Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Epilepsia ; 65(8): 2280-2294, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38780375

RESUMO

OBJECTIVE: This study was undertaken to develop and evaluate a machine learning-based algorithm for the detection of focal to bilateral tonic-clonic seizures (FBTCS) using a novel multimodal connected shirt. METHODS: We prospectively recruited patients with epilepsy admitted to our epilepsy monitoring unit and asked them to wear the connected shirt while under simultaneous video-electroencephalographic monitoring. Electrocardiographic (ECG) and accelerometric (ACC) signals recorded with the connected shirt were used for the development of the seizure detection algorithm. First, we used a sliding window to extract linear and nonlinear features from both ECG and ACC signals. Then, we trained an extreme gradient boosting algorithm (XGBoost) to detect FBTCS according to seizure onset and offset annotated by three board-certified epileptologists. Finally, we applied a postprocessing step to regularize the classification output. A patientwise nested cross-validation was implemented to evaluate the performances in terms of sensitivity, false alarm rate (FAR), time in false warning (TiW), detection latency, and receiver operating characteristic area under the curve (ROC-AUC). RESULTS: We recorded 66 FBTCS from 42 patients who wore the connected shirt for a total of 8067 continuous hours. The XGBoost algorithm reached a sensitivity of 84.8% (56/66 seizures), with a median FAR of .55/24 h and a median TiW of 10 s/alarm. ROC-AUC was .90 (95% confidence interval = .88-.91). Median detection latency from the time of progression to the bilateral tonic-clonic phase was 25.5 s. SIGNIFICANCE: The novel connected shirt allowed accurate detection of FBTCS with a low false alarm rate in a hospital setting. Prospective studies in a residential setting with a real-time and online seizure detection algorithm are required to validate the performance and usability of this device.


Assuntos
Algoritmos , Eletroencefalografia , Convulsões , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Feminino , Adulto , Eletroencefalografia/métodos , Convulsões/diagnóstico , Convulsões/fisiopatologia , Pessoa de Meia-Idade , Adulto Jovem , Eletrocardiografia/métodos , Estudos Prospectivos , Adolescente , Aprendizado de Máquina , Acelerometria/métodos , Acelerometria/instrumentação , Epilepsia Tônico-Clônica/diagnóstico , Epilepsia Tônico-Clônica/fisiopatologia
2.
Can J Neurol Sci ; : 1-4, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38572541

RESUMO

Wearable-based seizure detection devices hold promise in reducing seizure-related adverse events and relieving the daily stress experienced by people with epilepsy. In this work, we present the latest evidence regarding the performance of three seizure detection wearables (eight studies) commercially available in Canada to provide guidance to clinicians. Overall, their ability to detect focal-to-bilateral and/or generalized tonic-clonic seizures ranges between 21.0% and 98.15% in sensitivity, with the 24h false alarm rates ranging from 0 to 1.28. While performance in epilepsy monitoring units show promise, the lack of evidence in outpatient settings precludes strong recommendations for their use in daily life.

3.
Epilepsia Open ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980984

RESUMO

OBJECTIVE: Non-invasive biomarkers have recently shown promise for seizure forecasting in people with epilepsy. In this work, we developed a seizure-day forecasting algorithm based on nocturnal sleep features acquired using a smart shirt. METHODS: Seventy-eight individuals with epilepsy admitted to the Centre hospitalier de l'Université de Montréal epilepsy monitoring unit wore the Hexoskin biometric smart shirt during their stay. The shirt continuously measures electrocardiography, respiratory, and accelerometry activity. Ten sleep features, including sleep efficiency, sleep latency, sleep duration, time spent in non-rapid eye movement sleep (NREM) and rapid eye movement sleep (REM), wakefulness after sleep onset, average heart and breathing rates, high-frequency heart rate variability, and the number of position changes, were automatically computed using the Hexoskin sleep algorithm. Each night's features were then normalized using a reference night for each patient. A support vector machine classifier was trained for pseudo-prospective seizure-day forecasting, with forecasting horizons of 16- and 24-h to include both diurnal and nocturnal seizures (24-h) or diurnal seizures only (16-h). The algorithm's performance was assessed using a nested leave-one-patient-out cross-validation approach. RESULTS: Improvement over chance (IoC) performances were achieved for 48.7% and 40% of patients with the 16- and 24-h forecasting horizons, respectively. For patients with IoC performances, the proposed algorithm reached mean IoC, sensitivity and time in warning of 34.3%, 86.0%, and 51.7%, respectively for the 16-h horizon, and 34.2%, 64.4% and 30.2%, respectively, for the 24-h horizon. SIGNIFICANCE: Smart shirt-based nocturnal sleep analysis holds promise as a non-invasive approach for seizure-day forecasting in a subset of people with epilepsy. Further investigations, particularly in a residential setting with long-term recordings, could pave the way for the development of innovative and practical seizure forecasting devices. PLAIN LANGUAGE SUMMARY: Seizure forecasting with wearable devices may improve the quality of life of people living with epilepsy who experience unpredictable, recurrent seizures. In this study, we have developed a seizure forecasting algorithm using sleep characteristics obtained from a smart shirt worn at night by a large number of hospitalized patients with epilepsy (78). A daily seizure forecast was generated following each night using machine learning methods. Our results show that around half of people with epilepsy may benefit from such an approach.

4.
Comput Struct Biotechnol J ; 24: 66-86, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204455

RESUMO

Background: Computational analysis of routine electroencephalogram (rEEG) could improve the accuracy of epilepsy diagnosis. We aim to systematically assess the diagnostic performances of computed biomarkers for epilepsy in individuals undergoing rEEG. Methods: We searched MEDLINE, EMBASE, EBM reviews, IEEE Explore and the grey literature for studies published between January 1961 and December 2022. We included studies reporting a computational method to diagnose epilepsy based on rEEG without relying on the identification of interictal epileptiform discharges or seizures. Diagnosis of epilepsy as per a treating physician was the reference standard. We assessed the risk of bias using an adapted QUADAS-2 tool. Results: We screened 10 166 studies, and 37 were included. The sample size ranged from 8 to 192 (mean=54). The computed biomarkers were based on linear (43%), non-linear (27%), connectivity (38%), and convolutional neural networks (10%) models. The risk of bias was high or unclear in all studies, more commonly from spectrum effect and data leakage. Diagnostic accuracy ranged between 64% and 100%. We observed high methodological heterogeneity, preventing pooling of accuracy measures. Conclusion: The current literature provides insufficient evidence to reliably assess the diagnostic yield of computational analysis of rEEG. Significance: We provide guidelines regarding patient selection, reference standard, algorithms, and performance validation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa