RESUMO
The apparent diffusion coefficient (ADC) provides a quantitative measure of water mobility that can be used to probe alterations in tissue microstructure due to disease or treatment. Establishment of the accepted level of variance in ADC measurements for each clinical application is critical for its successful implementation. The Diffusion-Weighted Imaging Biomarker Committee of the Quantitative Imaging Biomarkers Alliance (QIBA) has recently advanced the ADC Profile from the consensus to clinically feasible stage for the brain, liver, prostate, and breast. This profile distills multiple studies on ADC repeatability and describes detailed procedures to achieve stated performance claims on an observed ADC change within acceptable confidence limits. In addition to reviewing the current ADC Profile claims, this report has used recent literature to develop proposed updates for establishing metrology benchmarks for mean lesion ADC change that account for measurement variance. Specifically, changes in mean ADC exceeding 8% for brain lesions, 27% for liver lesions, 27% for prostate lesions, and 15% for breast lesions are claimed to represent true changes with 95% confidence. This report also discusses the development of the ADC Profile, highlighting its various stages, and describes the workflow essential to achieving a standardized implementation of advanced quantitative diffusion-weighted MRI in the clinic. The presented QIBA ADC Profile guidelines should enable successful clinical application of ADC as a quantitative imaging biomarker and ensure reproducible ADC measurements that can be used to confidently evaluate longitudinal changes and treatment response for individual patients.
Assuntos
Imagem de Difusão por Ressonância Magnética , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Masculino , Feminino , Biomarcadores , Reprodutibilidade dos TestesRESUMO
Prostate MRI has traditionally relied on qualitative interpretation. However, quantitative components hold the potential to markedly improve performance. The ADC from DWI is probably the most widely recognized quantitative MRI biomarker and has shown strong discriminatory value for clinically significant prostate cancer (csPCa) as well as for recurrent cancer after treatment. Advanced diffusion techniques, including intravoxel incoherent motion, diffusion kurtosis, diffusion tensor imaging, and specific implementations such as restriction spectrum imaging, purport even better discrimination, but are more technically challenging. The inherent T1 and T2 of tissue also provide diagnostic value, with more advanced techniques deriving luminal water imaging and hybrid-multidimensional MRI. Dynamic contrast-enhanced imaging, primarily using a modified Tofts model, also shows independent discriminatory value. Finally, quantitative size and shape features can be combined with the aforementioned techniques and be further refined using radiomics, texture analysis, and artificial intelligence. Which technique will ultimately find widespread clinical use will depend on validation across a myriad of platforms use-cases.
RESUMO
On behalf of the International Society for Magnetic Resonance in Medicine (ISMRM) Quantitative MR Study Group, this article provides an overview of considerations for the development, validation, qualification, and dissemination of quantitative MR (qMR) methods. This process is framed in terms of two central technical performance properties, i.e., bias and precision. Although qMR is confounded by undesired effects, methods with low bias and high precision can be iteratively developed and validated. For illustration, two distinct qMR methods are discussed throughout the manuscript: quantification of liver proton-density fat fraction, and cardiac T1 . These examples demonstrate the expansion of qMR methods from research centers toward widespread clinical dissemination. The overall goal of this article is to provide trainees, researchers, and clinicians with essential guidelines for the development and validation of qMR methods, as well as an understanding of necessary steps and potential pitfalls for the dissemination of quantitative MR in research and in the clinic.
Assuntos
Imageamento por Ressonância Magnética , Terapia com Prótons , Viés , Espectroscopia de Ressonância Magnética , Prótons , Reprodutibilidade dos TestesRESUMO
BACKGROUND: Uncertainty regarding the reproducibility of the apparent diffusion coefficient (ADC) hampers the use of quantitative diffusion-weighted imaging (DWI) in evaluation of the prostate with magnetic resonance imaging MRI. The quantitative imaging biomarkers alliance (QIBA) profile for quantitative DWI claims a within-subject coefficient of variation (wCV) for prostate lesion ADC of 0.17. Improved understanding of ADC reproducibility would aid the use of quantitative diffusion in prostate MRI evaluation. PURPOSE: Evaluation of the repeatability (same-day) and reproducibility (multi-day) of whole-prostate and focal-lesion ADC assessment in a multi-site setting. STUDY TYPE: Prospective multi-institutional. SUBJECTS: Twenty-nine males, ages 53 to 80 (median 63) years, following diagnosis of prostate cancer, 10 with focal lesions. FIELD STRENGTH/SEQUENCE: 3T, single-shot spin-echo diffusion-weighted echo-planar sequence with four b-values. ASSESSMENT: Sites qualified for the study using an ice-water phantom with known ADC. Readers performed DWI analyses at visit 1 ("V1") and visit 2 ("V2," 2-14 days after V1), where V2 comprised scans before ("V2pre") and after ("V2post") a "coffee-break" interval with subject removal and repositioning. A single reader segmented the whole prostate. Two readers separately placed region-of-interests for focal lesions. STATISTICAL TESTS: Reproducibility and repeatability coefficients for whole prostate and focal lesions derived from median pixel ADC. We estimated the wCV and 95% confidence interval using a variance stabilizing transformation and assessed interreader reliability of focal lesion ADC using the intraclass correlation coefficient (ICC). RESULTS: The ADC biases from b0 -b600 and b0 -b800 phantom scans averaged 1.32% and 1.44%, respectively; mean b-value dependence was 0.188%. Repeatability and reproducibility of whole prostate median pixel ADC both yielded wCVs of 0.033 (N = 29). In 10 subjects with an evaluable focal lesion, the individual reader wCVs were 0.148 and 0.074 (repeatability) and 0.137 and 0.078 (reproducibility). All time points demonstrated good to excellent interreader reliability for focal lesion ADC (ICCV1 = 0.89; ICCV2pre = 0.76; ICCV2post = 0.94). DATA CONCLUSION: This study met the QIBA claim for prostate ADC. Test-retest repeatability and multi-day reproducibility were largely equivalent. Interreader reliability for focal lesion ADC was high across time points. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2 TOC CATEGORY: Pelvis.
Assuntos
Imagem de Difusão por Ressonância Magnética , Próstata , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Pelve , Estudos Prospectivos , Próstata/diagnóstico por imagem , Reprodutibilidade dos TestesRESUMO
PURPOSE: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal-to-noise ratio (SNR), proton-spin relaxation times, image uniformity and proton density. METHODS: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57-element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice-profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR. RESULTS: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. CONCLUSIONS: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.
Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-RuídoRESUMO
Physiological properties of tumors can be measured both in vivo and noninvasively by diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging. Although these techniques have been used for more than two decades to study tumor diffusion, perfusion, and/or permeability, the methods and studies on how to reduce measurement error and bias in the derived imaging metrics is still lacking in the literature. This is of paramount importance because the objective is to translate these quantitative imaging biomarkers (QIBs) into clinical trials, and ultimately in clinical practice. Standardization of the image acquisition using appropriate phantoms is the first step from a technical performance standpoint. The next step is to assess whether the imaging metrics have clinical value and meet the requirements for being a QIB as defined by the Radiological Society of North America's Quantitative Imaging Biomarkers Alliance (QIBA). The goal and mission of QIBA and the National Cancer Institute Quantitative Imaging Network (QIN) initiatives are to provide technical performance standards (QIBA profiles) and QIN tools for producing reliable QIBs for use in the clinical imaging community. Some of QIBA's development of quantitative diffusion-weighted imaging and dynamic contrast-enhanced QIB profiles has been hampered by the lack of literature for repeatability and reproducibility of the derived QIBs. The available research on this topic is scant and is not in sync with improvements or upgrades in MRI technology over the years. This review focuses on the need for QIBs in oncology applications and emphasizes the importance of the assessment of their reproducibility and repeatability. Level of Evidence: 5 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:e101-e121.
Assuntos
Biomarcadores , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Ensaios Clínicos como Assunto , Meios de Contraste , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Oncologia/normas , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Neuroimagem/métodos , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Reprodutibilidade dos TestesRESUMO
LEVEL OF EVIDENCE: 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2019.
Assuntos
Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Antropometria , Mama/diagnóstico por imagem , Tomada de Decisões , Aprendizado Profundo , Desenho de Equipamento , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Medicina de Precisão , Radiologia Intervencionista , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Robótica , SoftwareRESUMO
PURPOSE: To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS: A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and a variable flip angle (VFA) protocol using seven flip angles, as well as site-specific protocols (VFA with different flip angles, variable repetition time, proton density, and Look-Locker inversion recovery). Factors influencing the accuracy (deviation from reference NMR T1 measurements) and repeatability were assessed using general linear mixed models. Interplatform reproducibility was assessed using coefficients of variation. RESULTS: For the common IR-SE protocol, accuracy (median error across platforms = 1.4-5.5%) was influenced predominantly by T1 sample (P < 10-6 ), whereas test-retest repeatability (median error = 0.2-8.3%) was influenced by the scanner (P < 10-6 ). For the common VFA protocol, accuracy (median error = 5.7-32.2%) was influenced by field strength (P = 0.006), whereas repeatability (median error = 0.7-25.8%) was influenced by the scanner (P < 0.0001). Interplatform reproducibility with the common VFA was lower at 3 T than 1.5 T (P = 0.004), and lower than that of the common IR-SE protocol (coefficient of variation 1.5T: VFA/IR-SE = 11.13%/8.21%, P = 0.028; 3 T: VFA/IR-SE = 22.87%/5.46%, P = 0.001). Among the site-specific protocols, Look-Locker inversion recovery and VFA (2-3 flip angles) protocols showed the best accuracy and repeatability (errors < 15%). CONCLUSIONS: The VFA protocols with 2 to 3 flip angles optimized for different applications achieved acceptable balance of extensive spatial coverage, accuracy, and repeatability in T1 quantification (errors < 15%). Further optimization in terms of flip-angle choice for each tissue application, and the use of B1 correction, are needed to improve the robustness of VFA protocols for T1 mapping. Magn Reson Med 79:2564-2575, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Encéfalo/diagnóstico por imagem , Mama/diagnóstico por imagem , Meios de Contraste/química , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Neoplasias/diagnóstico por imagem , Próstata/diagnóstico por imagem , Reprodutibilidade dos TestesRESUMO
The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Algoritmos , Biomarcadores/metabolismo , Calibragem , Meios de Contraste/química , Elasticidade , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Modelos Teóricos , Perfusão , Valores de Referência , Reprodutibilidade dos Testes , Razão Sinal-RuídoRESUMO
OBJECTIVE: Multisite and longitudinal neuroimaging studies are important in uncovering trajectories of recovery and neurodegeneration following traumatic brain injury (TBI) and concussion through the use of diffusion tensor imaging (DTI) and other imaging modalities. This study assessed differences in anisotropic diffusion measurement across four scanners using a human and a novel phantom developed in conjunction with the Chronic Effects of Neurotrauma Consortium. METHOD: Human scans provided measurement within biological tissue, and the novel physical phantom provided measures of anisotropic intra-tubular diffusion to serve as a model for intra-axonal water diffusion. Intra- and inter-scanner measurement variances were compared, and the impact on effect size was calculated. RESULTS: Intra-scanner test-retest reliability estimates for fractional anisotropy (FA) demonstrated relative stability over testing intervals. The human tissue and phantom showed similar FA ranges, high linearity and large within-device effect sizes. However, inter-scanner measures of FA indicated substantial differences, some of which exceeded typical DTI effect sizes in mild TBI. CONCLUSION: The diffusion phantom may be used to better elucidate inter-scanner variability in DTI-based measurement and provides an opportunity to better calibrate results obtained from scanners used in multisite and longitudinal studies. Novel solutions are being evaluated to understand and potentially overcome these differences.
Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Substância Branca/diagnóstico por imagem , Adulto , Anisotropia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-IdadeRESUMO
PURPOSE: We present a breast phantom designed to enable quantitative assessment of measurements of T1 relaxation time, apparent diffusion coefficient (ADC), and other attributes of breast tissue, with long-term support from a national metrology institute. MATERIALS AND METHODS: A breast phantom was created with two independent, interchangeable units for diffusion and T1 /T2 relaxation, each with flexible outer shells. The T1 unit was filled with corn syrup solution and grapeseed oil to mimic the relaxation behavior of fibroglandular and fatty tissues, respectively. The diffusion unit contains plastic tubes filled with aqueous solutions of polyvinylpyrrolidone (PVP) to modulate the ADC. The phantom was imaged at 1.5T and 3.0T using magnetic resonance imaging (MRI) scanners and common breast coils from multiple manufacturers to assess T1 and T2 relaxation time and ADC values. RESULTS: The fibroglandular mimic exhibited target T1 values on 1.5T and 3.0T clinical systems (25-75 percentile range: 1289 to 1400 msec and 1533 to 1845 msec, respectively) across all bore temperatures. PVP solutions mimicked the range of ADC values from malignant tumors to normal breast tissue (40% PVP median: 633 × 10(-6) mm(2) /s to 0% PVP median: 2231 × 10(-6) mm(2) /s) at temperatures of 17-24°C. The interchangeable phantom units allowed both the diffusion and T1 /T2 units to be tested on the left and right sides of the coil to assess any variation. CONCLUSION: This phantom enables T1 and ADC measurements, fits in a variety of clinical breast coils, and can serve as a quality control tool to facilitate the standardization of quantitative measurements for breast MRI. J. Magn. Reson. Imaging 2016;44:610-619.
Assuntos
Materiais Biomiméticos/química , Mama/diagnóstico por imagem , Mama/fisiologia , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Mama/anatomia & histologia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
PURPOSE: Prototype phantoms were designed, constructed, and characterized for the purpose of calibrating ultralow field magnetic resonance imaging (ULF MRI) systems. The phantoms were designed to measure spatial resolution and to quantify sensitivity to systematic variation of proton density and relaxation time, T1 . METHODS: The phantoms were characterized first with conventional magnetic resonance scanners at 1.5 and 3 T, and subsequently with a prototype ULF MRI scanner between 107 and 128 µT . RESULTS: The ULF system demonstrated a 2-mm spatial resolution and, using T1 measurements, distinguished aqueous solutions of MnCl2 differing by 20 µM [Mn(2+) ]. CONCLUSION: The prototype phantoms proved well-matched to ULF MRI applications, and allowed direct comparison of the performance of ULF and clinical systems.
Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Projetos Piloto , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Purpose To describe the design, conduct, and results of the Breast Multiparametric MRI for prediction of neoadjuvant chemotherapy Response (BMMR2) challenge. Materials and Methods The BMMR2 computational challenge opened on May 28, 2021, and closed on December 21, 2021. The goal of the challenge was to identify image-based markers derived from multiparametric breast MRI, including diffusion-weighted imaging (DWI) and dynamic contrast-enhanced (DCE) MRI, along with clinical data for predicting pathologic complete response (pCR) following neoadjuvant treatment. Data included 573 breast MRI studies from 191 women (mean age [±SD], 48.9 years ± 10.56) in the I-SPY 2/American College of Radiology Imaging Network (ACRIN) 6698 trial (ClinicalTrials.gov: NCT01042379). The challenge cohort was split into training (60%) and test (40%) sets, with teams blinded to test set pCR outcomes. Prediction performance was evaluated by area under the receiver operating characteristic curve (AUC) and compared with the benchmark established from the ACRIN 6698 primary analysis. Results Eight teams submitted final predictions. Entries from three teams had point estimators of AUC that were higher than the benchmark performance (AUC, 0.782 [95% CI: 0.670, 0.893], with AUCs of 0.803 [95% CI: 0.702, 0.904], 0.838 [95% CI: 0.748, 0.928], and 0.840 [95% CI: 0.748, 0.932]). A variety of approaches were used, ranging from extraction of individual features to deep learning and artificial intelligence methods, incorporating DCE and DWI alone or in combination. Conclusion The BMMR2 challenge identified several models with high predictive performance, which may further expand the value of multiparametric breast MRI as an early marker of treatment response. Clinical trial registration no. NCT01042379 Keywords: MRI, Breast, Tumor Response Supplemental material is available for this article. © RSNA, 2024.
Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética Multiparamétrica , Feminino , Humanos , Pessoa de Meia-Idade , Inteligência Artificial , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Imageamento por Ressonância Magnética , Terapia Neoadjuvante , Resposta Patológica Completa , AdultoRESUMO
PURPOSE: VERDICT (Vascular, Extracellular, Restricted Diffusion for Cytometry in Tumours) MRI is a multi b-value, variable diffusion time DWI sequence that allows generation of ADC maps from different b-value and diffusion time combinations. The aim was to assess precision of prostate ADC measurements from varying b-value combinations using VERDICT and determine which protocol provides the most repeatable ADC. MATERIALS AND METHODS: Forty-one men (median age: 67.7 years) from a prior prospective VERDICT study (April 2016-October 2017) were analysed retrospectively. Men who were suspected of prostate cancer and scanned twice using VERDICT were included. ADC maps were formed using 5b-value combinations and the within-subject standard deviations (wSD) were calculated per ADC map. Three anatomical locations were analysed per subject: normal TZ (transition zone), normal PZ (peripheral zone), and index lesions. Repeated measures ANOVAs showed which b-value range had the lowest wSD, Spearman correlation and generalized linear model regression analysis determined whether wSD was related to ADC magnitude and ROI size. RESULTS: The mean lesion ADC for b0b1500 had the lowest wSD in most zones (0.18-0.58x10-4 mm2/s). The wSD was unaffected by ADC magnitude (Lesion: p = 0.064, TZ: p = 0.368, PZ: p = 0.072) and lesion Likert score (p = 0.95). wSD showed a decrease with ROI size pooled over zones (p = 0.019, adjusted regression coefficient = -1.6x10-3, larger ROIs for TZ versus PZ versus lesions). ADC maps formed with a maximum b-value of 500 s/mm2 had the largest wSDs (1.90-10.24x10-4 mm2/s). CONCLUSION: ADC maps generated from b0b1500 have better repeatability in normal TZ, normal PZ, and index lesions.
Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Idoso , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos Prospectivos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologiaRESUMO
INTRODUCTION: Diffusion-weighted imaging (DWI) on MRI-linear accelerator (MR-linac) systems can potentially be used for monitoring treatment response and adaptive radiotherapy in head and neck cancers (HNC) but requires extensive validation. We performed technical validation to compare six total DWI sequences on an MR-linac and MR simulator (MR sim) in patients, volunteers, and phantoms. METHODS: Ten human papillomavirus-positive oropharyngeal cancer patients and ten healthy volunteers underwent DWI on a 1.5 T MR-linac with three DWI sequences: echo planar imaging (EPI), split acquisition of fast spin echo signals (SPLICE), and turbo spin echo (TSE). Volunteers were also imaged on a 1.5 T MR sim with three sequences: EPI, BLADE (vendor tradename), and readout segmentation of long variable echo trains (RESOLVE). Participants underwent two scan sessions per device and two repeats of each sequence per session. Repeatability and reproducibility within-subject coefficient of variation (wCV) of mean ADC were calculated for tumors and lymph nodes (patients) and parotid glands (volunteers). ADC bias, repeatability/reproducibility metrics, SNR, and geometric distortion were quantified using a phantom. RESULTS: In vivo repeatability/reproducibility wCV for parotids were 5.41%/6.72%, 3.83%/8.80%, 5.66%/10.03%, 3.44%/5.70%, 5.04%/5.66%, 4.23%/7.36% for EPIMR-linac, SPLICE, TSE, EPIMR sim, BLADE, RESOLVE. Repeatability/reproducibility wCV for EPIMR-linac, SPLICE, TSE were 9.64%/10.28%, 7.84%/8.96%, 7.60%/11.68% for tumors and 7.80%/9.95%, 7.23%/8.48%, 10.82%/10.44% for nodes. All sequences except TSE had phantom ADC biases within ± 0.1x10-3 mm2/s for most vials (EPIMR-linac, SPLICE, and BLADE had 2, 3, and 1 vials out of 13 with larger biases, respectively). SNR of b = 0 images was 87.3, 180.5, 161.3, 171.0, 171.9, 130.2 for EPIMR-linac, SPLICE, TSE, EPIMR sim, BLADE, RESOLVE. CONCLUSION: MR-linac DWI sequences demonstrated near-comparable performance to MR sim sequences and warrant further clinical validation for treatment response assessment in HNC.
Assuntos
Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Imagem Ecoplanar/métodosRESUMO
Gas-filled microbubbles are potentially useful theranostic agents for magnetic resonance imaging-guided focused ultrasound surgery (MRIgFUS). Previously, MRI at 9.4 T was used to measure the contrast properties of lipid-coated microbubbles with gadolinium (Gd(III)) bound to lipid headgroups, which revealed that the longitudinal molar relaxivity (r(1)) increased after microbubble fragmentation. This behavior was attributed to an increase in water proton exchange with the Gd(III)-bound lipid fragments caused by an increase in the lipid headgroup area that accompanied the lipid shell monolayer-to-bilayer transition. In this article, we explore this mechanism by comparing the changes in r(1) and its transverse counterpart, r(2)*, after the fragmentation of microbubbles consisting of Gd(III) bound to two different locations on the lipid monolayer shell: the phosphatidylethanolamine (PE) lipid headgroup region or the distal region of the poly(ethylene glycol) (PEG) brush. Nuclear magnetic resonance (NMR) at 1.5 T was used to measure the contrast properties of the various microbubble constructs because this is the most common field strength used in clinical MRI. Results for the lipid-headgroup-labeled Gd(III) microbubbles revealed that r(1) increased after microbubble fragmentation, whereas r(2)* was unchanged. An analysis of PEG-labeled Gd(III) microbubbles revealed that both r(1) and r(2)* decreased after microbubble fragmentation. Further analysis revealed that the microbubble gas core enhanced the transverse MR signal (T(2)*) in a concentration-dependent manner but minimally affected the longitudinal (T(1)) signal. These results illustrate a new method for the use of NMR to measure the biomembrane packing structure and suggest that two mechanisms, proton-exchange enhancement by lipid membrane relaxation and magnetic field inhomogeneity imposed by the gas/liquid interface, may be used to detect and differentiate Gd(III)-labeled microbubbles and their cavitation fragments with MRI.
Assuntos
Gadolínio/química , Microbolhas , Fosfatidiletanolaminas/química , Polietilenoglicóis/química , Espectroscopia de Ressonância MagnéticaRESUMO
PURPOSE: To assess the technical performance of the apparent diffusion coefficient (ADC) on a dedicated 3T radiotherapy scanner, using a standardized phantom and sequences. Investigations into factors that could impact the technical performance of ADC in the clinic were also completed, including changing the slice-encoded imaging direction and the reference sample ADC value. METHODS: ADC acquisitions were performed monthly on an isotropic diffusion phantom over 1 year. Measurements of ADC %bias, coefficients of variation for short-/long-term repeatability and precision (CVST /CVLT and CVP ), and b-value dependency (Depb ) were calculated. The measurements were then assessed according to the Quantitative Imaging Biomarker Alliance (QIBA) Diffusion Profile specifications. RESULTS: The average of all measurements over the year was within Profile recommended ranges. This included when testing was performed in different imaging directions, and on samples that had different ADC reference values (0.4-1.1 µm2 /ms). Results in the axial plane for the central water vial included a bias of +0.05%, CVST /CVLT /CVP = 0.1%/ 0.9%/0.4% and Depb = 0.4%. CONCLUSIONS: The technical performance of ADC on a radiotherapy dedicated MRI scanner over the course of 12 months was considered conformant to the QIBA Profile. Quantifying these metrics and factors that may affect the performance is essential in progressing the use of ADC clinically: ensuring that the observed change of ADC in a tissue is due to a physiological response and not measurement variability.
Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Biomarcadores , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
BACKGROUND: Enhanced Recovery After Surgery (ERAS) programs have demonstrated improved outcomes in noncardiac surgery. More recently, ERAS has been applied to cardiac surgery with promising results. We have implemented cardiac ERAS at our community-based program, aiming to improve all phases of care, and now report our early results. METHODS: We retrospectively analyzed 73 consecutive patients treated with ERAS care compared with 74 patients treated before implementing ERAS. Our ERAS program consisted of 6 perioperative care bundles including enhanced patient education, shortened preoperative fasting period and oral carbohydrate load, postoperative nausea prophylaxis, multimodal opioid-sparing analgesia, early extubation, and early mobilization. RESULTS: ERAS patients required significantly less opioids captured as total morphine milligram equivalents (MME) (median 35.0 vs 75.3; P < .001), less nausea as determined by fewer total ondansetron rescue doses (median 0 vs 0.5; P = .011), and less lightheadedness (P = .028) compared with pre-ERAS patients. Postoperative mobility was significantly better (postoperative day 4: 95% vs 81%; P = .013) and postoperative length of stay was lower for ERAS care but did not reach statistical significance (median 4 days vs 5 days; P = .06). There was no difference in pain or glucose control or in early extubation. CONCLUSIONS: Cardiac ERAS significantly decreased opioid use, nausea, and lightheadedness and improved functional outcome for cardiac surgical patients in a community hospital.
Assuntos
Recuperação Pós-Cirúrgica Melhorada , Analgésicos Opioides/uso terapêutico , Tontura , Humanos , Tempo de Internação , Náusea/tratamento farmacológico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Estudos RetrospectivosRESUMO
In diffusion-weighted MRI (DW-MRI), choice of b-value influences apparent diffusion coefficient (ADC) values by probing different aspects of the tissue microenvironment. As a secondary analysis of the multicenter ECOG-ACRIN A6698 trial, the purpose of this study was to investigate the impact of alternate b-value combinations on the performance and repeatability of tumor ADC as a predictive marker of breast cancer treatment response. The final analysis included 210 women who underwent standardized 4-b-value DW-MRI (b = 0/100/600/800 s/mm2) at multiple timepoints during neoadjuvant chemotherapy treatment and a subset (n = 71) who underwent test−retest scans. Centralized tumor ADC and perfusion fraction (fp) measures were performed using variable b-value combinations. Prediction of pathologic complete response (pCR) based on the mid-treatment/12-week percent change in each metric was estimated by area under the receiver operating characteristic curve (AUC). Repeatability was estimated by within-subject coefficient of variation (wCV). Results show that two-b-value ADC calculations provided non-inferior predictive value to four-b-value ADC calculations overall (AUCs = 0.60−0.61 versus AUC = 0.60) and for HR+/HER2− cancers where ADC was most predictive (AUCs = 0.75−0.78 versus AUC = 0.76), p < 0.05. Using two b-values (0/600 or 0/800 s/mm2) did not reduce ADC repeatability over the four-b-value calculation (wCVs = 4.9−5.2% versus 5.4%). The alternate metrics ADCfast (b ≤ 100 s/mm2), ADCslow (b ≥ 100 s/mm2), and fp did not improve predictive performance (AUCs = 0.54−0.60, p = 0.08−0.81), and ADCfast and fp demonstrated the lowest repeatability (wCVs = 6.71% and 12.4%, respectively). In conclusion, breast tumor ADC calculated using a simple two-b-value approach can provide comparable predictive value and repeatability to full four-b-value measurements as a marker of treatment response.
Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Benchmarking , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Terapia Neoadjuvante/métodos , Curva ROC , Microambiente TumoralRESUMO
Recent innovations in quantitative magnetic resonance imaging (MRI) measurement methods have led to improvements in accuracy, repeatability, and acquisition speed, and have prompted renewed interest to reevaluate the medical value of quantitative T1. The purpose of this study was to determine the bias and reproducibility of T1 measurements in a variety of MRI systems with an eye toward assessing the feasibility of applying diagnostic threshold T1 measurement across multiple clinical sites. We used the International Society of Magnetic Resonance in Medicine/National Institute of Standards and Technology (ISMRM/NIST) system phantom to assess variations of T1 measurements, using a slow, reference standard inversion recovery sequence and a rapid, commonly-available variable flip angle sequence, across MRI systems at 1.5 tesla (T) (two vendors, with number of MRI systems n = 9) and 3 T (three vendors, n = 18). We compared the T1 measurements from inversion recovery and variable flip angle scans to ISMRM/NIST phantom reference values using Analysis of Variance (ANOVA) to test for statistical differences between T1 measurements grouped according to MRI scanner manufacturers and/or static field strengths. The inversion recovery method had minor over- and under-estimations compared to the NMR-measured T1 values at both 1.5 T and 3 T. Variable flip angle measurements had substantially greater deviations from the NMR-measured T1 values than the inversion recovery measurements. At 3 T, the measured variable flip angle T1 for one vendor is significantly different than the other two vendors for most of the samples throughout the clinically relevant range of T1. There was no consistent pattern of discrepancy between vendors. We suggest establishing rigorous quality control procedures for validating quantitative MRI methods to promote confidence and stability in associated measurement techniques and to enable translation of diagnostic threshold from the research center to the entire clinical community.