Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Zoo Wildl Med ; 50(1): 282-286, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31120693

RESUMO

This communication briefly describes the use of tricaine methanesulfonate (MS222) to induce chemical restraint/general anesthesia of a Mexican axolotl (Ambystoma mexicanum) for the endoscopic retrieval of a gastric foreign body. There is very little published scientific literature concerning the anesthesia of Mexican axolotls. The anesthesia used in this case was an immersion bath of tricaine methanesulfonate where the concentration of tricaine methanesulfonate was gradually increased to 500 mg/L (ppm) over a 15-min period. A loss of righting reflex was observed within 3 min of attaining the final concentration of the anesthetic bath. The first voluntary movements following the transfer to a freshwater bath occurred within 7 min. The recovery was uneventful. Tricaine methanesulfonate in this case proved to be an effective anesthetic agent for a short, minimally invasive procedure.


Assuntos
Ambystoma mexicanum/lesões , Aminobenzoatos/administração & dosagem , Anestesia Geral/veterinária , Anestésicos/administração & dosagem , Endoscopia/veterinária , Corpos Estranhos/veterinária , Ambystoma mexicanum/cirurgia , Animais , Corpos Estranhos/cirurgia , Imersão , Imobilização/veterinária , Resultado do Tratamento
2.
J Neurosci Methods ; 360: 109257, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34139266

RESUMO

BACKGROUND: The chronically instrumented pregnant sheep has been used as a model of human fetal development and responses to pathophysiologic stimuli. This is due to the unique amenability of the unanesthetized fetal sheep to the surgical placement and maintenance of catheters and electrodes, allowing repetitive blood sampling, substance injection, recording of bioelectrical activity, application of electric stimulation, and in vivo organ imaging. Recently, there has been growing interest in the pleiotropic effects of vagus nerve stimulation (VNS) on various organ systems such as innate immunity and inflammation, and metabolism. There is no approach to study this in utero and corresponding physiological understanding is scarce. NEW METHOD: Based on our previous presentation of a stable chronically instrumented unanesthetized fetal sheep model, here we describe the surgical instrumentation procedure allowing successful implantation of a cervical uni- or bilateral VNS probe with or without vagotomy. RESULTS: In a cohort of 68 animals, we present the changes in blood gas, metabolic, and inflammatory markers during the postoperative period. We detail the design of a VNS probe which also allows recording from the fetal nerve. We also present an example of fetal vagus electroneurogram (VENG) recorded from the VNS probe and an analytical approach to the data. COMPARISON WITH EXISTING METHODS: This method represents the first implementation of fetal VENG/VNS in a large pregnant mammalian organism. CONCLUSIONS: This study describes a new surgical procedure allowing to record and manipulate chronically fetal vagus nerve activity in an animal model of human pregnancy.


Assuntos
Fenômenos Fisiológicos do Sistema Nervoso , Estimulação do Nervo Vago , Animais , Modelos Animais de Doenças , Feminino , Feto , Gravidez , Ovinos , Nervo Vago
3.
J Am Vet Med Assoc ; 250(9): 1036-1041, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28414605

RESUMO

CASE DESCRIPTION A 4-hour-old 6.3-kg (13.9-lb) female alpaca cria was evaluated because of severe respiratory distress and difficulty nursing since birth. CLINICAL FINDINGS The cria had open-mouth breathing and cyanotic membranes, with no airflow evident from either nostril. Supplemental oxygen was delivered, and the patient was anesthetized and intubated orotracheally; a CT evaluation of the head confirmed bilateral membranous obstruction of the nasal cavities, consistent with complete bilateral choanal atresia. TREATMENT AND OUTCOME Choanal atresia was treated with an endoscopically assisted balloon-dilation technique, and temporary tracheostomy was performed. Stenosis recurred, requiring revision of the repair and intranasal stent placement 3 days after the first surgery. The tracheostomy tube was removed the next day. Complications during hospitalization included mucoid obstruction of the tracheostomy tube, granulation tissue development in the trachea near the tracheostomy site, mucoid stent obstruction, aspiration pneumonia, and presumed partial failure of passive transfer of immunity. The stents were removed 2 weeks after admission, and the cria was discharged 3 days later. The owner was advised that the animal should not be bred. At last follow-up 3 years later, the alpaca was doing well. CLINICAL RELEVANCE Surgical treatment with a balloon-dilation technique and placement of nasal stents with endoscopic guidance were curative in this neonatal alpaca with bilateral membranous choanal atresia. Computed tomography was useful to determine the nature of the atresia and aid surgical planning. Because a genetic component is likely, owners should be advised to prevent affected animals from breeding.


Assuntos
Camelídeos Americanos , Atresia das Cóanas/veterinária , Insuficiência Respiratória/veterinária , Animais , Animais Recém-Nascidos , Atresia das Cóanas/complicações , Atresia das Cóanas/diagnóstico , Atresia das Cóanas/diagnóstico por imagem , Atresia das Cóanas/cirurgia , Diagnóstico Diferencial , Feminino , Insuficiência Respiratória/etiologia , Stents , Tomografia Computadorizada por Raios X/veterinária
4.
J Am Vet Med Assoc ; 246(9): 976-81, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25875668

RESUMO

OBJECTIVE: To evaluate the effects of a constant rate infusion of remifentanil, alone or in combination with ketamine, in healthy cats anesthetized with isoflurane. DESIGN: Randomized, controlled, clinical trial. ANIMALS: 23 cats undergoing elective ovariohysterectomy. PROCEDURES: Cats were premedicated with acepromazine and morphine; anesthesia was induced with propofol and maintained with isoflurane. Cats were given constant rate infusions of remifentanil (20 µg/kg/h [9 µg/lb/h], IV; n = 8), remifentanil and ketamine (0.5 mg/kg [0.23 mg/lb], then 1.8 mg/kg/h [0.82 mg/lb/h], IV; 7), or crystalloid fluids (8). The anesthesiologist was blinded to treatment group, end-tidal isoflurane concentration, and vaporizer setting. Heart rate, systolic arterial blood pressure, respiratory rate, end-tidal partial pressure of CO2, temperature, and end-tidal isoflurane concentration were monitored; recovery scores were assigned. RESULTS: There were no significant differences among treatment groups with respect to age, body weight, surgery time, anesthesia time, time to extubation, recovery score, or cardiorespiratory variables. End-tidal isoflurane concentration was significantly reduced in cats given remifentanil and ketamine (mean ± SD, 0.63 ± 0.4%), compared with concentration in cats given crystalloid fluids (1.22 ± 0.5%) but not compared with concentration in cats given remifentanil alone (1.03 ± 0.4%). Compared with cats given crystalloid fluids, mean isoflurane requirement was reduced by 48.3% in cats given remifentanil-ketamine and 15.6% in cats given remifentanil alone. CONCLUSIONS AND CLINICAL RELEVANCE: At the dosages administered, a constant rate infusion of remifentanil-ketamine resulted in a significant decrease in the isoflurane requirement in healthy cats undergoing ovariohysterectomy. However, significant differences in cardiovascular variables were not observed among treatment groups.


Assuntos
Gatos , Histerectomia/veterinária , Isoflurano/farmacologia , Ketamina/farmacologia , Ovariectomia/veterinária , Piperidinas/farmacologia , Anestésicos Dissociativos/administração & dosagem , Anestésicos Dissociativos/farmacologia , Anestésicos Inalatórios/administração & dosagem , Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/administração & dosagem , Anestésicos Intravenosos/farmacologia , Animais , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Isoflurano/administração & dosagem , Ketamina/administração & dosagem , Piperidinas/administração & dosagem , Remifentanil
5.
Res Vet Sci ; 97(1): 111-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24924217

RESUMO

Two non-invasive blood pressure (NIBP) devices (oscillometry and Doppler) were compared to invasive blood pressure using a Bland-Altman analysis, in anesthetized and conscious dogs. When considering the systolic arterial pressure only during general anesthesia, both NIBP devices slightly underestimated the systolic arterial blood pressure however the precision and the limits of agreement for the Doppler were of a greater magnitude. This indicates a worse clinical performance by the Doppler. The performance of both NIBP devices deteriorated as measured in conscious animals. In general, for the oscillometric device, determination of invasive diastolic and mean arterial pressures was better than the invasive systolic arterial pressure. Overall, the oscillometric device satisfied more of the criteria set by the American College of Veterinary Internal Medicine consensus statement. Based upon these results, the oscillometric device is more reliable than the Doppler in the determination of blood pressure in healthy medium to large breed dogs.


Assuntos
Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Oscilometria/veterinária , Ultrassonografia Doppler/veterinária , Anestesia/veterinária , Animais , Determinação da Pressão Arterial/instrumentação , Cães , Oscilometria/instrumentação , Ultrassonografia Doppler/instrumentação
6.
Crit Care Med ; 35(9): 2101-9, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17581486

RESUMO

OBJECTIVE: To test the hypothesis that low-volume resuscitation with hemoglobin glutamer-200 improves hemodynamic function and tissue oxygenation, whereas arginine vasopressin resuscitation improves blood pressures more than low-volume saline or hemoglobin glutamer infusion but compromises systemic and muscle blood flow and oxygenation. DESIGN: Randomized laboratory investigation. SETTING: University research facility. SUBJECTS: Nineteen dogs. INTERVENTIONS: Dogs were instrumented to determine heart rate; arterial, central venous, pulmonary arterial, and pulmonary arterial occlusion pressures; cardiac output; and quadriceps muscle blood flow and oxygen tension (PMo2). Total and plasma hemoglobin, oxygen content, lactate, pH, standard base excess, and arginine vasopressin levels were determined, and systemic oxygen delivery (Do2I) and extraction ratio were calculated. Measurements were made before and 30 mins following hemorrhage. Dogs were resuscitated over 60 mins with saline (8.5 mL/kg), arginine vasopressin (0.4 IU/kg bolus plus 0.08 IU x kg x min), or 1:1 diluted hemoglobin glutamer-200. Recordings were then repeated. Subsequently, animals received 30 mL/kg shed blood (60 mL x kg x hr), and recordings were repeated immediately and 1 hr later. MEASUREMENTS AND MAIN RESULTS: Hemorrhage ( approximately 52 mL/kg) caused characteristic changes in hemodynamic, hematologic, systemic PMo2, and acid-base variables. Saline resuscitation increased both Do2I and muscle perfusion by 42% and 51%, while arginine vasopressin treatment reduced heart rate by 31% and increased mean arterial pressure by 22% but not cardiac output, Do2I, or muscle blood flow, resulting in a further decrease of PMo2 by 68% and worse metabolic acidosis. Hemoglobin glutamer-200 infusion caused systemic and pulmonary vasoconstriction, however, without deterioration of cardiac output, Do2I, muscle blood flow, or PMo2 despite lack of oxygen content increase. Blood transfusion restored most variables. CONCLUSIONS: Low-volume crystalloid or hemoglobin glutamer-200 resuscitation posthemorrhage may improve (but not restore) macro- and microvascular functions and tissue oxygenation, while arginine vasopressin infusion may only improve blood pressures and result in lower overall systemic perfusion compared with low-volume saline or hemoglobin glutamer-200 treatment and worsening of anaerobic conditions in skeletal muscle.


Assuntos
Arginina Vasopressina/administração & dosagem , Hemoglobinas/administração & dosagem , Músculos/irrigação sanguínea , Ressuscitação/métodos , Choque Hemorrágico/terapia , Animais , Circulação Sanguínea/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Modelos Animais de Doenças , Cães , Feminino , Frequência Cardíaca/efeitos dos fármacos , Masculino , Oxigênio/metabolismo , Distribuição Aleatória , Choque Hemorrágico/fisiopatologia
7.
Vet Anaesth Analg ; 33(5): 281-95, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16916350

RESUMO

OBJECTIVE: To compare the accuracy of a 3rd (Dolphin Voyager) versus 1st generation pulse oximeter (Nellcor N-180). STUDY DESIGN: Prospective laboratory investigation. ANIMALS: Eight adult dogs. METHODS: In anesthetized dogs, arterial oxygen saturation (SpO(2)) was recorded simultaneously with each pulse oximeter. The oxygen fraction in inspired gas (FiO(2)) was successively reduced from 1.00 to 0.09, with re-saturation (FiO(2) 0.40) after each breathe-down step. After each 3-minute FiO(2) plateau, SpO(2) and pulse rate (PR) were compared with the fractional arterial saturation (SaO(2)) and PR determined by co-oximetry and invasive blood pressure monitoring, respectively. Data analysis included Bland-Altman (B-A) plots, Lin's concordance correlation factor (rho(c)), and linear regression models. RESULTS: Over a SaO(2) range of 33-99%, the overall bias (mean SpO(2) - SaO(2)), precision (SD of bias), and accuracy (A(rms)) for the Dolphin Voyager and Nellcor N-180 were 4.3%, 4.4%, and 6.1%, and 3.2%, 3.0%, and 4.3%, respectively. Bias increased at SaO(2) < 90%, more so with the Dolphin Voyager (from 1.6% to 8.6%) than Nellcor N-180 (from 3.2% to 4.5%). The SpO(2) readings correlated significantly with SaO(2) for both the Dolphin Voyager (rho(c) = 0.94) and Nellcor N-180 (rho(c) = 0.97) (p < 0.001). Regarding PR, bias, precision, and accuracy (A(rms)) for the Dolphin Voyager and Nellcor N-180 were -0.5, 4.6, and 4.6 and 1.38, 4.3, and 4.5 beats minute(-1), respectively. Significant correlation existed between pulse oximeter and directly measured PR (Dolphin Voyager: rho(c) = 0.98; Nellcor N-180: rho(c) = 0.99) (p < 0.001). CONCLUSIONS AND CLINICAL RELEVANCE: In anesthetized dogs with adequate hemodynamic function, both instruments record SaO(2) relatively accurately over a wide range of normal saturation values. However, there is an increasing overestimation at SaO(2) < 90%, particularly with the Dolphin Voyager, indicating that 3rd generation pulse oximeters may not perform better than older instruments. The 5.4-fold increase in bias with the Dolphin Voyager at SaO(2) < 90% stresses the importance of a 93-94% SpO(2) threshold to ensure an arterial saturation of >or=90%. In contrast, PR monitoring with both devices is very reliable.


Assuntos
Cães/fisiologia , Frequência Cardíaca/fisiologia , Oximetria/instrumentação , Oximetria/veterinária , Oxigênio/sangue , Anestesia , Anestesia por Inalação/veterinária , Animais , Feminino , Masculino , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa