Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 361(9): 858-67, 2009 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-19710484

RESUMO

BACKGROUND: The rapid and reliable diagnosis of acute myocardial infarction is a major unmet clinical need. METHODS: We conducted a multicenter study to examine the diagnostic accuracy of new, sensitive cardiac troponin assays performed on blood samples obtained in the emergency department from 718 consecutive patients who presented with symptoms suggestive of acute myocardial infarction. Cardiac troponin levels were determined in a blinded fashion with the use of four sensitive assays (Abbott-Architect Troponin I, Roche High-Sensitive Troponin T, Roche Troponin I, and Siemens Troponin I Ultra) and a standard assay (Roche Troponin T). The final diagnosis was adjudicated by two independent cardiologists. RESULTS: Acute myocardial infarction was the adjudicated final diagnosis in 123 patients (17%). The diagnostic accuracy of measurements obtained at presentation, as quantified by the area under the receiver-operating-characteristic curve (AUC), was significantly higher with the four sensitive cardiac troponin assays than with the standard assay (AUC for Abbott-Architect Troponin I, 0.96; 95% confidence interval [CI], 0.94 to 0.98; for Roche High-Sensitive Troponin T, 0.96; 95% CI, 0.94 to 0.98; for Roche Troponin I, 0.95; 95% CI, 0.92 to 0.97; and for Siemens Troponin I Ultra, 0.96; 95% CI, 0.94 to 0.98; vs. AUC for the standard assay, 0.90; 95% CI, 0.86 to 0.94). Among patients who presented within 3 hours after the onset of chest pain, the AUCs were 0.93 (95% CI, 0.88 to 0.99), 0.92 (95% CI, 0.87 to 0.97), 0.92 (95% CI, 0.86 to 0.99), and 0.94 (95% CI, 0.90 to 0.98) for the sensitive assays, respectively, and 0.76 (95% CI, 0.64 to 0.88) for the standard assay. We did not assess the effect of the sensitive troponin assays on clinical management. CONCLUSIONS: The diagnostic performance of sensitive cardiac troponin assays is excellent, and these assays can substantially improve the early diagnosis of acute myocardial infarction, particularly in patients with a recent onset of chest pain. (ClinicalTrials.gov number, NCT00470587.)


Assuntos
Infarto do Miocárdio/diagnóstico , Troponina/sangue , Idoso , Idoso de 80 Anos ou mais , Angina Instável/sangue , Angina Instável/diagnóstico , Área Sob a Curva , Biomarcadores/sangue , Dor no Peito/etiologia , Creatina Quinase Forma MB/sangue , Diagnóstico Precoce , Eletrocardiografia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Mioglobina/sangue , Curva ROC , Sensibilidade e Especificidade
2.
Case Rep Neurol ; 3(2): 136-40, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21734888

RESUMO

Widened perivascular spaces known as Virchow-Robin spaces (VRS) are often seen on MRI and are usually incidental findings. It is unclear if enlarged VRS can be associated with neurological deficits. In this report, we describe a case of lobar dementia associated with unusual VRS widening in one cerebral hemisphere. A 77-year-old woman, seen at a memory clinic, presented with progressive cognitive decline, left hemianopsia, and mild pyramidal signs on the left side. On MRI, unusually wide VRS were visible, predominantly in the right centrum semiovale and the right temporo-occipital white matter. The clinical syndrome was consistent with the extent and location of the abnormally dilated VRS. The high MR signal in white matter bridges between the VRS suggested parenchymal damage, possibly representing gliotic white matter. No evidence for another etiology was found on cerebral MRI and rCBF SPECT. As a conclusion, enlarged VRS in one cerebral hemisphere may be associated with cognitive change and neurological deficits.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa