Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
Mais filtros

Eixos temáticos
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 95(5): E144-E145, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32294334

RESUMO

Limited information is available about the performance of bioabsorbable-polymer drug-eluting stents in the setting of acute myocardial infarction. Patients treated with these stents presenting with acute myocardial infarction are at higher risk of adverse events compared with stable patients. Further clinical trials are needed to fully understand the role of bioabsorbable-polymer drug-eluting stents in patients presenting with acute myocardial infarction.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Implantes Absorvíveis , Humanos , Polímeros , Sistema de Registros , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 96(7): 1531-1532, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33306880

RESUMO

TAVR acute recoil has not been properly assessed with current generation balloon-expandable prosthesis. Acute recoil was greater during initial deployment than in postdilatation, in middle stent than inflow or outflow, and in antero-posterior than lateral axis. No predictors or clinical implications of acute valvular recoil were detected, calling for further research to better understand this phenomenon.


Assuntos
Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Dilatação , Humanos , Stents , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 96(5): 1044-1045, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33156968

RESUMO

The retrograde approach is needed to increase procedural success in chronic total occlusion angioplasty. This systematic review of the literature demonstrated that retrograde approach is associated with more complex anatomy, worse in-hospital and long-term outcomes. Retrograde approach needs expertise, used judiciously, and major focus in patient safety when performed.


Assuntos
Oclusão Coronária , Angioplastia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Humanos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 93(2): 354-355, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30719856

RESUMO

Transcatheter aortic valve replacement has been used successfully to treat native aortic valve regurgitation. Current observational evidence shows promising results in terms of procedural success while outcome data are difficult to interpret given the observational nature of the evidence. We are ready for a randomized trial, which will be very challenging to run.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 93(3): E191-E192, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30770665

RESUMO

There is limited data regarding percutaneous ventricular support in chronic total occlusion angioplasty in terms of population, procedure, and outcomes. This is the largest report to date showing promising results in terms of technical and procedural success in this highly comorbid population. This study encourages more research in the area and its use in large volume and experienced centers.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária , Doença Crônica , Humanos , Estudos Retrospectivos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 93(4): 739, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30859731

RESUMO

This study shows excellent transcatheter aortic valve replacement hemodynamic mid-term durability, aligned with prior research up to 5-years. Long-term (10+ years) data are needed before treating young low-risk people with aortic stenosis. Data so far are excellent, indicating a prosperous future for this procedure in young patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 93(7): 1288-1289, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31172679

RESUMO

Current transradial access (TRA) practices are unknown in the United States and the rest of the world. There is a decline in preprocedure collateral assessment, low use of ultrasound, and infrequent radial patency check after hemostasis. Significant knowledge-practice gaps exist in TRA calling for more dissemination and education.


Assuntos
Artéria Radial , Pesquisa Translacional Biomédica , Hemostasia , Inquéritos e Questionários , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 92(5): 852-853, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30450705

RESUMO

Japanese participants experienced higher incidence of radial artery occlusion when compared to non-Japanese participants. The use of 6Fr Slender sheath was inferior for radial artery occlusion than 5Fr sheath in Japanese, but no different in non-Japanese participants. Is not clear if this apparent ethnical interaction is real versus confounded, warranting more research in the area.


Assuntos
Etnicidade , Artéria Radial , Angiografia Coronária , Hemostasia , Humanos , Japão
12.
Catheter Cardiovasc Interv ; 89(6): 964-965, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28488410

RESUMO

Early hospital readmissions after percutaneous coronary interventions (PCI) are common and costly. From the NCDR CathPCI Registry and the Centers for Medicare and Medicaid Services, a risk prediction model was generated using 14 clinical variables, demonstrating modest discrimination. Future research is needed to identify interventions aim to reduce early readmissions. The use of this risk model may help guide these interventions.


Assuntos
Readmissão do Paciente , Intervenção Coronária Percutânea , Humanos , Medicare , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
13.
Catheter Cardiovasc Interv ; 90(5): 733-734, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29105331

RESUMO

In current PCI practice, anticoagulation with either bivalirudin or unfractionated heparin in patients with ACS share comparable efficacy and safety. Nonetheless, their individual performance in patients on dialysis remains unclear. This observational PCI study reported in-hospital clinical outcome in patients on dialysis undergoing PCI according to drug regimen: bivalirudin versus heparin. Similar clinical outcome was observed with both drug regimens.


Assuntos
Heparina , Intervenção Coronária Percutânea , Anticoagulantes , Antitrombinas , Planos de Seguro Blue Cross Blue Shield , Hirudinas , Humanos , Michigan , Fragmentos de Peptídeos , Proteínas Recombinantes , Diálise Renal , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 89(7): 1205-1206, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28612416

RESUMO

Diabetes mellitus (DM) is a multisystem disorder and a recognized risk factor for coronary artery disease (CAD) and DM patient are particularly challenging for revascularization. In this "real world" retrospective study post-PCI DM patients showed a high risk profile compared to the non-DM group, given by the higher prevalence of cardiovascular risk factors, multiple vessel disease, and renal dysfunction, with the highest rates seen in the ITDM. Only ITDM patients present higher 30-day mortality compared to non-DM patients in the urgent and primary PCI setting. Also ITDM, but not those NITDM patients, had an increased long-term mortality in the overall cohort and in all PCI setting.


Assuntos
Doenças Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Intervenção Coronária Percutânea , Humanos , Insulina , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 89(1): 24-25, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28116868

RESUMO

Unprotected distal left main (ULM) lesions often require double-stenting. In the MITO Registry, a mini-crush stenting technique was safer than culotte stenting. Performing mini-crush arises as the best approach in patients with distal ULM lesions requiring elective double-stenting.


Assuntos
Angiografia Coronária , Estimativa de Kaplan-Meier , Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Stents , Fatores de Tempo , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 90(2): 223-224, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28805034

RESUMO

Compared to balloon predilation, direct stenting (DS) shortens procedural time and reduces radiation and contrast exposure. A meta-analysis that included 7 studies comparing these 2 strategies revealed lower adverse event rate with DS. Studies included in the present meta-analysis were mostly observational and utilized first generation drug-eluting stent. Patient and lesion selection may explain these positive results.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Angiografia Coronária , Humanos , Stents , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 89(5): 818-819, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28419789

RESUMO

Overlapping permanent scaffolds carries a long-term risk of target vessel failure due to late malapposition and the development of neoatherosclerosis. Potentially, overlapping bioresorbable scaffold (BRS) may lead to lower long-term risk. The GHOST-EU registry reported similar short- and mid-term risks in patients with and without BRS overlap. Larger size studies with longer follow-up are needed to confirm the safety of BRS overlap.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Humanos , Intervenção Coronária Percutânea , Alicerces Teciduais , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 88(7): 1075-1076, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27976543

RESUMO

Aorto-ostial lesions (AOLs) entail several diagnostic and treatment challenges. The Flash Ostial System enables flaring of the overhanging stent, optimizing stent deployment in AOLs. Careful planning is essential to achieve optimal stent implantation and avoid early and late complications during the treatment of AOLs.


Assuntos
Stents , Resultado do Tratamento , Humanos
20.
Catheter Cardiovasc Interv ; 87(3): 532-3, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26919346

RESUMO

Acute kidney injury (AKI) is frequently observed immediately after transcatheter aortic valve implantation (TAVI). Both classifications, the RIFLE (the Risk, Injury, Failure, Loss, and End-stage Kidney) and the KDIGO (Kidney Disease: Improving Global Outcomes) from the VARC-2 (Valve Academic Research Consortium-2) are fairly interchangeable and performed well as clinical predictors of all-cause mortality. Patients with baseline reduced glomerular filtration rate (GFR) or known atherosclerotic arterial disease are at increased risk of AKI.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Injúria Renal Aguda , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa