Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 37(1): 119-125, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598861

RESUMO

BACKGROUND: Today, various options are used for the reconstruction of acetabular bone loss in revision total hip arthroplasty (RTHA). The aim of the study was to compare the outcomes of using standard acetabular implants (SAIs) and custom-made acetabular implants (CMAIs) in RTHA in cases with extensive acetabular bone loss. METHODS: This was a comparative analysis of the results of 106 operations of RTHA performed during the period from January 2013 to December 2019. In 61 cases (57.5%), CMAIs were used. In 45 cases (42.5%), SAIs were implanted. RESULTS: The incidence of aseptic loosening of the acetabular component after RTHA in uncontained loss of bone stock of the acetabulum (type III-IV as per the Gross and Saleh classification) using the CMAI was less than that using the SAI (2.4% and 10.0%, respectively). The most significant differences in aseptic loosening rates were noted after implantation of the CMAI and SAI in pelvic discontinuity with uncontained bone defect (0% and 60.0%, respectively; P<.001). CONCLUSION: The ideal indications for the use of the CMAI are uncontained defects and pelvic discontinuity with uncontained loss of bone stock (types III-V Gross and Saleh classification). Treatment of these defects with the SAI leads to a higher incidence of aseptic loosening requiring re-revisions. Further observation is required to assess the effectiveness of using the CMAI and SAI in the long-term follow-up period.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Falha de Prótese , Reoperação , Estudos Retrospectivos
2.
J Orthop ; 48: 6-12, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38059213

RESUMO

Background: The number of hip revisions makes up over 12 % of all hip arthroplasty cases. For large acetabular defects custom-made acetabular component (CMAC) are required. Rates of malposition of CMACs are highly variable. Our study aims to develop a readily available, reliable and easily reproducible method for positioning of the CMAC. We tried to answer the following questions: 1) how often does the postoperative position of the implant corresponds to the planned one; 2) is the use of intrawound navigation improve the precision of acetabular implant position. Methods: This was a single-center observational cohort study and included two groups: the experimental group (use of 3D navigation for implant positioning) and the control group (no navigation use). All the patients were scheduled for acetabular revision surgery with custom-made 3D-printed acetabular components. All surgeries took place between 2016 and 2020. Results: 25 % freehand group, 85 % implants in the navigation group matched accuracy positioning criteria. The relative risk of malposition was significantly higher without the intraoperative navigation, with 5 times greater risk of malpositioning in the freehand group versus the navigation group. Conclusion: Navigation method allows planning of the implant and reamer sizes for optimal bone preparation and preservation. It provides easier implantation of the complex implant with reliable, stable primary fixation in massive bone defects. It reliably decreases malposition rate, allowing for implant placement in a proper position with sufficient bone-implant contact. Further research is needed to determine the relationship between CMAC position accuracy and long-term clinical and radiographic outcomes.

3.
Hip Int ; 32(3): 386-390, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-32703053

RESUMO

INTRODUCTION: Due to a lack of uniform shapes and sizes of bone defects in hip and knee joint pathology, their fixing could benefit from using individually manufactured 3D-printed highly porous titanium implants. The objective of this study was to evaluate the extent of bone and muscle tissue integration into porous titanium implants manufactured using additive technology. MATERIALS AND METHODS: Porous and non-porous titanium plates were implanted into the latissimus dorsi muscle and tibia of 9 rabbits. On days 1, 60 and 90 animals were examined with x-rays. On day 60 histological tests were carried out. On day 90 the tensile strength at the implant-tissue interface was tested. RESULTS: Histological analysis of muscle samples with porous titanium implants showed integration of connective tissue and blood vessels into the pores. Bone defect analysis demonstrated bone ingrowth into the pores of titanium with a minimal amount of fibrous tissue. The tensile strength of the muscular tissue attachment to the porous titanium was 28 (22-30) N which was higher than that of the control group 8.5 (5-11) N. Bone tissue attachment strength was 148 (140-152) N in the experimental group versus 118 (84-122) N in the control group. CONCLUSIONS: Using additive technology in manufacturing 3D-printed highly porous titanium implants improves bone and muscle integration compared with the non-porous material of the control group. This could be a promising approach to bone defect repair in revision and reconstruction surgery.


Assuntos
Artroplastia de Quadril , Titânio , Animais , Humanos , Osseointegração/fisiologia , Porosidade , Próteses e Implantes , Coelhos
4.
Bioengineering (Basel) ; 8(6)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34206126

RESUMO

A technology to create a cell-seeded fibrin-based implant matching the size and shape of bone defect is required to create an anatomical implant. The aim of the study was to develop a technology of cell-seeded fibrin gel implant creation that has the same shape and size as the bone defect at the site of implantation. Using computed tomography (CT) images, molds representing bone defects were created by 3D printing. The form was filled with fibrin glue and human dental pulp stem cells (DPSC). The viability, set of surface markers and osteogenic differentiation of DPSC grown in fibrin gel along with the clot retraction time were evaluated. In mice, an alveolar bone defect was created. The defect was filled with fibrin gel seeded with mouse DPSC. After 28 days, the bone repair was analyzed with cone beam CT and by histological examination. The proliferation rate, set of surface antigens and osteogenic potential of cells grown inside the scaffold and in 2D conditions did not differ. In mice, both cell-free and mouse DPSC-seeded implants increased the bone tissue volume and vascularization. In mice with cell-seeded gel implants, the bone remodeling process was more prominent than in animals with a cell-free implant. The technology of 3D-printed forms for molding implants can be used to prepare implants using components that are not suitable for 3D printing.

5.
World J Orthop ; 8(12): 929-934, 2017 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-29312852

RESUMO

AIM: To measure the sensitivity and specificity of the cup version assessment by using only anteroposterior hip and pelvis views, evaluate the incidence of inadequate cup version in patients with repeated dislocations after total hip arthroplasty (THA). METHODS: Radiographic retrospective analysis of 2 groups of patients, with follow up of 6-60 mo, after undergoing primary THA. First group of 32 patients (20 female, 12 male) with unilateral THA (32 hips) required early revision arthroplasty for reasons of dislocation. The mean age and mode were 59 (from 38 to 83) and 66 ages respectively. The average body mass index (BMI) was 24.2 (from 17.7 to 36.3), mode 23.9. Second group was consisted of 164 patients (101 female, 63 male) without dislocations during the follow-up period (170 hips). Among them 6 patients required bilateral THA. The mean age was 60 (from 38 to 84) and mode 59. BMI was 24.8 (17.2-36.8), mode 25.2. Clinical significance of the cup anteversion sign was estimated with cross tabulation 2 × 2. RESULTS: The value of the χ2 yates was 10.668 (P < 0.01). Sensitivity of SAI (sign of anteversion insufficiency) was 29% (95%CI: 9%-46%), and specificity was 92% (95%CI: 88%-96%). Relative risk of dislocation in patients with SAI was 3.4 (95%CI: 1.8-6.3). CONCLUSION: This method provides the surgeons with the ability to perform a reliable and simple qualitative assessment of the acetabular component version. It can be useful during patient examination with early loosening of the implant, dislocations, and impingement. Additionally, it can provide necessary information during planning of revision surgery, especially when considering question about cup replacement, although final assessment of the cup position should be done with a computed tomography scan.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa