Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 21(Pt 1): 268-72, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24365948

RESUMO

The newly installed BL28XU beamline at SPring-8 is dedicated to in situ structural and electronic analysis of rechargeable batteries. It supports the time range (1 ms to 100 s) and spatial range (1 µm to 1 mm) needed for battery analysis. Electrochemical apparatus for battery charging and discharging are available in experimental hutches and in a preparation room. Battery analysis can be carried out efficiently and effectively using X-ray diffraction, X-ray absorption fine-structure analysis and hard X-ray photoelectron spectroscopy. Here, the design and performance of the beamline are described, and preliminary results are presented.

2.
Radiat Prot Dosimetry ; 126(1-4): 288-93, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17575293

RESUMO

The measurements of high-energy and high dose mixed radiation from high-energy electron accelerator are carried out using a radiation damage monitor. It consists of two Radiation-Sensing Field-Effect Transistors (RADFETs) for total absorbed dose from mainly gamma ray and other charged particles and a Si PIN diode for neutron fluence. This is a part of the demagnetization study of rare earth permanent magnet irradiated by 2.5-GeV electron beam. The sensitivities of damage detectors are measured using 65-MeV quasi-monoenergic neutron, 14-MeV D-T neutron, (252)Cf neutron for Si PIN diode and (60)Co and (137)Cs gamma ray for RADFETs. Measured sensitivities are in acceptable range in the comparison of producer's proposed values. The dose and fluence measurements are carried out for the same target condition, Cu and Ta, as that for the demagnetization study. The 5 x 5 cm(2) cross-sectional and 5.5-cm-thick Pb target is also used for the general comparison with photoneutron yields. All measured dose and fluence are compared with the calculated results using the FLUKA code and agree well each other. The application of this kind of radiation damage monitor to high-level dosimetry at high-energy electron accelerator has been discussed.


Assuntos
Magnetismo/instrumentação , Nêutrons , Aceleradores de Partículas/instrumentação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Synchrotron Radiat ; 5(Pt 3): 465-7, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263547

RESUMO

A local bump feedback system is under construction to correct the orbit distortion caused by the magnetic field errors of a double-array undulator used to generate linear and circular polarization of light for a soft X-ray beamline. The local bump orbit is created by steering coils several turns long and four sets of steering magnets. The kick angle of the long steering coils and the steering magnets is determined according to the motion of the undulator and by detecting the beam position.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa