Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Rev Cardiovasc Med ; 23(11): 358, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39076178

RESUMO

Background: The impact of nodular calcifications in left ventricular outlow tract (LVOT) and aortic annulus on the procedural outcome of transcatheter aortic valve implantation (TAVI) with new-generation devices is yet to be elucidated. Similarly, computational simulations may provide a novel insight into the biomechanical features of TAVI devices and their interaction with nodular calcifications. Methods: This retrospective single-center study included 232 patients submitted to TAVI with Evolut-R (53.4%), Portico (33.6%) and Lotus (13.0%) devices with available preoperative computed tomography (CT) angiography and evidence of nodular calcifications in aortic annulus and/or LVOT. Calcification severity was defined ≥ moderate in presence of at least two nodules or one nodule ≤ 5 mm. Three virtual simulation models of aortic root presenting a nodular calcification of increasing size were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. Results: At least moderate calcifications were found in 123 (53.0%) patients, with no sex differences. Among the ≥ moderate calcification group, lower device success rate was evident (87.8% vs. 95.4%; p = 0.039). Higher rates of ≥ moderate paravalvular leak (PVL) (11.4% vs. 3.7%; p = 0.028) and vascular complications (9.8% vs. 2.8%; p = 0.030) were also observed. Among the Evolut-R group, higher rates of at ≥ moderate PVL (12.1%) were observed compared to Portico (3.8%; p = 0.045) and Lotus (0.0%; p = 0.044) groups. Calcification of both annulus and LVOT (odds ratio [OR] 0.105; p = 0.023) were independent predictors of device success. On computational simulations, Portico exhibited homogeneous stress distribution by increasing calfications and overall a larger paravalvular orifice areas compared to Evolut-R and Lotus. Evolut-R showed higher values of average stress than Portico, although with a more dishomogeneous distribution leading to greater paravalvular orifice areas by severe calcifications. Lotus showed overall small paravalvular orifice areas, with no significant increase across the three models. Conclusions: At least moderate nodular calcifications in the annulus/LVOT region significantly affected TAVI outcome, as they were independent predictors of device success. Lotus and Portico seemed to perform better than Evolut-R as for device success and ≥ moderate PVL. Computational simulations revealed unique biomechanical features of the investigated devices in terms of stent compliance and radial force.

2.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34939726

RESUMO

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Ventrículos do Coração , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Função Ventricular Direita
3.
Catheter Cardiovasc Interv ; 98(6): E847-E854, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33960624

RESUMO

AIMS: The aim of this proof-of-concept study was to investigate safety and efficacy of a CT-scan based patient-specific algorithm to maximize coronary clearance and secondarily to achieve anatomically correct commissural alignment with the Acurate Neo device. METHOD AND RESULTS: A total of 45 consecutive patients undergoing TAVR with the Acurate Neo THV were prospectively enrolled in the study. Mean age was 81.6 ± 5.5 years, mean STS score was 6.1 ± 3.7. Device success rate was 100%. Aim of the technique was to rotationally deploy the TAVR device with a commissure lying on the bisector between the coronary ostia as calculated on the pre-procedural CT-scan. At post-TAVR CT-scan, coronary clearance was achieved in 98% of patients with no cases of severe coronary artery overlap. In 42 out of 45 patients, THV was aligned or, at most, mildly misaligned; there were 2 cases of moderate misalignment without any case of severe misalignment. Post-TAVR selective coronary artery engagement was attempted and succeeded in all patients (100%). CONCLUSION: Our CT-scan based patient-specific algorithm is safe and proven to be effective in avoiding coronary artery overlap and providing commissural alignment with Acurate Neo in all treated patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 98(1): E145-E152, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33155757

RESUMO

OBJECTIVE: This study sought to investigate the procedural and mid-term outcomes of transcatheter aortic valve implantation for failed surgical bioprostheses (TAVI-ViV) with Portico device. BACKGROUND: Limited evidence coming from early experience on Portico system does not allow to fully assess safety and efficacy of this device in this ViV patients. METHODS: From January 2016 up to June 2019, 56 consecutive patients undergoing TAVI-ViV with Portico were prospectively included in our institutional TAVI database. RESULTS: The prevalent mechanism of failure was stenosis (58.9%); true internal diameter (ID) was <21 mm in 71.4% of cases. Device success rate were 69.6% with 14 (25%) patients showing a residual gradient ≥20 mmHg, 2 (3.6%) a PVL ≥ moderate and 1 (1.8%) required a second THV implantation due to device embolization. At 1-year follow-up 5 patients (8.9%) died whereas moderate SVD was reported in 2 (3.6%). Patients with a post-procedural mean gradient ≥20 mmHg showed a significantly higher rate of CV hospitalization (21.4% vs. 2.4%, p = .02) whereas no differences in procedural and 1-year outcomes were noticed according to true ID diameter or degeneration mode. Chimney stenting (ChT) was performed in 23 (41%) patients without significant differences in procedural and 1-year outcomes compared to non-ChT group. CONCLUSIONS: TAVI-ViV with Portico valve was associated with good procedural and 1-year outcomes, even in patients with features of high procedural and anatomical complexity.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 97(1): E135-E145, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400068

RESUMO

OBJECTIVES: To investigate paravalvular leak (PVL) and devices success rates according to aortic angle (AA) in patients undergoing transcatheter aortic valve implantation (TAVI) with three new-generation self-expanding devices. BACKGROUND: The impact of aortic angle (AA) on TAVI device success and PVL rates is controversial. METHODS: This retrospective study included 392 patients submitted to TAVI for severe aortic stenosis with Portico, Evolut-R and Acurate-NEO, and available AA measurements at computed tomography (CT) angiography. AA was calculated from the implantation projection and was defined as the angle between the plane of aortic annulus and an ideal horizontal plane. Aorta was defined horizontal if AA>57° (75th percentile). RESULTS: In the horizontal group, the rates of moderate/severe PVL was higher in the Evolut-R group (20.8%), which was also characterized by a lower implant compared to that of Acurate-NEO, whereas device success was comparable among the three devices. AA was a significant predictor of moderate/severe PVLs (AUC 0.72, p = .002) only in the Evolut-R population. On multivariate analysis, calcium volume 850HU, bicuspid aortic valve, and implantation depth at the level of left coronary cusp were independent predictors of moderate/severe PVL. On univariate analysis in the horizontal aorta population, implantation depth was confirmed among the most significant predictors of moderate/severe PVL. CONCLUSIONS: Despite comparable device success rates, horizontal aorta represented a technical challenge only in the Evolut-R subgroup, which showed higher rates of moderate/severe PVL than Portico and Acurate-NEO, and was associated with a low implant.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Complicações Pós-Operatórias , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Eur Heart J ; 41(20): 1876-1886, 2020 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31904800

RESUMO

AIMS: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). METHODS AND RESULTS: Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). CONCLUSION: While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
7.
Am Heart J ; 217: 32-41, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31473325

RESUMO

Limited evidence is available on 5-year clinical outcomes after percutaneous edge-to-edge mitral valve repair. METHODS: The Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation in ITaly (GRASP-IT) is a multicenter registry including 304 consecutive patients undergoing Mitraclip between October 2008 and October 2013 at 4 Italian centers. Primary end point (all-cause mortality) and secondary end point (all-cause mortality or heart failure [HF] hospitalization) were evaluated up to 5 years and between 1 and 5 years. RESULTS: Cumulative incidence of the primary and secondary end points at 1, 2, 3, 4, and 5 years were 15.1%, 26.4%, 35.5%, 42.1%, and 47.3% and 29.1%, 41.7%, 49.8%, 56%, and 62.3%, respectively. Landmark analysis between 1 and 5 years showed an incidence of primary and secondary end point of 37.9% and 46.8%, respectively. Five-year event rates were significantly higher in patients with functional ischemic mitral regurgitation (MR) compared to other etiologies. MR recurrence and left ventricular ejection fraction <30% were associated with an increased risk of both primary and secondary end points. EuroSCORE II >5% was associated with an increased risk of 5-year mortality. Ischemic etiology of MR, baseline serum creatinine >1.5 mg/dL, chronic obstructive pulmonary disease, and previous HF hospitalizations were independent predictors of 5-year secondary end point. CONCLUSIONS: At 5-year follow-up after Mitraclip, nearly half of patients died and almost two thirds died or were admitted for HF. MR recurrence, ischemic etiology, high comorbidity burden (ie, EuroSCORE II >5%, chronic obstructive pulmonary disease), and advanced cardiomyopathy (ie, left ventricular ejection fraction <30%, prior HF admission, creatinine >1.5 mg/dL) significantly increase the relative risk of 5-year clinical events.


Assuntos
Insuficiência Cardíaca/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Idoso , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Causas de Morte , Feminino , Insuficiência Cardíaca/etiologia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Itália , Masculino , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/mortalidade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Recidiva , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
8.
Catheter Cardiovasc Interv ; 90(7): 1206-1211, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28145039

RESUMO

OBJECTIVES: We report procedural and 30-day clinical outcomes following transcatheter aortic valve replacement (TAVR) with Lotus Valve system in a high-risk population. BACKGROUND: Lotus valve is a second-generation TAVR fully repositionable and retrievable device. RELEVANT (REgistry of Lotus valvE for treatment of aortic VAlve steNosis with Tavr) study is an Italian prospective multicentre registry. METHODS: Five major centers performing TAVR using Lotus participated. All high-risk symptomatic patients with severe aortic stenosis were evaluated by a heart team and screened for eligibility for TAVR. Primary end-points were procedural and 30-day mortality. Secondary endpoints included procedural and 30-day safety/effectiveness metrics according to Valve Academic Research Consortium (VARC)-2 criteria. RESULTS: Two hundred and twenty-five patients undergoing TAVR with Lotus were enrolled. Mean age was 82.6 ± 6.3 years, 51.6% females. Mean STS score for mortality was 8.3 ± 5.6. Procedural success was achieved in 98.7% of patients. All-cause mortality was 2.2% at discharge and 2.7% at 30-day. Stroke rate was 2.2% at discharge and 3.1% at 30-day. Patients requiring a new permanent pacemaker implantation were 30.7% at discharge and 31.8% at 30-day. Paravalvular regurgitation (PVR) was trace/mild in 99.1% of patients at discharge. Only two patients (0.9%) had moderate PVR at discharge and at 30-day, whereas none had severe PVR. CONCLUSIONS: RELEVANT study showed that TAVR using Lotus, in a real-world population of patients with severe aortic stenosis at high surgical risk, was associated with excellent device success implantation and early safety according to VARC-2 definition. The pacemaker implantation rate was about a third of patients. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Itália , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
10.
Eur Heart J Suppl ; 18(Suppl E): E86-E95, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-28533722

RESUMO

Transcatheter aortic valve replacement determined a paradigm shift in the treatment of high-risk patients with severe symptomatic aortic valve stenosis. Notwithstanding the impressive results of the first-generation prostheses, a fast-paced technological evolution is taking place to overcome their limitations, in particular the vascular access damage and the paravalvular leak. Nowadays, with the availability of several different devices, the expert operator can select the right prosthesis for the specific anatomical and clinical situation. As 'One does not fit all', the 'Tailored TAVR Approach' we describe will conceivably become the future of this therapy.

11.
Circulation ; 127(12): 1300-7, 2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23443735

RESUMO

BACKGROUND: Conduction disturbances are relatively common after transcatheter aortic valve implantation. Previous data demonstrated an adverse impact of persistent left bundle-branch block (LBBB) after surgical aortic valve replacement. It is unclear whether new-onset LBBB may also impact the prognosis of patients after transcatheter aortic valve implantation. METHODS AND RESULTS: Among 1060 patients treated with a CoreValve Revalving System transcatheter aortic valve implantation between October 2007 and April 2011 in high-volume centers in Italy, we analyzed those without LBBB or pacemaker at admission (879 patients [82.9%]). We further excluded those who underwent permanent pacemaker implantation within 48 hours after the procedure (61 patients [7%]), for a final study population of 818 patients. Among them, 224 patients (group A; 27.4%) developed a persistent LBBB and the remaining 594 (group B; 72.6%) did not. Clinical characteristics were similar between groups. A low implantation was significantly more frequent in group A (15% versus 9.8%, P=0.02). No patients were censored before 1 year (median follow-up period 438 days, interquartile range 174-798 days). Survival analyses and inherent log-rank tests showed that LBBB was not associated with higher all-cause mortality, cardiac mortality, or hospitalization for heart failure at 30 days or 1 year. At 30 days, but not at 1 year, group A had a significantly higher rate of pacemaker implantation. CONCLUSIONS: In this registry of high-volume centers, persistent LBBB after CoreValve Revalving System transcatheter aortic valve implantation showed no effect on hard end points. On the other hand, LBBB was associated with a higher short-term rate of pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/complicações , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Bloqueio de Ramo/terapia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Marca-Passo Artificial , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
12.
Circulation ; 128(19): 2145-53, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24088530

RESUMO

BACKGROUND: Little is known of the prognostic significance of mitral regurgitation (MR) on transcatheter aortic valve replacement (TAVR), the impact of TAVR on MR severity, and the variables associated with possible post-TAVR improvement in MR. We evaluated these issues in a multicenter registry of patients undergoing CoreValve Revalving System-TAVR. METHODS AND RESULTS: Among 1007 consecutive patients, 670 (66.5%), 243 (24.1%), and 94 (9.3%) presented with no/mild, moderate, and severe MR, respectively. At 1 month after TAVR, patients with severe or moderate MR showed comparable mortality rates (odds ratio, 1.1; 95% confidence interval [95% CI], 0.7-1.55; P=0.2), but both were significantly higher compared with patients with mild/no MR (odds ratio, 2.2; 95% CI, 1.78-3.28; P<0.001; and odds ratio, 1.9; 95% CI, 1.1-3.3; P=0.02, respectively). One-year mortality was also similar between patients with severe and those with moderate MR (hazard ratio, 1.4; 95% CI, 0.94-2.4; P=0.06) and still significantly higher compared with patients with mild/no MR (hazard ratio, 1.7; 95% CI, 1.2-3.41; P<0.001; and hazard ratio, 1.4; 95% CI, 1.2-2.2; P=0.03, respectively). Severe pulmonary hypertension, atrial fibrillation, and MR more than mild, but not an improvement of ≥1 grade in MR severity, were independent predictors of mortality at 1 year. At 1 year, an improved MR was observed in 47% and 35% of patients with severe and moderate MR, respectively. The rate of low implantation was consistent across groups with improved, unchanged, or worsened MR. A functional type of MR and the absence of severe pulmonary hypertension and atrial fibrillation independently predicted the improvement in MR severity. CONCLUSIONS: Baseline MR greater than mild is associated with higher mortality after CoreValve Revalving System-TAVR. A significant improvement in MR was more likely in patients with functional MR and without severe pulmonary hypertension or atrial fibrillation. The improvement in MR did not independently predict mortality.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência da Valva Mitral/mortalidade , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Sistema de Registros/estatística & dados numéricos , Índice de Gravidade de Doença
13.
Catheter Cardiovasc Interv ; 84(2): 264-71, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24408011

RESUMO

BACKGROUND: The impact of female sex on mortality after transcatheter aortic valve implantation (TAVI) is controversial. Post-procedural aortic regurgitation (AR) ≥ 2 has been associated with poor outcomes. Whether sex differences in post-procedural AR ≥ 2 could contribute to a mortality difference between women and men is not known. METHODS: Six hundred fifty-six patients, women (53.1%), men (46.9%), with aortic stenosis underwent TAVI with the CoreValve system (92.8%) or the Edwards SAPIEN valve system (7.2%). AR was graded semiquantitatively as 0 = none, 1 = trivial, 2 = mild, 3 = moderate, and 4 = severe. The incidence of post-procedural AR ≥ 2 was reported. RESULTS: Procedural success was similar in women as compared to men (97.9 vs 96.7%, P = 0.32). Post-procedural AR ≥ 2 occurred less frequently in women than in men (20.9 vs 29.6%, P = 0.01). After a median follow-up of 434 days, all-cause mortality tended to be lower in women than in men (20.7 vs 26.6%, logrank P = 0.10), and was significantly higher in patients with AR ≥ 2 than in those without (34.8 vs 19.7%, logrank P < 0.001). AR ≥ 2 [hazard ratio (HR) 1.73, 95% confidence interval (CI) 1.22-2.43, P = 0.002], but not female sex (P = 0.17) was an independent predictor of all-cause death at multivariable Cox regression. The predictive value of AR ≥ 2 was restricted to men (HR 2.96, P < 0.001 among men; HR 0.86, P = 0.60 among women; P for interaction = 0.002). CONCLUSIONS: Women, as compared to men, present a trend toward lower mortality. A significant lower incidence of post-procedural AR ≥ 2 among women contributes to this finding. Female sex, however, was not a significant independent predictor of death.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/terapia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento
14.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710782

RESUMO

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Aorta/diagnóstico por imagem , Aorta/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas , Estudos Retrospectivos
15.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599692

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seguimentos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
16.
Cardiovasc Revasc Med ; 55: 22-27, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37076413

RESUMO

BACKGROUND: TAVR is an established treatment for patients with severe symptomatic aortic stenosis. Different THV platforms are nowadays available, each of them with its inherent limitations and others are under development aiming at overcoming such limitations. We thus sought to investigate the performance and 1-year clinical outcome of a new generation, balloon expandable, THV: the Myval™ (Meril Life Sciences Pvt. Ltd., Vapi, Gujarat, India). METHODS: This registry included the first 100 consecutive patients (mean age 80.7 ± 7.7; STS 4.3 ± 3.3 %), who underwent transcatheter aortic valve implantation for severe stenosis of the native aortic valve from May 2020 to December 2020, in two Italian Centers. Clinical and procedural outcomes were defined according to VARC-3 criteria. RESULTS: Transfemoral Myval THV was successfully implanted in all patients, with no intra-hospital mortality (technical success 100 %): vascular access complications were all "minor" (16 %), and managed by compression/balloon inflation; no cases of annular rupture or coronary obstruction occurred; 5 % of patients required an in-hospital pacemaker implantation (PM). Device success was 99 %. Overall and cardiovascular mortality were 6 % (CI 5 %-7 %) and 4 % (CI 2 %-5 %) at 1- year, while 12 % (CI 9 %-14 %) and 7 % (6-9 %) at 2 years. A total of 9 % of the patients required a PM within 12 months, and no further PM implantation occurred afterwards. No cerebrovascular events, renal failure and myocardial infarction occurred between discharge and 2-year follow-up. No events of structural valve deterioration but a sustained improvement of echocardiographic parameters were observed. CONCLUSION: The Myval THV has a promising safety/efficacy profile at 2 year follow up. This performance should be further evaluated in the context of randomized trials to better elucidate its potential.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese
17.
Am Heart J ; 163(3): 492-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22424022

RESUMO

BACKGROUND: Conduction abnormalities are frequent after transcatheter aortic valve implantation with the CoreValve (Medtronic, Minneapolis, MN) and are often treated with liberal permanent pacemaker (PPM) implantation. Our aim was to assess the 1-year outcome of a conservative approach to pacing and to identify its predictors. METHODS: We analyzed 275 consecutive patients without a PPM before transcatheter aortic valve implantation who underwent successful CoreValve implantation at our 3 centers, sharing a conservative approach to pacing. RESULTS: Of the 47 patients (17.1%) who developed postprocedural complete atrioventricular block, 14 recovered spontaneous atrioventricular conduction <72 hours and did not receive a PPM. Sixty-six patients (24.0%) received a PPM before discharge, and 74 more patients (26.9%) developed a new left bundle-branch block (LBBB). Independent predictors of PPM implantation were as follows: lower CoreValve implantation below the aortic annulus (odds ratio [OR] 1.16/mm, 95% CI 1.03-1.30, P = .01), right bundle-branch block (OR 3.72, 95% CI 1.5-9.2, P = .004), left anterior hemiblock (OR 2.34, 95% CI 1.1-5.1, P = .03), and longer PR interval (OR 1.02/ms, 95% CI 1.00-1.04, P = .03). One-year survival was similar between patients who received a PPM and patients who did not receive a PPM (P = .90), with no case of sudden death in the latter group, and between patients with a new LBBB not receiving a PPM and patients without postprocedural LBBB (P = .37). CONCLUSION: A high CoreValve implantation level and avoidance of prophylactic pacing in patients with new LBBB without persistent bradyarrhythmias allowed for a relatively low rate of PPM implantation. This conservative approach spared unwarranted pacing and did not affect 1-year survival.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Marca-Passo Artificial/normas , Guias de Prática Clínica como Assunto/normas , Idoso , Estenose da Valva Aórtica/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento
18.
Cardiovasc Revasc Med ; 35: 19-26, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33933374

RESUMO

PURPOSE: To compare in-hospital outcome of Evolut-R 34 mm vs. smaller Evolut-R devices and to identify predictors of paravalvular leak (PVL) and deep implantation specific for Evolut-R 34 mm. METHODS: This single-center retrospective study included 359 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with Evolut-R 34 mm (N = 84,23.4%) and Evolut-R 23/26/29 mm (N = 275,76.6%) between 2016 and 2019. RESULTS: Patients in Evolut-R 34 mm group were more frequently males, had lower STS score, ejection fraction, and mean aortic gradient compared to the Evolut-R 23/26/29 mm group. Horizontal aorta and large LVOT were more frequent findings in the Evolut-R 34 mm group, whereas calcium volume was comparable among the groups. During TAVR, mean implantation depth and contrast volume were greater in the Evolut-R 34 mm group, compared to the Evolut 23/26/29 mm group. Post-procedurally, 30-day mortality, ≥moderate PVL, device success and pacemaker implantation (PM) rates were comparable between groups. Among independent predictors of ≥moderate PVL, calcium volume (OR:1.04; p < 0.001) was predictive with different thresholds in both groups, whereas aortic angulation (OR:1.40; p = 0.005) was predictive only in Evolut-R 34 mm group at a cutoff of 60° (AUC:0.73; p = 0.043). Body weight (OR:1.03; p = 0.027), left ventricular outflow tract (LVOT) diameter (OR:1.34; p = 0.001), and mean aortic gradient (OR:0.96; p = 0.006) were independent predictors of deep implantation (mean depth ≥ 6 mm), with LVOT>27 mm being predictive specifically for Evolut-R 34 mm (AUC:0.66; p = 0.024). CONCLUSIONS: TAVR with Evolut-R 34 mm and Evolut-R 23/26/29 mm showed comparable in-hospital outcome. Aortic angulation >60° and LVOT >27 mm were predictive respectively of ≥moderate PVL and deep implantation specifically in Evolut-R 34 mm patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hospitais , Humanos , Masculino , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Front Cardiovasc Med ; 9: 931207, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966561

RESUMO

Background: A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim: We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods: The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results: Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM (p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion: After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration: [https://clinicaltrials.gov], identifier [NCT04500964].

20.
J Mech Behav Biomed Mater ; 123: 104772, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34481297

RESUMO

Computational simulations of Transcatheter Aortic Valve Implantation (TAVI) have reached a high level of complexity and accuracy for the prediction of possible implantation scenarios during the decision-making process. However, when focusing on the prosthetic device, currently different devices are available on the market which not only have different geometries, but also different material properties. The present work focuses on the calibration of Nitinol constitutive parameters of four self-expandable devices starting from experimental radial force tests on the prosthetic samples. Beside providing optimal material properties for each specific device, we also perform a patient-specific simulation, comparing the results obtained using both "literature" and calibrated parameters with the aim of investigating the impact of metallic frame parameters choice on simulation results.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Simulação por Computador , Análise de Elementos Finitos , Humanos , Fenômenos Mecânicos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa