Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Magn Reson Imaging ; 40(4): 996-1001, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24845363

RESUMO

PURPOSE: To implement and evaluate high spatial resolution three-dimensional MR contrast-enhanced angiography (3D-CEMRA) of the thighs using a blood pool contrast agent (BPCA) using the quadrature body coil only in patients with peripheral arterial occlusive disease (PAOD) in cases receiver coils cannot be used at 1.5 Tesla (T). MATERIALS AND METHODS: Nineteen patients (mean age: 68.7 ± 11.2 years; range, 38-83 years) with known PAOD (Fontaine stages; III: 16, IV: 3) prospectively underwent 3D-CEMRA at 1.5T with a noninterpolated voxel size of 0.49 × 0.49 × 0.48 mm(3) . Digital subtraction angiography (DSA) was available for comparison in all patients. Two readers independently evaluated movement artifacts, overall image quality of 3D-CEMRA, and grade of stenosis as compared to DSA. SNR and CNR levels were quantified. RESULTS: The 3D-CEMRA was successfully completed in all patients. Patient movement artifacts that affected stenosis grading occurred in 3/38 thighs. Overall image quality was rated excellent in 15/38, good in 12/38, and diagnostic in 8/38 thighs. Stenosis grading matched with that in DSA in 35/38 thighs. High SNR and CNR were measured in all vessels. CONCLUSION: The 0.125 mm(3) spatial resolution 3D-CEMRA of the thighs with a BPCA is feasible using a quadrature body coil exclusively with excellent image quality despite long acquisition times. J. Magn. Reson. Imaging 2014;40:996-1001. © 2014 Wiley Periodicals, Inc.


Assuntos
Arteriopatias Oclusivas/fisiopatologia , Gadolínio , Aumento da Imagem/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Compostos Organometálicos , Doença Arterial Periférica/fisiopatologia , Coxa da Perna/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/patologia , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coxa da Perna/irrigação sanguínea , Coxa da Perna/patologia
2.
J Vasc Interv Radiol ; 24(5): 698-702, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23622041

RESUMO

PURPOSE: To retrospectively evaluate the safety and effectiveness of the EXOSEAL vascular closure device (VCD) for first or repeated closure after retrograde percutaneous femoral arterial access. MATERIALS AND METHODS: A retrospective analysis of 417 patients (271 men; mean age, 64.1 y±12.8; age range, 22-94 y) who had undergone arterial closure with the EXOSEAL VCD was performed. Procedures with retrograde femoral access and closure with the 5-F, 6-F, or 7-F EXOSEAL VCD according to the manufacturer's instructions were included. The clinical indications included the full procedural portfolio of a radiologic department with a focus on transarterial hepatic procedures. After EXOSEAL VCD closure, patients were restricted to bed rest for 4 hours. RESULTS: From August 2010 to March 2012, a total of 682 EXOSEAL VCDs (5-F, n = 276; 6-F, n = 394; 7-F, n = 12) were used in 659 procedures with a total of 404 repeated closures. The EXOSEAL VCD was used successfully in 676 of 682 procedures (99.1%). Hemostasis was achieved in 651 of 682 procedures (95.5%). No major complications were encountered. There were eight cases (1.17%) of minor complications despite a successful vascular closure procedure, none requiring further therapy. There were no complications in any of the 404 cases of repeated vascular closure. CONCLUSIONS: The results of this study suggest that the EXOSEAL VCD is safe and effective in single and repeated closure of retrograde percutaneous femoral arterial access in interventional radiology cases.


Assuntos
Artéria Femoral/cirurgia , Hemostasia Cirúrgica/instrumentação , Técnicas Hemostáticas/instrumentação , Complicações Pós-Operatórias/epidemiologia , Punções/instrumentação , Radiografia Intervencionista/instrumentação , Dispositivos de Acesso Vascular/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Alemanha/epidemiologia , Hemostasia Cirúrgica/estatística & dados numéricos , Técnicas Hemostáticas/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Punções/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa