Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Echocardiography ; 41(4): e15815, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38634182

RESUMO

BACKGROUND: Right ventricular (RV) systolic dysfunction has been identified as a prognostic marker for adverse clinical events in patients presenting with acute pulmonary embolism (PE). However, challenges exist in identifying RV dysfunction using conventional echocardiography techniques. Strain echocardiography is an evolving imaging modality which measures myocardial deformation and can be used as an objective index of RV systolic function. This study evaluated RV Global Longitudinal Strain (RVGLS) in patients with intermediate risk PE as a parameter of RV dysfunction, and compared to traditional echocardiographic and CT parameters evaluating short-term mortality. METHODS: Retrospective single center cohort study of 251 patients with intermediate-risk PE between 2010 and 2018. The primary outcome was all-cause mortality at 30 days. Statistical analysis evaluated each parameter comparing survivors versus non-survivors at 30 days. Receiver operating characteristic (ROC) curves and Kaplan-Meier curves were used for comparison of the two cohorts. RESULTS: Altogether 251 patients were evaluated. Overall mortality rate was 12.4%. Utilizing an ROC curve, an absolute cutoff value of 17.7 for RVGLS demonstrated a sensitivity of 93% and specificity of 70% for observed 30-day mortality. Individuals with an RVGLS ≤17.7 had a 25 times higher mortality rate than those with RVGLS above 17.7 (HR 25.24, 95% CI = 6.0-106.4, p < .001). Area under the curve was (.855), RVGLS outperformed traditional echocardiographic parameters, CT findings, and cardiac biomarkers on univariable and multivariable analysis. CONCLUSIONS: Reduced RVGLS values on initial echocardiographic assessment of patients with intermediate-risk PE identified patients at higher risk for mortality at 30 days.


Assuntos
Embolia Pulmonar , Disfunção Ventricular Direita , Humanos , Deformação Longitudinal Global , Estudos Retrospectivos , Estudos de Coortes , Volume Sistólico , Embolia Pulmonar/complicações , Função Ventricular Direita , Prognóstico
2.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
3.
Circulation ; 143(19): 1852-1862, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33874732

RESUMO

BACKGROUND: Peripartum cardiomyopathy (PPCM) occurs in ≈1:2000 deliveries in the United States and worldwide. The genetic underpinnings of PPCM remain poorly defined. Approximately 10% of women with PPCM harbor truncating variants in TTN (TTNtvs). Whether mutations in other genes can predispose to PPCM is not known. It is also not known if the presence of TTNtvs predicts clinical presentation or outcomes. Nor is it known if the prevalence of TTNtvs differs in women with PPCM and preeclampsia, the strongest risk factor for PPCM. METHODS: Women with PPCM were retrospectively identified from several US and international academic centers, and clinical information and DNA samples were acquired. Next-generation sequencing was performed on 67 genes, including TTN, and evaluated for burden of truncating and missense variants. The impact of TTNtvs on the severity of clinical presentation, and on clinical outcomes, was evaluated. RESULTS: Four hundred sixty-nine women met inclusion criteria. Of the women with PPCM, 10.4% bore TTNtvs (odds ratio=9.4 compared with 1.2% in the reference population; Bonferroni-corrected P [P*]=1.2×10-46). We additionally identified overrepresentation of truncating variants in FLNC (odds ratio=24.8, P*=7.0×10-8), DSP (odds ratio=14.9, P*=1.0×10-8), and BAG3 (odds ratio=53.1, P*=0.02), genes not previously associated with PPCM. This profile is highly similar to that found in nonischemic dilated cardiomyopathy. Women with TTNtvs had lower left ventricular ejection fraction on presentation than did women without TTNtvs (23.5% versus 29%, P=2.5×10-4), but did not differ significantly in timing of presentation after delivery, in prevalence of preeclampsia, or in rates of clinical recovery. CONCLUSIONS: This study provides the first extensive genetic and phenotypic landscape of PPCM and demonstrates that predisposition to heart failure is an important risk factor for PPCM. The work reveals a degree of genetic similarity between PPCM and dilated cardiomyopathy, suggesting that gene-specific therapeutic approaches being developed for dilated cardiomyopathy may also apply to PPCM, and that approaches to genetic testing in PPCM should mirror those taken in dilated cardiomyopathy. Last, the clarification of genotype/phenotype associations has important implications for genetic counseling.


Assuntos
Cardiomiopatias/genética , Período Periparto/genética , Adulto , Cardiomiopatias/fisiopatologia , Feminino , Humanos , Fenótipo , Gravidez , Estudos Retrospectivos
4.
J Card Fail ; 28(5): 756-764, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34775112

RESUMO

BACKGROUND: Although claims data provide a large and efficient source of clinical events, validation is needed prior to use in heart failure (HF) diagnostic development. METHODS AND RESULTS: Data from the Multisensor Chronic Evaluations in Ambulatory Heart Failure Patients (MultiSENSE) study, used to create the HeartLogic HF diagnostic, were linked with fee-for-service (FFS) Medicare claims. Events were matched by patient ID and date, and agreement was calculated between claims primary HF diagnosis codes and study event adjudication. HF events (HFEs) were defined as inpatient visits, or outpatient visits with intravenous decongestive therapy. Diagnostic performance was measured as HFE-detection sensitivity and false-positive rate (FPR). Linkage of 791 MultiSENSE subjects returned 320 FFS patients with an average follow-up duration of 0.94 years. Although study and claims deaths matched exactly (n = 14), matching was imperfect between study hospitalizations and acute inpatient claims events. Of 239 total events, 165 study hospitalizations (69%) matched inpatient claims events, 28 hospitalizations matched outpatient claims events (12%), 14 hospitalizations were study-unique (6%), and 32 inpatient events were claims-unique (13%). Inpatient HF classification had substantial agreement with study adjudication (κ = 0.823). Diagnostic performance was not different between claims and study events (sensitivity = 75.6% vs 77.6% and FPR = 1.539 vs 1.528 alerts/patient-year). HeartLogic-detected events contributed to > 90% of the HFE costs used for evaluation. CONCLUSIONS: Acceptable event matching, good agreement of claims diagnostic codes with adjudication, and equivalent diagnostic performance support the validity of using claims for HF diagnostic development.


Assuntos
Insuficiência Cardíaca , Idoso , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Medicare , Estados Unidos/epidemiologia
5.
J Card Fail ; 28(8): 1245-1254, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35460884

RESUMO

BACKGROUND: Patients with heart failure (HF) and reduced ejection fraction suffer from a relapsing and remitting disease course, where early treatment changes may improve outcomes. We assessed the clinical integration and safety of the HeartLogic multisensor index and alerts in HF care. METHODS: The Multiple cArdiac seNsors for mAnaGEment of Heart Failure (MANAGE-HF) study enrolled 200 patients with HF and reduced ejection fraction (<35%), New York Heart Association functional class II-III symptoms, implanted with a cardiac resynchronization therapy-defibrillator or and implantable cardioverter defibrillator, who had either a hospitalization for HF within 12 months or unscheduled visit for HF exacerbation within 90 days or an elevated natriuretic peptide concentration (brain natriuretic peptide [BNP] of ≥150 pg/mL or N-terminal pro-BNP [NT-proBNP] of ≥600 pg/mL). This phase included the development of an alert management guide and evaluated changes in medical treatment, natriuretic peptide levels, and safety. RESULTS: The mean age of participants was 67 years, 68% were men, 81% were White, and 61% had a HF hospitalization in prior 12 months. During follow-up, there were 585 alert cases with an average of 1.76 alert cases per patient-year. HF medications were augmented during 74% of the alert cases. HF treatment augmentation within 2 weeks from an initial alert was associated with more rapid recovery of the HeartLogic Index. Five serious adverse events (0.015 per patient-year) occurred in relation to alert-prompted medication change. NTproBNP levels decreased from median of 1316 pg/mL at baseline to 743 pg/mL at 12 months (P < .001). CONCLUSIONS: HeartLogic alert management was safely implemented in HF care and may optimize HF management. This phase supports further evaluation in larger studies. TRIAL REGISTRATION: ClinicalTrials.gov (NCT03237858).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Algoritmos , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Masculino , Peptídeo Natriurético Encefálico/uso terapêutico , Fragmentos de Peptídeos , Volume Sistólico
6.
Heart Fail Rev ; 27(4): 1281-1300, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34559368

RESUMO

In heart failure (HF) patients, remote monitoring using implantable devices may be used to predict and reduce HF exacerbations and mortality. Data from randomized controlled trials (RCTs) was assessed to determine the effectiveness of implantable remote monitoring on the improvement of outcomes in HF patients. A systematic review and meta-analysis of RCTs testing remote monitoring versus standard of care for management of HF patients was performed. Primary endpoints were all-cause mortality and a composite of cardiovascular (CV) and HF hospitalizations. Rate ratios (RRs) and 95% confidence intervals (CI) were calculated. A secondary analysis tested for heterogeneity of treatment effect (HTE) comparing right ventricular/pulmonary pressure monitoring versus impedance-based monitoring on hospitalization. A regression analysis was performed using the mean follow-up time as the moderator on each primary endpoint. Eleven RCTs (n = 6196) were identified with a mean follow-up of 21.9 months. The mean age and reported ejection fraction were 64.1 years and 27.7%, respectively. Remote monitoring did not reduce mortality (RR 0.89 [95% CI 0.77, 1.03]) or the composite of CV and HF hospitalizations (RR 0.98 [0.81, 1.19]). Subgroup analysis found significant HTE for hospitalizations between those studies that used right ventricular/pulmonary pressure monitoring versus impedance-based monitoring (I2 = 87.1%, chi2 = 7.75, p = 0.005). Regression analysis found no relationship between the log rate ratio of remote monitoring's effect on mortality, CV hospitalization or HF hospitalization, and mean follow-up time. Compared to standard of care, remote monitoring using implantable devices did not reduce mortality, CV, or HF hospitalizations. However, right ventricular/pulmonary pressure monitoring may reduce HF hospitalizations, which will need to be explored in future studies.


Assuntos
Insuficiência Cardíaca , Tecnologia de Sensoriamento Remoto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Próteses e Implantes , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Sistólico , Função Ventricular Esquerda
7.
Heart Fail Rev ; 27(3): 985-987, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34755260

RESUMO

Our recently published systematic review and meta-analysis of heart failure (HF) remote monitoring using implantable devices (Hajduczok et al. in HF Reviews 1-20, 1) has been updated to reflected new data from the GUIDE-HF trial (Lindenfeld et al. in Lancet 398(10304):991-1001, 2). Data from randomized controlled trials (RCTs) was assessed to determine the effectiveness of implantable remote monitoring on the improvement of outcomes in HF patients. With the inclusion of the data from 1000 patients followed for 12 months in GUIDE-HF, our conclusions remain unchanged: Compared to standard of care, remote monitoring using implantable devices did not reduce mortality, CV, or HF hospitalizations. However, right ventricular/pulmonary pressure monitoring may reduce HF hospitalizations.


Assuntos
Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Monitorização Fisiológica , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Europace ; 23(10): 1586-1595, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34198334

RESUMO

AIMS: The aim of this study is to quantify healthcare resource utilization among non-responders to cardiac resynchronization therapy (CRT-NR) by heart failure (HF) events and influence of comorbidities. METHODS AND RESULTS: The ADVANCE CRT registry (2013-2015) prospectively identified responders/CRT-NRs 6 months post-implant using the clinical composite score. Heart failure event rates and associated cost, both overall and separated for inpatient hospitalizations, office visits, emergency room visits, and observational stays, were quantified. Costs of events were imputed from payments for similar real-world encounters in subjects with CRT-D/P devices in the MarketScan™ commercial and Medicare Supplemental insurance claims databases. Effects of patient demographics and comorbidities on event rates and cost were evaluated. Of 879 US patients (age 69 ± 11 years, 29% female, ischaemic disease 52%), 310 (35%) were CRT-NR. Among CRT-NRs vs. responders, more patients developed HF (41% vs. 11%, P < 0.001), HF event rate was higher (67.0 ± 21.7 vs. 11.4 ± 3.7/100 pt-year, P < 0.001), and HF readmission within 30 days was more common [hazard ratio 7.06, 95% confidence interval (2.1-43.7)]. Inpatient hospitalization was the most common and most expensive event type in CRT-NR. Comorbid HF was increased by diabetes, hypertension, and pulmonary disorders. Over 2 years, compared to CRT responders, each CRT-NR resulted in excess cost of $6388 ($3859-$10 483) to Medicare (P = 0.015) or $10 197 ($6161-$17 394) to private insurances (P = 0.014). CONCLUSION: Healthcare expenditures associated with contemporary CRT non-response management are among the highest for any HF patient group. This illustrates an unmet need for interventions to improve HF outcomes and reduce costs among some CRT recipients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Idoso , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Medicare , Pessoa de Meia-Idade , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
J Card Fail ; 26(2): 151-159, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31634574

RESUMO

BACKGROUND: We compared the relationship between the third heart sound (S3) measured by an implantable cardiac device (devS3) and auscultation (ausS3) and evaluated their prognostic powers for predicting heart failure events (HFEs). METHODS AND RESULTS: In the MultiSENSE study, devS3 was measured daily with continuous values, whereas ausS3 was assessed at study visits with discrete grades. They were compared among patients with and without HFEs at baseline and against each other directly. Cox proportional hazard models were developed between follow-up visits and over the whole study. Simulations were performed on devS3 to match the limitations of auscultation. We studied 900 patients, of whom 106 patients experienced 192 HFEs. Two S3 sensing modalities correlated with each other, but at baseline, only devS3 differentiated patients with or without HFEs (P < 0.0001). The prognostic power of devS3 was superior to that of ausS3 both between follow-up visits (HR = 5.7, P < 0.0001, and 1.7, P = 0.047, respectively) and over the whole study (HR = 2.9, P < 0.0001, and 1.4, P = 0.216, respectively). Simulation results suggested this superiority may be attributed to continuous monitoring and to subaudible measuring capability. CONCLUSIONS: S3 measured by implantable cardiac devices has stronger prognostic power to predict episodes of future HFEs than that of auscultation.


Assuntos
Auscultação/métodos , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial/métodos , Insuficiência Cardíaca/diagnóstico , Internacionalidade , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrocardiografia Ambulatorial/instrumentação , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ruídos Cardíacos/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Valor Preditivo dos Testes
10.
Curr Cardiol Rep ; 22(8): 68, 2020 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-32562085

RESUMO

PURPOSE OF REVIEW: This review will describe the process of remote monitoring in the treatment of heart failure and the clinical trials for different modalities of data collection. RECENT FINDINGS: Small studies monitoring weights, sometimes with other parameters, suggested a significant outcome benefit in meta-analysis. However, this has not been seen in larger studies. Clinical trials of remote monitoring using hemodynamic parameters seems to lead to improved outcomes, with more studies underway. Recently, multi-parameter methods with wearable or implantable devices have shown promise in detecting heart failure. The impact on clinical outcomes is being assessed. When using parameters such as daily weights, remote monitoring for heart failure has not been demonstrated to be broadly beneficial, while remote monitoring of hemodynamic parameters to guide heart failure therapy has met with initial success. Methods of combining multiple physiologic measurements appear to accurately detect worsening heart failure, and clinical trials are underway to assess the impact.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Hemodinâmica , Humanos , Monitorização Fisiológica
11.
N Engl J Med ; 374(3): 233-41, 2016 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-26735901

RESUMO

Background Peripartum cardiomyopathy shares some clinical features with idiopathic dilated cardiomyopathy, a disorder caused by mutations in more than 40 genes, including TTN, which encodes the sarcomere protein titin. Methods In 172 women with peripartum cardiomyopathy, we sequenced 43 genes with variants that have been associated with dilated cardiomyopathy. We compared the prevalence of different variant types (nonsense, frameshift, and splicing) in these women with the prevalence of such variants in persons with dilated cardiomyopathy and with population controls. Results We identified 26 distinct, rare truncating variants in eight genes among women with peripartum cardiomyopathy. The prevalence of truncating variants (26 in 172 [15%]) was significantly higher than that in a reference population of 60,706 persons (4.7%, P=1.3×10(-7)) but was similar to that in a cohort of patients with dilated cardiomyopathy (55 of 332 patients [17%], P=0.81). Two thirds of identified truncating variants were in TTN, as seen in 10% of the patients and in 1.4% of the reference population (P=2.7×10(-10)); almost all TTN variants were located in the titin A-band. Seven of the TTN truncating variants were previously reported in patients with idiopathic dilated cardiomyopathy. In a clinically well-characterized cohort of 83 women with peripartum cardiomyopathy, the presence of TTN truncating variants was significantly correlated with a lower ejection fraction at 1-year follow-up (P=0.005). Conclusions The distribution of truncating variants in a large series of women with peripartum cardiomyopathy was remarkably similar to that found in patients with idiopathic dilated cardiomyopathy. TTN truncating variants were the most prevalent genetic predisposition in each disorder.


Assuntos
Cardiomiopatias/genética , Cardiomiopatia Dilatada/genética , Conectina/genética , Predisposição Genética para Doença , Mutação , Período Periparto , Complicações Cardiovasculares na Gravidez/genética , Adulto , Estudos de Casos e Controles , Conectina/química , Feminino , Humanos , Gravidez , Isoformas de Proteínas , Análise de Sequência de DNA , Volume Sistólico
13.
J Card Fail ; 24(1): 33-42, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29079307

RESUMO

OBJECTIVE: The aim of this work was to evaluate the hypothesis that the distribution of circulating immune cell subsets, or their activation state, is significantly different between peripartum cardiomyopathy (PPCM) and healthy postpartum (HP) women. BACKGROUND: PPCM is a major cause of maternal morbidity and mortality, and an immune-mediated etiology has been hypothesized. Cellular immunity, altered in pregnancy and the peripartum period, has been proposed to play a role in PPCM pathogenesis. METHODS: The Investigation of Pregnancy-Associated Cardiomyopathy (IPAC) study enrolled 100 women presenting with a left ventricular ejection fraction of <0.45 within 2 months of delivery. Peripheral T-cell subsets, natural killer (NK) cells, and cellular activation markers were assessed by flow cytometry in PPCM women early (<6 wk), 2 months, and 6 months postpartum and compared with those of HP women and women with non-pregnancy-associated recent-onset cardiomyopathy (ROCM). RESULTS: Entry NK cell levels (CD3-CD56+CD16+; reported as % of CD3- cells) were significantly (P < .0003) reduced in PPCM (6.6 ± 4.9% of CD3- cells) compared to HP (11.9 ± 5%). Of T-cell subtypes, CD3+CD4-CD8-CD38+ cells differed significantly (P < .004) between PPCM (24.5 ± 12.5% of CD3+CD4-CD8- cells) and HP (12.5 ± 6.4%). PPCM patients demonstrated a rapid recovery of NK and CD3+CD4-CD8-CD38+ cell levels. However, black women had a delayed recovery of NK cells. A similar reduction of NK cells was observed in women with ROCM. CONCLUSIONS: Compared with HP control women, early postpartum PPCM women show significantly reduced NK cells, and higher CD3+CD4-CD8-CD38+ cells, which both normalize over time postpartum. The mechanistic role of NK cells and "double negative" (CD4-CD8-) T regulatory cells in PPCM requires further investigation.


Assuntos
Cardiomiopatias/sangue , Células Matadoras Naturais/patologia , Monócitos/patologia , Período Periparto , Complicações Cardiovasculares na Gravidez , Transtornos Puerperais/sangue , Subpopulações de Linfócitos T/patologia , Adulto , Cardiomiopatias/diagnóstico , Cardiomiopatias/imunologia , Feminino , Citometria de Fluxo , Humanos , Imunidade Celular , Células Matadoras Naturais/imunologia , Monócitos/imunologia , Gravidez , Transtornos Puerperais/diagnóstico , Transtornos Puerperais/imunologia , Subpopulações de Linfócitos T/imunologia , Função Ventricular Esquerda
14.
Am J Physiol Regul Integr Comp Physiol ; 312(6): R873-R882, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28330967

RESUMO

Heat stress evokes significant increases in muscle sympathetic nerve activity (MSNA) in healthy individuals. The MSNA response to heat stress in chronic heart failure (CHF) is unknown. We hypothesized that the MSNA response to heat stress is attenuated in CHF. Passive whole body heating was applied with water-perfused suits in 13 patients (61 ± 2 yr) with stable class II-III CHF, 12 age-matched (62 ± 2 yr) healthy subjects, and 14 young (24 ± 1 yr) healthy subjects. Mild heating (i.e., increases in skin temperature ΔTsk ~2-4°C, internal temperature ΔTcore <0.3°C) significantly decreased MSNA in CHF patients; however, it did not significantly alter the MSNA in the age-matched and young healthy subjects. Heat stress (i.e., ΔTsk ~4°C and ΔTcore ~0.6°C) raised MSNA in the age-matched (32.9 ± 3.2 to 45.6 ± 4.2 bursts/min; P < 0.001) and young (14.3 ± 1.7 to 26.3 ± 2.4 bursts/min; P < 0.001) controls, but not in CHF (46.2 ± 5.3 to 50.5 ± 5.3 bursts/min; P = 0.06). The MSNA increase by the heat stress in CHF (Δ4.2 ± 2.0 bursts/min) was significantly less than those seen in the age-matched (Δ12.8 ± 1.7 bursts/min, P < 0.05) and young (Δ12.0 ± 2.7 bursts/min, P < 0.05) control groups. These data suggest that the MSNA response to heat stress is attenuated in CHF patients. We speculate that the attenuated MSNA response to heat stress may contribute to impaired cardiovascular adjustments in CHF in a hot environment.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Transtornos de Estresse por Calor/fisiopatologia , Músculo Esquelético/inervação , Nervo Fibular/fisiopatologia , Sistema Nervoso Simpático/fisiopatologia , Potenciais de Ação , Adulto , Fatores Etários , Barorreflexo , Regulação da Temperatura Corporal , Estudos de Casos e Controles , Doença Crônica , Insuficiência Cardíaca/diagnóstico , Transtornos de Estresse por Calor/diagnóstico , Humanos , Hipertermia Induzida , Masculino , Pessoa de Meia-Idade , Temperatura Cutânea , Fatores de Tempo , Adulto Jovem
15.
Geriatr Nurs ; 38(6): 537-541, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28554497

RESUMO

The goals of gerontechnology are to develop technology that facilitates goal attainment and improves satisfaction with life for older adults. Few mHealth technology systems have been evaluated using these criteria. The purpose of this paper was to present the qualitative analysis of participant post-intervention interviews from the tablet-delivered Penn State Heart Assistant intervention. Semi-structured interviews (n = 12) were conducted after the completion of a 30 day study protocol. Interviews were transcribed verbatim by a professional transcriptionist, then analyzed using an iterative process of coding, categorization, and thematic development using DeDoose software and a gerontechnology interpretive lens. Two themes with six subthemes arose: Benefits - information sharing with others, usability and learnability, use of help resources; Suggestions - continuing use after the study, technical problems, participant suggested improvements. Interviews suggested improved goal attainment and satisfaction with life for the older adults with use of the tablet.


Assuntos
Insuficiência Cardíaca/terapia , Internet , Autocuidado , Comprimidos , Telemedicina , Idoso , Feminino , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Informática Médica , Inquéritos e Questionários
16.
Heart Fail Clin ; 11(2): 191-201, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25834969

RESUMO

"Implantable devices are well suited to monitor and record several parameters that carry prognostic information. Specifically, the primary function of implantable cardioverter defibrillators (ICDs) is to monitor for changes in heart rhythm and treat both tachyarrhythmias and bradyarrhythmias. They are efficient in monitoring the heart rate, incidence of arrhythmias, and patient activity level, which provide prognostic information. Parameters such as thoracic impedance, heart sounds, and respiratory rate and patterns may further refine prognostic information available from ICDs. Combining parameters may provide a better way to interpret and use the available information."


Assuntos
Arritmias Cardíacas , Insuficiência Cardíaca , Tecnologia de Sensoriamento Remoto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Monitorização Ambulatorial da Pressão Arterial , Cardiografia de Impedância/instrumentação , Cardiografia de Impedância/métodos , Desfibriladores Implantáveis , Progressão da Doença , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Prognóstico , Tecnologia de Sensoriamento Remoto/instrumentação , Tecnologia de Sensoriamento Remoto/métodos , Medição de Risco , Prevenção Secundária
17.
Eur J Heart Fail ; 26(4): 1078-1089, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38561314

RESUMO

AIMS: Heart failure (HF) outcomes remain poor despite optimal guideline-directed medical therapy (GDMT). We assessed safety, effectiveness, and transthoracic echocardiographic (TTE) outcomes during the 12 months after Ventura shunt implantation in the RELIEVE-HF open-label roll-in cohort. METHODS AND RESULTS: Eligibility required symptomatic HF despite optimal GDMT with ≥1 HF hospitalization in the prior year or elevated natriuretic peptides. The safety endpoint was device-related major adverse cardiovascular or neurological events at 30 days, compared to a prespecified performance goal. Effectiveness evaluations included the Kansas City Cardiomyopathy Questionnaire (KCCQ) at baseline, 1, 3, 6, and 12 months and TTE at baseline and 12 months. Overall, 97 patients were enrolled and implanted at 64 sites. Average age was 70 ± 11 years, 97% were in New York Heart Association class III, and half had left ventricular ejection fraction (LVEF) ≤40%. The safety endpoint was achieved (event rate 0%, p < 0.001). KCCQ overall summary score was improved by 12-16 points at all follow-up timepoints (all p < 0.004), with similar outcomes in patients with reduced and preserved LVEF. At 12 months, left ventricular end-systolic and end-diastolic volumes were reduced (p = 0.020 and p = 0.038, respectively), LVEF improved (p = 0.009), right ventricular end-systolic and end-diastolic areas were reduced (p = 0.001 and p = 0.030, respectively), and right ventricular fractional area change (p < 0.001) and tricuspid annular plane systolic excursion (p < 0.001) improved. CONCLUSION: Interatrial shunting with the Ventura device was safe and resulted in favourable clinical effects in patients with HF, regardless of LVEF. Improvements of left and right ventricular structure and function were consistent with reverse myocardial remodelling. These results would support the potential of this shunt device as a treatment for HF.


Assuntos
Ecocardiografia , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Idoso , Volume Sistólico/fisiologia , Ecocardiografia/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade
18.
ESC Heart Fail ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38773938

RESUMO

AIMS: Interatrial shunts are under evaluation as a treatment for heart failure (HF); however, their in vivo flow performance has not been quantitatively studied. We aimed to investigate the fluid dynamics properties of the 0.51 cm orifice diameter Ventura shunt and assess its lumen integrity with serial transesophageal echocardiography (TEE). METHODS AND RESULTS: Computational fluid dynamics (CFD) and bench flow tests were used to establish the flow-pressure relationship of the shunt. Open-label patients from the RELIEVE-HF trial underwent TEE at shunt implant and at 6 and 12 month follow-up. Shunt effective diameter (Deff) was derived from the vena contracta, and flow was determined by the continuity equation. CFD and bench studies independently validated that the shunt's discharge coefficient was 0.88 to 0.89. The device was successfully implanted in all 97 enrolled patients; mean age was 70 ± 11 years, 97% were NYHA class III, and 51% had LVEF ≤40%. Patency was confirmed in all instances, except for one stenotic shunt at 6 months. Deff remained unchanged from baseline at 12 months (0.47 ± 0.01 cm, P = 0.376), as did the trans-shunt mean pressure gradient (5.1 ± 3.9 mmHg, P = 0.316) and flow (1137 ± 463 mL/min, P = 0.384). TEE measured flow versus pressure closely correlated (R2 ≥ 0.98) with a fluid dynamics model. At 12 months, the pulmonary/systemic flow Qp/Qs ratio was 1.22 ± 0.12. CONCLUSIONS: When implanted in patients with advanced HF, this small interatrial shunt demonstrated predictable and durable patency and performance.

19.
J Am Coll Cardiol ; 81(23): 2272-2291, 2023 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-37286258

RESUMO

Early telemonitoring of weights and symptoms did not decrease heart failure hospitalizations but helped identify steps toward effective monitoring programs. A signal that is accurate and actionable with response kinetics for early re-assessment is required for the treatment of patients at high risk, while signal specifications differ for surveillance of low-risk patients. Tracking of congestion with cardiac filling pressures or lung water content has shown most impact to decrease hospitalizations, while multiparameter scores from implanted rhythm devices have identified patients at increased risk. Algorithms require better personalization of signal thresholds and interventions. The COVID-19 epidemic accelerated transition to remote care away from clinics, preparing for new digital health care platforms to accommodate multiple technologies and empower patients. Addressing inequities will require bridging the digital divide and the deep gap in access to HF care teams, who will not be replaced by technology but by care teams who can embrace it.


Assuntos
COVID-19 , Insuficiência Cardíaca , Humanos , Hospitalização , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
20.
ESC Heart Fail ; 10(6): 3690-3699, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37740424

RESUMO

AIMS: The HeartLogic multisensor index has been found to be a sensitive predictor of worsening heart failure (HF). However, there is limited data on this index's association and its constituent sensors with HF readmissions. METHODS AND RESULTS: The PREEMPT-HF study is a global, multicentre, prospective, observational, single-arm, post-market study. HF patients with an implantable defibrillator device or cardiac resynchronization therapy with defibrillator with HeartLogic capabilities were eligible if sensor data collection was turned on and the HeartLogic feature was not enabled. Thus, the HeartLogic Index/alert and heart sounds sensor trends were unavailable via the LATITUDE remote monitoring system to clinicians (blinded). Evaluation of subject medical records at 6 months and a final in-clinic visit at 12 months was required for collection of all-cause hospitalizations and HF outpatient visits. The purpose of this study is exploratory, no formal hypothesis tests are planned, and no adjustment for multiple testing will be performed. A total of 2183 patients were enrolled at 103 sites between June 2018 and June 2020. A significant proportion of the patients were implanted with implantable defibrillator devices (39%) versus cardiac resynchronization therapy with defibrillator (61%); were female (27%); over 65 (61%); New York Heart Association class I (13%), II (53%), and III (33%); ejection fraction < 25% (21%); ischaemic (50%); and with a history of renal dysfunction (23%). CONCLUSIONS: The PREEMPT study will provide clinical data and blinded sensor trends for the characterization of sensor changes with HF readmission, tachyarrhythmias, and event subgroups. These data may help to refine the clinical use of HeartLogic and to improve patient outcomes.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa