Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 36(20): 5654-5664, 2020 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-31721585

RESUMO

We report a diazonium electro-grafting method for the covalent modification of conducting surfaces with aldehyde-reactive hydroxylamine functionalities that facilitate the wiring of redox-active (bio)molecules to electrode surfaces. Hydroxylamine near-monolayer formation is achieved via a phthalimide-protection and hydrazine-deprotection strategy that overcomes the multilayer formation that typically complicates diazonium surface modification. This surface modification strategy is characterized using electrochemistry (electrochemical impedance spectroscopy and cyclic voltammetry), X-ray photoelectron spectroscopy, and quartz crystal microbalance with dissipation monitoring. Thus-modified glassy carbon, boron-doped diamond, and gold surfaces are all shown to ligate to small molecule aldehydes, yielding surface coverages of 150-170, 40, and 100 pmol cm-2, respectively. Bioconjugation is demonstrated via the coupling of a dilute (50 µM) solution of periodate-oxidized horseradish peroxidase enzyme to a functionalized gold surface under biocompatible conditions (H2O solvent, pH 4.5, 25 °C).

2.
Heliyon ; 8(2): e08836, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35106385

RESUMO

[This corrects the article DOI: 10.1016/j.heliyon.2021.e06905.].

3.
J Appl Crystallogr ; 51(Pt 2): 264-281, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29657564

RESUMO

A global approach coupling the moderator to the beam extraction system has been applied for the design optimization of the thermal and cold moderators of the European Spallation Source (ESS), which will be the brightest neutron source in the world for condensed-matter studies. The design is based on the recently developed high-brightness low-dimensional moderator concepts. Para-hydrogen is used for the cold neutron source, while thermal neutrons are provided by moderation in water. The overall moderation configuration was chosen in order to satisfy a range of requirements on bispectral extraction, beamport configuration and instrument performance. All instruments are served by a single moderator assembly above the target, arranged in a 'butterfly' geometry with a height of 3 cm. This was determined to be the optimal height for trade-off between high brightness and efficient guide illumination, by analysis of the performance of 23 instruments, based on the reference suite of the ESS Technical Design Report. The concept of 'brilliance transfer' is introduced to quantify the performance of the neutron optical system from the source to the sample. The target monolith incorporates a grid of 42 neutron beamports with an average separation of 6°, allowing a free choice between cold and thermal neutron sources at all instrument positions. With the large number of beamports and the space below the target available for future moderators, ample opportunities are available for future upgrades.

4.
Rev Sci Instrum ; 80(9): 095105, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19791962

RESUMO

This paper describes the design and experimental tests of a novel neutron spin analyzer optimized for wide angle spin echo spectrometers. The new design is based on nonremanent magnetic supermirrors, which are magnetized by vertical magnetic fields created by NdFeB high field permanent magnets. The solution presented here gives stable performance at moderate costs in contrast to designs invoking remanent supermirrors. In the experimental part of this paper we demonstrate that the new design performs well in terms of polarization, transmission, and that high quality neutron spin echo spectra can be measured.

5.
Breast J ; 13(3): 238-42, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17461897

RESUMO

Breast cancer surgery is an emotive topic and rather than just simple cosmetic issues, the final appearance of the operated breast has been shown to have a significant impact on psychologic well-being and overall quality of life. Wide local excision (WLE) is a popular conservative approach to small tumors, which do not involve the nipple-areolar complex. This study compares WLE via an anterior and lateral approach. A retrospective survey of patient satisfaction was performed using a recognized and validated Body Image Score (BIS), which was sent to a total of 267 patients who had undergone WLE by either the anterior or lateral approach. The response rate was 57%, of which 89 women had undergone surgery via the anterior and 80 by the lateral approach. There was no significant difference in BIS when comparing the anterior and lateral approaches, despite concerns regarding the physical appearance of the scar and postoperative breast expressed by patients. Generally, surgery on the upper part of the breast was associated with less satisfaction than the lower, but "hiding" the scar with a lateral approach did not improve satisfaction. Surgeons should be reassured that the approach to WLE of early breast cancers has no impact on the patients overall body image and that the choice of technique should be based on the patient's personal preference and the surgeons experience and skill.


Assuntos
Imagem Corporal , Neoplasias da Mama/psicologia , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/psicologia , Satisfação do Paciente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento , Saúde da Mulher
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa