Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Med (Hagerstown) ; 20(4): 169-179, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30829875

RESUMO

AIMS: Atrial fibrillation incidence is increasing due to ageing population and electrical cardioversion (ECV) is overused because of atrial fibrillation recurrences. Study's aim was to evaluate value of novel three-dimensional echocardiographic-derived left atrial conduit (LAC) function quantification in predicting early atrial fibrillation recurrence after ECV. METHODS: We included 106 patients [74 (64-78) years] who underwent ECV for persistent nonvalvular atrial fibrillation. For all clinical data and simultaneous left atrial and left ventricular (LV) three-dimensional full-volume data sets were available before ECV. We computed LAC as: [(LV maximum - LV minimum) - (left atrial maximum - left atrial minimum) volume], expressed as % LV stroke volume. Atrial fibrillation recurrence was checked with Holter monitoring. RESULTS: One month after ECV 66 patients were in sinus rhythm and 40 experienced atrial fibrillation recurrence. Pre-ECV patients with atrial fibrillation recurrence showed higher LAC contribution to LV filling (P < 0.0001) and noninvasively estimated left atrial stiffness (P < 0.0001) compared with sinus rhythm patients. There were no other differences, neither in clinical characteristics nor in LV properties. At multivariate LAC (P < 0.001), left atrial stiffness (P = 0.002) and volume (P = 0.043) predicted early atrial fibrillation relapse, even when compared with other confounding factors. Receiver-operating characteristics area (ROC) analysis confirmed LAC as best atrial fibrillation recurrence predictor (0.84, P < 0.0001), cut-off value more than 54% exhibiting reasonable sensibility-specificity (76-75%). CONCLUSION: Atrial fibrillation makes LV filling dependent on reciprocation between left atrial reservoir/conduit phases. Our data suggest that LAC larger contribution to filling in persistent atrial fibrillation patients reflects left atrial and LV diastolic dysfunction, which skews atrio-ventricular interaction that leads to atrial fibrillation perpetuation, making LAC a powerful atrial fibrillation recurrence predictor after ECV.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Função do Átrio Esquerdo , Ecocardiografia Tridimensional , Cardioversão Elétrica , Átrios do Coração/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
2.
Int J Cardiovasc Imaging ; 34(7): 1099-1107, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29484557

RESUMO

Successful mitral valve (MV) repair for degenerative mitral regurgitation (DMR) is mainly related to surgical expertise and MV anatomy. Although 2D echocardiography, specifically transoesophageal (TOE), provides precise information regarding MV anatomy, recent advancements in matrix technology meant a decisive step forward to the point where segmental MV analysis can be accurately performed from a noninvasive 3D transthoracic (TTE) approach. The aims of this study were: (a) to evaluate the feasibility and time required for real-time 3D TTE in a large consecutive cohort of patients with severe DMR in the assessment of MV anatomy; (b) to compare the accuracy of 3D TTE and 2D TOE versus surgical inspection in the recognition and localization of all components of the MV leaflets; (c) to establish the added diagnostic value of 3D colourDoppler examination to pure 3D morphologic evaluation. 149 consecutive patients with severe DMR underwent complete 3D TTE before surgery and 2D TOE in the operating room. Echocardiographic data obtained by the different techniques were compared with surgical inspection. 3D TTE was feasible in a relatively short time (8 ± 4 min), with good (49%) and optimal (33%) imaging quality in the majority of cases. 3D TTE had significant better overall accuracy compared to 2D TOE (93 and 91%, p < 0.05, respectively). 2D TOE was significantly more specific than 3D TTE in the identification of A3 prolapse (99 vs. 96%). The colourDoppler mode did not improve significantly the accuracy of 3D TTE, albeit it determined a better sensitivity in the detection of A2 prolapse if compared to 2D TOE (95 vs. 85%). 3D TTE with or without colourDoppler is a feasible and useful method in the analysis of MV prolapse; it allows a preoperative and noninvasive description of the pathology as accurate as the 2D TOE.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Ecocardiografia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos
3.
J Cardiovasc Med (Hagerstown) ; 18(5): 325-331, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-26657083

RESUMO

AIMS: Coronary blood flow and diastolic function are well known to interfere with each other through mechanical and metabolic mechanisms. We aimed to assess the relationship between coronary flow reserve (CFR) and diastolic dysfunction in patients suffering from angina but with normal coronary angiography. METHODS: In 16 patients with chest pain and angiographically normal coronary arteries, CFR was measured using transthoracic echo-Doppler by inducing hyperemia through dipyridamole infusion. Diastolic function (E/A, deceleration time, isovolumetric relaxation time [IVRT], propagation velocity [Vp]) and left ventricular mass were evaluated by means of two-dimensional transthoracic echocardiography. RESULTS: The patients were initially divided into two groups on the grounds of CFR only (ACFR: altered CFR, n = 9; NACFR: unaltered CFR, n = 7). Thereafter they were divided into four groups on the grounds of CFR and diastolic function (NN: normal; AA: altered CFR/diastole; AN: altered CFR/normal diastole; NA: normal CFR/altered diastole). Most of the subjects were scheduled in AA (n = 8) or NA (n = 5) groups, which were taken into consideration for further analysis. Patients were not different regarding various risk factors. ACFR and AA patients were older with normal body weight in comparison with NACFR and NA patients (P < 0.05). In the AA group, CFR and diastolic variables were found to be related to each other. CONCLUSION: Diastolic dysfunction and reduced CFR were correlated in patients with concomitant alterations of those variables only. Because most risk factors were shared with patients with altered diastolic properties only, our findings could represent a direct relationship between altered CFR and diastole.


Assuntos
Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler , Reserva Fracionada de Fluxo Miocárdico , Microcirculação , Angina Microvascular/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Vasos Coronários/fisiopatologia , Diástole , Dipiridamol/administração & dosagem , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Angina Microvascular/fisiopatologia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco , Vasodilatadores/administração & dosagem
4.
G Ital Cardiol (Rome) ; 15(5): 330-4, 2014 May.
Artigo em Italiano | MEDLINE | ID: mdl-25002174

RESUMO

Ventricular septal defect is a rare but potentially fatal complication of acute myocardial infarction. It usually occurs during the first episode of myocardial infarction, most often in patients with single vessel coronary artery disease and total occlusion of the culprit vessel, in the absence of an adequate collateral circulation. However, this complication is observed in patients with myocardial infarction with normal coronary arteries and its pathogenesis may be attributed to different mechanisms such as inflammation, hypercoagulable state or coronary vasospasm. We report the case of a 59-year-old female patient with anteroseptal myocardial infarction developed 4 days after admission, complicated by ventricular septal defect with signs of congestive heart failure and angiographically normal coronary arteries.


Assuntos
Infarto Miocárdico de Parede Anterior/complicações , Infarto Miocárdico de Parede Anterior/diagnóstico , Vasos Coronários/diagnóstico por imagem , Ruptura do Septo Ventricular/diagnóstico , Ruptura do Septo Ventricular/etiologia , Infarto Miocárdico de Parede Anterior/fisiopatologia , Angiografia Coronária/métodos , Ecocardiografia , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Pessoa de Meia-Idade , Fatores de Tempo , Ruptura do Septo Ventricular/complicações
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa