Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Diabetologia ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780786

RESUMO

AIMS/HYPOTHESIS: Our study aims to uncover glycaemic phenotype heterogeneity in type 1 diabetes. METHODS: In the Study of the French-speaking Society of Type 1 Diabetes (SFDT1), we characterised glycaemic heterogeneity thanks to a set of complementary metrics: HbA1c, time in range (TIR), time below range (TBR), CV, Gold score and glycaemia risk index (GRI). Applying the Discriminative Dimensionality Reduction with Trees (DDRTree) algorithm, we created a phenotypic tree, i.e. a 2D visual mapping. We also carried out a clustering analysis for comparison. RESULTS: We included 618 participants with type 1 diabetes (52.9% men, mean age 40.6 years [SD 14.1]). Our phenotypic tree identified seven glycaemic phenotypes. The 2D phenotypic tree comprised a main branch in the proximal region and glycaemic phenotypes in the distal areas. Dimension 1, the horizontal dimension, was positively associated with GRI (coefficient [95% CI]) (0.54 [0.52, 0.57]), HbA1c (0.39 [0.35, 0.42]), CV (0.24 [0.19, 0.28]) and TBR (0.11 [0.06, 0.15]), and negatively with TIR (-0.52 [-0.54, -0.49]). The vertical dimension was positively associated with TBR (0.41 [0.38, 0.44]), CV (0.40 [0.37, 0.43]), TIR (0.16 [0.12, 0.20]), Gold score (0.10 [0.06, 0.15]) and GRI (0.06 [0.02, 0.11]), and negatively with HbA1c (-0.21 [-0.25, -0.17]). Notably, socioeconomic factors, cardiovascular risk indicators, retinopathy and treatment strategy were significant determinants of glycaemic phenotype diversity. The phenotypic tree enabled more granularity than traditional clustering in revealing clinically relevant subgroups of people with type 1 diabetes. CONCLUSIONS/INTERPRETATION: Our study advances the current understanding of the complex glycaemic profile in people with type 1 diabetes and suggests that strategies based on isolated glycaemic metrics might not capture the complexity of the glycaemic phenotypes in real life. Relying on these phenotypes could improve patient stratification in type 1 diabetes care and personalise disease management.

2.
J Sleep Res ; 32(3): e13799, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36495012

RESUMO

The aim of this study was to better characterise whether sleep habits, eating schedule and physical activity in real-life are associated with glycaemic control in patients with type 2 diabetes. A total of 28 patients (aged 60 years [58; 66], 54% female) with type 2 diabetes treated with basal-bolus insulin therapy administered by insulin pumps were analysed. Glycaemic data measured by Flash Glucose Monitor System, physical activity and sleep data measured by accelerometer, and meal schedules were simultaneously collated with insulin pump administration data, for 7 days in real-life. Their respective impact on the time spent in target, in hypoglycaemia, in hyperglycaemia and on glycaemic variability was evaluated. Multiple regressions showed that the total daily dose of meal boluses of insulin was inversely associated with the coefficient of variation (CV; coefficient ß = -0.073; 95% confidence interval: -0.130, -0.015; p = 0.016), as well as sleep duration. The higher the sleep duration, the lower the glycaemic variability (coefficient ß = -0.012; 95% confidence interval: -0.023, -0.002; p = 0.027). The mean 7 days physical activity of the subjects was very low and was not associated with glycaemic control on the 7 days mean values. However, days with at least 1 hr spent in physical activity higher than 1.5 METs were associated with less glycaemic variability that same day. This real-life observation highlights the importance of sufficient sleep duration and regular physical activity to lessen the glycaemic variability of patients with type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Humanos , Feminino , Masculino , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Hipoglicemia/tratamento farmacológico , Glicemia , Sono
3.
Diabetes Obes Metab ; 25(6): 1607-1613, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36751978

RESUMO

AIM: The Diabeloop Generation 1 (DBLG1) system is an interoperable hybrid closed-loop solution that was commercialized in Germany in March 2021. We report the longitudinal glycaemic outcomes among the first 3706 users in a real-world setting. METHODS: We performed a retrospective data collection of all consenting adult patients with type 1 diabetes who were equipped in Germany with the DBLG1 system before 30 April 2022, and with a minimum 14 days of closed-loop usage. RESULTS: In total, 3706 users (41% women, age 45.1 ± 14.5 years) met the inclusion criteria, reaching a mean follow-up of 131.0 ± 85.1 days, an overall 485 600 days of continuous glucose monitoring data, and a median time spent in closed-loop of 95.0% (IQR 89.1-97.4). The median percentage time in range (70-180 mg/dl) was 72.1% (IQR 65.0-78.9); the time below 70 mg/dl was 0.9% (0.5-1.7), the time below 54 mg/dl was 0.1% (0.1-0.3), and the median Glucose Management Index was 7.0% (6.8-7.3). Exploratory analysis of a subset of 2460 patients in whom baseline glycated haemoglobin (HbA1c) was available [7.4% (IQR 6.9-8.0)] showed that the achieved mean time in range was influenced by baseline HbA1c, ranging from 65.8 ± 9.9% (A1c ≥8.5%) to 81.3 ± 6.8% (A1c <6.5%). CONCLUSION: This large real-world analysis confirms the relevance of the DBLG1 automated insulin delivery solution for the achievement of standards of care in adult patients with type 1 diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Glicemia , Automonitorização da Glicemia , Estudos Retrospectivos , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Glucose/uso terapêutico , Alemanha/epidemiologia
4.
Diabetes Obes Metab ; 25(6): 1624-1631, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36792920

RESUMO

AIM: To investigate sleep apnoea prevalence, factors influencing severity, and associations between sleep apnoea severity and micro-/macrovascular complications in a large population of patients with type 1 diabetes. MATERIALS AND METHODS: This French multicentre prospective cohort study was conducted between July 2016 and June 2020. Adults with type 1 diabetes using an insulin pump were eligible. Home care provider nurses collected demographic and clinical data and set up oximetry to determine the oxygen desaturation index (ODI). No, mild-moderate and severe sleep apnoea were defined as ODI <15 events/h, 15 to <30 events/h and ≥30 events/h, respectively. Univariate and multivariate analyses were performed to identify factors associated with sleep apnoea, and associations between sleep apnoea severity and micro-/macrovascular complications were determined using logistic regression. RESULTS: Of 769 participants, 12.4% and 3.4% had mild-to-moderate or severe sleep apnoea, respectively. Factors significantly associated with sleep apnoea on multivariate analysis were age, sex, body mass index (BMI) and hypertension. After adjustment for age, sex and BMI, presence of severe sleep apnoea was significantly associated with macrovascular complications (odds ratio vs. no sleep apnoea: 3.96 [95% confidence interval 1.43-11.11]; P < 0.01), while mild-to-moderate sleep apnoea was significantly associated with presence of diabetic retinopathy (odds ratio 2.09 [95% confidence interval 1.10-3.74]; P < 0.01). CONCLUSION: Sleep apnoea is a significant comorbidity in patients with type 1 diabetes, especially with respect to diabetic complications. This highlights the need for sleep apnoea screening and management in these individuals.


Assuntos
Diabetes Mellitus Tipo 1 , Apneia Obstrutiva do Sono , Adulto , Humanos , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/epidemiologia , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Fatores de Risco , Prevalência , Comorbidade
5.
Transpl Int ; 36: 11512, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37885808

RESUMO

Islet transplantation improves metabolic control in patients with unstable type 1 diabetes. Clinical outcomes have been improving over the last decade, and the widely used beta-score allows the evaluation of transplantation results. However, predictive pre-transplantation criteria of islet quality for clinical outcomes are lacking. In this proof-of-concept study, we examined whether characterization of the electrical activity of donor islets could provide a criterion. Aliquots of 8 human donor islets from the STABILOT study, sampled from islet preparations before transplantation, were characterized for purity and split for glucose-induced insulin secretion and electrical activity using multi-electrode-arrays. The latter tests glucose concentration dependencies, biphasic activity, hormones, and drug effects (adrenalin, GLP-1, glibenclamide) and provides a ranking of CHIP-scores from 1 to 6 (best) based on electrical islet activity. The analysis was performed online in real time using a dedicated board or offline. Grouping of beta-scores and CHIP-scores with high, intermediate, and low values was observed. Further analysis indicated correlation between CHIP-score and beta-score, although significance was not attained (R = 0.51, p = 0.1). This novel approach is easily implantable in islet isolation units and might provide means for the prediction of clinical outcomes. We acknowledge the small cohort size as the limitation of this pilot study.


Assuntos
Diabetes Mellitus Tipo 1 , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas , Humanos , Insulina/metabolismo , Glicemia/análise , Projetos Piloto , Transplante das Ilhotas Pancreáticas/métodos , Diabetes Mellitus Tipo 1/cirurgia , Glucose/metabolismo , Glucose/farmacologia
6.
Mikrochim Acta ; 190(5): 177, 2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-37022500

RESUMO

According to the latest statistics, more than 537 million people around the world struggle with diabetes and its adverse consequences. As well as acute risks of hypo- or hyper- glycemia, long-term vascular complications may occur, including coronary heart disease or stroke, as well as diabetic nephropathy leading to end-stage disease, neuropathy or retinopathy. Therefore, there is an urgent need to improve diabetes management to reduce the risk of complications but also to improve patient's quality life. The impact of continuous glucose monitoring (CGM) is well recognized, in this regard. The current review aims at introducing the basic principles of glucose sensing, including electrochemical and optical detection, summarizing CGM technology, its requirements, advantages, and disadvantages. The role of CGM systems in the clinical diagnostics/personal testing, difficulties in their utilization, and recommendations are also discussed. In the end, challenges and prospects in future CGM systems are discussed and non-invasive, wearable glucose biosensors are introduced. Though the scope of this review is CGMs and provides information about medical issues and analytical principles, consideration of broader use will be critical in future if the right systems are to be selected for effective diabetes management.


Assuntos
Glicemia , Diabetes Mellitus , Humanos , Automonitorização da Glicemia , Diabetes Mellitus/diagnóstico , Glucose
7.
Clin Gastroenterol Hepatol ; 20(8): 1857-1866.e1, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33189854

RESUMO

BACKGROUND & AIMS: Medico-economic data of patients suffering from chronic nausea and vomiting are lacking. In these patients, gastric electrical stimulation (GES) is an effective, but costly treatment. The aim of this study was to assess the efficacy, safety and medico-economic impact of Enterra therapy in patients with chronic medically refractory nausea and vomiting. METHODS: Data were collected prospectively from patients with medically refractory nausea and/or vomiting, implanted with an Enterra device and followed for two years. Gastrointestinal quality of life index (GIQLI) score, vomiting frequency, nutritional status and safety were evaluated. Direct and indirect expenditure data were prospectively collected in diaries. RESULTS: Complete clinical data were available for142 patients (60 diabetic, 82 non-diabetic) and medico-economic data were available for 96 patients (36 diabetic, 60 non-diabetic), 24 months after implantation. GIQLI score increased by 12.1 ± 25.0 points (p < .001), with a more significant improvement in non-diabetic than in diabetic patients (+15.8 ± 25.0 points, p < .001 versus 7.3 ± 24.5 points, p = .027, respectively). The proportion of patients vomiting less than once per month increased by 25.5% (p < .001). Hospitalisations, time off work and transport were the main sources of costs. Enterra therapy decreased mean overall healthcare costs from 8873 US$ to 5525 US$ /patient/year (p = .001), representing a saving of 3348 US$ per patient and per year. Savings were greater for diabetic patients (4096 US$ /patient/year) than for non-diabetic patients (2900 US$ /patient/year). CONCLUSIONS: Enterra therapy is an effective, safe and cost-effective option for patients with refractory nausea and vomiting. CLINICALTRIALS: gov Identifier: NCT00903799.


Assuntos
Terapia por Estimulação Elétrica , Gastroparesia , Estimulação Elétrica , Terapia por Estimulação Elétrica/efeitos adversos , Estresse Financeiro , Esvaziamento Gástrico , Humanos , Náusea/etiologia , Qualidade de Vida , Resultado do Tratamento , Vômito/etiologia , Vômito/terapia
8.
Diabetologia ; 64(4): 778-794, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33599800

RESUMO

AIMS/HYPOTHESIS: This is an update of the results from the previous report of the CORONADO (Coronavirus SARS-CoV-2 and Diabetes Outcomes) study, which aims to describe the outcomes and prognostic factors in patients with diabetes hospitalised for coronavirus disease-2019 (COVID-19). METHODS: The CORONADO initiative is a French nationwide multicentre study of patients with diabetes hospitalised for COVID-19 with a 28-day follow-up. The patients were screened after hospital admission from 10 March to 10 April 2020. We mainly focused on hospital discharge and death within 28 days. RESULTS: We included 2796 participants: 63.7% men, mean age 69.7 ± 13.2 years, median BMI (25th-75th percentile) 28.4 (25.0-32.4) kg/m2. Microvascular and macrovascular diabetic complications were found in 44.2% and 38.6% of participants, respectively. Within 28 days, 1404 (50.2%; 95% CI 48.3%, 52.1%) were discharged from hospital with a median duration of hospital stay of 9 (5-14) days, while 577 participants died (20.6%; 95% CI 19.2%, 22.2%). In multivariable models, younger age, routine metformin therapy and longer symptom duration on admission were positively associated with discharge. History of microvascular complications, anticoagulant routine therapy, dyspnoea on admission, and higher aspartate aminotransferase, white cell count and C-reactive protein levels were associated with a reduced chance of discharge. Factors associated with death within 28 days mirrored those associated with discharge, and also included routine treatment by insulin and statin as deleterious factors. CONCLUSIONS/INTERPRETATION: In patients with diabetes hospitalised for COVID-19, we established prognostic factors for hospital discharge and death that could help clinicians in this pandemic period. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT04324736.


Assuntos
COVID-19/diagnóstico , COVID-19/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Alta do Paciente , Idoso , Idoso de 80 Anos ou mais , COVID-19/complicações , COVID-19/terapia , Complicações do Diabetes/diagnóstico , Complicações do Diabetes/mortalidade , Complicações do Diabetes/terapia , Diabetes Mellitus/terapia , Feminino , Seguimentos , França/epidemiologia , Mortalidade Hospitalar , Hospitalização/estatística & dados numéricos , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Alta do Paciente/estatística & dados numéricos , Prognóstico , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2/fisiologia
9.
Am J Transplant ; 21(11): 3725-3733, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33961335

RESUMO

To describe the 10-year outcomes of islet transplantation within the Swiss-French GRAGIL Network, in patients with type 1 diabetes experiencing high glucose variability associated with severe hypoglycemia and/or with functional kidney graft. We conducted a retrospective analysis of all subjects transplanted in the GRAGIL-1c and GARGIL-2 islet transplantation trials and analyzed components of metabolic control, graft function and safety outcomes over the 10-year period of follow-up. Forty-four patients were included between September 2003 and April 2010. Thirty-one patients completed a 10-year follow-up. Ten years after islet transplantation, median HbA1c was 7.2% (6.2-8.0) (55 mmol/mol [44-64]) versus 8.0% (7.1-9.1) (64 mmol/mol [54-76]) before transplantation (p < .001). Seventeen of 23 (73.9%) recipients were free of severe hypoglycemia, 1/21 patients (4.8%) was insulin-independent and median C-peptide was 0.6 ng/ml (0.2-1.2). Insulin requirements (UI/kg/day) were 0.3 (0.1-0.5) versus 0.5 (0.4-0.6) before transplantation (p < .001). Median (IQR) ß-score was 1 (0-4) (p < .05 when comparing with pre-transplantation values) and 51.9% recipients had a functional islet graft at 10 years. With a 10-year follow-up in a multicentric network, islet transplantation provided sustained improvement of glycemic control and was efficient to prevent severe hypoglycemia in almost 75% of the recipients.


Assuntos
Diabetes Mellitus Tipo 1 , Transplante das Ilhotas Pancreáticas , Glicemia , Diabetes Mellitus Tipo 1/cirurgia , Humanos , Estudos Retrospectivos , Suíça , Resultado do Tratamento
10.
Gastroenterology ; 158(3): 506-514.e2, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31647902

RESUMO

BACKGROUND & AIMS: There have been conflicting results from trials of gastric electrical stimulation (GES) for treatment of refractory vomiting, associated or not with gastroparesis. We performed a large, multicenter, randomized, double-blind trial with crossover to study the efficacy of GES in patients with refractory vomiting, with or without gastroparesis. METHODS: For 4 months, we assessed symptoms in 172 patients (66% women; mean age ± standard deviation, 45 ± 12 years; 133 with gastroparesis) with chronic (>12 months) of refractory vomiting (idiopathic, associated with a type 1 or 2 diabetes, or postsurgical). A GES device was implanted and left unactivated until patients were randomly assigned, in a double-blind manner, to groups that received 4 months of stimulation parameters (14 Hz, 5 mA, pulses of 330 µs) or no stimulation (control); 149 patients then crossed over to the other group for 4 months. Patients were examined at the end of each 4-month period (at 5 and 9 months after implantation). Primary endpoints were vomiting score, ranging from 0 (daily vomiting) to 4 (no vomiting), and the quality of life, assessed by the Gastrointestinal Quality of Life Index scoring system. Secondary endpoints were changes in other digestive symptoms, nutritional status, gastric emptying, and control of diabetes. RESULTS: During both phases of the crossover study, vomiting scores were higher in the group with the device on (median score, 2) than the control group (median score, 1; P < .001), in diabetic and nondiabetic patients. Vomiting scores increased significantly when the device was ON in patients with delayed (P < .01) or normal gastric emptying (P = .05). Gastric emptying was not accelerated during the ON period compared with the OFF period. Having the GES turned on was not associated with increased quality of life. CONCLUSIONS: In a randomized crossover study, we found that GES reduced the frequency of refractory vomiting in patients with and without diabetes, although it did not accelerate gastric emptying or increase of quality of life. Clinicaltrials.gov, Number: NCT00903799.


Assuntos
Terapia por Estimulação Elétrica/métodos , Gastroparesia/complicações , Vômito/terapia , Adulto , Estudos Cross-Over , Método Duplo-Cego , Terapia por Estimulação Elétrica/instrumentação , Eletrodos Implantados , Feminino , Esvaziamento Gástrico/fisiologia , Gastroparesia/fisiopatologia , Gastroparesia/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Vômito/diagnóstico , Vômito/etiologia
11.
Diabetes Obes Metab ; 23(1): 186-194, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001536

RESUMO

AIM: To compare the efficacy of the closed-loop Diabeloop for highly unstable diabetes (DBLHU) system with the open-loop predictive low glucose suspend (PLGS) system in patients with highly unstable type 1 diabetes (T1D) who experience acute metabolic events. METHODS: DBLHU-WP10 was an interventional, controlled, randomized, open-label study that comprised two cycles of N-of-1 trials (2-of-1 trials). Each trial consisted of two crossover 4-week periods of treatment with either DBLHU or PLGS in randomized order. The primary outcome was the percentage of time spent in the 70-180 mg/dL glucose range (time in range [TIR]). RESULTS: Five out of seven randomized patients completed the aggregated 2-of-1 trials. TIR was significantly higher with DBLHU (73.3% ± 1.7%) compared with PLGS (43.5% ± 1.7%; P < .0001). The percentage of time below 70 mg/dL was significantly lower with DBLHU (0.9% ± 0.4%) versus PLGS (3.7% ± 0.4%; P < .0001). DBLHU was also significantly superior to PLGS in reducing hyperglycaemic excursions and improving almost all other secondary outcomes, including glucose variability and satisfaction score. No adverse event could be related to the experimental treatment. CONCLUSIONS: DBLHU was superior to PLGS in improving the metabolic control of patients with highly unstable T1D who require an islet or pancreas transplant but who either have a contraindication or refuse to consent.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Transplante das Ilhotas Pancreáticas , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Diabetes Obes Metab ; 23(9): 2170-2176, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34009725

RESUMO

A post hoc analysis of the Diabeloop WP7 multicentre, randomized controlled trial was performed to investigate the efficacy of the Diabeloop Generation-1 (DBLG1) closed-loop system in controlling the hypoglycaemia induced by physical activity (PA) in real-life conditions. Glycaemic outcomes were compared between days with and without PA in 56 patients with type 1 diabetes (T1D) using DBLG1 for 12 weeks. After the patient announces a PA, DBLG1 reduces insulin delivery and, if necessary, calculates the amount of preventive carbohydrates (CHO). Daily time spent in the interstitial glucose range less than 70 mg/dL was not significantly different between days with and without PA (2.0% ± 1.5% vs. 2.2% ± 1.1%), regardless of the intensity or duration of the PA. Preventive CHO intake recommended by the system was significantly higher in days with PA (41.1 ± 35.5 vs. 21.8 ± 28.5 g/day; P < .0001), and insulin delivery was significantly lower (31.5 ± 10.5 vs. 34.0 ± 10.5 U/day; P < .0001). The time spent in hyperglycaemia and the glycaemic variation coefficient increased significantly on days with PA. In real-life conditions, the use of DBLG1 avoids PA-induced hypoglycaemia. Insulin adjustments and preventive CHO recommendation may explain this therapeutic benefit.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Dieta , Exercício Físico , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
13.
Am J Transplant ; 20(1): 40-51, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31319009

RESUMO

Markers of early pancreatic islet graft dysfunction and its causes are lacking. We monitored 19 type 1 diabetes islet-transplanted patients for up to 36 months following last islet injection. Patients were categorized as Partial (PS) or complete (S) Success, or Graft Failure (F), using the ß-score as an indicator of graft function. F was the subset reference of maximum worsened graft outcome. To identify the immune, pancreatic, and liver contribution to the graft dysfunction, the cell origin and concentration of circulating microvesicles (MVs) were assessed, including MVs from insulin-secreting ß-cells typified by polysialic acid of neural cell adhesion molecule (PSA-NCAM), and data were compared with values of the ß-score. Similar ranges of PSA-NCAM+ -MVs were found in healthy volunteers and S patients, indicating minimal cell damage. In PS, a 2-fold elevation in PSA-NCAM+ -MVs preceded each ß-score drop along with a concomitant rise in insulin needs, suggesting ß-cell damage or altered function. Significant elevation of liver asialoglycoprotein receptor (ASGPR)+ -MVs, endothelial CD105+ -MVs, neutrophil CD66b+ -MVs, monocyte CD 14+ -MVs, and T4 lymphocyte CD4+ -MVs occurred before each ß-score drop, CD8+ -MVs increased only in F, and B lymphocyte CD19+ -MVs remained undetectable. In conclusion, PSA-NCAM+ -MVs are noninvasive early markers of transplant dysfunction, while ASGPR+ -MVs signal host tissue remodeling. Leukocyte MVs could identify the cause of graft dysfunction.


Assuntos
Micropartículas Derivadas de Células/patologia , Diabetes Mellitus Tipo 1/terapia , Rejeição de Enxerto/diagnóstico , Células Secretoras de Insulina/patologia , Transplante das Ilhotas Pancreáticas/efeitos adversos , Leucócitos/patologia , Complicações Pós-Operatórias/diagnóstico , Adulto , Idoso , Feminino , Seguimentos , Rejeição de Enxerto/etiologia , Sobrevivência de Enxerto , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Prognóstico , Fatores de Risco
14.
Diabetes Obes Metab ; 22(3): 324-334, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31621186

RESUMO

AIMS: To compare closed-loop (CL) and open-loop (OL) systems for glycaemic control in patients with type 1 diabetes (T1D) exposed to real-life challenging situations (gastronomic dinners or sustained physical exercise). METHODS: Thirty-eight adult patients with T1D were included in a three-armed randomized pilot trial (Diabeloop WP6.2 trial) comparing glucose control using a CL system with use of an OL device during two crossover 72-hour periods in one of the three following situations: large (gastronomic) dinners; sustained and repeated bouts of physical exercise (with uncontrolled food intake); or control (rest conditions). Outcomes included time in spent in the glucose ranges of 4.4-7.8 mmol/L and 3.9-10.0 mmol/L, and time in hypo- and hyperglycaemia. RESULTS: Time spent overnight in the tight range of 4.4 to 7.8 mmol/L was longer with CL (mean values: 63.2% vs 40.9% with OL; P ≤ .0001). Time spent during the day in the range of 3.9 to 10.0 mmol/L was also longer with CL (79.4% vs 64.1% with OL; P ≤ .0001). Participants using the CL system spent less time during the day with hyperglycaemic excursions (glucose >10.0 mmol/L) compared to those using an OL system (17.9% vs 31.9%; P ≤ .0001), and the proportions of time spent during the day with hyperglycaemic excursions of those using the CL system in the gastronomic dinner and physical exercise subgroups were of similar magnitude to those in the control subgroup (18.1 ± 6.3%, 17.2 ± 8.1% and 18.4 ± 12.5%, respectively). Finally, times spent in hypoglycaemia were short and not significantly different among the groups. CONCLUSIONS: The Diabeloop CL system is superior to OL devices in reducing hyperglycaemic excursions in patients with T1D exposed to gastronomic dinners, or exposed to physical exercise followed by uncontrolled food and carbohydrate intake.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Exercício Físico , Controle Glicêmico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Refeições
16.
Diabetes Obes Metab ; 21(10): 2327-2332, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31173451

RESUMO

TeleDiab-2 was a 13-month randomized controlled trial evaluating the efficacy and safety of two telemonitoring systems to optimize basal insulin (BI) initiation in subjects with inadequately controlled type 2 diabetes (HbA1c, 7.5%-10%). A total of 191 participants (mean age 58.7 years, mean HbA1c 8.9%) were randomized into three groups: group 1(G1, standard care, n = 63), group 2 (G2, interactive voice response system, n = 64) and group 3 (G3, Diabeo-BI app software, n = 64). The two telemonitoring systems proposed daily adjustments of BI doses, in order to facilitate the achievement of fasting blood glucose (FBG) values targeted at ~100 mg/dL. At 4 months follow-up, HbA1c reduction was significantly higher in the telemonitoring groups (G2: -1.44% and G3: -1.48% vs. G1: -0.92%; P < 0.002). Moreover, target FBG was reached by twice as many patients in the telemonitoring groups as in the control group, and insulin doses were also titrated to higher levels. No severe hypoglycaemia was observed in the telemonitoring groups and mild hypoglycaemia frequency was similar in all groups. In conclusion, both telemonitoring systems improved glycaemic control to a similar extent, without increasing hypoglycaemic episodes.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina , Diabetes Mellitus Tipo 2/metabolismo , Humanos , Insulina/administração & dosagem , Insulina/uso terapêutico , Pessoa de Meia-Idade
17.
Transpl Int ; 31(8): 917-929, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29603452

RESUMO

The microbiological safety of islet preparations is paramount. Preservation medium contamination is frequent, and its impact on islet yield and function remains unclear. Microbiological samples collected during islet isolations from 2006 to 2016 were analyzed and correlated to isolation and allo- and autotransplantation outcomes. Microbial contamination of preservation medium was found in 64.4% of processed donor pancreases (291/452). We identified 464 microorganisms including Staphylococcus (253/464, 54.5%), Streptococcus (31/464, 6.7%), and Candida species (25/464, 5.4%). Microbial contamination was associated with longer warm and cold ischemia times and lower numbers of postpurification islet equivalents, purity, transplant rate, and stimulation index (all P < 0.05). Six percent of the preparations accepted for transplantation showed microbial contamination after isolation (12/200); 9 of 12 were Candida species. Six patients were transplanted with a sample with late microbial growth discovered after the infusion. Insulin independence rate was not affected. This risk of transplanting a contaminated islets preparation was reduced by half following the implementation of an additional sampling after 24 h of islet culture. Pancreas preservation fluid microbial contamination is associated with lower transplant rate and poorer in vitro function, but not with changes in graft survival. Culture medium testing 1 day after isolation reduces the risk of incidental transplantation with contaminated islets.


Assuntos
Contaminação de Medicamentos/estatística & dados numéricos , Transplante das Ilhotas Pancreáticas/estatística & dados numéricos , Soluções para Preservação de Órgãos , Adolescente , Adulto , Idoso , Criança , Estudos de Coortes , Feminino , Humanos , Ilhotas Pancreáticas/microbiologia , Masculino , Pessoa de Meia-Idade , Adulto Jovem
18.
J Autoimmun ; 79: 84-90, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28190705

RESUMO

BACKGROUND: Safety of HPV vaccines is still in question due to reports of autoimmune diseases (ADs) following HPV immunization. OBJECTIVES: To assess the risk of ADs associated with HPV vaccination of female adolescents/young adults in France. METHODS: Systematic prospective case-referent study conducted to assess the risks associated with real-life use of HPV vaccines. Cases were female 11-25 years old with incident ADs [central demyelination/multiple sclerosis (CD/MS), connective tissue disease (CTD), Guillain-Barré syndrome (GBS), type-1 diabetes (T1D), autoimmune thyroiditis (AT), and idiopathic thrombocytopenic purpura (ITP)]. Cases were consecutively and prospectively identified at specialized centers across France (2008-2014) and individually matched by age and place of residence to referents recruited in general practice. Risk was computed using multivariate conditional logistic regression models adjusted for family history of ADs, living in France (north/south), co-medications and co-vaccinations. RESULTS: With a total of 478 definite cases matched to 1869 referents, all ADs combined were negatively associated to HPV vaccination with an adjusted odds ratio of 0.58 (95% confidence interval: 0.41-0.83). Similar results were obtained for CD/MS, AT, CT, and T1D, the last two not reaching statistical significance. No association was found for ITP and GBS. Sensitivity analyses combining definite and possible cases with secondary time window showed similar results. CONCLUSION: Exposure to HPV vaccines was not associated with an increased risk of ADs within the time period studied. Results were robust to case definitions and time windows of exposure. Continued active surveillance is needed to confirm this finding for individual ADs.


Assuntos
Doenças Autoimunes/epidemiologia , Doenças Autoimunes/etiologia , Vacinas contra Papillomavirus/efeitos adversos , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Masculino , Razão de Chances , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/prevenção & controle , Vacinas contra Papillomavirus/imunologia , Vigilância da População , Risco , Adulto Jovem
20.
Sante Publique ; 29(2): 229-240, 2017 Apr 27.
Artigo em Francês | MEDLINE | ID: mdl-28737342

RESUMO

Objectives: To describe Self-Monitoring of Blood Glucose (SMBG) practices in France in patients with type 1 (T1DM) or type 2 (T2DM) diabetes, by estimating the proportion of patients performing SMBG at the recommended testing frequency and the proportion of patients complying with the current quality control guidelines on SMBG. Materials and methods: National cross-sectional study conducted in 238 pharmacies. A questionnaire was completed with adult diabetic patients buying SMBG devices or reagent strips for themselves, using a blood glucose meter for at least 6 months, treated with insulin or sulfonylurea/glinides ± other oral hypoglycaemic agents (HA). Results: Data from 449 patients were analysed: 85 T1DM and 121 T2DM patients treated by multiple basal-bolus injections ± HA (Group A and Group B), 123 T2DM patients treated by basal insulin ± HA (Group C), 102 patients treated by other insulin regimens ± HA (Group D) and 120 T2DM patients treated by sulfonylurea / glinides without insulin ± other HA (Group E). The recommended test frequency was observed by 29.8%, 36.4%, 61.8% and 69.2% of patients in Group A, Group B, Group C, and Group E, respectively. The quality of self-monitoring was insufficient in terms of device cleaning, storage conditions/expiry date of reagent strips, or use of control solutions. Patients displayed a limited capacity to take decisions in relation to their SMBG results (Group A: 56.5%, Group B: 70.2%, Group C: 49.2%, Group E: 36.0%) and limited knowledge about their glucose targets (Group A: 81%, Group B: 80.5%, Group C: 68.6%, Group E: 73.7%). Conclusion: SMBG use and compliance with quality guidelines must be improved, but healthcare professionals and patients must also focus their efforts on education to interpret SMBG results.


Assuntos
Automonitorização da Glicemia/estatística & dados numéricos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Adulto , Idoso , Estudos Transversais , Feminino , França , Humanos , Masculino , Cooperação do Paciente/estatística & dados numéricos , Autorrelato
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa