Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Medicina (Kaunas) ; 59(7)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37512062

RESUMO

Objective: The primary objective of the present retrospective clinical study was to evaluate and compare the clinical performance presented by castable abutments developed for the MT system versus intermediate machined abutments, specifically regarding prosthetic or implant fractures/loss; the secondary objective was to verify the looseness of the abutments and the behavior of the peri-implant soft tissues. Methods: This clinical retrospective study was conducted on patients rehabilitated between 2019 and 2020. Inclusion criteria were patients in good general health, with an implants-supporting single crown; with solid machined abutments (control group) or castable UCLA abutments; with a connection portion (base) machined in cobalt-chrome (test group) over Morse taper DuoCone implants in the posterior mandible area; and at least two years in function. Clinical assessment was carried out by the same professional, considering the following parameters: (A) prosthetic: (i) loosening of the fixation screw, (ii) fracture of the screw and (iii) the number of times the patient had some type of complication after the installation of the prostheses were evaluated; (B) biological: (i) without keratinized mucosa (KM), (ii) 1 mm or less, (iii) between 1 and 2 mm and (iv) greater than 2 mm of KM width; and the presence or absence of mucositis. Furthermore, radiographic evaluation was performed in order to assess the marginal bone loss. These evaluations permitted to compare the groups analyzed and patients enrolled. Data were statistically analyzed, with the level of significance set at α = 0.05. Results: 79 patients with 120 MT implants were evaluated (80 castable UCLA abutments and 40 machined solid abutments). The follow-up was from 2 to 4 years. There was a 100% implant survival rate. Therefore, the control group showed two fractured abutments (5%) and no abutment loosening (95% for prosthetic survival rate), whereas the test group showed no abutment fracture but nine loosening screws (11.3%) (100% for prosthetic survival rate). Keratinized mucosa was considered thin or absent in 19 implants in the control group (47.5%) and 42 in the test group (52.5%). Mucositis was found in 11 implants in the control group (27.5%) and 27 in the test group (33.8%). A positive correlation was observed between the width of keratinized mucosa and mucositis (r = 0.521, p = 0.002). The mean marginal bone loss was 2.3 mm, ranging from 1.1 to 5.8 mm. No correlation was observed when considering marginal bone loss versus the three parameters (implant diameter, implant length and time of the prosthesis in function). Conclusions: The results suggest that UCLA-type abutments are a viable option for rehabilitating implants with Morse taper connections, suggesting lower fracture risk. Further research is necessary to confirm these findings and thoroughly evaluate the clinical performance and long-term outcomes.


Assuntos
Mucosite , Humanos , Estudos Retrospectivos , Próteses e Implantes
2.
J Oral Implantol ; 45(3): 202-206, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30875272

RESUMO

The aim of this in vitro study was to evaluate the effect of air polishing on the implant abutment surface using different abrasive powders: sodium bicarbonate and amino acid glycine. Fifteen grade III machined surface titanium disks with 8-mm diameter and 2-mm thickness were divided in 3 groups of 5 samples each and subjected to air polishing for 20 seconds with an Ultrajet Flex air-abrasive device and a distinct prophylaxis protocol: air and water (G1); air, water, and sodium bicarbonate (G2); and air, water; and amino acid glycine (G3). After the air polishing, the average roughness (Ra) of the samples was measured using an optical profilometer, and the obtained data were statistically analyzed. We found that G1 and G3 had similar Ra, while Ra values for G2 were significantly higher. This study demonstrated that air-polishing powders containing glycine had less of an effect on the roughness of the surface of titanium disks compared with sodium bicarbonate powders. Future in vivo studies will be conducted to investigate the clinical relevance of the present results.


Assuntos
Dente Suporte , Implantes Dentários , Polimento Dentário , Bicarbonato de Sódio , Teste de Materiais , Pós , Propriedades de Superfície , Titânio
3.
Implant Dent ; 27(2): 209-212, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29489548

RESUMO

OBJECTIVES: The present retrospective study assessed the clinical performance of abutment screws from prefabricated metal abutments and compared technical complication rates between straight and angled abutments. MATERIALS AND METHODS: Dental charts were selected for patients with dental implant rehabilitations delivered between 1998 and 2012. Abutment angulation, prosthetic screw type, and presence of complications that occurred during the selected time period were collected. Technical complications registered included abutment screw loosening and/or fractures detected during clinical and radiographic examinations. The chi-square test was used for statistical analysis. RESULTS: Abutment angulations were divided into 2 groups: G1) prefabricated straight abutments and G2) prefabricated angled conical mini UCLA-type abutments. A total of 916 implants (799 straight and 117 angled conical mini UCLA-type abutments) were evaluated. G1 showed 91.1% had absence of failures, which were clinically defined as any screw loosening or fracture; and 8.9% reported some type of technical complication. G2 showed 92.3% and 7.7%, with and without technical complications, respectively. CONCLUSIONS: No significant differences were observed between abutment angulation and technical complications.

4.
Clin Oral Implants Res ; 28(2): 144-150, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26754342

RESUMO

OBJECTIVES: The aim of this study was to identify systemic and local risk indicators associated with peri-implantitis. MATERIAL AND METHODS: One hundred eighty-three patients treated with 916 osseointegrated titanium implants, in function for at least 1 year, were included in the present study. The implants were installed at the Foundation for Scientific and Technological Development of Dentistry (FUNDECTO) - University of Sao Paulo (USP) - from 1998 to 2012. Factors related to patient's systemic conditions (heart disorders, hypertension, smoking habits, alcoholism, liver disorders, hepatitis, gastrointestinal disease, diabetes mellitus I and II, hyperthyroidism or hypothyroidism, radiation therapy, chemotherapy, menopause, osteoporosis, active periodontal disease, history of periodontal disease and bruxism), implant's characteristics (location, diameter, length, connection, shape, and antagonist), and clinical parameters (wear facets, periodontal status on the adjacent tooth, plaque accumulation on the adjacent tooth, modified plaque index, sulcus bleeding index, probing depth, bleeding on probing, width of keratinized tissue and marginal recession). RESULTS: An increased risk of 2.2 times for history of periodontal disease (PD), 3.6 times for cemented restorations compared to screw-retained prostheses, 2.4 times when wear facets were displayed on the prosthetic crown and 16.1 times for total rehabilitations when compared to single rehabilitations were found. Logistic regression analysis did not show any association between the implant's characteristics and peri-implantitis. CONCLUSIONS: A history of periodontal disease, cemented prostheses, presences of wear facets on the prosthetic crown and full mouth rehabilitations were identified as risk indicators for peri-implantitis. Implants' characteristics were not related to the presence of peri-implantitis.


Assuntos
Peri-Implantite/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Coroas/efeitos adversos , Planejamento de Prótese Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca Edêntula/reabilitação , Periodontite/complicações , Fatores de Risco , Desgaste dos Dentes/complicações
5.
Implant Dent ; 25(3): 341-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26840269

RESUMO

OBJECTIVE: To analyze the temperature increase in the implant, adjacent bone, procedure time, and roughness provided by different rotatory instruments in the implantoplasty procedure. MATERIAL AND METHODS: Three types of rotational instruments were used to evaluate the implant surface wear, divided according to their surface features: Group 1 (G1) diamond, Group 2 (G2) tungsten carbide, and Group 3 (G3) multilaminar. For the roughness test, a control group was included for comparison with the test groups. RESULTS: The temperature variation was statistically significant in the implant (P < 0.05) where G2 showed the lowest variation. There was no statistically significant difference between the 3 groups regarding the temperature increase measured in the bone (P > 0.05). The difference of wear time was statistically significant (P < 0.05) with faster results for G3. In the surface roughness analyses, there was a statistically significant difference (P < 0.05) between the control group and the test groups. Among the 3 test groups, the difference between measurements was not statistically significant (P > 0.05). CONCLUSION: All tested rotatory instruments performed the same level of surface roughness in the implantoplasty. The tungsten carbide bur caused a minor change in the implant temperature. The multilaminar bur performed a faster wear time. More in vivo studies are necessary to conclude which is the best rotatory instrument for implantoplasty.


Assuntos
Polimento Dentário/métodos , Implantação Dentária/métodos , Polimento Dentário/instrumentação , Falha de Restauração Dentária , Humanos , Técnicas In Vitro , Peri-Implantite/terapia , Propriedades de Superfície , Temperatura
6.
Artigo em Inglês | MEDLINE | ID: mdl-37655972

RESUMO

OBJECTIVES: The aim of the present case series is to exhibit the long-term clinical and radiographic outcomes of resective surgery with adjunctive implantoplasty over a 6-to-11-year follow-up. MATERIALS AND METHODS: Four patients presenting 4 implants diagnosed with peri-implantitis according a to an established case definition were included in the present case series. Subjects underwent resective surgery, a modified implantoplasty approach, and implant surface decontamination. Clinical and radiographic outcomes such as bleeding on probing (BOP), suppuration on probing (SoP), probing depth (PD), marginal recession (MR), modified plaque index (mPI), and marginal bone levels (MBL) were recorded over a long-term following surgical therapy. RESULTS: Over 6-to-11-year follow-up, mean BOP, PD, and SoP scores amounted to 17 ±24%, 2.5 ±1.26 mm, and 0%, respectively. BOP scores were reduced in 17%, PD values in 2.5mm, and SoP scores in 100%. Radiographic analysis revealed a mean radiographic bone gain of 3.1 ± 1.84 mm. Peri-implant marginal bone loss surface area decreased by 5.7±3.77mm2 over the long-term follow-up. CONCLUSION: Resective therapy with adjunctive implantoplasty promoted favorable clinical and radiographic outcomes at peri-implantitis treated sites over a long-term period. CLINICAL RELEVANCE: Diverse surgical approaches such as resective, reconstructive, and combined therapy have been proposed towards peri-implantitis treatment. A resective surgical approach with an adjunctive "modified" implantoplasty refers to the modification of the implant body into a constricted area to mimic a "waist" silhouette. This modified technique conforms an adequate concave smooth area that may favor the outcomes of resective surgical therapy for soft tissue adaptation, biofilm control, and possible peri-implant bone gain over the long term.

7.
J Periodontol ; 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37846763

RESUMO

BACKGROUND: Peri-implant disease prevalence is associated with a multifactorial etiology and distinct clinical characteristics of inflammation. METHODS: The present study aimed to assess the prevalence of peri-implant diseases, identify related risk indicators, and associate specific clinical characteristics to peri-implant biological complications in the medium term. Peri-implant diseases were classified according to established case criteria. Patients' data, implant and/or prosthetic features, and maintenance records were collected. Clinical characteristics such as bleeding on probing (BOP), suppuration (SUPP), keratinized mucosa (KM), probing depth (PD), marginal recession (MR), and modified plaque index (mPI) were recorded. RESULTS: Ninety-nine patients with 266 implants with a mean functional duration of 30.26 months were evaluated. Peri-implant mucositis and peri-implantitis prevalence totaled to 49.5% and 15.15% (patient level), respectively. Peri-implant mucositis was associated with osteoporosis (odds ratio [OR] 6.09), age (OR 0.97), diabetes mellitus (OR 3.09), cemented-retained prosthesis (OR 3.81), and partial prosthesis (OR 2.21). Peri-implantitis was associated with osteoporosis (OR 7.74) and periodontitis (OR 2.74), cemented prosthesis (OR 10.12), partial and full arch prostheses (OR 12.35 and 19.86), implant diameter (OR 3.64), abutment transmucosal height (OR 3.39), and hygiene difficulty (OR 3.14). Furthermore, mPI score 3 (OR 3.27) and PD scores (OR 1.64) were associated with peri-implant mucositis, while mPI score 3 (OR 16.42), KM (OR 1.53), PD (OR 1.81), MR (OR 2.61), and the relationship between KM and PD (OR 0.63) were associated with peri-implantitis. CONCLUSION: In the medium term, peri-implant diseases were correlated with factors inherent to the patient's conditions, presurgical treatment plan, and hygiene maintenance care. The knowledge of the mentioned factors and featured clinical characteristics can be crucial for disease prevention and establishment of a superior implant therapy prognosis.

8.
PLoS One ; 18(1): e0280684, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36662887

RESUMO

OBJECTIVE: The aim of the present in vitro study was to evaluate the resistance on quasi-static forces and in the fatigue mechanical cycling of a new implant design compared to two other conventional implant designs. MATERIALS AND METHODS: Eighty-eight implants with their respective abutments were tested and distributed into four groups (n = 22 per group): Morse taper connection implant (MT group), conventional external hexagon implant (EH con group), new Collo implant of external hexagon with the smooth portion out of the bone insertion (EH out group), and new Collo implant of external hexagon with the implant platform inserted to the bone level (EH bl group). All the sets were subjected to quasi-static loading in a universal testing machine, and we measured the maximum resistance force supported by each sample. Another 12 samples from each group were submitted to the cyclic fatigue test at 4 intensities of forces (n = 3 per force): 80%, 60%, 40%, and 20%. The number of cycles supported by each sample at each force intensity was evaluated. RESULTS: The three groups of implants with external hexagon connection had similar maximum strength values of the sets (p > 0.05). Meanwhile, samples from the MT group showed the highest resistance values in comparison to the other three groups (p < 0.05). In the fatigue test, the Collo out group supported a smaller number of cycles that led to the fracture than the other 3 groups proposed at loads of 80%, 60%, and 40%, and only at the load value of 20% all groups had the same performance. CONCLUSIONS: Within the limitations of the present in vitro study, the results showed that the new Collo implant performs better when installed at bone level.


Assuntos
Osso e Ossos , Implantes Dentários , Análise do Estresse Dentário , Dente Suporte
9.
J Funct Biomater ; 14(3)2023 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-36976052

RESUMO

The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12-18 months, 34 between 19-24 months, and 44 between 25-33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was -0.67 ± 0.65 mm in mesial and -0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments' diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, -0.57 ± 0.53 mm (mesial) and -0.66 ± 0.50 mm (distal), and -0.78 ± 0.75 mm (mesial) and -0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study.

10.
J Oral Implantol ; 38(5): 581-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20690832

RESUMO

The objective of this study was to assess and compare bone loss (BL) around the dental implant platform as well as the presence of bacterial plaque (PBP), bleeding on probing (BOP), and periodontal probing depths (PD) of teeth and dental implants of smokers and nonsmokers. Three hundred forty-seven teeth and 98 implants of 20 randomly selected patients were assessed (12 smokers and 8 nonsmokers). The specimens were divided into 4 groups according to the site probed. Group 1 included smoker implant sites, group 2 included smoker tooth sites, group 3 included nonsmoker implant sites, and group 4 included nonsmoker tooth sites. The presence/absence of visible bacterial plaque, presence/absence of BOP, PD ≤ 3 mm or >3 mm, and BL around the dental implant platform were the data assessed. The PBP and BL showed statistical significance between smokers and nonsmokers. Bleeding on probing and PD ≤ 3 mm showed statistical significance between groups 1, 3, and 4. Comparing sites with BOP and PD > 3 mm, there was no statistical significance except for group 1, which did not present sites with these characteristics. Comparing sites with BOP and PD ≤ 3 mm, there was statistical significance between group 2 and groups 3 and 4. When comparing the prevalence of sites without BOP and PD > 3 mm, there was statistical significance between groups 1, 3, and 4. Smoking promotes a greater BL around the dental implant platform and results in vasoconstriction of the peri-implant and periodontal tissues.


Assuntos
Perda do Osso Alveolar/etiologia , Implantes Dentários , Falha de Restauração Dentária , Fumar/efeitos adversos , Adulto , Idoso , Perda do Osso Alveolar/patologia , Estudos de Casos e Controles , Índice de Placa Dentária , Restauração Dentária Permanente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Índice Periodontal , Estudos Retrospectivos
11.
J Prosthodont ; 21(3): 191-3, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22494257

RESUMO

Although unusual, foreign body ingestion occurs in dentistry and may result in serious complications, such as intestinal perforation. The presence of the foreign body should be confirmed with the use of radiographs. The exam will allow the correct diagnosis and the treatment to be conducted according to the specific situation of the object in the gastrointestinal (GI) tract. The orientation of the patient as well as the awareness of the patient's medical history are key factors in preventing serious complications. Generally, instruments that enter the GI tract pass asymptomatically and atraumatically within 4 days to 2 weeks. Sometimes, a surgical approach is necessary to remove the instrument when there is bleeding, obstruction, or impaction in the GI tract. Thus, a correct diagnosis is vital to avoid unnecessary surgical interventions. The aim of this article is to report an accidental ingestion of a screwdriver by a patient who had previously undergone a hemi-mandibulectomy and its medical resolution.


Assuntos
Acidentes , Deglutição , Implantação Dentária Endóssea/efeitos adversos , Corpos Estranhos/etiologia , Adulto , Colo Transverso/cirurgia , Colostomia/métodos , Implantação Dentária Endóssea/instrumentação , Feminino , Seguimentos , Corpos Estranhos/cirurgia , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/cirurgia , Humanos , Laparotomia/métodos , Mandíbula/cirurgia , Osteotomia , Conduta Expectante
12.
Int J Periodontics Restorative Dent ; 41(4): e157-e165, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34328477

RESUMO

Using autogenous grafts in mucogingival surgeries is related to postoperative morbidity and limited tissue availability, and thus xenogeneic matrices are increasingly used. This in vitro study evaluated the influence of xenogeneic collagen matrix thickness on cell adhesion, morphology, viability, proliferation, and matrix degradation. Matrices were divided into three groups: SLC: single layer of Lumina Coat, as commercially available (2-mm thickness); DLC: double layer of SLC (Lumina Coat); and MG: single layer of Mucograft, as commercially available (4-mm thickness). SEM was used to evaluate the matrix surface topographies. To evaluate the cell viability, proliferation, adhesion, and morphology, human gingival fibroblasts (HGF) and stem cells from human exfoliated deciduous teeth (SHED) were used. Cell viability was evaluated through MTS colorimetric method evaluating HGF and SHED on days 1, 3, and 7. Cell proliferation was assessed by PicoGreen assay, evaluating HGF and SHED on days 3 and 7. Sample degradation was evaluated on days 1, 3, 7, 14, 21, 28, and 35. All groups were biocompatible for HGF and SHED, showing viabilities > 70% on days 1, 3, and 7. DCL promoted HGF viabilities similar to MG (P = .2828) and the highest SHED viability (P < .0001) on day 1. DLC also demonstrated HGF and SHED proliferations higher than the positive control (MG; P < .05) on day 7. SLC was completely degraded on day 14, while DLC and MG presented 48.41% and 20.52% of their initial mass, respectively, on day 35. Increasing the matrix thickness improved HGF and SHED viability and proliferation and prevented early matrix degradation. DLC demonstrated better results than SLC and MG concerning matrix degradation and HGF and SHED viability and proliferation.


Assuntos
Células-Tronco Mesenquimais , Proliferação de Células , Células Cultivadas , Colágeno , Fibroblastos , Humanos
13.
Quintessence Int ; 52(3): 248-256, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33491394

RESUMO

Objective: This study analyzed two xenogenous biomaterials based on deproteinized bovine bone mineral applied for maxillary sinus elevation. Method and materials: Fourteen patients were submitted to maxillary sinus augmentation with one of the following biomaterials: Criteria Lumina Bone Porous (test group) or Geistlich Bio-Oss (control group), both of large granules (1 to 2 mm). After 6 months, trephine biopsies were collected at the time of implant placement: 27 samples (11 patients) in the test group; 7 samples (3 patients) in the control group. Biopsies were analyzed by descriptive histology and histomorphometry, in which the percentages of newly formed bone, residual biomaterial particles, and connective tissue were evaluated. Results: Histomorphometry showed means for test and control groups, respectively, of 32.41% ± 9.42% and 26.59% ± 4.88% for newly formed bone, 22.89% ± 4.58% and 25.00% ± 4.81% for residual biomaterial, and 44.70% ± 9.54% and 48.41% ± 3.36% for connective tissue. There were no differences between groups (P > .05). Conclusion: This study concluded that Criteria Lumina Bone Porous presented similar histologic and histomorphometric characteristics to Geistlich Bio-Oss 6 months after sinus elevation surgery, identifying the tested biomaterial as an interesting alternative for bone augmentation in the maxillary sinus.


Assuntos
Substitutos Ósseos , Levantamento do Assoalho do Seio Maxilar , Animais , Materiais Biocompatíveis , Transplante Ósseo , Bovinos , Implantação Dentária Endóssea , Humanos , Maxila , Seio Maxilar/cirurgia , Minerais
14.
Artigo em Inglês | MEDLINE | ID: mdl-31815972

RESUMO

Implantoplasty has been claimed as a promising strategy to treat peri-implantitis and prevent progressive peri-implant bone loss. Consequently, the aim of the present case series is to exhibit the clinical outcomes of a 3-year-follow-up resective and implantoplasty therapy applying a novel platform-switch concept to preserve peri-implant tissue integrity and counteract progressive bone loss. Four patients who underwent dental implant therapy and were diagnosed with peri-implantitis were treated through access flap surgery, a modified implantoplasty, bone recontouring, and surface decontamination. The radiographic and clinical parameters recorded before and during the 3-year follow-up were: marginal bone loss (MBL) as the primary endpoint, bleeding on probing index (BOP), probing depth (PD), presence of suppuration, pain, mobility, and fracture. The 3-year follow-up exhibited peri-implant bone stability in all cases (100%) showing radiographically an MBL reduction (mean) of 0.8 ± 0.5 mm (mesial) and 0.5 ± 0.3 mm (distal). Mean PD reduction was 4.75 ± 1 mm and mean BOP was reduced by 71%. Pain and suppuration were resolved in all cases. None of the cases reported implant fracture or mobility after the modified implantoplasty therapy. The present case series demonstrated that this modified implantoplasty can be more than a surface decontamination therapy where the narrow and smooth exposed implant surface can counteract peri-implantitis alterations providing favorable biologic conditions to maintain stability of peri-implant tissues.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Peri-Implantite , Procedimentos de Cirurgia Plástica , Humanos , Índice Periodontal , Retalhos Cirúrgicos
15.
Dent J (Basel) ; 8(3)2020 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-32759635

RESUMO

We investigated the effects of two common dietary supplements on bone healing in dental extraction sockets in humans. In this randomized pilot trial, male subjects took Grape Seed Extract [GSE] or Grapefruit Extract [GFE] starting two weeks prior to dental extraction and maintained this regimen for sixty days after surgery. Extraction sockets were filled with a collagen plug. After 24 h, a socket sample was collected and processed for quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR) and an 84-gene wound healing assay. Sixty days after tooth extraction, a core of newly formed bone was obtained prior to dental implant placement and processed for histology. qRT-PCR revealed that GFE led to a significant decrease in platelet-derived growth factor and interleukin (IL)1-ß compared to GSE, and a significant decrease in IL-6 and CXCL2 compared to control. GSE led to a significant increase in coagulation factor Von Willebrand and inflammatory marker IL1-ß compared to GFE. WISP1 and CXCL5 were upregulated in both groups. Overall, GFE showed a downregulation of inflammation and GSE led to a decrease in collagen density and increased osteoclasts. This pilot trial highlights the need for further investigation on the mechanism of action of such supplements on bone healing and oral health.

16.
Int J Periodontics Restorative Dent ; 29(6): 643-7, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20072742

RESUMO

Freeze-dried bone allograft is an interesting treatment alternative to autogenous bone grafts. This clinical report presents a 3-year follow-up of an atrophic maxilla treated with freeze-dried bone allograft. Ridge augmentation was conducted with freeze-dried tibial allografts. Eight implants were used to support a full-arch prosthesis. Three years later, clinical and radiographic follow-up showed bone surrounding the dental implants. Histologic sections showed the presence of biologically active bone. This clinical case supports the use of freeze-dried allograft as an alternative for the reconstruction of the atrophic maxilla.


Assuntos
Aumento do Rebordo Alveolar/métodos , Transplante Ósseo/métodos , Implantação Dentária Endóssea , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Liofilização , Humanos , Arcada Edêntula/reabilitação , Masculino , Pessoa de Meia-Idade , Plasma Rico em Plaquetas
17.
J Periodontol ; 86(6): 827-34, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25786563

RESUMO

BACKGROUND: Demineralized bone matrix (DBM) is used for the treatment of osseous defects. Conditioned medium from native bone chips can activate transforming growth factor (TGF)-ß signaling in mesenchymal cells. The aim of this study is to determine whether processing of native bone into DBM affects the activity of the conditioned medium. METHODS: Porcine cortical bone blocks were subjected to defatting, different concentrations of hydrochloric acid, and various temperatures. DBM was lyophilized, ground, and placed into culture medium. Human gingiva and periodontal fibroblasts were exposed to the respective conditioned medium obtained from DBM (DBCM). Changes in the expression of TGF-ß target genes were determined. RESULTS: DBCM altered the expression of TGF-ß target genes (e.g., adrenomedullin, pentraxin 3, KN motif and ankyrin repeat domains 4, interleukin 11, NADPH oxidase 4, and BTB [POZ] domain containing 11) by at least five-fold. The response was observed in fibroblasts from both sources. Defatting lowered the activity of DBCM. The TGF-ß receptor type I kinase inhibitor SB431542 [4-(4-(benzo[d][1,3]dioxol-5-yl)-5-(pyridin-2-yl)-1H-imidazol-2-yl)benzamide] but not the inhibitor of bone morphogenetic protein receptor dorsomorphin, blocked the effects of DBCM on gene expression. Moreover, conditioned medium obtained from commercial human DBM modulated the expression of TGF-ß target genes. CONCLUSION: The findings suggest that the DBCM can activate TGF-ß signaling in oral fibroblasts.


Assuntos
Matriz Óssea/fisiologia , Gengiva/metabolismo , Periodonto/metabolismo , Preservação de Tecido/métodos , Fator de Crescimento Transformador beta/metabolismo , Proteínas Quinases Ativadas por AMP/antagonistas & inibidores , Proteínas de Fase Aguda/análise , Adrenomedulina/análise , Animais , Repetição de Anquirina/genética , Benzamidas/farmacologia , Técnica de Desmineralização Óssea , Matriz Óssea/efeitos dos fármacos , Proteína C-Reativa/análise , Linhagem Celular , Células Cultivadas , Meios de Cultivo Condicionados , Dioxóis/farmacologia , Fibroblastos/metabolismo , Liofilização , Gengiva/citologia , Humanos , Ácido Clorídrico/química , Interleucina-11/análise , Células-Tronco Mesenquimais/metabolismo , Camundongos , NADPH Oxidase 4 , NADPH Oxidases/análise , Proteínas Nucleares/análise , Periodonto/citologia , Pirazóis/farmacologia , Pirimidinas/farmacologia , Receptores de Fatores de Crescimento Transformadores beta/antagonistas & inibidores , Componente Amiloide P Sérico/análise , Transdução de Sinais/efeitos dos fármacos , Transdução de Sinais/fisiologia , Suínos , Fator de Crescimento Transformador beta/efeitos dos fármacos
18.
Case Rep Dent ; 2014: 795808, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25580309

RESUMO

The most aggressive diseases that affect the oral environment are considered tumors of the jaw. The surgical treatment is preferably done by surgical resection of the lesion, resulting in a great loss of tissue and esthetics. Multidisciplinary planning is required for the rehabilitation of these cases. Autogenous grafting techniques or vascularized flaps allow ridge reconstruction for implant placement, restoring function, and esthetics. This paper reports a 6-year follow-up case of an odontogenic myxoma treated with wide resection and mandibular bone reconstruction for posterior rehabilitation with dental implants.

19.
J Appl Oral Sci ; 22(5): 403-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25466474

RESUMO

OBJECTIVE: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. MATERIAL AND METHODS: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1) ≤5 implants and G2) >5 implants. Data collection included modified plaque index (MPi), bleeding on probing (BOP), probing depth (PD), width of keratinized mucosa (KM) and radiographic bone loss (BL). Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. RESULTS: Clinical parameters were compared between groups using Student's t test for numeric variables (KM, PD and BL) and Mann-Whitney test for categorical variables (MPi and BOP). KM and BL showed statistically significant differences between both groups (p<0.001). Implants from G1 - 19 (20.43%)--compared with G2 - 26 (38.24%)--showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210). CONCLUSION: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.


Assuntos
Implantes Dentários/efeitos adversos , Prótese Dentária Fixada por Implante/efeitos adversos , Mucosite/etiologia , Peri-Implantite/etiologia , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/etiologia , Índice de Placa Dentária , Falha de Restauração Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Bucal , Mucosite/diagnóstico por imagem , Peri-Implantite/diagnóstico por imagem , Índice Periodontal , Radiografia , Fatores de Risco , Estatísticas não Paramétricas , Fatores de Tempo
20.
Quintessence Int ; 45(10): 861-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25126637

RESUMO

OBJECTIVE: The purpose of this study was to evaluate periimplantitis prevalence in patients using implant-supported fixed prostheses that did not have any routine maintenance care. METHOD AND MATERIALS: A total of 161 implants (27 patients) were evaluated in patients using implant-supported fixed prostheses. Collected data included information related to patient general health and local factors such as characteristics of implants, time in function, type of loading, positioning, Modified Bleeding Index, bacterial plaque, bleeding on probing (BOP), marginal recession, probing depth (PD), keratinized mucosa, and radiographic bone loss (BL). Factors related to the prostheses were also evaluated. The exclusion criteria were patients that have had any follow-up visit for plaque control of the prosthesis and/or the implants. RESULTS: From a total of 161 implants, 116 (72%) presented without peri-implantitis (PD > 4 mm + BOP + BL > 2 mm) while 45 (28%) had some sign of the disease. Implants placed in the maxilla were 2.98 times more likely to develop the disease (P < .05). Moreover, patients aged ≤ 60 years old were 3.24 times more likely to develop peri-implantitis (P < .05). Another analysis with statistical relevance (P < .05) was that implants with less than 3 mm interimplant distance were three times more likely to have peri-implantitis. There was no statistical relevance considering other analyses. CONCLUSION: It can be concluded that patients aged ≤ 60 years have a greater chance of presenting periimplantitis, as well as for implants positioned in the maxilla and those placed with an interimplant distance < 3 mm.


Assuntos
Prótese Dentária Fixada por Implante/estatística & dados numéricos , Peri-Implantite/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/epidemiologia , Brasil/epidemiologia , Índice de Placa Dentária , Planejamento de Dentadura/estatística & dados numéricos , Feminino , Seguimentos , Retração Gengival/epidemiologia , Humanos , Queratinas , Masculino , Maxila/cirurgia , Pessoa de Meia-Idade , Higiene Bucal/estatística & dados numéricos , Índice Periodontal , Bolsa Periodontal/epidemiologia , Prevalência , Radiografia Interproximal/estatística & dados numéricos , Radiografia Dentária Digital/estatística & dados numéricos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa