1.
Diabetes Obes Metab ; 20(8): 2004-2008, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29577536

RESUMO

Glucose excursion was assessed prior to and post hypoglycaemia to increase understanding of hypoglycaemia incidence and recovery during hybrid closed-loop insulin delivery. We retrospectively analysed data from 60 adults with type 1 diabetes who received, in a crossover randomized design, day-and-night hybrid closed-loop insulin delivery and insulin pump therapy, the latter with or without real-time continuous glucose monitoring. Over 4-week study periods, we identified hypoglycaemic episodes, defined as sensor glucose <3.0 mmol/L, and analysed sensor glucose relative to the onset of hypoglycaemia. We identified 377 hypoglycaemic episodes during hybrid closed-loop intervention vs 662 during control intervention (P < .001), with a predominant reduction of nocturnal hypoglycaemia. The slope of sensor glucose prior to hypoglycaemia was steeper during closed-loop intervention than during control intervention (P < .01), while insulin delivery was reduced (P < .01). During both day and night, participants recovered from hypoglycaemia faster when treated by closed-loop intervention. At 120 minutes post hypoglycaemia, sensor glucose levels were higher during closed-loop intervention compared to the control period (P < .05). In conclusion, closed-loop intervention reduces the risk of hypoglycaemia, particularly overnight, with swift recovery from hypoglycaemia leading to higher 2-hour post-hypoglycaemia glucose levels.


Assuntos
Atividades Cotidianas , Diabetes Mellitus Tipo 1/terapia , Hipoglicemia/prevenção & controle , Pâncreas Artificial/efeitos adversos , Autogestão , Adulto , Glicemia/análise , Automonitorização da Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/epidemiologia , Hipoglicemia/etiologia , Hipoglicemia/terapia , Incidência , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Estudos Retrospectivos , Risco , Fatores de Tempo
2.
Diabetes Obes Metab ; 19(10): 1485-1489, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28371223

RESUMO

We aimed to evaluate the relationship between insulin pharmacodynamics and glycaemic outcomes during closed-loop insulin delivery and sensor-augmented pump therapy. We retrospectively analysed data from a multicentre randomized control trial involving 32 adults with type 1 diabetes receiving day-and-night closed-loop insulin delivery and sensor-augmented pump therapy over 12 weeks. We estimated time-to-peak insulin action (t max,IA ) and insulin sensitivity ( S I ) during both interventions, and correlated these with demographic factors and glycaemic outcomes. During both interventions, t max,IA was positively correlated with pre- and post-intervention HbA1c (r = 0.50-0.52, P < .01) and mean glucose (r = 0.45-0.62, P < .05), and inversely correlated with time sensor glucose, which was in target range 3.9 to 10 mmol/L (r = -0.64 to -0.47, P < .05). Increased body mass index was associated with higher t max,I and lower S I (both P < .05). During closed-loop insulin delivery, t max,IA was positively correlated with glucose variability ( P < .05). Faster insulin action is associated with improved glycaemic control during closed-loop insulin delivery and sensor-augmented pump therapy.


Assuntos
Técnicas Biossensoriais/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Técnicas Biossensoriais/métodos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Feminino , Humanos , Insulina/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
3.
J Diabetes Sci Technol ; 16(2): 408-414, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33563051

RESUMO

BACKGROUND: In automated glucose clamp experiments, blood glucose (BG) concentrations are kept close to a predefined target level using variable glucose infusion rates (GIRs) determined by implemented algorithms. Clamp quality (ie, the ability to keep BG close to target) highly depends on the quality of these algorithms. We developed a new Clamp algorithm based on the proportional-integral-derivative (PID) approach and compared clamp quality between this and the established Biostator (BS) algorithm. METHODS: In numerical simulations, the PID-based algorithm was optimized in silico. The optimized Clamp-PID algorithm was tested in in vitro experiments and finally validated in vivo in a small (n = 5) clinical study. RESULTS: In silico, in vitro, and in vivo experiments showed better clamp quality for the new Clamp-PID algorithm compared with the BS algorithm: precision and absolute control deviation (ACD) decreased from 3.7% to 1.1% and from 2.9 mg/dL to 0.6 mg/dL, respectively, in the numerical simulation. The in vitro validation demonstrated reductions in precision (from 3.3% ± 0.1% (mean ± SD) to 1.4% ± 0.4%) and in ACD (from 2.3 mg/dL ± 0.4 mg/dL to 0.8 mg/dL ± 0.2 mg/dL), respectively. In the clinical study, precision and ACD improved from 6.5% ± 1.3% to 4.0% ± 1.1% and from 3.6 mg/dL ± 0.9 mg/dL to 2.2 mg/dl ± 0.6 mg/dl, respectively. The quality parameter utility did not change. CONCLUSIONS: The new Clamp-PID algorithm improves the clamp quality parameters precision and ACD versus the BS algorithm.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Algoritmos , Glicemia , Técnica Clamp de Glucose , Humanos , Insulina/uso terapêutico
4.
J Diabetes Sci Technol ; 14(2): 277-283, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-30931606

RESUMO

OBJECTIVE: The objective was to describe a novel composite continuous glucose monitoring index (COGI) and to evaluate its utility, in adults with type 1 diabetes, during hybrid closed-loop (HCL) therapy and multiple daily injections (MDI) therapy combined with real-time continuous glucose monitoring (CGM). METHODS: COGI consists of three key components of glucose control as assessed by CGM: Time in range (TIR), time below range (TBR), and glucose variability (GV) (weighted by 50%, 35% and 15%). COGI ranges from 0 to 100, where 1% increase of time <3.9 mmol/L (<70 mg/dl) is equivalent to 4.7% reduction of TIR between 3.9-10 mmol/L (70-180 mg/dl), and 0.5 mmol/L (9 mg/dl) increase in standard deviation is equivalent to 3% reduction in TIR. RESULTS: Continuous subcutaneous insulin infusion (CSII) users with HbA1c >7.5-10%, had significantly higher COGI during 12 weeks of HCL compared to sensor-augmented pump therapy, mean (SD), 60.3 (8.6) versus 69.5 (6.9), P < .001. Similarly, in CSII users with HbA1c <7.5%, HCL improved COGI from 59.9 (11.2) to 74.8 (6.6), P < .001. In MDI users with HbA1c >7.5% to 9.9%, use of real-time CGM led to improved COGI, 49.8 (14.2) versus 58.2 (9.1), P < .0001. In MDI users with impaired awareness of hypoglycemia, use of real-time CGM led to improved COGI, 53.4 (12.2) versus 66.7 (11.1), P < .001. CONCLUSIONS: COGI summarizes three key aspects of CGM data into a concise metric that could be utilized to evaluate the quality of glucose control and to demonstrate the incremental benefit of a wide range of treatment modalities.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Controle Glicêmico , Indicadores Básicos de Saúde , Adulto , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Esquema de Medicação , Feminino , Hemoglobinas Glicadas/análise , Controle Glicêmico/métodos , Controle Glicêmico/normas , Humanos , Injeções Subcutâneas , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Monitorização Fisiológica/métodos , Prognóstico , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
5.
J Diabetes Sci Technol ; 13(4): 751-755, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30255710

RESUMO

BACKGROUND: One major advantage of automated over manual clamps are continuous measurements of blood glucose concentrations (BG) allowing frequent adaptations in glucose infusion rates (GIR). However, BG measurements might be affected by changes in blood dilution. ClampArt®, a modern automated clamp device, corrects BG measurements for blood dilution, but the impact of this correction is unclear. METHODS: The authors performed a retrospective analysis of BG during glucose clamps comparing values with a fixed dilution factor with those corrected for the actual blood dilution. RESULTS: Clamp quality substantially improved with the consideration of blood dilution: Mean accuracy fell from 8.1% ± 2.9% to 4.1% ± 0.8%, precision improved from 9.6 ± 3.6 mg/dl to 3.7 ± 1.3 mg/dl and control deviation from -2.6 ± 4.2 mg/dl to 0.2 ± 0.2 mg/dl. CONCLUSIONS: Correcting continuous BG measurements for blood dilution significantly increases BG measurement and clamp quality.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Sistemas de Infusão de Insulina/normas , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
J Diabetes Sci Technol ; 13(2): 261-267, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30241444

RESUMO

In the last 10 years tremendous progress has been made in the development of artificial pancreas (AP) systems for people with type 1 diabetes (T1D). The pan-European consortium CLOSE (Automated Glu cose Contro l at H ome for People with Chronic Disea se) is aiming to develop integrated AP solutions (APplus) tailored to the needs of people with type 2 diabetes (T2D). APplus comprises a product and service package complementing the AP system by obligatory training as well as home visits and telemedical consultations on demand. Outcome predictors and performance indicators shall help to identify people who could benefit most from AP usage and facilitate the measurement of AP impact in diabetes care. In a first step CLOSE will establish a scalable APplus model case working at the interface between patients, homecare service providers, and payers in France. CLOSE will then scale up APplus by pursuing geographic distribution, targeting additional audiences, and enhancing AP functionalities and interconnectedness. By being part of the European Institute of Innovation and Technology (EIT) Health public-private partnership, CLOSE is committed to the EIT "knowledge triangle" pursuing the integrated advancement of technology, education, and business creation. Putting stakeholders, education, and impact into the center of APplus advancement is considered key for achieving wide AP use in T2D care.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Sistemas de Infusão de Insulina , Pâncreas Artificial , Animais , Biomarcadores , Glicemia/metabolismo , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/diagnóstico , Desenho de Equipamento , Europa (Continente) , Humanos , Sistemas de Infusão de Insulina/efeitos adversos , Pâncreas Artificial/efeitos adversos , Projetos de Pesquisa , Participação dos Interessados , Resultado do Tratamento
7.
Diabetes Technol Ther ; 19(2): 124-130, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28005401

RESUMO

BACKGROUND: In glucose clamp experiments, blood glucose concentrations (BGs) are kept as close as possible to a predefined target level using variable glucose infusion rates (GIRs). In automated clamps, GIRs are calculated by algorithms implemented in the device (e.g., the Biostator). Low BG- and GIR-variability is needed for high clamp quality. We therefore tried to reduce oscillations in both BG and GIR with an improved algorithm implemented in ClampArt, a modern clamp device. SUBJECTS AND METHODS: The Biostator algorithm was first improved by numerical simulations of glucose clamps (in silico). With the results of the simulations, we started in vitro experiments using the ClampArt device and a container with water and glucose as "test subject." After a small pilot in vivo study, a larger clinical study was performed to compare the original with the optimized algorithm. RESULTS: With the improved algorithm, in silico, in vitro, and in vivo experiments showed reduced oscillations in both BG and GIR. In the clinical study, the coefficient of variation (CV) of BG values was lowered from 6.0% (4.6%-7.8%) [median (interquartile range)] to 4.2% (3.6%-5.0%), P < 0.0001 and the CV of GIR from 60.7% (49.6%-82.0%) to 43.5% (32.8%-57.2%), P < 0.0001. Other clamp quality parameters did not change substantially, median deviation from target slightly increased from 0.6% (0.2%-1.0%) to 1.1% (0.7%-1.5%), P = 0.0005, whereas utility did not change [97.0% (93.4%-100.0%) vs. 97.0% (94.0%-98.8%), P = 0.57]. CONCLUSIONS: With the improved algorithm, all experiments confirmed a reduction in BG- and GIR-oscillations without a major impact on other glucose clamp parameters. The optimized algorithm has been implemented in ClampArt for all future glucose clamp studies.


Assuntos
Algoritmos , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Técnica Clamp de Glucose , Adulto , Idoso , Simulação por Computador , Feminino , Humanos , Insulina/sangue , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
Diabetes Technol Ther ; 19(7): 433-437, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28463010

RESUMO

OBJECTIVES: We evaluated patterns of meal intake, insulin bolus delivery, and fingerstick glucose measurements during hybrid closed-loop and sensor-augmented pump (SAP) therapy, including associations with glucose control. METHODS: Data were retrospectively analyzed from pump-treated adults with type 1 diabetes who underwent, in random order, 12 weeks free-living closed-loop (n = 32) and 12 weeks SAP (n = 33) periods. We quantified daily patterns of main meals, snacks, prandial insulin boluses, correction boluses, and fingerstick glucose measurements by analyzing data recorded on the study glucometer and on study insulin pump. RESULTS: We analyzed 1942 closed-loop days and 2530 SAP days. The total number of insulin boluses was reduced during closed-loop versus SAP periods by mean 1.0 per day (95% confidence interval 0.6-1.4, P < 0.001) mainly because of a reduced number of correction boluses by mean 0.7 per day (0.4-1.0, P < 0.001). Other behavioral patterns were unchanged. The carbohydrate content of snacks but not the number of snacks was positively correlated with (1) glycemic variability as measured by standard deviation of sensor glucose (closed-loop P < 0.05; SAP P < 0.01), (2) mean sensor glucose (P < 0.05), and (3) postintervention HbA1c (P < 0.05). Behavioral patterns explained 47% of between-subject variance in glucose variability during SAP period and 30%-33% of variance of means sensor glucose and postintervention HbA1c. CONCLUSION: Fewer correction boluses are delivered during closed-loop period. The size of snacks appears to worsen glucose control possibly because of carbohydrate-rich content of snacks. Modifiable behavioral patterns may be important determinants of glucose control.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Comportamento Alimentar/fisiologia , Hipoglicemiantes/uso terapêutico , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Adulto , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Refeições , Pessoa de Meia-Idade
9.
J Diabetes Sci Technol ; 11(6): 1080-1088, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28367636

RESUMO

OBJECTIVE: The objective was to explore psychosocial experiences of closed loop technology for adults, children, and adolescents with type 1 diabetes and their parents taking part in two multicenter, free-living, randomized crossover home studies. METHODS: Participants using insulin pump therapy were randomized to either 12 weeks of automated closed-loop glucose control, then 12 weeks of sensor augmented insulin pump therapy (open loop), or vice versa. Closed loop was used for 24 hours by adults and overnight only by children and adolescents. Participants completed the Diabetes Technology Questionnaire (DTQ) periodically and shared their views in semistructured interviews. This analysis characterizes the impact of the technology, positive and negative aspects of living with the device, alongside participants' expectations, hopes, and anxieties. RESULTS: Participants were 32 adults, age 38.6 ± 9.6 years, 55% male, and 26 children, mean age 12 years (range 6-18 years), 54% male. DTQ results indicated moderately favorable impact of, and satisfaction with, both open and closed loop interventions, but little evidence of a comparative advantage of either. Key positive themes included perceived improved blood glucose control, improved general well-being, particularly on waking, improved sleep, reduced burden of diabetes, and visibility of data. Key negative themes included having to carry around the equipment and dislike of the pump and second cannula (ie, sensor) inserted. CONCLUSIONS: Overall, participants reported a positive experience of the closed loop technology. Results are consistent with previous research with size of equipment continuing to be a problem. Progress is being made in the usability of the closed-loop system.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adaptação Psicológica , Adolescente , Adulto , Biomarcadores/sangue , Glicemia/metabolismo , Automonitorização da Glicemia , Criança , Efeitos Psicossociais da Doença , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/psicologia , Europa (Continente) , Feminino , Hemoglobinas Glicadas/metabolismo , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Entrevistas como Assunto , Masculino , Satisfação do Paciente , Qualidade de Vida , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
10.
J Diabetes Sci Technol ; 10(4): 950-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26888971

RESUMO

In the past years the development of an artificial pancreas (AP) has made great progress and many activities are ongoing in this area of research. The major step forward made in the last years was moving the evaluation of AP systems from highly controlled experimental conditions to daily life conditions at the home of patients with diabetes; this was also the aim of the European Union-funded AP@home project. Over a time period of 5 years a series of clinical studies were performed that culminated in 2 "final studies" during which an AP system was used by patients in their home environment for 2 or 3 months without supervision by a physician, living their normal lives. Two different versions of the AP system developed within this project were evaluated. A significant improvement in glycated hemoglobin was observed during closed-loop conditions despite the fact that during the control period the patients used the best currently available therapeutic option. In addition, a "single-port AP system" was developed within the project that combines continuous glucose monitoring and insulin infusion at a single tissue site. By using such a combined device the patients not only have to carry one less device around, the number of access points through the skin is also reduced from 2 to 1. In summary, close cooperation of 12 European partners, both academic centers and industry, enabled the development and evaluation of AP systems under daily life conditions. The next step is to develop these into products in cooperation with commercial partners.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Pâncreas Artificial , Humanos
11.
Diabetes Care ; 39(5): 830-2, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26965717

RESUMO

OBJECTIVE: To quantify variability of insulin requirements during closed-loop insulin delivery. RESEARCH DESIGN AND METHODS: We retrospectively analyzed overnight, daytime, and total daily insulin amounts delivered during a multicenter closed-loop trial involving 32 adults with type 1 diabetes. Participants applied hybrid day-and-night closed-loop insulin delivery under free-living home conditions over 12 weeks. The coefficient of variation was adopted to measure variability of insulin requirements in individual subjects. RESULTS: Data were analyzed from 1,918 nights, 1,883 daytime periods and 1,564 total days characterized by closed-loop use over 85% of time. Variability of overnight insulin requirements (mean [SD] coefficient of variation 31% [4]) was nearly twice as high as variability of total daily requirements (17% [3], P < 0.001) and was also higher than variability of daytime insulin requirements (22% [4], P < 0.001). CONCLUSIONS: Overnight insulin requirements were significantly more variable than daytime and total daily amounts. This may explain why some people with type 1 diabetes report frustrating variability in morning glycemia.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
12.
J Diabetes Sci Technol ; 9(4): 792-800, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25852075

RESUMO

BACKGROUND: There are no widely accepted parameters to assess the quality of glucose clamps. Thus, we selected different parameters describing clamp quality. These parameters were then evaluated in glucose clamps carried out with ClampArt, a novel CE-marked, state-of-the-art fully automated glucose clamp device employing continuous blood glucose (BG) measurements and minute-by-minute adaptations of glucose infusion rate (GIR). METHODS: Thirty-nine glucose clamps were performed in 10 healthy and 29 subjects with type 1 diabetes (T1DM) (total duration 583 h). ClampArt-based BG measurements were compared with those obtained with a laboratory reference method. Clamp quality was assessed by 5 parameters: (1) difference (mg/dl) of all paired BG measurements of ClampArt versus reference method ("trueness"), (2) coefficient of variation (CV, %) of ClampArt's BG measurements at target clamp level ("precision"), (3) mean absolute relative difference (MARD, %) at target clamp level ("accuracy"), (4) difference (mg/dl) between ClampArt and target BG ("control deviation"), and (5) percentage operational time ("utility"). RESULTS: ClampArt-based BG measurements showed a trueness of 1.2 ± 2.5 mg/dl. CV and MARD at target BG were 5.5 ± 2.1% and 5.3 ± 2.3%, respectively. There were only small deviations from target level (1.2 ± 1.6 mg/dl). Operational time was as high as 95.4% ± 4.1% (means ± SD). CONCLUSIONS: The selected parameters seem to be adequate to characterize clamp quality. The novel, fully automated clamp device ClampArt achieves high clamp quality, which in future trials should be compared with other (automated and manual) clamp methods.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Técnica Clamp de Glucose , Monitorização Fisiológica/instrumentação , Adulto , Automação , Diabetes Mellitus Tipo 1/diagnóstico , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Qualidade da Assistência à Saúde , Reprodutibilidade dos Testes , Adulto Jovem
14.
Diabetes Technol Ther ; 17(11): 801-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26241693

RESUMO

OBJECTIVES: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a continuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator(®) II CGM (Abbott Diabetes Care, Alameda, CA) during three unsupervised, randomized, open-label, crossover home CL studies. MATERIALS AND METHODS: Paired CGM and capillary glucose values (10,597 pairs) were collected from 57 participants with type 1 diabetes (41 adults [mean±SD age, 39±12 years; mean±SD hemoglobin A1c, 7.9±0.8%] recruited at five centers and 16 adolescents [mean±SD age, 15.6±3.6 years; mean±SD hemoglobin A1c, 8.1±0.8%] recruited at two centers). Numerical accuracy was assessed by absolute relative difference (ARD) and International Organization for Standardization (ISO) 15197:2013 15/15% limits, and clinical accuracy was assessed by Clarke error grid analysis. RESULTS: Total duration of sensor use was 2,002 days (48,052 h). Overall sensor accuracy for the capillary glucose range (1.1-27.8 mmol/L) showed mean±SD and median (interquartile range) ARD of 14.2±15.5% and 10.0% (4.5%, 18.4%), respectively. Lowest mean ARD was observed in the hyperglycemic range (9.8±8.8%). Over 95% of pairs were in combined Clarke error grid Zones A and B (A, 80.1%, B, 16.2%). Overall, 70.0% of the sensor readings satisfied ISO criteria. Mean ARD was consistent (12.3%; 95% of the values fall within ±3.7%) and not different between participants (P=0.06) within the euglycemic and hyperglycemic range, when CL is actively modulating insulin delivery. CONCLUSIONS: Consistent accuracy of the CGM within the euglycemic-hyperglycemic range using the Freestyle Navigator II was observed and supports its use in home CL studies. Our results may contribute toward establishing normative CGM performance criteria for unsupervised home use of CL.


Assuntos
Automonitorização da Glicemia/normas , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Adolescente , Adulto , Automonitorização da Glicemia/instrumentação , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/diagnóstico , Hipoglicemia/tratamento farmacológico , Hipoglicemia/etiologia , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/normas , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Condições Sociais , Comunicação para Apreensão de Informação , Fatores de Tempo
15.
BMJ Open ; 4(9): e006075, 2014 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-25186158

RESUMO

INTRODUCTION: Despite therapeutic advances, many people with type 1 diabetes are still unable to achieve optimal glycaemic control, limited by the occurrence of hypoglycaemia. The objective of the present study is to determine the effectiveness of day and night home closed-loop over the medium term compared with sensor-augmented pump therapy in adults with type 1 diabetes and suboptimal glycaemic control. METHODS AND ANALYSIS: The study will adopt an open label, three-centre, multinational, randomised, two-period crossover study design comparing automated closed-loop glucose control with sensor augmented insulin pump therapy. The study will aim for 30 completed participants. Eligible participants will be adults (≥18 years) with type 1 diabetes treated with insulin pump therapy and suboptimal glycaemic control (glycated haemoglobin (HbA1c)≥7.5% (58 mmol/mmol) and ≤10% (86 mmol/mmol)). Following a 4-week optimisation period, participants will undergo a 3-month use of automated closed-loop insulin delivery and sensor-augmented pump therapy, with a 4-6 week washout period in between. The order of the interventions will be random. All analysis will be conducted on an intention to treat basis. The primary outcome is the time spent in the target glucose range from 3.9 to 10.0 mmol/L based on continuous glucose monitoring levels during the 3 months free living phase. Secondary outcomes include HbA1c changes; mean glucose and time spent above and below target glucose levels. Further, participants will be invited at baseline, midpoint and study end to participate in semistructured interviews and complete questionnaires to explore usability and acceptance of the technology, impact on quality of life and fear of hypoglycaemia. ETHICS AND DISSEMINATION: Ethical approval has been obtained at all sites. Before screening, all participants will be provided with oral and written information about the trial. The study will be disseminated by peer-review publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT01961622 (ClinicalTrials.gov).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Adulto , Estudos Cross-Over , Feminino , Hemoglobinas Glicadas/análise , Humanos , Masculino , Monitorização Fisiológica , Fatores de Tempo , Resultado do Tratamento
16.
Diabetes Care ; 37(7): 1931-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24963110

RESUMO

OBJECTIVE: To evaluate the feasibility of day and night closed-loop insulin delivery in adults with type 1 diabetes under free-living conditions. RESEARCH DESIGN AND METHODS: Seventeen adults with type 1 diabetes on insulin pump therapy (means ± SD age 34 ± 9 years, HbA1c 7.6 ± 0.8%, and duration of diabetes 19 ± 9 years) participated in an open-label multinational three-center crossover study. In a random order, participants underwent two 8-day periods (first day at the clinical research facility followed by 7 days at home) of sensor-augmented insulin pump therapy (SAP) or automated closed-loop insulin delivery. The primary end point was the time when sensor glucose was in target range between 3.9 and 10.0 mmol/L during the 7-day home phase. RESULTS: During the home phase, the percentage of time when glucose was in target range was significantly higher during closed-loop compared with SAP (median 75% [interquartile range 61-79] vs. 62% [53-70], P = 0.005). Mean glucose (8.1 vs. 8.8 mmol/L, P = 0.027) and time spent above target (P = 0.013) were lower during closed loop, while time spent below target was comparable (P = 0.339). Increased time in target was observed during both daytime (P = 0.017) and nighttime (P = 0.013). CONCLUSIONS: Compared with SAP, 1 week of closed-loop insulin delivery at home reduces mean glucose and increases time in target without increasing the risk of hypoglycemia in adults with relatively well-controlled type 1 diabetes.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Adulto , Glicemia/efeitos dos fármacos , Estudos Cross-Over , Estudos de Viabilidade , Feminino , Humanos , Hipoglicemia/epidemiologia , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino
17.
Diabetes Care ; 36(4): 793-800, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23172973

RESUMO

OBJECTIVE: Reliability of continuous glucose monitoring (CGM) sensors is key in several applications. In this work we demonstrate that real-time algorithms can render CGM sensors smarter by reducing their uncertainty and inaccuracy and improving their ability to alert for hypo- and hyperglycemic events. RESEARCH DESIGN AND METHODS: The smart CGM (sCGM) sensor concept consists of a commercial CGM sensor whose output enters three software modules, able to work in real time, for denoising, enhancement, and prediction. These three software modules were recently presented in the CGM literature, and here we apply them to the Dexcom SEVEN Plus continuous glucose monitor. We assessed the performance of the sCGM on data collected in two trials, each containing 12 patients with type 1 diabetes. RESULTS: The denoising module improves the smoothness of the CGM time series by an average of ∼57%, the enhancement module reduces the mean absolute relative difference from 15.1 to 10.3%, increases by 12.6% the pairs of values falling in the A-zone of the Clarke error grid, and finally, the prediction module forecasts hypo- and hyperglycemic events an average of 14 min ahead of time. CONCLUSIONS: We have introduced and implemented the sCGM sensor concept. Analysis of data from 24 patients demonstrates that incorporation of suitable real-time signal processing algorithms for denoising, enhancement, and prediction can significantly improve the performance of CGM applications. This can be of great clinical impact for hypo- and hyperglycemic alert generation as well in artificial pancreas devices.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/metabolismo , Monitorização Ambulatorial/instrumentação , Algoritmos , Feminino , Humanos , Masculino , Software
18.
Diabetes Technol Ther ; 15(8): 722-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23650900

RESUMO

OBJECTIVE: This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. RESEARCH DESIGN AND METHODS: We studied the Animas® (West Chester, PA) Vibe™ with Dexcom® (San Diego, CA) G4™ version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle® Navigator I (NAV), and the Medtronic (Northridge, CA) Paradigm® with Enlite™ sensor (ENL) in 20 patients with type 1 diabetes mellitus. All systems were investigated both in a clinical research center (CRC) and at home. In the CRC, patients received a meal with a delayed and increased insulin dose to induce a postprandial glucose peak and nadir. Hereafter, randomization determined which two of the three systems would be worn at home until the end of functioning, attempting use beyond manufacturer-specified lifetime. Patients performed at least five reference finger sticks per day. An analysis of variance was performed on all data points ≥15 min apart. RESULTS: Overall average mean absolute relative difference (MARD) (SD) measured at the CRC was 16.5% (14.3%) for NAV and 16.4% (15.6%) for ENL, outperforming G4A at 20.5% (18.2%) (P<0.001). Overall MARD when assessed at home was 14.5% (16.7%) for NAV and 16.5 (18.8%) for G4A, outperforming ENL at 18.9% (23.6%) (P=0.006). Median time until end of functioning was similar: 10.0 (1.0) days for G4A, 8.0 (3.5) days for NAV, and 8.0 (1.5) days for ENL (P=0.119). CONCLUSIONS: In the CRC, G4A was less accurate than NAV and ENL sensors, which seemed comparable. However, at home, ENL was less accurate than NAV and G4A. Moreover, CGM systems often show sufficient accuracy to be used beyond manufacturer-specified lifetime.


Assuntos
Diabetes Mellitus Tipo 1/metabolismo , Líquido Extracelular/metabolismo , Glucose/metabolismo , Hiperglicemia/diagnóstico , Hipoglicemia/diagnóstico , Monitorização Ambulatorial/instrumentação , Tela Subcutânea/metabolismo , Abdome , Atividades Cotidianas , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Europa (Continente) , Líquido Extracelular/efeitos dos fármacos , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Insulina/uso terapêutico , Estimativa de Kaplan-Meier , Teste de Materiais , Reprodutibilidade dos Testes , Tela Subcutânea/efeitos dos fármacos
19.
Diabetes Technol Ther ; 15(7): 575-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23650901

RESUMO

BACKGROUND AND AIMS: The aim of this study was to compare blood glucose and plasma insulin profiles after bolus insulin infusion by a patch pump (PP) versus a conventional pump (CP), directly after placement and after Day 3 of use. PATIENTS AND METHODS: Twenty patients with type 1 diabetes came in for two blocks of visits: one block of two visits while wearing the OmniPod® (Insulet Corp., Bedford, MA) insulin pump (PP) and one block of two visits while wearing the Medtronic Diabetes (Northridge, CA) Paradigm® pump (CP). Patients administered an identical mealtime insulin bolus of at least 6 IU. RESULTS: For PP, maximum glucose levels were 28.7% lower on Day 3 (P=0.020), when maximum insulin levels were 30.3% higher (P=0.002). For CP, maximum glucose levels were 26.5% lower on Day 3 (P=0.015), when maximum insulin levels were 46.4% higher (P=0.003). Glucose levels (mean [interquartile range]) were significantly lower on Day 3 for PP (168.2 [145.8] mg/dL vs. 139.4 [77.8] mg/dL; P=0.013), but not significantly so for CP (159.0 [66.1] mg/dL vs. 139.5 [57.9] mg/dL; P=0.084). Mean insulin levels were significantly higher on Day 3 for CP (195 [120] pmol/L vs. 230 [90] pmol/L; P=0.01), but not significantly so for PP (178 [106] pmol/L vs. 194 [120] pmol/L; P=0.099). There were no significant differences between the two catheter lengths. CONCLUSIONS: Postprandial glycemic excursions were lower on Day 3 of catheter wear time, but there were no differences between PPs and CPs. These findings support the proposal that catheter wear time plays an important role in insulin absorption.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Liberação de Medicamentos/instrumentação , Hiperglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Insulina Lispro/administração & dosagem , Administração Cutânea , Glicemia/análise , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Humanos , Hipoglicemiantes/sangue , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/uso terapêutico , Infusões Subcutâneas , Sistemas de Infusão de Insulina , Insulina Lispro/sangue , Insulina Lispro/farmacocinética , Insulina Lispro/uso terapêutico , Teste de Materiais , Período Pós-Prandial , Absorção Cutânea , Adesivo Transdérmico
20.
Diabetes Care ; 36(12): 3882-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24170747

RESUMO

OBJECTIVE: To compare two validated closed-loop (CL) algorithms versus patient self-control with CSII in terms of glycemic control. RESEARCH DESIGN AND METHODS: This study was a multicenter, randomized, three-way crossover, open-label trial in 48 patients with type 1 diabetes mellitus for at least 6 months, treated with continuous subcutaneous insulin infusion. Blood glucose was controlled for 23 h by the algorithm of the Universities of Pavia and Padova with a Safety Supervision Module developed at the Universities of Virginia and California at Santa Barbara (international artificial pancreas [iAP]), by the algorithm of University of Cambridge (CAM), or by patients themselves in open loop (OL) during three hospital admissions including meals and exercise. The main analysis was on an intention-to-treat basis. Main outcome measures included time spent in target (glucose levels between 3.9 and 8.0 mmol/L or between 3.9 and 10.0 mmol/L after meals). RESULTS: Time spent in the target range was similar in CL and OL: 62.6% for OL, 59.2% for iAP, and 58.3% for CAM. While mean glucose level was significantly lower in OL (7.19, 8.15, and 8.26 mmol/L, respectively) (overall P = 0.001), percentage of time spent in hypoglycemia (<3.9 mmol/L) was almost threefold reduced during CL (6.4%, 2.1%, and 2.0%) (overall P = 0.001) with less time ≤2.8 mmol/L (overall P = 0.038). There were no significant differences in outcomes between algorithms. CONCLUSIONS: Both CAM and iAP algorithms provide safe glycemic control.


Assuntos
Algoritmos , Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Autocuidado/métodos , Administração Cutânea , Adulto , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Hipoglicemiantes/administração & dosagem , Bombas de Infusão , Masculino , Resultado do Tratamento