Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
BJU Int ; 126(3): 367-372, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32333714

RESUMO

OBJECTIVE: To evaluate the long-term bowel-associated quality of life (QOL) in men after radiotherapy (RT) for prostate cancer with and without the use of rectal hydrogel spacer. PATIENTS AND METHODS: The patients' QOL was examined using the Expanded Prostate Cancer Index Composite (EPIC) and mean changes from baseline in EPIC domains were evaluated. A total of 215 patients from a randomised multi-institutional trial of RT, with or without hydrogel spacer, with a QOL endpoint were pooled with 165 non-randomised patients from a single institution with prospective QOL collection in patients with or without hydrogel spacer. The proportions of men with minimally important differences (MIDs) relative to pre-treatment baseline in the bowel domain were tested using repeated measure logistic models with a pre-specified threshold for clinically significant declines (≥5 equivalent to MIDx1 and ≥10 equivalent to MIDx2). RESULTS: A total of 380 men were evaluated (64% with spacer and 36% without) with QOL data being available for 199 men with >24 months of follow-up [median (range) 39.5 (31-71.4) months]. Treatment with spacer was associated with less decline in average long-term bowel QOL (89.4 for control and 94.7 for spacer) with differences at >24 months meeting the threshold of a MID difference between cohorts (bowel score difference from baseline: control = -5.1, spacer = 0.3, difference = -5.4; P < 0.001). When evaluated over time men without spacer were more likely to have MIDx1 (5 points) declines in bowel QOL (P = 0.01). At long-term follow-up MIDx1 was 36% without spacer vs 14% with spacer (P <0.001; odds ratio [OR] 3.5, 95% CI 1.7-6.9) while MIDx2 was seen in 19% vs 6% (P = 0.008; OR 3.6, 95% CI 1.4-9.1). The use of spacer was associated with less urgency with bowel movements (P = 0.002) and fewer loose stools (P = 0.009), as well as less bother with urgency (P = 0.007) and frequency of bowel movements (P = 0.009). CONCLUSIONS: In this pooled analysis of QOL after prostate RT with up to 5 years of follow-up, use of a rectal spacer was associated with preservation of bowel QOL. This QOL benefit was preserved with long-term follow-up.


Assuntos
Hidrogéis , Neoplasias da Próstata/radioterapia , Qualidade de Vida , Idoso , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radioterapia/métodos , Reto , Método Simples-Cego , Fatores de Tempo
2.
J Neurooncol ; 143(1): 157-166, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30888558

RESUMO

INTRODUCTION: NRG protocols for glioblastoma allow for clinical target volume (CTV) reductions at natural barriers; however, literature examining CTV contouring and the relevant white matter pathways is lacking. This study proposes consensus CTV guidelines, with a focus on areas of controversy while highlighting common errors in glioblastoma target delineation. METHODS: Ten academic radiation oncologists specializing in brain tumor treatment contoured CTVs on four glioblastoma cases. CTV expansions were based on NRG trial guidelines. Contour consensus was assessed and summarized by kappa statistics. A meeting was held to discuss the mathematically averaged contours and form consensus contours and recommendations. RESULTS: Contours of the cavity plus enhancement (mean kappa 0.69) and T2-FLAIR signal (mean kappa 0.74) showed moderate to substantial agreement. Experts were asked to trim off anatomic barriers while respecting pathways of spread to develop their CTVs. Submitted CTV_4600 (mean kappa 0.80) and CTV_6000 (mean kappa 0.81) contours showed substantial to near perfect agreement. Simultaneous truth and performance level estimation (STAPLE) contours were then reviewed and modified by group consensus. Anatomic trimming reduced the amount of total brain tissue planned for radiation targeting by a 13.6% (range 8.7-17.9%) mean proportional reduction. Areas for close scrutiny of target delineation were described, with accompanying recommendations. CONCLUSIONS: Consensus contouring guidelines were established based on expert contours. Careful delineation of anatomic pathways and barriers to spread can spare radiation to uninvolved tissue without compromising target coverage. Further study is necessary to accurately define optimal target volumes beyond isometric expansion techniques for individual patients.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioblastoma/radioterapia , Guias de Prática Clínica como Assunto , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Protocolos Clínicos , Glioblastoma/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
3.
J Digit Imaging ; 31(6): 783-791, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29907888

RESUMO

Reusable, publicly available data is a pillar of open science and rapid advancement of cancer imaging research. Sharing data from completed research studies not only saves research dollars required to collect data, but also helps insure that studies are both replicable and reproducible. The Cancer Imaging Archive (TCIA) is a global shared repository for imaging data related to cancer. Insuring the consistency, scientific utility, and anonymity of data stored in TCIA is of utmost importance. As the rate of submission to TCIA has been increasing, both in volume and complexity of DICOM objects stored, the process of curation of collections has become a bottleneck in acquisition of data. In order to increase the rate of curation of image sets, improve the quality of the curation, and better track the provenance of changes made to submitted DICOM image sets, a custom set of tools was developed, using novel methods for the analysis of DICOM data sets. These tools are written in the programming language perl, use the open-source database PostgreSQL, make use of the perl DICOM routines in the open-source package Posda, and incorporate DICOM diagnostic tools from other open-source packages, such as dicom3tools. These tools are referred to as the "Posda Tools." The Posda Tools are open source and available via git at https://github.com/UAMS-DBMI/PosdaTools . In this paper, we briefly describe the Posda Tools and discuss the novel methods employed by these tools to facilitate rapid analysis of DICOM data, including the following: (1) use a database schema which is more permissive, and differently normalized from traditional DICOM databases; (2) perform integrity checks automatically on a bulk basis; (3) apply revisions to DICOM datasets on an bulk basis, either through a web-based interface or via command line executable perl scripts; (4) all such edits are tracked in a revision tracker and may be rolled back; (5) a UI is provided to inspect the results of such edits, to verify that they are what was intended; (6) identification of DICOM Studies, Series, and SOP instances using "nicknames" which are persistent and have well-defined scope to make expression of reported DICOM errors easier to manage; and (7) rapidly identify potential duplicate DICOM datasets by pixel data is provided; this can be used, e.g., to identify submission subjects which may relate to the same individual, without identifying the individual.


Assuntos
Conjuntos de Dados como Assunto , Diagnóstico por Imagem , Neoplasias/diagnóstico por imagem , Sistemas de Informação em Radiologia , Fluxo de Trabalho , Humanos
4.
Cancer ; 121(14): 2422-30, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25847819

RESUMO

BACKGROUND: The authors analyzed a preliminary report of patient-reported outcomes (PROs) among men who received high-dose radiation therapy (RT) on Radiation Therapy Oncology Group study 0126 (a phase 3 dose-escalation trial) with either 3-dimensional conformal RT (3D-CRT) or intensity-modulated RT (IMRT). METHODS: Patients in the 3D-CRT group received 55.8 gray (Gy) to the prostate and proximal seminal vesicles and were allowed an optional field reduction; then, they received 23.4 Gy to the prostate only. Patients in the IMRT group received 79.2 Gy to the prostate and proximal seminal vesicles. PROs were assessed at 0 months (baseline), 3 months, 6 months, 12 months, and 24 months and included bladder and bowel function assessed with the Functional Alterations due to Changes in Elimination (FACE) instrument and erectile function assessed with the International Index of Erectile Function (IIEF). Analyses included the patients who completed all data at baseline and for at least 1 follow-up assessment, and the results were compared with an imputed data set. RESULTS: Of 763 patients who were randomized to the 79.2-Gy arm, 551 patients and 595 patients who responded to the FACE instrument and 505 patients and 577 patients who responded to the IIEF were included in the completed and imputed analyses, respectively. There were no significant differences between modalities for any of the FACE or IIEF subscale scores or total scores at any time point for either the completed data set or the imputed data set. CONCLUSIONS: Despite significant reductions in dose and volume to normal structures using IMRT, this robust analysis of 3D-CRT and IMRT demonstrated no difference in patient-reported bowel, bladder, or sexual functions for similar doses delivered to the prostate and proximal seminal vesicles with IMRT compared with 3D-CRT delivered either to the prostate and proximal seminal vesicles or to the prostate alone.


Assuntos
Neoplasias da Próstata/radioterapia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Idoso , Idoso de 80 Anos ou mais , Disfunção Erétil/etiologia , Humanos , Imageamento Tridimensional , Incidência , Intestinos/fisiopatologia , Intestinos/efeitos da radiação , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Ereção Peniana/efeitos da radiação , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Resultado do Tratamento , Bexiga Urinária/fisiopatologia , Bexiga Urinária/efeitos da radiação , Transtornos Urinários/etiologia
5.
Cancer ; 121(13): 2156-63, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25847373

RESUMO

BACKGROUND: The current study was conducted to assess acute and late adverse events (AEs), overall survival (OS), pelvic failure, regional failure, distant failure, and disease-free survival in a prospective phase 2 clinical trial of bevacizumab and pelvic intensity-modulated radiotherapy (IMRT) with chemotherapy in patients with high-risk endometrial cancer. METHODS: Patients underwent a hysterectomy and lymph node removal, and had ≥1 of the following high-risk factors: grade 3 carcinoma with >50% myometrial invasion, grade 2 or 3 disease with any cervical stromal invasion, or known extrauterine extension confined to the pelvis. Treatment included pelvic IMRT and concurrent cisplatin on days 1 and 29 of radiation and bevacizumab (at a dose of 5 mg/kg on days 1, 15, and 29 of radiation) followed by adjuvant carboplatin and paclitaxel for 4 cycles. The primary endpoint was grade ≥3 AEs occurring within the first 90 days (toxicity was graded according to the National Cancer Institute Common Terminology Criteria for Adverse Events [version 4.0]). RESULTS: A total of 34 patients were accrued from November 2009 through December 2011, 30 of whom were eligible and received study treatment. Seven of 30 patients (23.3%; 1-sided 95% confidence interval, 10.6%-36.0%) developed grade ≥3 treatment-related nonhematologic toxicities within 90 days; an additional 6 patients experienced grade ≥3 toxicities between 90 and 365 days after treatment. The 2-year OS rate was 96.7% and the disease-free survival rate was 79.1%. No patient developed a within-field pelvic failure and no patients with International Federation of Gynecology and Obstetrics stage I to IIIA disease developed disease recurrence after a median follow-up of 26 months. CONCLUSIONS: Postoperative bevacizumab added to chemotherapy and pelvic IMRT appears to be well tolerated and results in high OS rates at 2 years for patients with high-risk endometrial carcinoma.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias do Endométrio/tratamento farmacológico , Neoplasias do Endométrio/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Bevacizumab/administração & dosagem , Quimiorradioterapia Adjuvante , Cisplatino/administração & dosagem , Intervalo Livre de Doença , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/cirurgia , Feminino , Humanos , Histerectomia , Excisão de Linfonodo , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Período Pós-Operatório , Radioterapia de Intensidade Modulada
6.
Ann Surg Oncol ; 22(9): 2846-52, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26018727

RESUMO

PURPOSE: Curative intent management of retroperitoneal sarcoma (RPS) requires gross total resection. Preoperative radiotherapy (RT) often is used as an adjuvant to surgery, but recurrence rates remain high. To enhance RT efficacy with acceptable tolerance, there is interest in delivering "boost doses" of RT to high-risk areas of gross tumor volume (HR GTV) judged to be at risk for positive resection margins. We sought to evaluate variability in HR GTV boost target volume delineation among collaborating sarcoma radiation and surgical oncologist teams. METHODS: Radiation planning CT scans for three cases of RPS were distributed to seven paired radiation and surgical oncologist teams at six institutions. Teams contoured HR GTV boost volumes for each case. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. RESULTS: HRGTV boost volume contour agreement between the seven teams was "substantial" or "moderate" for all cases. Agreement was best on the torso wall posteriorly (abutting posterior chest abdominal wall) and medially (abutting ipsilateral para-vertebral space and great vessels). Contours varied more significantly abutting visceral organs due to differing surgical opinions regarding planned partial organ resection. CONCLUSIONS: Agreement of RPS HRGTV boost volumes between sarcoma radiation and surgical oncologist teams was substantial to moderate. Differences were most striking in regions abutting visceral organs, highlighting the importance of collaboration between the radiation and surgical oncologist for "individualized" target delineation on the basis of areas deemed at risk and planned resection.


Assuntos
Órgãos em Risco , Guias de Prática Clínica como Assunto , Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Retroperitoneais/diagnóstico por imagem , Sarcoma/diagnóstico por imagem , Carga Tumoral , Algoritmos , Consenso , Humanos , Variações Dependentes do Observador , Prognóstico , Neoplasias Retroperitoneais/patologia , Neoplasias Retroperitoneais/radioterapia , Fatores de Risco , Sarcoma/patologia , Sarcoma/radioterapia , Tomografia Computadorizada por Raios X/métodos
7.
Pract Radiat Oncol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636586

RESUMO

Although standardization has been shown to improve patient safety and improve the efficiency of workflows, implementation of standards can take considerable effort and requires the engagement of all clinical stakeholders. Engaging team members includes increasing awareness of the proposed benefit of the standard, a clear implementation plan, monitoring for improvements, and open communication to support successful implementation. The benefits of standardization often focus on large institutions to improve research endeavors, yet all clinics can benefit from standardization to increase quality and implement more efficient or automated workflow. The benefits of nomenclature standardization for all team members and institution sizes, including success stories, are discussed with practical implementation guides to facilitate the adoption of standardized nomenclature in radiation oncology.

8.
JAMA Oncol ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935373

RESUMO

Importance: The optimal radiotherapy technique for unresectable locally advanced non-small cell lung cancer (NSCLC) is controversial, so evaluating long-term prospective outcomes of intensity-modulated radiotherapy (IMRT) is important. Objective: To compare long-term prospective outcomes of patients receiving IMRT and 3-dimensional conformal radiotherapy (3D-CRT) with concurrent carboplatin/paclitaxel for locally advanced NSCLC. Design, Setting, and Participants: A secondary analysis of a prospective phase 3 randomized clinical trial NRG Oncology-RTOG 0617 assessed 483 patients receiving chemoradiotherapy (3D-CRT vs IMRT) for locally advanced NSCLC based on stratification. Main Outcomes and Measures: Long-term outcomes were analyzed, including overall survival (OS), progression-free survival (PFS), time to local failure, development of second cancers, and severe grade 3 or higher adverse events (AEs) per Common Terminology Criteria for Adverse Events, version 3. The percentage of an organ volume (V) receiving a specified amount of radiation in units of Gy is reported as V(radiation dose). Results: Of 483 patients (median [IQR] age, 64 [57-70] years; 194 [40.2%] female), 228 (47.2%) received IMRT, and 255 (52.8%) received 3D-CRT (median [IQR] follow-up, 5.2 [4.8-6.0] years). IMRT was associated with a 2-fold reduction in grade 3 or higher pneumonitis AEs compared with 3D-CRT (8 [3.5%] vs 21 [8.2%]; P = .03). On univariate analysis, heart V20, V40, and V60 were associated with worse OS (hazard ratios, 1.06 [95% CI, 1.04-1.09]; 1.09 [95% CI, 1.05-1.13]; 1.16 [95% CI, 1.09-1.24], respectively; all P < .001). IMRT significantly reduced heart V40 compared to 3D-CRT (16.5% vs 20.5%; P < .001). Heart V40 (<20%) had better OS than V40 (≥20%) (median [IQR], 2.5 [2.1-3.1] years vs 1.7 [1.5-2.0] years; P < .001). On multivariable analysis, heart V40 (≥20%), was associated with worse OS (hazard ratio, 1.34 [95% CI, 1.06-1.70]; P = .01), whereas lung V5 and age had no association with OS. Patients receiving IMRT and 3D-CRT had similar rates of developing secondary cancers (15 [6.6%] vs 14 [5.5%]) with long-term follow-up. Conclusions and Relevance: These findings support the standard use of IMRT for locally advanced NSCLC. IMRT should aim to minimize lung V20 and heart V20 to V60, rather than constraining low-dose radiation bath. Lung V5 and age were not associated with survival and should not be considered a contraindication for chemoradiotherapy. Trial Registration: ClinicalTrials.gov Identifier: NCT00533949.

9.
J Appl Clin Med Phys ; 14(4): 4313, 2013 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-23835394

RESUMO

An anthropomorphic head phantom, constructed from a water-equivalent plastic shell with only a spherical target, was modified to include a nonspherical target (pituitary) and an adjacent organ at risk (OAR) (optic chiasm), within 2 mm, simulating the anatomy encountered when treating acromegaly. The target and OAR spatial proximity provided a more realistic treatment planning and dose delivery exercise. A separate dosimetry insert contained two TLD for absolute dosimetry and radiochromic film, in the sagittal and coronal planes, for relative dosimetry. The prescription was 25 Gy to 90% of the GTV, with ≤ 10% of the OAR volume receiving ≥ 8 Gy for the phantom trial. The modified phantom was used to test the rigor of the treatment planning process and phantom reproducibility using a Gamma Knife, CyberKnife, and linear accelerator (linac)-based radiosurgery system. Delivery reproducibility was tested by repeating each irradiation three times. TLD results from three irradiations on a CyberKnife and Gamma Knife agreed with the calculated target dose to within ± 4% with a maximum coefficient of variation of ± 2.1%. Gamma analysis in the coronal and sagittal film planes showed an average passing rate of 99.4% and 99.5% using ± 5%/3 mm criteria, respectively. Results from the linac irradiation were within ± 6.2% for TLD with a coefficient of variation of ± 0.1%. Distance to agreement was calculated to be 1.2 mm and 1.3mm along the inferior and superior edges of the target in the sagittal film plane, and 1.2 mm for both superior and inferior edges in the coronal film plane. A modified, anatomically realistic SRS phantom was developed that provided a realistic clinical planning and delivery challenge that can be used to credential institutions wanting to participate in NCI-funded clinical trials.


Assuntos
Imagens de Fantasmas/normas , Radiocirurgia/normas , Acromegalia/cirurgia , Adenoma/cirurgia , Ensaios Clínicos como Assunto , Cabeça , Humanos , Pescoço , Quiasma Óptico/efeitos da radiação , Órgãos em Risco , Neoplasias Hipofisárias/cirurgia , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/normas , Reprodutibilidade dos Testes , Dosimetria Termoluminescente
10.
Front Oncol ; 13: 1239104, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37886176

RESUMO

Purpose: The purpose of this study was to analyze the impact of prostate rectal spacers on sexual quality of life (QOL) following external beam radiation therapy (RT). Methods and materials: Patient- reported QOL was evaluated using the Expanded Prostate Cancer Index Composite (EPIC). Patients were pooled from two sources: a randomized controlled trial and a non-randomized cohort of patients from a single institution. Both cohorts used the same spacing product and QOL instrument. Analysis was limited to those with good baseline pre-treatment sexual QOL (EPIC >/= 60). Differences in QOL summary score and individual items were assessed compared with baseline and between treatment arms. Results: A total of 128 men had good baseline sexual function and were evaluated (64% with spacer and 36% without) with QOL data available for median 33 months (range: 2.5-69.4 months). Men without spacer were more likely to have declines in sexual function (p < 0.0001), bother (p = 0.0002), and sexual summary score (p < 0.0001). A minimally important difference of 10 points (1xMID) and 20 point (2xMID) was more likely without rectal spacer [10 points: odds ratio 3.53, (95% confidence interval 1.11-11.2), p = 0.032; 20 points: odds ratio 3.29, (95% confidence interval 1.16-9.33), p = 0.025]. Seven of 13 QOL items were statistically superior with hydrogel (six of nine functional and one of four bother), while no items were statistically superior for control. At baseline, more men treated with hydrogel had erections sufficient for intercourse; however, when analyzed only by the men with best baseline erectile potential and excluding those with worse function, the benefit of rectal spacing was maintained with a higher likelihood of preservation of erections sufficient for intercourse in those treated with hydrogel. Conclusion: In this pooled analysis of QOL after prostate RT, the utilization of a hydrogel spacer was associated with better sexual QOL, less men with measurable declines in sexual QOL, and higher rates of adequate erectile function.

11.
J Clin Oncol ; 41(24): 4035-4044, 2023 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-37315297

RESUMO

PURPOSE: To determine whether addition of external beam radiation therapy (EBRT) to brachytherapy (BT) (COMBO) compared with BT alone would improve 5-year freedom from progression (FFP) in intermediate-risk prostate cancer. METHODS: Men with prostate cancer stage cT1c-T2bN0M0, Gleason Score (GS) 2-6 and prostate-specific antigen (PSA) 10-20 or GS 7, and PSA < 10 were eligible. The COMBO arm was EBRT (45 Gy in 25 fractions) to prostate and seminal vesicles followed by BT prostate boost (110 Gy if 125-Iodine, 100 Gy if 103-Pd). BT arm was delivered to prostate only (145 Gy if 125-Iodine, 125 Gy if 103-Pd). The primary end point was FFP: PSA failure (American Society for Therapeutic Radiology and Oncology [ASTRO] or Phoenix definitions), local failure, distant failure, or death. RESULTS: Five hundred eighty-eight men were randomly assigned; 579 were eligible: 287 and 292 in COMBO and BT arms, respectively. The median age was 67 years; 89.1% had PSA < 10 ng/mL, 89.1% had GS 7, and 66.7% had T1 disease. There were no differences in FFP. The 5-year FFP-ASTRO was 85.6% (95% CI, 81.4 to 89.7) with COMBO compared with 82.7% (95% CI, 78.3 to 87.1) with BT (odds ratio [OR], 0.80; 95% CI, 0.51 to 1.26; Greenwood T P = .18). The 5-year FFP-Phoenix was 88.0% (95% CI, 84.2 to 91.9) with COMBO compared with 85.5% (95% CI, 81.3 to 89.6) with BT (OR, 0.80; 95% CI, 0.49 to 1.30; Greenwood T P = .19). There were no differences in the rates of genitourinary (GU) or GI acute toxicities. The 5-year cumulative incidence for late GU/GI grade 2+ toxicity is 42.8% (95% CI, 37.0 to 48.6) for COMBO compared with 25.8% (95% CI, 20.9 to 31.0) for BT (P < .0001). The 5-year cumulative incidence for late GU/GI grade 3+ toxicity is 8.2% (95% CI, 5.4 to 11.8) compared with 3.8% (95% CI, 2.0 to 6.5; P = .006). CONCLUSION: Compared with BT, COMBO did not improve FFP for prostate cancer but caused greater toxicity. BT alone can be considered as a standard treatment for men with intermediate-risk prostate cancer.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/efeitos adversos , Humanos , Neoplasias da Próstata/radioterapia , Antígeno Prostático Específico , Dosagem Radioterapêutica , Resultado do Tratamento , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
12.
Int J Radiat Oncol Biol Phys ; 116(5): 1202-1217, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37121362

RESUMO

FLASH radiation therapy (FLASH-RT), delivered with ultrahigh dose rate (UHDR), may allow patients to be treated with less normal tissue toxicity for a given tumor dose compared with currently used conventional dose rate. Clinical trials are being carried out and are needed to test whether this improved therapeutic ratio can be achieved clinically. During the clinical trials, quality assurance and credentialing of equipment and participating sites, particularly pertaining to UHDR-specific aspects, will be crucial for the validity of the outcomes of such trials. This report represents an initial framework proposed by the NRG Oncology Center for Innovation in Radiation Oncology FLASH working group on quality assurance of potential UHDR clinical trials and reviews current technology gaps to overcome. An important but separate consideration is the appropriate design of trials to most effectively answer clinical and scientific questions about FLASH. This paper begins with an overview of UHDR RT delivery methods. UHDR beam delivery parameters are then covered, with a focus on electron and proton modalities. The definition and control of safe UHDR beam delivery and current and needed dosimetry technologies are reviewed and discussed. System and site credentialing for large, multi-institution trials are reviewed. Quality assurance is then discussed, and new requirements are presented for treatment system standard analysis, patient positioning, and treatment planning. The tables and figures in this paper are meant to serve as reference points as we move toward FLASH-RT clinical trial performance. Some major questions regarding FLASH-RT are discussed, and next steps in this field are proposed. FLASH-RT has potential but is associated with significant risks and complexities. We need to redefine optimization to focus not only on the dose but also on the dose rate in a manner that is robust and understandable and that can be prescribed, validated, and confirmed in real time. Robust patient safety systems and access to treatment data will be critical as FLASH-RT moves into the clinical trials.


Assuntos
Credenciamento , Elétrons , Humanos , Instalações de Saúde , Posicionamento do Paciente , Tecnologia , Dosagem Radioterapêutica
13.
Int J Radiat Oncol Biol Phys ; 117(3): 533-550, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37244628

RESUMO

PURPOSE: The ongoing lack of data standardization severely undermines the potential for automated learning from the vast amount of information routinely archived in electronic health records (EHRs), radiation oncology information systems, treatment planning systems, and other cancer care and outcomes databases. We sought to create a standardized ontology for clinical data, social determinants of health, and other radiation oncology concepts and interrelationships. METHODS AND MATERIALS: The American Association of Physicists in Medicine's Big Data Science Committee was initiated in July 2019 to explore common ground from the stakeholders' collective experience of issues that typically compromise the formation of large inter- and intra-institutional databases from EHRs. The Big Data Science Committee adopted an iterative, cyclical approach to engaging stakeholders beyond its membership to optimize the integration of diverse perspectives from the community. RESULTS: We developed the Operational Ontology for Oncology (O3), which identified 42 key elements, 359 attributes, 144 value sets, and 155 relationships ranked in relative importance of clinical significance, likelihood of availability in EHRs, and the ability to modify routine clinical processes to permit aggregation. Recommendations are provided for best use and development of the O3 to 4 constituencies: device manufacturers, centers of clinical care, researchers, and professional societies. CONCLUSIONS: O3 is designed to extend and interoperate with existing global infrastructure and data science standards. The implementation of these recommendations will lower the barriers for aggregation of information that could be used to create large, representative, findable, accessible, interoperable, and reusable data sets to support the scientific objectives of grant programs. The construction of comprehensive "real-world" data sets and application of advanced analytical techniques, including artificial intelligence, holds the potential to revolutionize patient management and improve outcomes by leveraging increased access to information derived from larger, more representative data sets.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Humanos , Inteligência Artificial , Consenso , Neoplasias/radioterapia , Informática
14.
Clin Genitourin Cancer ; 20(3): e227-e232, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35153154

RESUMO

BACKGROUND: We evaluated inter-fraction penile bulb (PB) changes in prostate cancer (PCa) patients undergoing MR-guided RT in the post-radical prostatectomy (RP) setting. MATERIALS AND METHODS: 10 patients with PCa status-post RP received MR-guided RT from 2017-2019. Patients received daily setup volumetric MRI scans prior to RT delivery for alignment and target localization. Setup MRI datasets from Fx 1, Fx 19, and Fx 37 were fused for each patient based on soft tissue anatomy. The PB was contoured on each MRI. Data on volume (cc), superior/inferior positional change (cm), and mean dose (Gy) was collected. Differences were assessed by Student's t-test (sig. p<0.05). RESULTS: The mean PB volume change from Fx 1→ 19 was +0.34 ± 0.34 cc (p=0.11) and from Fx 1→ 37 was +0.22 ± 0.28 cc (p=0.31). The mean positional change from Fx 1→ 19 was +0.08±0.26 cm (p=0.37) and from Fx 1→ 37 was +0.05 ±0.25 cm (p=0.57). The mean change in mean PB dose from Fx 1→ 19 was +0.19±4.86 Gy (p=0.98) and from Fx 1→ 37 was -1.51≖7.46 Gy (p=0.88). CONCLUSION: We present the first study evaluating inter-fraction changes to the PB during MR-guided RT. We found no clinically meaningful difference in the volume, positional change, or mean dose during RT in the post-prostatectomy setting, suggesting that PB organ motion may not need to be accounted for in radiation treatment planning.


Assuntos
Disfunção Erétil , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética , Masculino , Pênis , Próstata/diagnóstico por imagem , Próstata/cirurgia , Prostatectomia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Pract Radiat Oncol ; 12(2): e117-e122, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34695615

RESUMO

PURPOSE: The use of prostate fiducial markers and perirectal hydrogel spacers can reduce the acute and late toxic effects associated with prostate radiation therapy. These procedures are usually performed days to weeks before simulation during a separate clinic visit to ensure resolution of procedure-related inflammation. The purpose of this study was to assess whether same-day intraprostatic fiducial marker placement, perirectal hydrogel injection, and computed tomography (CT) and magnetic resonance imaging (MRI) simulation were feasible without adversely affecting hydrogel volume, perirectal spacing, or rectal dose. If feasible, performing these procedures on the same day as simulation would expedite the start of radiation therapy, improve patient convenience, and reduce costs. METHODS AND MATERIALS: Twenty-one patients with clinically localized prostate cancer who were enrolled on a prospective clinical trial (NCT01617161) underwent same-day marker placement, hydrogel injection, and CT and MRI simulation, then underwent T2 MRI verification scans 3 to 4 weeks later. The MRI scans were fused to the CT planning scans by clinical target volumes (CTVs) to generate comparison treatment plans (70 Gy in 28 fractions). Hydrogel volume and symmetry, perirectal spacing, CTV dose, and organ-at-risk dose were evaluated. RESULTS: Verification scans occurred a mean of 24.9 ± 4.6 days after simulation and 9.3 ± 4.9 days after treatment start. Prostate volume did not change between scans (median, 67.3 ± 22.1 cm3 vs 64.1 ± 21.8 cm3; P = .64). The median hydrogel change between simulation and verification was -1.8% ± 4.5% (P = .27). No significant differences in perirectal spacing (midgland: 1.33 ± 0.45 cm vs 1.3 ± 0.7 cm; 1 cm superior: 1.25 ± 0.95 cm vs 1.43 ± 0.91 cm; 1 cm inferior: 1.16 ± 0.28 cm vs 1.41 ± 0.49 cm) were identified. No significant differences in rectal V66 (median 2.3 ± 2.18% vs 2.3 ± 2.28%; P = .99), V35 (median 14.79 ± 7.61 vs 14.67 ± 8.4; P = .73), or D1cc (65.7 ± 9.2 Gy vs 68.2 ± 9.0 Gy; P = .80) were found. All plans met CTV and organ-at-risk constraints. CONCLUSION: Same-day placement of intraprostatic fiducial markers, perirectal hydrogel, and simulation scans was feasible and did not significantly affect hydrogel volume, position, CTV coverage, or rectal dose.


Assuntos
Marcadores Fiduciais , Neoplasias da Próstata , Estudos de Viabilidade , Humanos , Hidrogéis/uso terapêutico , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/efeitos da radiação , Tomografia Computadorizada por Raios X
16.
Int J Radiat Oncol Biol Phys ; 112(1): 169-178, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34419564

RESUMO

PURPOSE: To test effects of positron emission tomography (PET)-based bone marrow-sparing (BMS) image-guided intensity modulated radiation therapy (IG-IMRT) on efficacy and toxicity for patients with locoregionally advanced cervical cancer. METHODS AND MATERIALS: In an international phase II/III trial, patients with stage IB-IVA cervical carcinoma were treated with either PET-based BMS-IG-IMRT (PET-BMS-IMRT group) or standard image-guided IMRT (IMRT group), with concurrent cisplatin (40 mg/m2 weekly), followed by brachytherapy. The phase II component nonrandomly assigned patients to PET-BMS-IMRT or standard IMRT. The phase III trial randomized patients to PET-BMS-IMRT versus IMRT, with a primary endpoint of progression-free survival (PFS) but was closed early for futility. Phase III patients were analyzed separately and in combination with phase II patients, comparing acute hematologic toxicity, cisplatin delivery, PFS, overall survival (OS), and patterns of failure. In a post-hoc exploratory analysis, we investigated the association between pretreatment absolute lymphocyte count (ALC) and OS. RESULTS: In total, 101 patients were enrolled on the phase II/III trial, including 29 enrolled in phase III (PET-BMS-IMRT group: 16; IMRT group: 13) before early closure. Median follow-up was 33 months for phase III patients and 39 months for all patients. PFS and OS at 5 years for all patients were 73.6% (95% confidence interval [CI], 64.9%-84.3%) and 84% (95% CI, 76%-92.9%]), respectively. There were no differences in number of cisplatin cycles, OS, PFS, or patterns of failure between groups for the combined cohort. The incidence of acute grade ≥ 3 neutropenia was significantly lower in the PET-BMS-IMRT group compared with IMRT for randomized patients (19% vs 54%, χ2P = .048) and in the combined cohort (13% vs 35%, χ2P = .01). Patients with pretreatment ALC ≤ 1.5 k/µL had nonsignificantly worse OS on multivariable analysis (HR 2.85; 95% CI, 0.94-8.62; adjusted P = .216), compared with patients with ALC > 1.5 k/µL. There was no difference in posttreatment ALC by treatment group. CONCLUSIONS: PET-BMS-IMRT significantly reduced acute grade ≥3 neutropenia, but not treatment-related lymphopenia, compared with standard IMRT. We found no evidence that PET-BMS-IMRT affected chemotherapy delivery or long-term outcomes, and weak evidence of an association between pretreatment ALC and OS.


Assuntos
Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Medula Óssea/efeitos da radiação , Cisplatino/uso terapêutico , Feminino , Humanos , Tomografia por Emissão de Pósitrons , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Resultado do Tratamento , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/tratamento farmacológico , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia
17.
Int J Radiat Oncol Biol Phys ; 112(1): 83-92, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34919884

RESUMO

PURPOSE: External beam radiation therapy (EBRT) dose escalation has been tested in multiple prospective trials. However, the impact on patient reported outcomes (PROs) associated with higher doses of EBRT remain poorly understood. We sought to assess the differences in PROs between men treated with a dose of 70.2 Gy versus 79.2 Gy of EBRT for prostate cancer. METHODS AND MATERIALS: The phase 3 clinical trial RTOG 0126 randomized 1532 patients with prostate cancer between March 2002 and August 2008 to 79.2 Gy over 44 fractions versus 70.2 Gy over 39 fractions. Eligible patients participated in the PRO data collection. PROs completed included the International Index of Erectile Function Questionnaire (IIEF), Functional Alterations due to Changes in Elimination (FACE), and the Spitzer Quality of Life Index (SQLI). The timepoints for the IIEF were collected pre-entry and at 6, 12, and 24 months. The FACE and SQLI were collected pre-entry and at 3, 6, 12, 18, and 24 months. The impact of EBRT dose to normal structures (penile bulb, rectum, and bladder) on PROs was also examined. Mixed effects models were used to analyze trends across time. RESULTS: In total, 1144 patients completed baseline IIEF forms and of these, 56%, 64%, and 61% completed the IIEF at 6, 12, and 24 months, respectively; 1123 patients completed the FACE score at baseline and 50%, 61%, 73%, 61%, and 65% completed all 15 items for the FACE metric at timepoints of 3, 6, 12, 18, and 24 months, respectively. Erectile dysfunction at 12 months based on the single question was not significantly different between arms (38.1% for the standard dose radiation therapy arm vs 49.7% for the dose escalated radiation therapy arm; P = .051). Treatment arm (70.2 vs 79.2) had no significant impact on any PRO metrics measured across all collected domains. Comprehensive dosimetric analyses are presented and reveal multiple significant differences to regional organs at risk. CONCLUSIONS: Compliance with PRO data collection was lower than anticipated in this phase 3 trial. Examining the available data, dose escalated EBRT did not appear to be associated with any detriment to PROs across numerous prospectively collected domains. These data, notwithstanding limitations, add to our understanding of the implications of EBRT dose escalation in prostate cancer. Furthermore, these results illustrate challenges associated with PRO data collection.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Qualidade de Vida , Dosagem Radioterapêutica
18.
Phys Imaging Radiat Oncol ; 19: 138-144, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34485719

RESUMO

BACKGROUND AND PURPOSE: Quantifying radiation dose to cardiac substructures is important for research on the etiology and prevention of complications following radiotherapy; however, segmentation of substructures is challenging. In this study we demonstrate the application of our atlas-based automatic segmentation method to breast cancer radiotherapy plans for generating radiation doses in support of late effects research. MATERIAL AND METHODS: We applied our segmentation method to contour heart substructures on the computed tomography (CT) images of 70 breast cancer patients who received external photon radiotherapy. Two cardiologists provided manual segmentation of the whole heart (WH), left/right atria, left/right ventricles, and left anterior descending artery (LAD). The automatically contours were compared with manual delineations to evaluate similarity in terms of geometry and dose. RESULTS: The mean Dice similarity coefficient between manual and automatic segmentations was 0.96 for the WH, 0.65 to 0.82 for the atria and ventricles, and 0.06 for the LAD. The mean average surface distance was 1.2 mm for the WH, 3.4 to 4.1 mm for the atria and ventricles, and 6.4 mm for the LAD. We found the dose to the cardiac substructures based on our automatic segmentation agrees with manual segmentation within expected observer variability. For left breast patients, the mean absolute difference in mean dose was 0.1 Gy for the WH, 0.2 to 0.7 Gy for the atria and ventricles, and 1.8 Gy for the LAD. For right breast patients, these values were 0.0 Gy, 0.1 to 0.4 Gy, and 0.4 Gy, respectively. CONCLUSION: Our automatic segmentation method will facilitate the development of radiotherapy prescriptive criteria for mitigating cardiovascular complications.

19.
Int J Radiat Oncol Biol Phys ; 109(2): 413-424, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32905846

RESUMO

PURPOSE: Accurate target definition is critical for the appropriate application of radiation therapy. In 2008, the Radiation Therapy Oncology Group (RTOG) published an international collaborative atlas to define the clinical target volume (CTV) for intensity modulated pelvic radiation therapy in the postoperative treatment of endometrial and cervical cancer. The current project is an updated consensus of CTV definitions, with removal of all references to bony landmarks and inclusion of the para-aortic and inferior obturator nodal regions. METHODS AND MATERIALS: An international consensus guideline working group discussed modifications of the current atlas and areas of controversy. A document was prepared to assist in contouring definitions. A sample case abdominopelvic computed tomographic image was made available, on which experts contoured targets. Targets were analyzed for consistency of delineation using an expectation-maximization algorithm for simultaneous truth and performance level estimation with kappa statistics as a measure of agreement between observers. RESULTS: Sixteen participants provided 13 sets of contours. Participants were asked to provide separate contours of the following areas: vaginal cuff, obturator, internal iliac, external iliac, presacral, common iliac, and para-aortic regions. There was substantial agreement for the common iliac region (sensitivity 0.71, specificity 0.981, kappa 0.64), moderate agreement in the external iliac, para-aortic, internal iliac and vaginal cuff regions (sensitivity 0.66, 0.74, 0.62, 0.59; specificity 0.989, 0.966, 0.986, 0.976; kappa 0.60, 0.58, 0.52, 0.47, respectively), and fair agreement in the presacral and obturator regions (sensitivity 0.55, 0.35; specificity 0.986, 0.988; kappa 0.36, 0.21, respectively). A 95% agreement contour was smoothed and a final contour atlas was produced according to consensus. CONCLUSIONS: Agreement among the participants was most consistent in the common iliac region and least in the presacral and obturator nodal regions. The consensus volumes formed the basis of the updated NRG/RTOG Oncology postoperative atlas. Continued patterns of recurrence research are encouraged to refine these volumes.


Assuntos
Consenso , Neoplasias do Endométrio/radioterapia , Guias de Prática Clínica como Assunto , Radioterapia de Intensidade Modulada , Sociedades Médicas , Neoplasias do Colo do Útero/radioterapia , Documentação , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/cirurgia , Feminino , Humanos , Internacionalidade , Órgãos em Risco/efeitos da radiação , Período Pós-Operatório , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/cirurgia
20.
Int J Radiat Oncol Biol Phys ; 107(4): 827-835, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32311418

RESUMO

PURPOSE: Clinical trials have described variation in radiation therapy plan quality, of which contour delineation is a key component, and linked this to inferior patient outcomes. In response, consensus guidelines have been developed to standardize contour delineation. This investigation assesses trends in contouring guidelines and examines the methodologies used to generate and deliver recommendations. METHODS AND MATERIALS: We conducted a literature search for contouring guidelines published after 1995. Of 11,124 citations, 332 were identified for full-text review to determine inclusion. We abstracted articles for the intent of the consensus process, key elements of the methodology, and mode of information delivery. A Fisher exact test was used to identify elements that differed among the guidelines generated for clinical trials and routine care. RESULTS: Overall, 142 guidelines were included, of which 16 (11%) were developed for a clinical trial. There was an increase in guideline publication over time (0 from 1995-1999 vs 65 from 2015- 2019; P = .03), particularly among recommendations for stereotactic radiation and brachytherapy. The most common disease sites were head and neck (24%), gastrointestinal (12%), and gynecologic (12%). Methods used to develop recommendations included literature review (50%) and image-based methods (45%). Panels included a median of 10 physicians (interquartile range, 7-16); 70% of panels represented multidisciplinary expertise. Guidelines developed for a clinical trial were more likely to include an image-based approach, with quantitative analysis of contours submitted by the panel members and to publish a full set of image-based recommendations (P < .005). CONCLUSIONS: This review highlights an increase in consensus contouring recommendations over time. Guidelines focus on disease sites, such as head and neck, with evidence supporting a correlation between treatment planning and patient outcomes, although variation exists in the approach to the consensus process. Elements that may improve guideline acceptance (ie, image-based consensus contour analysis) and usability (ie, inclusion of a full image set) are more common in guidelines developed for clinical trials.


Assuntos
Consenso , Guias de Prática Clínica como Assunto , Radioterapia (Especialidade) , Humanos , Radioterapia (Especialidade)/tendências , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa