" to the construct; unidimensionality) and a set of analytic performance criteria guiding decision making relating to retaining or dropping domains and items was employed. CAT simulations determined the mean number of items for 'high' and 'moderate' measurement precision (stopping rule: SEM 0.3 and 0.387, respectively). RESULTS: Participants' mean age was 67.2 ± 9.2 years (62% male; 87% Chinese). LT, MB, and GM displayed good psychometric properties overall. To optimize AL's psychometric properties, 16 items were deleted due to poor "fit", high missing data, item bias, low discrimination and/or a low clinical/patient importance rating. To resolve multidimensionality in PSY, we rehomed 16 items into a "Concern (CN)" domain. PSY and CN required further amendment, including collapsing of response categories, and removal of poorly functioning items (N = 7). Due to poor measurement precision, low applicability and high ceiling effect, low test information indices, and low item separation index the WK IB was not considered further. In CAT simulations on the final seven IBs (n = 182 items total), an average of 12.1 and 15.7 items per IB were required for moderate and high precision measurement, respectively. CONCLUSIONS: After reengineering our seven IBs, they displayed robust psychometric properties and good efficiency in CAT simulations. Once finalized, GlauCAT™-Asian may enable comprehensive assessment of the HRQoL impact of glaucoma and associated treatments.


Assuntos
Glaucoma , Psicometria , Qualidade de Vida , Feminino , Humanos , Masculino , Teste Adaptativo Computadorizado , Estudos Transversais , Qualidade de Vida/psicologia , Reprodutibilidade dos Testes , Inquéritos e Questionários
2.
Ophthalmology ; 129(3): 285-294, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34592243

RESUMO

PURPOSE: We hypothesized that the effect of blood lipid-related metabolites on primary open-angle glaucoma (POAG) would differ according to specific lipoprotein particles and lipid sub-fractions. We investigated the associations of blood levels of lipoprotein particles and lipid sub-fractions with POAG. DESIGN: Cross-sectional study. PARTICIPANTS: Individuals recruited for the baseline visit of the population-based Singapore Epidemiology of Eye Disease study (n = 8503). METHODS: All participants underwent detailed standardized ocular and systemic examinations. A total of 130 blood lipid-related metabolites were quantified using a nuclear magnetic resonance metabolomics platform. The analyses were conducted in 2 stages. First, we investigated whether and which lipid-related metabolites were directly associated with POAG using regression analyses followed by Bayesian network modeling. Second, we investigated if any causal relationship exists between the identified lipid-related metabolites, if any, and POAG using 2-sample Mendelian randomization (MR) analysis. We performed genome-wide association studies (GWAS) on high-density lipoprotein (HDL) 3 cholesterol (after inverse normal transformation) and used the top variants associated with HLD3 cholesterol as instrumental variables (IVs) in the MR analysis. MAIN OUTCOME MEASURE: Primary open-angle glaucoma. RESULTS: Of the participants, 175 (2.1%) had POAG. First, a logistic regression model showed that total HDL3 cholesterol (negatively) and phospholipids in very large HDL (positively) were associated with POAG. Further analyses using a Bayesian network analysis showed that only total HDL3 cholesterol was directly associated with POAG (odds ratio [OR], 0.72 per 1 standard deviation increase in HDL3 cholesterol; 95% confidence interval [CI], 0.61-0.84), independently of age, gender, intraocular pressure (IOP), body mass index (BMI), education level, systolic blood pressure, axial length, and statin medication. Using 5 IVs identified from the GWAS and with the inverse variance weighted MR method, we found that higher levels of HDL3 cholesterol were associated with a decreased odds of POAG (OR, 0.91; 95% CI, 0.84-0.99, P = 0.021). Other MR methods, including weighted median, mode-based estimator, and contamination mixture methods, derived consistent OR estimates. None of the routine lipids (blood total, HDL, or low-density lipoprotein [LDL] cholesterol) were associated with POAG. CONCLUSIONS: Overall, these results suggest that the relationship between HDL3 cholesterol and POAG might be causal and specific, and that dysregulation of cholesterol transport may play a role in the pathogenesis of POAG.


Assuntos
HDL-Colesterol/sangue , Glaucoma de Ângulo Aberto/sangue , Análise da Randomização Mendeliana , Metabolômica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto/diagnóstico , Gonioscopia , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Razão de Chances , Polimorfismo de Nucleotídeo Único , Microscopia com Lâmpada de Fenda , Tonometria Ocular
3.
Ophthalmology ; 129(2): 147-158, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34453952

RESUMO

PURPOSE: To examine the efficacy of laser peripheral iridotomy (LPI) in patients who received a diagnosis of primary angle-closure suspect (PACS). DESIGN: Prospective, randomized controlled trial. PARTICIPANTS: This multicenter, randomized controlled trial (ClinicalTrials.gov identifier, NCT00347178) enrolled 480 patients older than 50 years from glaucoma clinics in Singapore with bilateral asymptomatic PACS (defined as having ≥2 quadrants of appositional angle closure on gonioscopy). METHODS: Each participant underwent prophylactic LPI in 1 randomly selected eye, whereas the fellow eye served as a control. Patients were followed up yearly for 5 years. MAIN OUTCOME MEASURES: The primary outcome measure was development of primary angle closure (PAC; defined as presence of peripheral anterior synechiae, intraocular pressure [IOP] of >21 mmHg, or both or acute angle closure [AAC]) or primary angle-closure glaucoma (PACG) over 5 years. RESULTS: Of the 480 randomized participants, most were Chinese (92.7%) and were women (75.8%) with mean age of 62.8 ± 6.9 years. Eyes treated with LPI reached the end point less frequently after 5 years (n = 24 [5.0%]; incidence rate [IR], 11.65 per 1000 eye-years) compared with control eyes (n = 45 [9.4%]; IR, 21.84 per 1000 eye-years; P = 0.001). The adjusted hazard ratio (HR) for progression to PAC was 0.55 (95% confidence interval [CI], 0.37-0.83; P = 0.004) in LPI-treated eyes compared with control eyes. Older participants (per year; HR, 1.06; 95% CI, 1.03-1.10; P < 0.001) and eyes with higher baseline IOP (per millimeter of mercury; HR, 1.35; 95% CI, 1.22-1.50; P < 0.0001) were more likely to reach an end point. The number needed to treat to prevent an end point was 22 (95% CI, 12.8-57.5). CONCLUSIONS: In patients with bilateral asymptomatic PACS, eyes that underwent prophylactic LPI reached significantly fewer end points compared with control eyes over 5 years. However, the overall incidence of PAC or PACG was low.


Assuntos
Glaucoma de Ângulo Fechado/cirurgia , Iridectomia/métodos , Iris/cirurgia , Lasers de Estado Sólido/uso terapêutico , Idoso , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Singapura , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
4.
Hum Mol Genet ; 27(8): 1486-1496, 2018 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-29452408

RESUMO

Primary open-angle glaucoma (POAG) is the leading cause of irreversible blindness worldwide for which 15 disease-associated loci had been discovered. Among them, only 5 loci have been associated with POAG in Asians. We carried out a genome-wide association study and a replication study that included a total of 7378 POAG cases and 36 385 controls from a Japanese population. After combining the genome-wide association study and the two replication sets, we identified 11 POAG-associated loci, including 4 known (CDKN2B-AS1, ABCA1, SIX6 and AFAP1) and 7 novel loci (FNDC3B, ANKRD55-MAP3K1, LMX1B, LHPP, HMGA2, MEIS2 and LOXL1) at a genome-wide significance level (P < 5.0×10-8), bringing the total number of POAG-susceptibility loci to 22. The 7 novel variants were subsequently evaluated in a multiethnic population comprising non-Japanese East Asians (1008 cases, 591 controls), Europeans (5008 cases, 35 472 controls) and Africans (2341 cases, 2037 controls). The candidate genes located within the new loci were related to ocular development (LMX1B, HMGA2 and MAP3K1) and glaucoma-related phenotypes (FNDC3B, LMX1B and LOXL1). Pathway analysis suggested epidermal growth factor receptor signaling might be involved in POAG pathogenesis. Genetic correlation analysis revealed the relationships between POAG and systemic diseases, including type 2 diabetes and cardiovascular diseases. These results improve our understanding of the genetic factors that affect the risk of developing POAG and provide new insight into the genetic architecture of POAG in Asians.


Assuntos
Doenças Cardiovasculares/genética , Diabetes Mellitus Tipo 2/genética , Proteínas do Olho/genética , Loci Gênicos , Predisposição Genética para Doença , Glaucoma de Ângulo Aberto/genética , Povo Asiático , População Negra , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/etnologia , Doenças Cardiovasculares/patologia , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/etnologia , Diabetes Mellitus Tipo 2/patologia , Receptores ErbB/genética , Receptores ErbB/metabolismo , Proteínas do Olho/metabolismo , Feminino , Expressão Gênica , Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/patologia , Humanos , Masculino , Mutação , Polimorfismo de Nucleotídeo Único , Transdução de Sinais , População Branca
5.
Hum Mol Genet ; 26(20): 4011-4027, 2017 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-29016860

RESUMO

PLEKHA7, a gene recently associated with primary angle closure glaucoma (PACG), encodes an apical junctional protein expressed in components of the blood aqueous barrier (BAB). We found that PLEKHA7 is down-regulated in lens epithelial cells and in iris tissue of PACG patients. PLEKHA7 expression also correlated with the C risk allele of the sentinel SNP rs11024102 with the risk allele carrier groups having significantly reduced PLEKHA7 levels compared to non-risk allele carriers. Silencing of PLEKHA7 in human immortalized non-pigmented ciliary epithelium (h-iNPCE) and primary trabecular meshwork cells, which are intimately linked to BAB and aqueous humor outflow respectively, affected actin cytoskeleton organization. PLEKHA7 specifically interacts with GTP-bound Rac1 and Cdc42, but not RhoA, and the activation status of the two small GTPases is linked to PLEKHA7 expression levels. PLEKHA7 stimulates Rac1 and Cdc42 GTP hydrolysis, without affecting nucleotide exchange, identifying PLEKHA7 as a novel Rac1/Cdc42 GAP. Consistent with the regulatory role of Rac1 and Cdc42 in maintaining the tight junction permeability, silencing of PLEKHA7 compromises the paracellular barrier between h-iNPCE cells. Thus, downregulation of PLEKHA7 in PACG may affect BAB integrity and aqueous humor outflow via its Rac1/Cdc42 GAP activity, thereby contributing to disease etiology.


Assuntos
Proteínas de Transporte/genética , Glaucoma de Ângulo Fechado/genética , Proteína cdc42 de Ligação ao GTP/genética , Proteínas rac1 de Ligação ao GTP/genética , Barreira Hematoaquosa/metabolismo , Proteínas de Transporte/metabolismo , Movimento Celular/genética , Células Epiteliais/metabolismo , Predisposição Genética para Doença , Glaucoma de Ângulo Fechado/metabolismo , Glaucoma de Ângulo Fechado/patologia , Humanos , Junções Intercelulares/metabolismo , Iris/metabolismo , Iris/patologia , Polimorfismo de Nucleotídeo Único , Junções Íntimas/metabolismo , Proteína cdc42 de Ligação ao GTP/metabolismo , Proteínas rac1 de Ligação ao GTP/metabolismo
6.
Hum Mol Genet ; 26(2): 438-453, 2017 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-28073927

RESUMO

Primary open-angle glaucoma (POAG), the most common optic neuropathy, is a heritable disease. Siblings of POAG cases have a ten-fold increased risk of developing the disease. Intraocular pressure (IOP) and optic nerve head characteristics are used clinically to predict POAG risk. We conducted a genome-wide association meta-analysis of IOP and optic disc parameters and validated our findings in multiple sets of POAG cases and controls. Using imputation to the 1000 genomes (1000G) reference set, we identified 9 new genomic regions associated with vertical cup-disc ratio (VCDR) and 1 new region associated with IOP. Additionally, we found 5 novel loci for optic nerve cup area and 6 for disc area. Previously it was assumed that genetic variation influenced POAG either through IOP or via changes to the optic nerve head; here we present evidence that some genomic regions affect both IOP and the disc parameters. We characterized the effect of the novel loci through pathway analysis and found that pathways involved are not entirely distinct as assumed so far. Further, we identified a novel association between CDKN1A and POAG. Using a zebrafish model we show that six6b (associated with POAG and optic nerve head variation) alters the expression of cdkn1a. In summary, we have identified several novel genes influencing the major clinical risk predictors of POAG and showed that genetic variation in CDKN1A is important in POAG risk.


Assuntos
Inibidor de Quinase Dependente de Ciclina p21/genética , Glaucoma de Ângulo Aberto/genética , Proteínas de Homeodomínio/genética , Doenças do Nervo Óptico/genética , Proteínas de Peixe-Zebra/genética , Feminino , Genoma Humano , Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto/patologia , Humanos , Pressão Intraocular/genética , Masculino , Pessoa de Meia-Idade , Disco Óptico/patologia , Doenças do Nervo Óptico/patologia , Tonometria Ocular
7.
Ophthalmology ; 125(9): 1362-1371, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29573814

RESUMO

PURPOSE: To evaluate the ability of chromatic pupillometry to reveal abnormal pupillary responses to light in patients with early-stage primary open-angle glaucoma (POAG) and to test whether the degree of pupillometric impairment correlates with structural hallmarks of optic nerve damage in the disease. DESIGN: Cross-sectional study. PARTICIPANTS: Forty-six patients with early-stage POAG (63.4±8.3 years, 63% male, 87% ethnic-Chinese) and 90 age-matched healthy controls (61.4±8.6 years, 34% male, 89% ethnic-Chinese). Patients with POAG had a visual field mean deviation (VFMD) of -6 decibels or better on automated perimetry. METHODS: Each participant underwent a monocular 2-minute exposure to blue light (462 nm) followed by another 2-minute exposure to red light (638 nm) using a modified Ganzfeld dome equipped with a light-emitting diode lighting system. The light stimuli intensity was increased logarithmically to evaluate the combined extrinsic and intrinsic response of intrinsically photosensitive retinal ganglion cells (ipRGCs). Light-induced changes in horizontal pupil diameter were assessed monocularly using infrared pupillography. MAIN OUTCOME MEASURES: Baseline-adjusted, light-induced pupillary constriction amplitudes were calculated, and individual irradiance-response curves were constructed for each stimulus. Pupillary constriction amplitudes were compared between groups and across light intensities using a linear mixed model analysis. The linear relationship between pupillometric parameters and different structural and functional features of glaucoma was assessed using Pearson's correlation analysis. RESULTS: Light-induced pupillary constriction was reduced in patients with early-stage POAG compared with controls at moderate to high irradiances (≥11 Log photons/cm2/s) of blue (P = 0.003) and red (P < 0.001) light. Maximal pupillary constriction amplitude was correlated with retinal nerve fiber layer thickness (RNFL) thickness (blue: r = 0.51, P < 0.001; red: r = 0.45, P = 0.002) in patients with POAG but not in controls. Conversely, pupillometric parameters were not correlated with visual field scores in patients with early-stage POAG. CONCLUSIONS: Patients with early-stage POAG exhibit reduced pupillary responses to moderate and high irradiances of blue and red lights. This wavelength-independent functional alteration correlates with structural thinning of the RNFL and could be the consequence of dysfunction or loss of melanopsin expressing ipRGCs in the early stages of the disease.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Pupila/fisiologia , Reflexo Pupilar/fisiologia , Células Ganglionares da Retina/patologia , Estudos Transversais , Progressão da Doença , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Testes de Campo Visual/métodos , Campos Visuais
8.
Ophthalmology ; 125(5): 664-670, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29310965

RESUMO

PURPOSE: To investigate whether newly identified genetic loci for primary angle-closure glaucoma (PACG) are associated with early stage angle-closure disease defined as primary angle closure suspect (PACS). DESIGN: Case-control study. PARTICIPANTS: A total of 1397 PACS patients and 943 controls of Chinese ethnicity from Singapore and 604 PACS patients and 287 controls of Indian ethnicity. METHODS: The 8 PACG single nucleotide polymorphisms (SNPs; rs11024102 at PLEKHA7, rs3753841 at COL11A1, rs1015213 located between PCMTD1 and ST18 son chromosome 8q, rs3816415 at EPDR1, rs1258267 at CHAT, rs736893 at GLIS3, rs7494379 at FERMT2, and rs3739821 mapping in between DPM2 and FAM102A) were genotyped by Taqman assays. The association between SNP genotypes and PACS status was measured using logistic regression. A P value of 0.006 was set to account for the testing of 8 genetic loci using a Bonferroni correction. A meta-analysis was conducted to calculate the overall P value and accompanying per-allele odds ratios for each SNP analyzed. MAIN OUTCOME MEASURES: Association of PACG loci with PACS status. RESULTS: The PACS patients were significantly older in both cohorts (Chinese, P < 0.001; Indian, P = 0.002), and there were also more women (P < 0.001, both Chinese and Indian cohorts). In the Chinese cohort, significant evidence of association was noted at 3 SNPs: rs1015213 [A] in PCMTD1-ST18 (odds ratio [OR], 2.36; 95% confidence interval [CI], 1.36-4.11; P = 0.002), rs3816415 [A] in EPDR1 (OR, 1.49; 95% CI, 1.19-1.85; P < 0.001), and rs3739821 [G] in DPM2-FAM102A (OR, 1.40; 95% CI, 1.18-1.65; P < 0.001). Only PCMTD1-ST-18 was replicated modestly in the Indian population (P = 0.056). Meta-analysis showed significant evidence of association for PCMTD1-ST-18 (OR, 1.55; 95% CI, 1.18-2.04; P = 0.002) and DPM2-FAM102A (OR, 1.27; 95% CI, 1.12-1.45; P = 0.0002). CONCLUSIONS: In this study, 2 of 8 PACG-associated loci were associated significantly with PACS status, the earliest stage in the angle-closure glaucoma disease course. The association of these PACG loci with PACS status suggests that these loci may confer susceptibility to a narrow angle configuration.


Assuntos
Loci Gênicos , Predisposição Genética para Doença , Glaucoma de Ângulo Fechado/genética , Manosiltransferases/genética , Polimorfismo de Nucleotídeo Único , Proteína D-Aspartato-L-Isoaspartato Metiltransferase/genética , Proteínas/genética , Proteínas Repressoras/genética , Idoso , Povo Asiático/genética , Estudos de Casos e Controles , Feminino , Estudos de Associação Genética , Técnicas de Genotipagem , Glaucoma de Ângulo Fechado/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Singapura/epidemiologia
9.
Clin Exp Ophthalmol ; 46(2): 147-157, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29193702

RESUMO

This article aims to review the published literature pertaining to the use of anterior segment optical coherence tomography (AS-OCT) in the evaluation of angle-closure disease. Searches on the available published literature were last conducted on 15 June 2017. Rated as Level I evidence, we found that AS-OCT has shown good sensitivity and moderate diagnostic accuracy to detect narrow angles when compared with gonioscopy. AS-OCT quantitative and qualitative parameters demonstrated strong association with the presence of gonioscopically closed angles. This technology provides an objective non-contact method of assessing the angle that is well tolerated by the patient and correlates well with the information provided by gonioscopy.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Glaucoma de Ângulo Fechado/diagnóstico , Tomografia de Coerência Óptica/métodos , Glaucoma de Ângulo Fechado/fisiopatologia , Humanos , Pressão Intraocular/fisiologia
10.
Clin Exp Ophthalmol ; 46(1): 25-34, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28621876

RESUMO

IMPORTANCE: There is limited literature on lifestyle and health factors related to primary open-angle glaucoma amongst Asians. BACKGROUND: This study evaluated the association of primary open-angle glaucoma with smoking, health and ocular factors amongst Chinese Singaporeans. DESIGN: Case-control study. PARTICIPANTS: The study used 711 primary open-angle glaucoma patients from a Singapore hospital and 2788 population-based controls. METHODS: Subjects underwent clinical examination and completed a questionnaire with details on family history of glaucoma, comorbidities, smoking and alcohol consumption. Glaucoma cases were subclassified as normal or high-tension glaucoma according to their untreated intraocular pressures. MAIN OUTCOME MEASURES: The association of various health and lifestyle factors, with normal-tension and high-tension glaucoma was evaluated. RESULTS: Using multiple logistic regression, primary open-angle glaucoma was associated with older age (odds ratio 1.12 per year older; 95% confidence interval 1.10-1.15; P < 0.001), family history of glaucoma (odds ratio 7.86; 95% confidence interval 4.48-13.79; P < 0.001), higher intraocular pressure (odds ratio 1.75 per 1 mmHg; 95% confidence interval 1.64-1.87; P < 0.001) and thinner central corneal thickness (odds ratio 1.01; 95% confidence interval 1.01-1.02; P < 0.001). Myopes were more likely to have primary open-angle glaucoma (P < 0.001). A current smoking habit was protective against normal-tension glaucoma (odds ratio 0.30; 95% confidence interval 0.10-0.92; P = 0.035). CONCLUSIONS AND RELEVANCE: Older age, family history of glaucoma, higher intraocular pressure, thinner central corneal thickness and myopia were significantly associated with primary open-angle glaucoma amongst Chinese Singaporeans.


Assuntos
Glaucoma de Ângulo Aberto/etnologia , Pressão Intraocular/fisiologia , Estilo de Vida , Acuidade Visual , Idoso , China/etnologia , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/psicologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Singapura/epidemiologia
11.
Clin Exp Ophthalmol ; 45(5): 464-471, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28098418

RESUMO

IMPORTANCE: The evaluation of anterior chamber scan of Cirrus optical coherence tomography for routine clinical use. BACKGROUND: To assess the variability of anterior chamber angle measurements. DESIGN: This was a cross-sectional study. PARTICIPANTS: Forty subjects aged 40-80 years were included. METHODS: One randomly selected eye from 40 subjects was imaged with Cirrus optical coherence tomography (Carl Zeiss Meditec, Dublin, CA) by two different operators (expert vs. non-expert) with a 15-min interval for inter-observer and intra-observer variability of image acquisition. For image grading, the angle opening distance (AOD750) and the trabecular iris space area (TISA750) of nasal and temporal quadrants were measured with a customized algorithm (ImageJ, NIH, Bethesda, MD) by two different graders in a masked and random fashion. Bland Altman analysis and intraclass correlation coefficient (ICC) were calculated. MAIN OUTCOME MEASURES: ICC and limit of agreements (LOA). RESULTS: There were 15 (37.5%) eyes with closed angles. For inter-observer variability, the mean difference (95% LOA) of AOD750 for image acquisition and grading were -0.0039 mm (-0.0486, 0.0408) and 0.0011 mm (-0.0228, 0.025), respectively. The mean difference (95% LOA) of AOD750 for intra-observer variability for image acquisition and grading were 0.0013 mm (-0.0362, 0.0389) and -0.0013 mm (-0.0482, 0.0457), respectively. The ICCs were all ≥0.9. There was no significant difference in measurement variability between open and closed angles (P > 0.05). CONCLUSIONS AND RELEVANCE: Anterior chamber scan had low inter-observer and intra-observer variability in quantitative evaluation that was not affected by the angle status or the experience of an operator.


Assuntos
Algoritmos , Câmara Anterior/diagnóstico por imagem , Glaucoma/diagnóstico , Processamento de Imagem Assistida por Computador , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
12.
JAMA ; 318(22): 2211-2223, 2017 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-29234807

RESUMO

Importance: A deep learning system (DLS) is a machine learning technology with potential for screening diabetic retinopathy and related eye diseases. Objective: To evaluate the performance of a DLS in detecting referable diabetic retinopathy, vision-threatening diabetic retinopathy, possible glaucoma, and age-related macular degeneration (AMD) in community and clinic-based multiethnic populations with diabetes. Design, Setting, and Participants: Diagnostic performance of a DLS for diabetic retinopathy and related eye diseases was evaluated using 494 661 retinal images. A DLS was trained for detecting diabetic retinopathy (using 76 370 images), possible glaucoma (125 189 images), and AMD (72 610 images), and performance of DLS was evaluated for detecting diabetic retinopathy (using 112 648 images), possible glaucoma (71 896 images), and AMD (35 948 images). Training of the DLS was completed in May 2016, and validation of the DLS was completed in May 2017 for detection of referable diabetic retinopathy (moderate nonproliferative diabetic retinopathy or worse) and vision-threatening diabetic retinopathy (severe nonproliferative diabetic retinopathy or worse) using a primary validation data set in the Singapore National Diabetic Retinopathy Screening Program and 10 multiethnic cohorts with diabetes. Exposures: Use of a deep learning system. Main Outcomes and Measures: Area under the receiver operating characteristic curve (AUC) and sensitivity and specificity of the DLS with professional graders (retinal specialists, general ophthalmologists, trained graders, or optometrists) as the reference standard. Results: In the primary validation dataset (n = 14 880 patients; 71 896 images; mean [SD] age, 60.2 [2.2] years; 54.6% men), the prevalence of referable diabetic retinopathy was 3.0%; vision-threatening diabetic retinopathy, 0.6%; possible glaucoma, 0.1%; and AMD, 2.5%. The AUC of the DLS for referable diabetic retinopathy was 0.936 (95% CI, 0.925-0.943), sensitivity was 90.5% (95% CI, 87.3%-93.0%), and specificity was 91.6% (95% CI, 91.0%-92.2%). For vision-threatening diabetic retinopathy, AUC was 0.958 (95% CI, 0.956-0.961), sensitivity was 100% (95% CI, 94.1%-100.0%), and specificity was 91.1% (95% CI, 90.7%-91.4%). For possible glaucoma, AUC was 0.942 (95% CI, 0.929-0.954), sensitivity was 96.4% (95% CI, 81.7%-99.9%), and specificity was 87.2% (95% CI, 86.8%-87.5%). For AMD, AUC was 0.931 (95% CI, 0.928-0.935), sensitivity was 93.2% (95% CI, 91.1%-99.8%), and specificity was 88.7% (95% CI, 88.3%-89.0%). For referable diabetic retinopathy in the 10 additional datasets, AUC range was 0.889 to 0.983 (n = 40 752 images). Conclusions and Relevance: In this evaluation of retinal images from multiethnic cohorts of patients with diabetes, the DLS had high sensitivity and specificity for identifying diabetic retinopathy and related eye diseases. Further research is necessary to evaluate the applicability of the DLS in health care settings and the utility of the DLS to improve vision outcomes.


Assuntos
Retinopatia Diabética/diagnóstico , Oftalmopatias/diagnóstico , Aprendizado de Máquina , Retina/patologia , Área Sob a Curva , Conjuntos de Dados como Assunto , Diabetes Mellitus/etnologia , Retinopatia Diabética/etnologia , Oftalmopatias/etnologia , Feminino , Glaucoma/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Retina/diagnóstico por imagem , Sensibilidade e Especificidade
13.
Ophthalmology ; 123(3): 514-21, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26707418

RESUMO

PURPOSE: To determine the effectiveness of argon laser peripheral iridoplasty (ALPI) in primary angle closure (PAC) and primary angle-closure glaucoma (PACG). DESIGN: Randomized controlled trial. PARTICIPANTS: Eighty PAC or PACG subjects who underwent laser iridotomy (LI) and had at least 180° of persistent appositional angle closure and intraocular pressure (IOP) of more than 21 mmHg were enrolled. METHODS: Subjects were randomized to receive either 360° ALPI (Visulas 532s; Carl Zeiss Meditec, Jena, Germany) or medical therapy (Travoprost 0.004%; Alcon-Couvreur, Puurs, Antwerp, Belgium). Repeat ALPI was performed if the IOP reduction was less than 20% from baseline along with inadequate angle widening at the month 1 or month 3 visit. Intraocular pressure was controlled with systematic addition of medications when required. MAIN OUTCOME MEASURES: The primary outcome measure was success rates after ALPI at 1 year. Complete success was defined as an IOP of 21 mmHg or less without medication, and qualified success was defined as an IOP of 21 mmHg or less with medication. Failure was defined as an IOP more than 21 mmHg despite additional medications or requiring glaucoma surgery. RESULTS: Forty subjects (51 eyes) were randomized to ALPI and 40 subjects (55 eyes) were randomized to medical therapy. Complete success (IOP ≤21 mmHg without medication) was achieved in 35.0% eyes of the ALPI group compared with 85.0% of eyes in the prostaglandin analog (PGA) group (P < 0.001), and qualified success (IOP ≤21 mmHg with medication) was achieved in 35.0% and 7.5%, respectively (P = 0.003). The IOP decreased by 4.9 mmHg (95% confidence interval [CI], 3.5-6.3 mmHg) in the ALPI group (P < 0.001) and by 6.1 mmHg (95% CI, 5.1-7.1 mmHg) in the medication group (P < 0.001). A failure rate of 30.0% was noted in the ALPI group compared with 7.5% in the medication group (P = 0.01). No treatment-related complications were recorded in either group. CONCLUSIONS: After 1 year, ALPI was associated with higher failure rates and lower IOP reduction compared with PGA therapy in eyes with persistent appositional angle closure and raised IOP after LI.


Assuntos
Glaucoma de Ângulo Fechado/cirurgia , Iridectomia , Iris/cirurgia , Lasers de Excimer/uso terapêutico , Idoso , Anti-Hipertensivos/uso terapêutico , Tartarato de Brimonidina/uso terapêutico , Feminino , Glaucoma de Ângulo Fechado/tratamento farmacológico , Glaucoma de Ângulo Fechado/fisiopatologia , Humanos , Pressão Intraocular/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Reoperação , Centros de Atenção Terciária , Tonometria Ocular , Travoprost/uso terapêutico , Resultado do Tratamento
14.
Graefes Arch Clin Exp Ophthalmol ; 254(7): 1353-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26968720

RESUMO

PURPOSE: To determine the ocular anatomical factors influencing the pupillary light reactions to different wavelengths of light, measured with chromatic pupillometry. METHODS: Community-based, cross-sectional study including subjects with normal ocular health (ages 50-79 years). Direct pupillary responses to continuously increasing irradiances (6.8 to 13.8 log photons cm(-2) s(-1)) of red (631 nm) and blue (469 nm) light were measured, using a dedicated infrared pupillometer. All subjects underwent swept source optical coherence tomography (SS-OCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) and noncontact partial coherence laser interferometry (Lenstar LS900, Haag-Streit AG, Switzerland). Univariate and multivariable regression analyses were performed to determine the anatomical features influencing pupillographic parameters. RESULTS: Among the 177 included subjects, 167 (94.4 %) were Chinese and 116 (65.5 %) female. The average baseline pupil diameter in darkness (ß = -0.080, p < 0.001) and the amplitude of the relative pupillary constriction (ß = -0.233, p = 0.006) to blue light decreased with age. The amplitude of pupillary constriction was significantly larger in patients with a thinner iris, in response to stimulation with blue (ß = -0.321, p < 0.001) and red light (ß = -0.336, p < 0.001). Other ocular parameters (i.e., lens vault, anterior chamber depth width, iris volume, iris curvature, and lens thickness) were not significantly associated with pupillometric outcomes. CONCLUSIONS: The amplitude of the pupillary light constriction to chromatic photic stimuli is reduced with increasing age and iris thickness in subjects with normal ocular health, a finding which needs to be integrated into future pupillometric studies.


Assuntos
Câmara Anterior/diagnóstico por imagem , Pressão Intraocular/fisiologia , Pupila/fisiologia , Reflexo Pupilar/fisiologia , Campos Visuais , Idoso , Estudos Transversais , Feminino , Gonioscopia , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Tomografia de Coerência Óptica
15.
Ophthalmology ; 122(9): 1777-85, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26299721

RESUMO

PURPOSE: To evaluate whether a chromatic pupillometry test can be used to detect impaired function of intrinsically photosensitive retinal ganglion cells (ipRGCs) in patients with primary open-angle glaucoma (POAG) and to determine if pupillary responses correlate with optic nerve damage and visual loss. DESIGN: Cross-sectional study. PARTICIPANTS: One hundred sixty-one healthy controls recruited from a community polyclinic (55 men; 151 ethnic Chinese) and 40 POAG patients recruited from a glaucoma clinic (22 men; 35 ethnic Chinese) 50 years of age or older. METHODS: Subjects underwent monocular exposure to narrowband blue light (469 nm) or red light (631 nm) using a modified Ganzfeld dome. Each light stimulus was increased gradually over 2 minutes to activate sequentially the rods, cones, and ipRGCs that mediate the pupillary light reflex. Pupil diameter was recorded using an infrared pupillography system. MAIN OUTCOME MEASURES: Pupillary responses to blue light and red light were compared between control subjects and those with POAG by constructing dose-response curves across a wide range of corneal irradiances (7-14 log photons/cm(2) per second). In patients with POAG, pupillary responses were evaluated relative to standard automated perimetry testing (Humphrey Visual Field [HVF]; Carl Zeiss Meditec, Dublin, CA) and scanning laser ophthalmoscopy parameters (Heidelberg Retinal Tomography [HRT]; Heidelberg Engineering, Heidelberg, Germany). RESULTS: The pupillary light reflex was reduced in patients with POAG only at higher irradiance levels, corresponding to the range of activation of ipRGCs. Pupillary responses to high-irradiance blue light associated more strongly with disease severity compared with responses to red light, with a significant linear correlation observed between pupil diameter and HVF mean deviation (r = -0.44; P = 0.005) as well as HRT linear cup-to-disc ratio (r = 0.61; P < 0.001) and several other optic nerve head parameters. CONCLUSIONS: In glaucomatous eyes, reduced pupillary responses to high-irradiance blue light were associated with greater visual field loss and optic disc cupping. In POAG, a short chromatic pupillometry test that evaluates the function of ipRGCs can be used to estimate the degree of damage to retinal ganglion cells that mediate image-forming vision. This approach could prove useful in detecting glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Luz , Doenças do Nervo Óptico/diagnóstico , Distúrbios Pupilares/diagnóstico , Reflexo Pupilar/efeitos da radiação , Células Ganglionares da Retina/patologia , Transtornos da Visão/diagnóstico , Idoso , Povo Asiático , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/classificação , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Tonometria Ocular , Acuidade Visual/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia
16.
Ophthalmology ; 122(12): 2380-4, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26359189

RESUMO

PURPOSE: To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. DESIGN: Prospective, observational study. PARTICIPANTS: Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. METHODS: All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. MAIN OUTCOME MEASURES: Gonioscopic angle closure in 2 or 3 quadrants after 4 years. RESULTS: There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). CONCLUSIONS: Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at baseline.


Assuntos
Segmento Anterior do Olho/patologia , Glaucoma de Ângulo Fechado/diagnóstico , Gonioscopia , Tomografia de Coerência Óptica , Idoso , Povo Asiático/etnologia , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/etnologia , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/patologia , Humanos , Incidência , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acuidade Visual/fisiologia , Campos Visuais/fisiologia
17.
Ophthalmology ; 122(12): 2416-22, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26383992

RESUMO

PURPOSE: To investigate whether known genetic loci for primary open-angle glaucoma (POAG) are associated with visual field (VF) progression in patients from a Singaporean Chinese population. DESIGN: Retrospective study. PARTICIPANTS: Patients with 5 or more reliable VF measurements who were being followed up at a Singapore hospital. METHODS: Visual field progression was identified using Progressor software version 3.7 (Medisoft, Leeds, United Kingdom) and defined by pointwise linear regression (PLR) criteria as follows: any 2 contiguous points in the same hemifield progressing (≤-1.00 dB/year for inner points and ≤-2.00 dB/year for edge points; P < 0.01). Single nucleotide polymorphisms (SNPs) and their proxies from 10 POAG-associated loci (CAV1-CAV2, CDKN2B-AS1, SIX1-SIX6, an intergenic region on chromosome 8q22, ABCA1, GAS7, AFAP1, GMDS, PMM2, and TGFBR3-CDC7) identified from genome-wide association studies were tested for association with VF progression using logistic regression with an additive genetic model adjusting for age, gender, average intraocular pressure (IOP), central corneal thickness (CCT), and baseline vertical cup-to-disc ratio (VCDR). MAIN OUTCOME MEASURE: Visual field progression. RESULTS: Of the 1334 patients included in the study, 469 subjects (35.1%) completed 5 or more reliable VF measurements (mean follow-up, 9.01 years; standard deviation, 5.00 years). The mean age of patients was 59.6 years (standard deviation, 9.0 years); 305 patients were men and all were Chinese. The average IOP in eyes fulfilling PLR progression was 16.5 mmHg versus 17.7 mmHg in those who did not (P = 0.52). Univariate analysis revealed that increased VCDR (P = 0.003), reduced CCT (P = 0.045), and reduced superior and inferior retinal nerve fiber layer thickness (P = 0.01, respectively) were associated with VF progression. No clinical or structural features were associated significantly with VF progression on multivariate analysis. The rs1192415 index SNP in TGFBR3-CDC7 (P = 0.002; odds ratio, 6.71 per risk allele) was the only SNP associated with VF progression. CONCLUSIONS: The presence of the index SNP rs1192415 (TGFBR3-CDC7) was associated with VF progression in POAG patients. These findings warrant further investigation in independent cohorts.


Assuntos
Proteínas de Ciclo Celular/genética , DNA Intergênico/genética , Glaucoma de Ângulo Aberto/genética , Polimorfismo de Nucleotídeo Único , Proteínas Serina-Treonina Quinases/genética , Proteoglicanas/genética , Receptores de Fatores de Crescimento Transformadores beta/genética , Transtornos da Visão/diagnóstico , Campos Visuais , Idoso , Cromossomos Humanos Par 8/genética , Córnea/patologia , Paquimetria Corneana , Progressão da Doença , Feminino , Seguimentos , Marcadores Genéticos/genética , Técnicas de Genotipagem , Glaucoma de Ângulo Aberto/diagnóstico , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Singapura , Tonometria Ocular , Testes de Campo Visual
18.
Graefes Arch Clin Exp Ophthalmol ; 252(7): 1127-32, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24781879

RESUMO

PURPOSE: To assess variations in the iridocorneal angle width and iris volume in Chinese subjects using swept-source optical coherence tomography (SS-OCT). METHODS: Consecutive subjects, aged 40-80 years, with no previous ophthalmic problems were recruited from a population-based study of Chinese Singaporeans. All subjects underwent 360° SS-OCT (SS-1000 CASIA, Tomey Corporation, Nagoya, Japan) angle imaging and gonioscopy in one randomly selected eye in the dark. For each eye, 16 frames (11.25° apart) were selected for analysis from 128 cross-sectional images, and measurements of the trabecular iris space area 750 µm from the scleral spur (TISA750) and iris volume were made for each image. The measurements from four consecutive frames were further averaged as a sector of 45°. Sector-wise angle width and quadrant-wise iris volume were analyzed. RESULTS: Two hundred and twelve subjects (90 with closed-angles) were examined. The majority of the subjects were female (70.7 %) with mean age 61 (±8.9) years. The TISA750 (mm(2)) of superior [0.101 (0.09)], inferior [0.105 (0.09)], superior-nasal [0.111 (0.09)] and superior-temporal [0.117 (0.09)] sectors were smaller compared with other sectors (P < 0.05). The nasal iris volume (mm(3)) was the smallest compared with other quadrants for the entire cohort [nasal 8.18 (1.2) < inferior 9.13 (1.3) < temporal 9.16 (1.2) < superior 9.33 (1.3), P < 0.001], as well as for open- and closed-angle groups. CONCLUSIONS: The irido-corneal angle was narrower in the superior, inferior, superior-nasal and superior-temporal sectors compared with other sectors. Iris volume in the nasal quadrant was the smallest compared with the other quadrants.


Assuntos
Povo Asiático/etnologia , Córnea/patologia , Glaucoma de Ângulo Fechado/patologia , Glaucoma de Ângulo Aberto/patologia , Iris/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Glaucoma de Ângulo Fechado/etnologia , Glaucoma de Ângulo Aberto/etnologia , Gonioscopia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Singapura/epidemiologia , Tomografia de Coerência Óptica , Tonometria Ocular , Malha Trabecular/patologia
19.
Ophthalmol Glaucoma ; 7(1): 8-15, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37437884

RESUMO

PURPOSE: To assess the performance and generalizability of a convolutional neural network (CNN) model for objective and high-throughput identification of primary angle-closure disease (PACD) as well as PACD stage differentiation on anterior segment swept-source OCT (AS-OCT). DESIGN: Cross-sectional. PARTICIPANTS: Patients from 3 different eye centers across China and Singapore were recruited for this study. Eight hundred forty-one eyes from the 2 Chinese centers were divided into 170 control eyes, 488 PACS, and 183 PAC + PACG eyes. An additional 300 eyes were recruited from Singapore National Eye Center as a testing data set, divided into 100 control eyes, 100 PACS, and 100 PAC + PACG eyes. METHODS: Each participant underwent standardized ophthalmic examination and was classified by the presiding physician as either control, primary angle-closure suspect (PACS), primary angle closure (PAC), or primary angle-closure glaucoma (PACG). Deep Learning model was used to train 3 different CNN classifiers: classifier 1 aimed to separate control versus PACS versus PAC + PACG; classifier 2 aimed to separate control versus PACD; and classifier 3 aimed to separate PACS versus PAC + PACG. All classifiers were evaluated on independent validation sets from the same region, China and further tested using data from a different country, Singapore. MAIN OUTCOME MEASURES: Area under receiver operator characteristic curve (AUC), precision, and recall. RESULTS: Classifier 1 achieved an AUC of 0.96 on validation set from the same region, but dropped to an AUC of 0.84 on test set from a different country. Classifier 2 achieved the most generalizable performance with an AUC of 0.96 on validation set and AUC of 0.95 on test set. Classifier 3 showed the poorest performance, with an AUC of 0.83 and 0.64 on test and validation data sets, respectively. CONCLUSIONS: Convolutional neural network classifiers can effectively distinguish PACD from controls on AS-OCT with good generalizability across different patient cohorts. However, their performance is moderate when trying to distinguish PACS versus PAC + PACG. FINANCIAL DISCLOSURES: The authors have no proprietary or commercial interest in any materials discussed in this article.


Assuntos
Aprendizado Profundo , Glaucoma de Ângulo Fechado , Humanos , Pressão Intraocular , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Glaucoma de Ângulo Fechado/diagnóstico
20.
Transl Vis Sci Technol ; 13(2): 6, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38329749

RESUMO

Purpose: To determine the efficiency, precision, and agreement of GlauCAT-Asian and its corresponding validity and reliability. Methods: In this cross-sectional study, 219 participants (mean ± standard deviation age, 66.59 ± 8.61 years; 34% female) across the spectrum of glaucoma severity and 50 glaucoma suspects were recruited from glaucoma clinics in Singapore. Participants answered seven computerized adaptive testing (CAT) evaluations (Ocular Comfort, Activity Limitation, Lighting, Mobility, Concerns, Psychosocial, Glaucoma Management) and underwent eye examinations. Efficiency (mean number of items required for each CAT and time taken for CAT versus full item banks [IBs]), agreement (concordance between CATs and full IB person measures, henceforth referred to as scores), and precision (standard error of measurement [SE]) were evaluated. Other validity and reliability metrics were also assessed. Results: The mean number of items administered ranged from 9 (Mobility/Glaucoma Management) to 12 (Ocular Comfort). Compared to answering the full IBs, CATs provided an average time saving of 38.3% (range, 10% to 70.6% for Lighting and Activity Limitation, respectively). Agreement between scores obtained by CAT versus full IB was high (intracorrelation coefficient ≥0.75), as was precision of score estimates (mean SE range: 0.35 for Psychosocial to 0.29 for Mobility). Scores from Activity Limitation, Mobility, Lighting, and Concerns decreased significantly as glaucoma severity increased (criterion validity; P-trend <0.05). All tests displayed good convergent/divergent validity and test-retest reliability. Conclusions: GlauCAT-Asian provides efficient, precise, accurate, valid, and reliable measurement of the patient-centered impact of glaucoma. Translational Relevance: GlauCAT-Asian may provide a valuable clinical tool for ophthalmologists to monitor impact of disease progression and the effectiveness of therapies.


Assuntos
Glaucoma , Qualidade de Vida , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Transversais , Reprodutibilidade dos Testes , Glaucoma/diagnóstico , Olho
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa