Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Pediatr Cardiol ; 41(4): 772-780, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32034462

RESUMO

Coarctation of the aorta (COA) is suspected prenatally when there is ventricular asymmetry, arterial disproportion, and hypoplasia of the aortic arch/isthmus. The presence of fetal shunts creates difficulty in prenatal confirmation of the diagnosis so serial echocardiography after birth is necessary to confirm or refute the diagnosis. The first neonatal echocardiogram in prenatally suspected cases of COA was assessed for prediction of neonatal COA repair (NCOAR). This included morphological assessment, measurement of the aortic arch and calculation of the distal arch index (DAI = distance between left common carotid and left subclavian artery/diameter of the distal arch). NCOAR was undertaken in 23/60 (38%) cases. Transverse arch, aortic isthmus z-score, and DAI had an area under the receiver operator curve of 0.88 (95% CI 0.77-0.98), 0.86 (95% CI 0.75-0.96), and 0.84 (95% CI 0.74-0.95), respectively for the prediction of NCOAR. Using transverse arch z-score threshold < - 3 gave sensitivity 100%, NPV: 100%, specificity 76%; aortic isthmus z-score < - 3: NPV 92%, specificity 62% and DAI > 1.4: NPV 88%, specificity 78%. The size of the distal aortic arch in infants with a common origin of the innominate artery and left common carotid artery who did not require COA repair was similar to the NCOAR cases (p = 0.22). The early postnatal assessment of the size and morphology of the aortic arch can assist in risk stratification for development of neonatal COA. The branching pattern of the head/neck vessels impacts on the size of the distal aortic arch adding to the complexity of predicting COA based on vessel size.


Assuntos
Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Aorta Torácica/patologia , Coartação Aórtica/patologia , Feminino , Coração Fetal/diagnóstico por imagem , Coração Fetal/patologia , Humanos , Lactente , Recém-Nascido , Valor Preditivo dos Testes , Gravidez
2.
Echocardiography ; 34(4): 587-593, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28191731

RESUMO

BACKGROUND: Quantitative echocardiographic assessment of right ventricular function is important in children with hypoplastic left heart syndrome (HLHS). The aim of this study was to examine the repeatability of different echocardiographic techniques, both manual and automated, to measure fractional area change (FAC) in patients with HLHS and to correlate these measurements with magnetic resonance imaging (MRI)-derived ejection fraction (EF). METHODS: Fifty-one children with HLHS underwent transthoracic echocardiography and cardiac MRI under the same general anesthetic as part of routine inter-stage assessment. FAC was measured from the apical four-chamber view using three different techniques: velocity vector imaging (VVI) (Syngo USWP 3.0; Siemens Healthineers), QLAB (Q-lab R 10.0; Philips Healthcare), and manual endocardial contour tracing (Xcelera, Philips Healthcare). Intra- and inter-observer variability was calculated using intra-class correlation coefficient (ICC). FAC was correlated with MRI EF calculated using a single standard method. RESULTS: Fractional area change had a good correlation with MRI-derived EF with an R value for VVI, QLAB, and manual methods of .7, .6, and .4, respectively. Intra- and inter-observer variability for FAC was good for automated echocardiographic methods (ICC>.85) but worse for manual method particularly inter-observer variability of FAC and end-systolic area. Both automated techniques tended to produce higher FAC values compared with manual measurements (P<.001). CONCLUSION: Automation improves the repeatability of FAC in HLHS. There are some differences between automated software in terms of correlation with MRI-derived EF. Measurement bias and wide limits of agreement mean that the same echocardiographic technique should be used during the follow-up of individual patients.


Assuntos
Ecocardiografia/métodos , Síndrome do Coração Esquerdo Hipoplásico/complicações , Processamento de Imagem Assistida por Computador/métodos , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Lactente , Imageamento por Ressonância Magnética , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Software , Disfunção Ventricular Direita/fisiopatologia
3.
Cardiol Young ; 27(1): 131-138, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27055807

RESUMO

Introduction The hybrid procedure is one mode of initial palliation for hypoplastic left heart syndrome. Subsequently, patients proceed with either the "three-stage" pathway - comprehensive second stage followed by Fontan completion - or the "four-stage" pathway - Norwood procedure, hemi-Fontan, or Fontan completion. In this study, we describe somatic growth patterns observed in the hybrid groups and a comparison primary Norwood group. METHODS: A retrospective analysis of patients who have undergone hybrid procedure and Fontan completion was performed. Weight-for-age and height-for-age z-scores were recorded at each operation. RESULTS: We identified 13 hybrid patients - eight in the three-stage pathway and five in the four-stage pathway - and 49 Norwood patients. Weight: three stage: weight decreased from hybrid procedure to comprehensive second stage (-0.4±1.3 versus -2.3±1.4, p<0.01) and then increased to Fontan completion (-0.4±1.5 versus -0.6±1.4, p<0.01); four stage: weight decreased from hybrid procedure to Norwood (-2.0±1.4 versus -3.3±0.9, p=0.06), then stabilised to hemi-Fontan. Weight increased from hemi-Fontan to Fontan completion (-2.7±0.6 versus -1.0±0.7, p=0.01); primary Norwood group: weight decreased from Norwood to hemi-Fontan (p<0.001) and then increased to Fontan completion (p<0.001). Height: height declined from hybrid procedure to Fontan completion in the three-stage group. In the four-stage group, height decreased from hybrid to hemi-Fontan, and then increased to Fontan completion. The Norwood group decreased in height from Norwood to hemi-Fontan, followed by an increase to Fontan completion. CONCLUSION: In this study, we show that patients undergoing the hybrid procedure have poor weight gain before superior cavopulmonary connection, before returning to baseline by Fontan completion. This study identifies key periods to target poor somatic growth, a risk factor of morbidity and worse neurodevelopmental outcomes.


Assuntos
Desenvolvimento Infantil/fisiologia , Técnica de Fontan/métodos , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Procedimentos de Norwood/métodos , Cuidados Paliativos , Feminino , Seguimentos , Humanos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Masculino , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
4.
J Cardiovasc Magn Reson ; 17: 28, 2015 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-25890289

RESUMO

BACKGROUND: Selection of patients with congenital heart disease for surgical septation in biventricular repair or surgical palliation in functionally single ventricles requires low pulmonary vascular resistance (PVR). Where there is uncertainty, PVR can be assessed using hybrid cardiovascular magnetic resonance (CMR) and fluoroscopic (X-Ray) guided cardiac catheterizations (XMR). CMR/XMR catheterization is a validated technique for accurate assessment of pulmonary vascular resistance. However, data concerning its application in clinical practice is lacking. METHODS: PVR assessments were performed in 167 studies in 149 congenital heart disease patients by CMR/XMR catheterization. Data was collated on patient demographics, procedural data, complications and outcomes. Institutional ethics approval was obtained. RESULTS: Median age was 3.6 years (6 days-67 years) and weight 13.8 kg (2.3-122 kg). One hundred and eight studies were in biventricular circulations and 59 in functionally single ventricles. Median radiation dose was 0.72 mSv. A baseline Qp:Qs ≤2.75 in biventricular circulations with left-to-right shunts predicted a PVR ≥6 WU x m(2) with 100% sensitivity and 48% specificity. Median follow up until death or last review was 4.2 years (4 days-11 years). Eighty-four patients had a surgical or catheter intervention based on CMR/XMR catheterization findings at a median of 94 days after the study. This included successful biventricular repair at resting PVR values ≤6 WU x m(2) and Fontan completion at ≤4 WU x m(2). CONCLUSION: PVR measured by CMR/XMR catheterization allows accurate stratification for intervention in patients with congenital heart disease in both, biventricular and univentricular circulations.


Assuntos
Cateterismo de Swan-Ganz/métodos , Cardiopatias Congênitas/diagnóstico , Imagem por Ressonância Magnética Intervencionista , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Resistência Vascular , Adolescente , Adulto , Idoso , Pressão Arterial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Radiografia Intervencionista , Fatores de Risco , Adulto Jovem
5.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35640135

RESUMO

OBJECTIVES: There is increasing evidence that performing superior cavopulmonary connection (SCPC) at 3 months reduces mortality: reducing the risky 'interstage' period, volume off-loading the ventricle and reducing coronary steal, hopefully preserving ventricular function. Our objective was to describe our experience of early SCPC with preoperative computer tomography (CT) assessment compared to later connection at 6 months. METHODS: Patients undergoing Norwood procedure from 2005 to 2020 were divided into 2 eras were described and compared. Era 1 from 2005 to 2016 when SCPC was undertaken at 6 months: and era 2 (2017-2020) when an earlier operation was performed. Demographics, mortality (interstage, early and late following SCPC) and data on postoperative course and complications were recorded. RESULTS: In era 1, 191 patients underwent Norwood (120 survivors to SCPC) and 28 patients (23 survivors) in era 2. There were no significant differences in the demographics. Interstage mortality was 17.8% in era 1 and 8.0% in era 2 but not significantly significant (P = 0.22). The median (interquartile range) age at pre-imaging and SCPC was significantly lower: 99 (81-120) vs 77 (47-102) days and 175 (117-208) vs 106 (102-122) days in era 1 vs era 2 (P < 0.005). Weight was lower at SCPC in era 2 [mean (standard deviation) 6.2 kg (1.2) vs 5.1 kg (0.8), P < 0.05]. Intubation time and total length of stay were not statistically different. Median intensive care unit stay was statistically significantly longer, but not clinically significant: 2.5 (2-4) vs 3 (3-5) days, respectively (P < 0.05). There was no significant difference in early or late mortality, rates of diagnostic or interventional catheter, postoperative magnetic resonance imaging/CT or stroke. Logistic regression analysis demonstrates increasing age at SCPC was associated with increased chance of stroke or early death (P = 0.043). CONCLUSIONS: Early SCPC with CT assessment is feasible and although intensive care unit length of stay was slightly longer there was no change in the overall length of stay and no change in postoperative mortality or complications.


Assuntos
Síndrome do Coração Esquerdo Hipoplásico , Procedimentos de Norwood , Acidente Vascular Cerebral , Computadores , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Procedimentos de Norwood/efeitos adversos , Procedimentos de Norwood/métodos , Cuidados Paliativos/métodos , Estudos Retrospectivos , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Echo Res Pract ; 6(3): 63-70, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31413860

RESUMO

BACKGROUND: The Technical Performance Score (TPS) developed by Boston Children's Hospital showed surgical outcomes correlate with adequacy of technical repair when implemented on pre-discharge echocardiograms. We applied this scoring system to intraoperative imaging in a tertiary UK congenital heart surgical centre. METHODS: After a period of training, intraoperative TPS (epicardial and/or transesophageal echocardiography) was instituted. TPS was used to inform intraoperative discussions and recorded on a custom-made database using the previously published scoring system. After a year, we reviewed the feasibility, results and relationship between the TPS and mortality, extubation time and length of stay. RESULTS: From 01 September 2015 to 04 July 2016, there were 272 TPS procedures in 251 operations with 208 TPS recorded. Seven patients had surgery with no documented TPS, three had operations with no current TPS score template available. Patients left the operating theatre with TPS optimal in 156 (75%), adequate 34 (16%) and inadequate 18 (9%). Of those with an optimal score on leaving theatre, ten had more than one period of cardiopulmonary bypass. All four deaths <30 days after surgery (1.9%) had optimal TPS. There was a statistically significant difference in extubation times in the RACHS category 4 patients (3 days vs 5 days, P < 0.05) and in PICU and total length of stay in the RACHS category three patients (2 and 8 days vs 12.5 and 21.5 days respectively) if leaving theatre with an inadequate result. CONCLUSIONS: Application of intraoperative TPS is feasible and provides a way of objectively recording intraoperative imaging assessment of surgery. An 'inadequate' TPS did not predict mortality but correlated with a longer ventilation time and longer length of stay compared to those with optimal or adequate scores.

7.
Eur Heart J Cardiovasc Imaging ; 17(6): 644-51, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26188193

RESUMO

AIMS: Exercise limitation is common post-Fontan. Hybrid X-ray and magnetic resonance imaging (XMR) catheterization allows haemodynamic assessment by means of measurement of ventricular volumes and flow in major vessels with simultaneous invasive pressures. We aim to assess haemodynamic response to stress in patients with hypoplastic left heart syndrome (HLHS) post-Fontan. METHODS AND RESULTS: Prospective study of 13 symptomatic children (NHYA 2) with HLHS post-Fontan using XMR catheterization. Three conditions were applied: baseline (Stage 1), dobutamine at 10 µg/kg/min (Stage 2), and dobutamine at 20 µg/kg/min (Stage 3). Seven consecutive patients received inhaled nitric oxide (iNO) at peak stress. Control MRI data were from normal healthy adults. In the HLHS patients, baseline mean pulmonary vascular resistance (PVR) was 1.51 ± 0.59 WU m(2) and aortopulmonary collateral flow was 17.7 ± 13.6% of systemic cardiac output. Mean right ventricular end-diastolic pressure was 6.7 ± 2.5 mmHg which did not rise with stress. Cardiac index (CI) increased at Stage 2 in HLHS (40%) and controls (61%) but continued to increase at Stage 3 only in controls (19%) but not in HLHS. The blunted rise in CI in HLHS was due to a continuing fall in end-diastolic volume throughout stress, with no significant change in PVR or CI at peak stress in response to iNO. CONCLUSION: Cardiac output post-Fontan in HLHS at peak stress is blunted due to a limitation in preload which is not responsive to inhaled pulmonary vasodilators in the setting of normal PVR.


Assuntos
Ecocardiografia sob Estresse , Técnica de Fontan/métodos , Hemodinâmica/fisiologia , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Resistência Vascular/fisiologia , Fatores Etários , Análise de Variância , Cateterismo Cardíaco/métodos , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Técnica de Fontan/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Masculino , Monitorização Fisiológica/métodos , Prognóstico , Medição de Risco , Fatores Sexuais
8.
J Am Soc Echocardiogr ; 26(1): 52-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23098782

RESUMO

BACKGROUND: The geometry and heterogeneity of the right ventricle in hypoplastic left heart syndrome makes objective echocardiographic assessment of systolic function challenging. Consequently, subjective echocardiographic assessment of right ventricular (RV) function is still routinely undertaken. The aims of this study were to compare this with magnetic resonance imaging (MRI), investigate the impact of experience and training on the accuracy of subjective assessment, and critically analyze the role of echocardiography to detect impaired systolic function. METHODS: A retrospective analysis of prospectively acquired data was performed. Children with hypoplastic left heart syndrome underwent routine preoperative cardiac MRI and echocardiography under the same general anesthetic. Echocardiograms were reviewed, and members of the congenital heart disease team with differing echocardiography experience subjectively graded RV systolic function (good, moderate, or poor). This was compared with MRI-derived ejection fraction. RESULTS: Twenty-eight patients at different palliative stages were included. Twenty-eight observers were divided into five experience categories (congenital heart disease junior trainees to attending cardiologists). Median agreement was 47.6% (range, 31.4%-58.2%), with the lowest agreement among junior trainees and the highest among attending cardiologists. When used as a screening test for poor RV systolic function, the median sensitivity of echocardiography was 0.89 (range, 0.86-0.96), and median specificity was 0.45 (range, 0.26-0.55). The highest sensitivity was observed among junior trainees but with the lowest specificity. The highest specificity was observed among attending cardiologists (0.55). CONCLUSIONS: Agreement between echocardiographic and MRI RV ejection fraction improves with experience but remains suboptimal. When used as a screening test for poor RV function, echocardiography is sensitive, but specificity is heavily influenced by operator experience.


Assuntos
Ecocardiografia Doppler/métodos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Função Ventricular Direita/fisiologia , Pré-Escolar , Feminino , Seguimentos , Humanos , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Masculino , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Sístole
9.
J Am Coll Cardiol ; 61(5): 561-70, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23273398

RESUMO

OBJECTIVES: This study sought to investigate changes in magnetic resonance imaging (MRI) ventricular volumes and vascular dimensions before hemi-Fontan (HF) and before total cavopulmonary connection (TCPC) in children with hypoplastic left heart syndrome (HLHS). BACKGROUND: The systemic right ventricle (RV) in HLHS is subject to significant changes in volume loading throughout the surgical stages of palliation, particularly after the HF. METHODS: Fifty-eight patients had paired pre-HF and pre-TCPC MRI for assessment of changes of RV volumes, neoaortic flow, and vascular dimensions. RESULTS: Comparison of pre-HF and pre-TCPC MRI results showed a decrease of indexed RV end-diastolic volume and end-systolic volume (98 ml/m(2) to 87 ml/m(2) and 50 ml/m(2) to 36 ml/m(2), respectively) with stroke volume remaining constant (49 ml/m(2) vs. 51 ml/m(2)), leading to an increased RV ejection fraction (51% vs. 59%). These findings persisted after excluding the 3 patients who underwent tricuspid valve repair as part of their HF procedure. Indexed RV end-diastolic volume plotted against neoaortic stroke volume demonstrated a Frank-Starling-like curve that shifted upward after HF. The indexed distal left and right cross-sectional pulmonary artery areas were reduced after HF. CONCLUSIONS: In HLHS, serial MRI shows the adaptation of the systemic RV after HF with volume reduction in the context of a preserved stroke volume and an increased ejection fraction. The staged palliation in HLHS may be a risk factor particularly for reduced left pulmonary artery growth in itself as no factors investigated in this study were found to significantly impact on this.


Assuntos
Adaptação Fisiológica/fisiologia , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita/fisiologia , Remodelação Ventricular/fisiologia , Estudos de Coortes , Feminino , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Função Ventricular Esquerda/fisiologia
10.
Eur Heart J Cardiovasc Imaging ; 13(5): 400-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22157969

RESUMO

AIMS: To describe tissue Doppler time intervals and derived indices in hypoplastic left heart syndrome (HLHS) across surgical stages, taking account of age-related changes in the heart rate. Correlation of the myocardial performance index (MPI) and the systolic to diastolic (S:D) time ratio with other echocardiographic and magnetic resonance imaging (MRI) measures of cardiac performance. METHODS AND RESULTS: Fifty-seven patients at different stages of HLHS palliation were studied prospectively using tissue Doppler imaging of the right ventricular free wall, with simultaneous cardiac MRI in the majority. Both isovolumic contraction time and isovolumic relaxation time were prolonged compared with the normal left and right ventricle: median (range) z-scores for the tricuspid annulus 1.9 (-1.2 to 9.3) and 1.3 (-2.0 to 5.5), respectively. When adjusted for heart rate, the ejection, systolic, and diastolic times in HLHS were not significantly different from published normal data. The MPI was increased at all surgical stages in HLHS. Neither MPI nor heart rate-specific S:D time ratio z-score correlated with MRI ejection fraction or indexed cardiac output when the confounding effect of significant tricuspid regurgitation was taken into consideration. CONCLUSION: The prolongation in isovolumic relaxation and contraction times may be due to adaptation or reduced myocardial performance. Differences in the S:D time ratio between surgical stages can be accounted for by the heart rate alone. Neither MPI z-score nor S:D z-score correlated with MRI or other echocardiographic indices of systolic or diastolic function with the exception of a negative correlation between central venous pressure and S:D ratio z-score.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Ultrassonografia Doppler/instrumentação , Intervalos de Confiança , Estudos Transversais , Indicadores Básicos de Saúde , Cardiopatias Congênitas , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/patologia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Imageamento por Ressonância Magnética/instrumentação , Contração Miocárdica , Imagem de Perfusão do Miocárdio/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Estatística como Assunto , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa