Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Crit Care Med ; 50(5): e468-e476, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35044966

RESUMO

OBJECTIVES: Extracorporeal carbon dioxide removal is used to treat patients suffering from acute respiratory failure. However, the procedure is hampered by the high blood flow required to achieve a significant CO2 clearance. We aimed to develop an ultralow blood flow device to effectively remove CO2 combined with continuous renal replacement therapy (CRRT). DESIGN: Preclinical, proof-of-concept study. SETTING: An extracorporeal circuit where 200 mL/min of blood flowed through a hemofilter connected to a closed-loop dialysate circuit. An ion-exchange resin acidified the dialysate upstream, a membrane lung to increase Pco2 and promote CO2 removal. PATIENTS: Six, 38.7 ± 2.0-kg female pigs. INTERVENTIONS: Different levels of acidification were tested (from 0 to 5 mEq/min). Two l/hr of postdilution CRRT were performed continuously. The respiratory rate was modified at each step to maintain arterial Pco2 at 50 mm Hg. MEASUREMENTS AND MAIN RESULTS: Increasing acidification enhanced CO2 removal efficiency of the membrane lung from 30 ± 5 (0 mEq/min) up to 145 ± 8 mL/min (5 mEq/min), with a 483% increase, representing the 73% ± 7% of the total body CO2 production. Minute ventilation decreased accordingly from 6.5 ± 0.7 to 1.7 ± 0.5 L/min. No major side effects occurred, except for transient tachycardia episodes. As expected from the alveolar gas equation, the natural lung Pao2 dropped at increasing acidification steps, given the high dissociation between the oxygenation and CO2 removal capability of the device, thus Pao2 decreased. CONCLUSIONS: This new extracorporeal ion-exchange resin-based multiple-organ support device proved extremely high efficiency in CO2 removal and continuous renal support in a preclinical setting. Further studies are required before clinical implementation.


Assuntos
Terapia de Substituição Renal Contínua , Animais , Dióxido de Carbono , Soluções para Diálise , Feminino , Humanos , Oxigênio , Respiração Artificial/métodos , Suínos
2.
Am J Respir Crit Care Med ; 204(8): 933-942, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34252009

RESUMO

Rationale: Unilateral ligation of the pulmonary artery may induce lung injury through multiple mechanisms, which might be dampened by inhaled CO2. Objectives: This study aims to characterize bilateral lung injury owing to unilateral ligation of the pulmonary artery in healthy swine undergoing controlled mechanical ventilation and its prevention by 5% CO2 inhalation and to investigate relevant pathophysiological mechanisms. Methods: Sixteen healthy pigs were allocated to surgical ligation of the left pulmonary artery (ligation group), seven to surgical ligation of the left pulmonary artery and inhalation of 5% CO2 (ligation + FiCO2 5%), and six to no intervention (no ligation). Then, all animals received mechanical ventilation with Vt 10 ml/kg, positive end-expiratory pressure 5 cm H2O, respiratory rate 25 breaths/min, and FiO2 50% (±FiCO2 5%) for 48 hours or until development of severe lung injury. Measurements and Main Results: Histological, physiological, and quantitative computed tomography scan data were compared between groups to characterize lung injury. Electrical impedance tomography and immunohistochemistry analysis were performed in a subset of animals to explore mechanisms of injury. Animals from the ligation group developed bilateral lung injury as assessed by significantly higher histological score, larger increase in lung weight, poorer oxygenation, and worse respiratory mechanics compared with the ligation + FiCO2 5% group. In the ligation group, the right lung received a larger fraction of Vt and inflammation was more represented, whereas CO2 dampened both processes. Conclusions: Mechanical ventilation induces bilateral lung injury within 48 hours in healthy pigs undergoing left pulmonary artery ligation. Inhalation of 5% CO2 prevents injury, likely through decreased stress to the right lung and antiinflammatory effects.


Assuntos
Dióxido de Carbono/uso terapêutico , Modelos Animais de Doenças , Lesão Pulmonar/prevenção & controle , Substâncias Protetoras/uso terapêutico , Artéria Pulmonar/cirurgia , Respiração Artificial/efeitos adversos , Suínos/cirurgia , Administração por Inalação , Animais , Feminino , Ligadura , Lesão Pulmonar/etiologia , Lesão Pulmonar/fisiopatologia , Lesão Pulmonar/terapia , Resultado do Tratamento
3.
Perfusion ; 33(7): 577-583, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29783879

RESUMO

INTRODUCTION: Citric acid infusion in extracorporeal blood may allow concurrent regional anticoagulation and enhancement of extracorporeal CO2 removal. Effects of citric acid on human blood thromboelastography and aggregometry have never been tested before. METHODS: In this in vitro study, citric acid, sodium citrate and lactic acid were added to venous blood from seven healthy donors, obtaining concentrations of 9 mEq/L, 12 mEq/L and 15 mEq/L. We measured gas analyses, ionized calcium (iCa++) concentration, activated clotting time (ACT), thromboelastography and multiplate aggregometry. Repeated measure analysis of variance was used to compare the acidifying and anticoagulant properties of the three compounds. RESULTS: Sodium citrate did not affect the blood gas analysis. Increasing doses of citric and lactic acid progressively reduced pH and HCO3- and increased pCO2 (p<0.001). Sodium citrate and citric acid similarly reduced iCa++, from 0.39 (0.36-0.39) and 0.35 (0.33-0.36) mmol/L, respectively, at 9 mEq/L to 0.20 (0.20-0.21) and 0.21 (0.20-0.23) mmol/L at 15 mEq/L (p<0.001). Lactic acid did not affect iCa++ (p=0.07). Sodium citrate and citric acid similarly incremented the ACT, from 234 (208-296) and 202 (178-238) sec, respectively, at 9 mEq/L, to >600 sec at 15 mEq/L (p<0.001). Lactic acid did not affect the ACT values (p=0.486). Sodium citrate and citric acid similarly incremented R-time and reduced α-angle and maximum amplitude (MA) (p<0.001), leading to flat-line thromboelastograms at 15 mEq/L. Platelet aggregometry was not altered by any of the three compounds. CONCLUSIONS: Citric acid infusions determine acidification and anticoagulation of blood similar to lactic acid and sodium citrate, respectively.


Assuntos
Anticoagulantes/uso terapêutico , Coagulação Sanguínea/efeitos dos fármacos , Ácido Cítrico/uso terapêutico , Ácido Láctico/uso terapêutico , Citrato de Sódio/uso terapêutico , Anticoagulantes/farmacologia , Ácido Cítrico/farmacologia , Feminino , Voluntários Saudáveis , Humanos , Ácido Láctico/farmacologia , Masculino , Citrato de Sódio/farmacologia
4.
Minerva Anestesiol ; 89(9): 773-782, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36951601

RESUMO

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) promotes protective ventilation in patients with acute respiratory failure, but devices with high CO2 extraction capacity are required for clinically relevant impact. This study evaluates three novel low-flow techniques based on dialysate acidification, also combined with renal replacement therapy, and metabolic control. METHODS: Eight swine were connected to a low-flow (350 mL/min) extracorporeal circuit including a dialyzer with a closed-loop dialysate circuit, and two membrane lungs on blood (MLb) and dialysate (MLd), respectively. The following 2-hour steps were performed: 1) MLb-start (MLb ventilated); 2) MLbd-start (MLb and MLd ventilated); 3) HLac (lactic acid infusion before MLd); 4) HCl-NaLac (hydrochloric acid infusion before MLd combined with renal replacement therapy and reinfusion of sodium lactate); 5) HCl-ßHB-NaLac (hydrochloric acid infusion before MLd combined with renal replacement therapy and reinfusion of sodium lactate and sodium 3-hydroxybutyrate). Caloric and fluid inputs, temperature, blood glucose and arterial carbon dioxide pressure were kept constant. RESULTS: The total MLs CO2 removal in HLac (130±25 mL/min), HCl-NaLac (130±21 mL/min) and HCl-ßHB-NaLac (124±18 mL/min) were higher compared with MLbd-start (81±15 mL/min, P<0.05) and MLb-start (55±7 mL/min, P<0.05). Minute ventilation in HLac (4.3±0.9 L/min), HCl-NaLac (3.6±0.8 L/min) and HCl-ßHB-NaLac (3.6±0.8 L/min) were lower compared to MLb-start (6.2±1.1 L/min, P<0.05) and MLbd-start (5.8±2.1 L/min, P<0.05). Arterial pH was 7.40±0.03 at MLb-start and decreased only during HCl-ßHB-NaLac (7.35±0.03, P<0.05). No relevant changes in electrolyte concentrations, hemodynamics and significant adverse events were detected. CONCLUSIONS: The three techniques achieved a significant extracorporeal CO2 removal allowing a relevant reduction in minute ventilation with a sufficient safety profile.


Assuntos
Dióxido de Carbono , Respiração Artificial , Animais , Suínos , Respiração Artificial/métodos , Lactato de Sódio , Ácido Clorídrico , Concentração de Íons de Hidrogênio , Soluções para Diálise
5.
Front Med (Lausanne) ; 9: 901809, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35669918

RESUMO

Background: Unilateral ligation of the pulmonary artery (UPAL) induces bilateral lung injury in pigs undergoing controlled mechanical ventilation. Possible mechanisms include redistribution of ventilation toward the non-ligated lung and hypoperfusion of the ligated lung. The addition of 5% CO2 to the inspiratory gas (FiCO2) prevents the injury, but it is not clear whether lung protection is a direct effect of CO2 inhalation or it is mediated by plasmatic hypercapnia. This study aims to compare the effects and mechanisms of FiCO2 vs. hypercapnia induced by low tidal volume ventilation or instrumental dead space. Methods: Healthy pigs underwent left UPAL and were allocated for 48 h to the following: Volume-controlled ventilation (VCV) with VT 10 ml/kg (injury, n = 6); VCV plus 5% FiCO2 (FiCO2, n = 7); VCV with VT 6 ml/kg (low VT, n = 6); VCV plus additional circuit dead space (instrumental VD, n = 6). Histological score, regional compliance, wet-to-dry ratio, and inflammatory infiltrate were assessed to evaluate lung injury at the end of the study. To investigate the mechanisms of protection, we quantified the redistribution of ventilation to the non-ligated lung, as the ratio between the percentage of tidal volume to the right and to the left lung (VTRIGHT/LEFT), and the hypoperfusion of the ligated lung as the percentage of blood flow reaching the left lung (PerfusionLEFT). Results: In the left ligated lung, injury was prevented only in the FiCO2 group, as indicated by lower histological score, higher regional compliance, lower wet-to-dry ratio and lower density of inflammatory cells compared to other groups. For the right lung, the histological score was lower both in the FiCO2 and in the low VT groups, but the other measures of injury showed lower intensity only in the FiCO2 group. VTRIGHT/LEFT was lower and PerfusionLEFT was higher in the FiCO2 group compared to other groups. Conclusion: In a model of UPAL, inhaled CO2 but not hypercapnia grants bilateral lung protection. Mechanisms of protection include reduced overdistension of the non-ligated and increased perfusion of the ligated lung.

6.
J Clin Med ; 11(11)2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35683455

RESUMO

The acceptable duration of donor warm ischemia time (DWIT) after cardiocirculatory death (DCD) is still debated. We analyzed the biomolecular profile and function during ex vivo lung perfusion (EVLP) of DCD lungs and their correlation with lung transplantation (LuTx) outcomes. Donor data, procurement times, recipient outcomes, and graft function up to 1 year after LuTx were collected. During EVLP, the parameters of graft function and metabolism, perfusate samples to quantify inflammation, glycocalyx breakdown products, coagulation, and endothelial activation markers were obtained. Data were compared to a cohort of extended-criteria donors after brain death (EC-DBD). Eight DBD and seven DCD grafts transplanted after EVLP were analyzed. DCD's DWIT was 201 [188;247] minutes. Donors differed only regarding the duration of mechanical ventilation that was longer in the EC-DBD group. No difference was observed in lung graft function during EVLP. At reperfusion, "wash-out" of inflammatory cells and microthrombi was predominant in DCD grafts. Perfusate biomolecular profile demonstrated marked endothelial activation, characterized by the presence of inflammatory mediators and glycocalyx breakdown products both in DCD and EC-DBD grafts. Early graft function after LuTx was similar between DCD and EC-DBD. DCD lungs exposed to prolonged DWIT represent a potential resource for donation if properly preserved and evaluated.

7.
Front Physiol ; 12: 663313, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33897471

RESUMO

Rationale: Reducing the respiratory rate during extracorporeal membrane oxygenation (ECMO) decreases the mechanical power, but it might induce alveolar de-recruitment. Dissecting de-recruitment due to lung edema vs. the fraction due to hypoventilation may be challenging in injured lungs. Objectives: We characterized changes in lung physiology (primary endpoint: development of atelectasis) associated with progressive reduction of the respiratory rate in healthy animals on ECMO. Methods: Six female pigs underwent general anesthesia and volume control ventilation (Baseline: PEEP 5 cmH2O, Vt 10 ml/kg, I:E = 1:2, FiO2 0.5, rate 24 bpm). Veno-venous ECMO was started and respiratory rate was progressively reduced to 18, 12, and 6 breaths per minute (6-h steps), while all other settings remained unchanged. ECMO blood flow was kept constant while gas flow was increased to maintain stable PaCO2. Measurements and Main Results: At Baseline (without ECMO) and toward the end of each step, data from quantitative CT scan, electrical impedance tomography, and gas exchange were collected. Increasing ECMO gas flow while lowering the respiratory rate was associated with an increase in the fraction of non-aerated tissue (i.e., atelectasis) and with a decrease of tidal ventilation reaching the gravitationally dependent lung regions (p = 0.009 and p = 0.018). Intrapulmonary shunt increased (p < 0.001) and arterial PaO2 decreased (p < 0.001) at lower rates. The fraction of non-aerated lung was correlated with longer expiratory time spent at zero flow (r = 0.555, p = 0.011). Conclusions: Progressive decrease of respiratory rate coupled with increasing CO2 removal in mechanically ventilated healthy pigs is associated with development of lung atelectasis, higher shunt, and poorer oxygenation.

8.
Respir Care ; 64(4): 372-383, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30622174

RESUMO

BACKGROUND: Endotracheal suctioning is mandatory to prevent complications caused by the retention of tracheal secretions. Endotracheal suctioning is often performed late, when patients show signs of respiratory and hemodynamic alterations. We conceived a prototype device that, when synchronized with the ventilator, automatically removes secretions collected below the endotracheal tube (ETT) cuff, thus avoiding endotracheal suctioning. The aim of our investigation was to assess the performance of this novel prototype in vitro. METHODS: Three studies were performed to examine the characteristics of the prototype. We tested device's ability to generate an effective artificial cough flow (artificial cough maneuver) > 1 L/s by rapidly deflating the ETT cuff within the time of a sustained inflation (at 30 and at 40 cm H2O) (cough flow study). We also tested the prototype's ability to remove the fluid positioned below the ETT cuff using saline dye (fluid removal study), and to prevent the aspiration of saline dye from above the ETT cuff during the deflation phase of the ETT cuff (aspiration study). The trachea model was positioned at 45° in the aspiration study, and horizontally in the other two studies. RESULTS: In the cough flow study, the prototype provided an effective artificial cough maneuver, with a mean ± SD of 1.78 ± 0.19 L/s (range, 1.42-2.14 L/s). The tracheal pressure after ETT cuff deflation never decreased below the PEEP level. In the fluid removal study, the prototype cleared the fluid from below the ETT cuff and the experimental trachea. No fluid was aspirated from the area above the ETT cuff toward the lower airways. CONCLUSIONS: We conceived an system capable of automatically expelling fluid from below the ETT cuff outside an experimental trachea by generating an artificial cough maneuver. This system may decrease the use of endotracheal suctioning and its complications. Future in vivo studies are needed to confirm this first in vitro evaluation.


Assuntos
Tosse/fisiopatologia , Intubação Intratraqueal , Sucção , Desenho de Equipamento , Expiração/fisiologia , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Teste de Materiais , Eliminação Pulmonar , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Sucção/instrumentação , Sucção/métodos , Ventiladores Mecânicos
9.
J Clin Med ; 8(11)2019 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-31717387

RESUMO

Ex-situ machine perfusion (MP) has been increasingly used to enhance liver quality in different settings. Small animal models can help to implement this procedure. As most normothermic MP (NMP) models employ sub-physiological levels of oxygen delivery (DO2), the aim of this study was to investigate the effectiveness and safety of different DO2, using human red blood cells (RBCs) as oxygen carriers on metabolic recovery in a rat model of NMP. Four experimental groups (n = 5 each) consisted of (1) native (untreated/control), (2) liver static cold storage (SCS) 30 min without NMP, (3) SCS followed by 120 min of NMP with Dulbecco-Modified-Eagle-Medium as perfusate (DMEM), and (4) similar to group 3, but perfusion fluid was added with human RBCs (hematocrit 15%) (BLOOD). Compared to DMEM, the BLOOD group showed increased liver DO2 (p = 0.008) and oxygen consumption ( V O ˙ 2) (p < 0.001); lactate clearance (p < 0.001), potassium (p < 0.001), and glucose (p = 0.029) uptake were enhanced. ATP levels were likewise higher in BLOOD relative to DMEM (p = 0.031). V O ˙ 2 and DO2 were highly correlated (p < 0.001). Consistently, the main metabolic parameters were directly correlated with DO2 and V O ˙ 2. No human RBC related damage was detected. In conclusion, an optimized DO2 significantly reduces hypoxic damage-related effects occurring during NMP. Human RBCs can be safely used as oxygen carriers.

10.
ALTEX ; 2019 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-31833557

RESUMO

Ex-situ machine perfusion (MP) techniques are increasingly used in clinical settings, especially on grafts derived from donors after cardiac death (DCD). However, comprehension of biological effects elicited during MP are largely unknown and a substantial number of animal studies are presently focused on this topic. The aim of the present study was to describe a model of DCD based on ex-situ perfusion of liver grafts derived from animals dedicated to food production. Procurement took place within a slaughterhouse facility. A clinically fashioned closed circuit normothermic MP (NMP) was built up. Autologous blood-enriched perfusion fluid was adopted. Perfusate and tissue samples were collected to asses NMP functionality. Grafts were classified as transplantable (LT-G) or not (n-LT) according to clinical criteria, while histopathological analysis was used to confirm graft viability. After cold storage, the liver grafts were connected to the NMP. During the rewarming phase, temperature and flows were progressively increased to reach target values. At the end of NMP, 4 grafts were classified as LT-G and 3 nLT-G. Histology confirmed absence of major damage in LT-G, while diffuse necrosis appeared in nLT-G. Interestingly, in nLT-G an early impairment of hepatocyte respiratory chain, leading to cell necrosis and graft non-viability, was documented for the first time. These parameters, together with indocyanine-green dye and citrate clearance could contribute to graft evaluation in clinical settings. In conclusion, this model provides a promising and reproducible method to replace dedicated experimental animals in DCD and MP research, in line with the 3Rs principles.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa