Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Infect Dis ; 210 Suppl 1: S333-40, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25316852

RESUMO

Monitoring the quality of supplementary immunization activities (SIAs) is a key tool for polio eradication. Regular monitoring data, however, are often unreliable, showing high coverage levels in virtually all areas, including those with ongoing virus circulation. To address this challenge, lot quality assurance sampling (LQAS) was introduced in 2009 as an additional tool to monitor SIA quality. Now used in 8 countries, LQAS provides a number of programmatic benefits: identifying areas of weak coverage quality with statistical reliability, differentiating areas of varying coverage with greater precision, and allowing for trend analysis of campaign quality. LQAS also accommodates changes to survey format, interpretation thresholds, evaluations of sample size, and data collection through mobile phones to improve timeliness of reporting and allow for visualization of campaign quality. LQAS becomes increasingly important to address remaining gaps in SIA quality and help focus resources on high-risk areas to prevent the continued transmission of wild poliovirus.


Assuntos
Pesquisa sobre Serviços de Saúde , Imunização Secundária/métodos , Amostragem para Garantia da Qualidade de Lotes/estatística & dados numéricos , Poliomielite/prevenção & controle , Vacinas contra Poliovirus/administração & dosagem , Vacinas contra Poliovirus/imunologia , Humanos
2.
J Infect Dis ; 210 Suppl 1: S341-6, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25316853

RESUMO

BACKGROUND: To assess the quality of supplementary immunization activities (SIAs), the Global Polio Eradication Initiative (GPEI) has used cluster lot quality assurance sampling (C-LQAS) methods since 2009. However, since the inception of C-LQAS, questions have been raised about the optimal balance between operational feasibility and precision of classification of lots to identify areas with low SIA quality that require corrective programmatic action. METHODS: To determine if an increased precision in classification would result in differential programmatic decision making, we conducted a pilot evaluation in 4 local government areas (LGAs) in Nigeria with an expanded LQAS sample size of 16 clusters (instead of the standard 6 clusters) of 10 subjects each. RESULTS: The results showed greater heterogeneity between clusters than the assumed standard deviation of 10%, ranging from 12% to 23%. Comparing the distribution of 4-outcome classifications obtained from all possible combinations of 6-cluster subsamples to the observed classification of the 16-cluster sample, we obtained an exact match in classification in 56% to 85% of instances. CONCLUSIONS: We concluded that the 6-cluster C-LQAS provides acceptable classification precision for programmatic action. Considering the greater resources required to implement an expanded C-LQAS, the improvement in precision was deemed insufficient to warrant the effort.


Assuntos
Pesquisa sobre Serviços de Saúde , Imunização Secundária/métodos , Amostragem para Garantia da Qualidade de Lotes/métodos , Poliomielite/prevenção & controle , Vacinas contra Poliovirus/administração & dosagem , Vacinas contra Poliovirus/imunologia , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Nigéria
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa