Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
Surg Endosc ; 38(6): 3212-3222, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38637339

RESUMO

INTRODUCTION: Intraoperative indocyanine green fluorescence angiography (ICGFA) aims to reduce colorectal anastomotic complications. However, signal interpretation is inconsistent and confounded by patient physiology and system behaviours. Here, we demonstrate a proof of concept of a novel clinical and computational method for patient calibrated quantitative ICGFA (QICGFA) bowel transection recommendation. METHODS: Patients undergoing elective colorectal resection had colonic ICGFA both immediately after operative commencement prior to any dissection and again, as usual, just before anastomotic construction. Video recordings of both ICGFA acquisitions were blindly quantified post hoc across selected colonic regions of interest (ROIs) using tracking-quantification software and computationally compared with satisfactory perfusion assumed in second time-point ROIs, demonstrating 85% agreement with baseline ICGFA. ROI quantification outputs detailing projected perfusion sufficiency-insufficiency zones were compared to the actual surgeon-selected transection/anastomotic construction site for left/right-sided resections, respectively. Anastomotic outcomes were recorded, and tissue lactate was also measured in the devascularised colonic segment in a subgroup of patients. The novel perfusion zone projections were developed as full-screen recommendations via overlay heatmaps. RESULTS: No patient suffered intra- or early postoperative anastomotic complications. Following computational development (n = 14) the software recommended zone (ROI) contained the expert surgical site of transection in almost all cases (Jaccard similarity index 0.91) of the nine patient validation series. Previously published ICGFA time-series milestone descriptors correlated moderately well, but lactate measurements did not. High resolution augmented reality heatmaps presenting recommendations from all pixels of the bowel ICGFA were generated for all cases. CONCLUSIONS: By benchmarking to the patient's own baseline perfusion, this novel QICGFA method could allow the deployment of algorithmic personalised NIR bowel transection point recommendation in a way fitting existing clinical workflow.


Assuntos
Anastomose Cirúrgica , Angiofluoresceinografia , Verde de Indocianina , Humanos , Feminino , Masculino , Anastomose Cirúrgica/métodos , Idoso , Angiofluoresceinografia/métodos , Pessoa de Meia-Idade , Calibragem , Colo/cirurgia , Colo/irrigação sanguínea , Estudo de Prova de Conceito , Colectomia/métodos , Monitorização Intraoperatória/métodos , Neoplasias Colorretais/cirurgia
2.
Surg Endosc ; 38(1): 426-436, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37985488

RESUMO

INTRODUCTION: Gas leaks polluting the operating room are common in laparoscopy. Studies defining methods for sensitive leak characterisation and mechanical mitigation in real world settings are, however, lacking. METHODS: Mobile optical gas imagers (both a miniaturised Schlieren system and sensitive tripod-mounted near-infrared carbon dioxide camera (GF343, FLIR)) prospectively defined trocar-related gas leaks occurring either spontaneously or with instrumentation during planned laparoscopic surgery at three hospitals. A boutique Matlab-based analyser using sequential frame subtraction categorised leaks (class 0-no observable leak; class 1-marginally detectable leak; class 2-short-lived plume; class 3-energetic, turbulent jet). Concurrently, the usefulness of a novel vacuum-ring device (LeakTrap™, Palliare, Ireland) designed as a universal adjunct for existing standard laparoscopic ports at both abdominal wall and port valve level was determined similarly in a phase I/11 clinical trial along with the device's useability through procedural observation and surgeon questionnaire. RESULTS: With ethical and regulatory approval, 40 typical patients (mean age 58.6 years, 20 males) undergoing planned laparoscopic cholecystectomy (n = 36) and hernia repair (n = 4) were studied comprising both control (n = 20) and intervention (n = 20) cohorts. Dual optical gas imaging was successfully performed across all procedures with minimal impact on procedural flow. In total, 1643 trocar instrumentations were examined, 819 in the control group (mean 41 trocar instrumentations/procedure) and 824 in the intervention group (mean 41.2 trocar instrumentations/procedure). Gas leaks were detected during 948(62.6%) visualised trocar instrumentations (in 129-7.8%-the imaging was obscured). 14.8% (110/742) and 60% (445/742) of leaks in control patients were class 0 and 3, respectively, versus 59.1% (456/770) and 8.7% (67/772) in the interventional group (class 3 v non-class 3, p < 0.0001, χ2). The Leaktrap proved surgically acceptable without significant workflow disruption. CONCLUSION: Laparoscopic gas leaks can be sensitively detected and consistently, effectively mitigated using straightforward available-now technology with most impact on the commonest, highest energy instrument exchange leaks.


Assuntos
Parede Abdominal , Colecistectomia Laparoscópica , Laparoscopia , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Colecistectomia Laparoscópica/métodos , Parede Abdominal/cirurgia , Instrumentos Cirúrgicos
3.
Surg Endosc ; 38(3): 1306-1315, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38110792

RESUMO

AIM/BACKGROUND: Intra-operative colonic perfusion assessment via indocyanine green fluorescence angiography (ICGFA) aims to address malperfusion-related anastomotic complications; however, its interpretation suffers interuser variability (IUV), especially early in ICGFA experience. This work assesses the impact of a protocol developed for both operator-based judgement and computational development on interpretation consistency, focusing on senior surgeons yet to start using ICGFA. METHODS: Experienced and junior gastrointestinal surgeons were invited to complete an ICGFA-experience questionnaire. They subsequently interpreted nine operative ICGFA videos regarding perfusion sufficiency of a surgically prepared distal colon during laparoscopic anterior resection by indicating their preferred site of proximal transection using an online annotation platform (mindstamp.com). Six ICGFA videos had been prepared with a clinical standardisation protocol controlling camera and patient positioning of which three each had monochrome near infrared (NIR) and overlay display. Three others were non-standardised controls with synchronous NIR and overlay picture-in-picture display. Differences in transection level between different cohorts were assessed for intraclass correlation coefficient (ICC) via ImageJ and IBM SPSS. RESULTS: 58 clinicians (12 ICGFA experts, 46 ICGFA inexperienced of whom 23 were either finished or within one year of finishing training and 23 were junior trainees) participated as per power calculations. 63% felt that ICGFA should be routinely deployed with 57% believing interpretative competence requires 11-50 cases. Transection level concordance was generally good (ICC = 0.869) across all videos and levels of expertise (0.833-0.915). However, poor agreement was evident with the standardised protocol videos for overlay presentation (0.208-0.345). Similarly, poor agreement was seen for the monochrome display (0.392-0.517), except for those who were trained but ICG inexperienced (0.877) although even here agreement was less than with unstandardised videos (0.943). CONCLUSION: Colorectal ICGFA acquisition and display standardisation impacts IUV with this specific protocol tending to diminish surgeon interpretation consistency. ICGFA video recording for computational development may require dedicated protocols.


Assuntos
Neoplasias Colorretais , Cirurgia Colorretal , Humanos , Verde de Indocianina , Angiofluoresceinografia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Fístula Anastomótica , Cirurgia Colorretal/métodos , Anastomose Cirúrgica/métodos
4.
Langenbecks Arch Surg ; 409(1): 170, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822883

RESUMO

PURPOSE: Perioperative decision making for large (> 2 cm) rectal polyps with ambiguous features is complex. The most common intraprocedural assessment is clinician judgement alone while radiological and endoscopic biopsy can provide periprocedural detail. Fluorescence-augmented machine learning (FA-ML) methods may optimise local treatment strategy. METHODS: Surgeons of varying grades, all performing colonoscopies independently, were asked to visually judge endoscopic videos of large benign and early-stage malignant (potentially suitable for local excision) rectal lesions on an interactive video platform (Mindstamp) with results compared with and between final pathology, radiology and a novel FA-ML classifier. Statistical analyses of data used Fleiss Multi-rater Kappa scoring, Spearman Coefficient and Frequency tables. RESULTS: Thirty-two surgeons judged 14 ambiguous polyp videos (7 benign, 7 malignant). In all cancers, initial endoscopic biopsy had yielded false-negative results. Five of each lesion type had had a pre-excision MRI with a 60% false-positive malignancy prediction in benign lesions and a 60% over-staging and 40% equivocal rate in cancers. Average clinical visual cancer judgement accuracy was 49% (with only 'fair' inter-rater agreement), many reporting uncertainty and higher reported decision confidence did not correspond to higher accuracy. This compared to 86% ML accuracy. Size was misjudged visually by a mean of 20% with polyp size underestimated in 4/6 and overestimated in 2/6. Subjective narratives regarding decision-making requested for 7/14 lesions revealed wide rationale variation between participants. CONCLUSION: Current available clinical means of ambiguous rectal lesion assessment is suboptimal with wide inter-observer variation. Fluorescence based AI augmentation may advance this field via objective, explainable ML methods.


Assuntos
Colonoscopia , Neoplasias Retais , Humanos , Neoplasias Retais/patologia , Neoplasias Retais/cirurgia , Neoplasias Retais/diagnóstico por imagem , Pólipos Intestinais/patologia , Pólipos Intestinais/cirurgia , Aprendizado de Máquina , Masculino , Fluorescência , Feminino , Variações Dependentes do Observador
5.
Surg Technol Int ; 442024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38629713

RESUMO

Transanal minimally invasive surgery (TAMIS) is an effective procedure that plays an important role in the care of patients with significant rectal neoplasia and polyps including early-stage cancers. However, it is perhaps underutilised and under threat from both advanced flexible endoscopic procedures and proceduralists (who often act as gatekeepers for referral to colorectal surgeons), as well as from robotic surgery proponents. TAMIS advocates can learn and adopt practice insights from both these fields and incorporate available technological innovations building on the huge accomplishments already delivered in this area. Evolved practice through technology has the potential to offset current limitations regarding technical constraints and indeed patient selection (via artificial intelligence methods). Potential target areas for advances are considered in this review from different perspectives: (1) Access (2) Insufflation (3) Visualisation (4) Disease Characterization in situ, and (5) Tissue Handling and Suturing. While a bundle approach may be most useful, the advances for each component are potentially useful in their own right and could be applied without depending on the other practices detailed so that more accurate (and perhaps even numerically more) TAMIS procedures can be performed globally to improve patient care.

6.
Dis Colon Rectum ; 66(12): e1265-e1268, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37787571

RESUMO

BACKGROUND: The constrained access associated with transanal minimally invasive surgery has led surgeons to deploy robotic-assisted platforms to offset inherent maneuverability limitations and, perhaps, skills deficits. IMPACT OF INNOVATION: A handheld, powered 5-mm lightweighted laparoendoscopic electromechanical digital device (HandX, HumanXtensions, Israel) with hardware and software components that convert surgical hand movements precisely to the instrument's articulating tip and enable robotic transanal minimally invasive surgery with full tip roticulation for hook diathermy and suturing. TECHNOLOGY, MATERIALS, AND METHODS: After bench and biomedical model training, HandX was used in 3 transanal minimally invasive surgery procedures (2 male patients and 1 female patient, mean age 66.3 years). The rectal lesions averaged 30 mm in maximum dimension and were located posteriorly (n = 2) and laterally (n = 1) a mean of 3 cm from the anal verge. Standard transanal minimally invasive surgery setup and instrumentation (Gelport Path, Applied Medical with Airseal, and Conmed) were used, adding the HandX device for circumferential lesion marking and hemostatic full-thickness excision as well as defect suturing where appropriate. PRELIMINARY RESULTS: All procedures were completed without undue prolongation (operating times <1 hour) despite nuisance hemorrhoidal bleeding in 1 patient. All lesions were fully excised, with 2 being T1 cancers and 1 tubulovillous adenoma with high-grade dysplasia. All patients were discharged within 48 hours postoperatively (1 experienced secondary hemorrhage on postoperative day 5). CONCLUSIONS AND FUTURE DIRECTIONS: HandX capably facilitated endoscopic robot-like instrument movement for transanal minimally invasive surgery without disrupting workflows. With time dedicated to instrument understanding and training, HandX increased dexterity with a small operating room footprint and may offer greater cost-effectiveness than other platforms.


Assuntos
Adenoma , Neoplasias Retais , Cirurgia Endoscópica Transanal , Humanos , Masculino , Feminino , Idoso , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Reto/cirurgia , Cirurgia Endoscópica Transanal/métodos , Canal Anal/cirurgia , Canal Anal/patologia , Adenoma/patologia , Procedimentos Cirúrgicos Minimamente Invasivos
7.
Surg Endosc ; 37(8): 6361-6370, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36894810

RESUMO

INTRODUCTION: Indocyanine green (ICG) quantification and assessment by machine learning (ML) could discriminate tissue types through perfusion characterisation, including delineation of malignancy. Here, we detail the important challenges overcome before effective clinical validation of such capability in a prospective patient series of quantitative fluorescence angiograms regarding primary and secondary colorectal neoplasia. METHODS: ICG perfusion videos from 50 patients (37 with benign (13) and malignant (24) rectal tumours and 13 with colorectal liver metastases) of between 2- and 15-min duration following intravenously administered ICG were formally studied (clinicaltrials.gov: NCT04220242). Video quality with respect to interpretative ML reliability was studied observing practical, technical and technological aspects of fluorescence signal acquisition. Investigated parameters included ICG dosing and administration, distance-intensity fluorescent signal variation, tissue and camera movement (including real-time camera tracking) as well as sampling issues with user-selected digital tissue biopsy. Attenuating strategies for the identified problems were developed, applied and evaluated. ML methods to classify extracted data, including datasets with interrupted time-series lengths with inference simulated data were also evaluated. RESULTS: Definable, remediable challenges arose across both rectal and liver cohorts. Varying ICG dose by tissue type was identified as an important feature of real-time fluorescence quantification. Multi-region sampling within a lesion mitigated representation issues whilst distance-intensity relationships, as well as movement-instability issues, were demonstrated and ameliorated with post-processing techniques including normalisation and smoothing of extracted time-fluorescence curves. ML methods (automated feature extraction and classification) enabled ML algorithms glean excellent pathological categorisation results (AUC-ROC > 0.9, 37 rectal lesions) with imputation proving a robust method of compensation for interrupted time-series data with duration discrepancies. CONCLUSION: Purposeful clinical and data-processing protocols enable powerful pathological characterisation with existing clinical systems. Video analysis as shown can inform iterative and definitive clinical validation studies on how to close the translation gap between research applications and real-world, real-time clinical utility.


Assuntos
Neoplasias Colorretais , Verde de Indocianina , Humanos , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Computadores , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Surg Endosc ; 36(9): 7047-7055, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35503476

RESUMO

INTRODUCTION: The advent of the COVID-19 pandemic led to recommendations aimed at minimizing the risk of gas leaks at laparoscopy. As this has continuing relevance including regarding operating room pollution, we empirically quantified carbon dioxide (CO2) leak jet velocity (important for particle propulsion) occurring with different instruments inserted into differing trocars repeated across a range of intra-abdominal pressures (IAPs) and modern insufflators in an experimental model. METHOD: Laparoscopic gas plume leak velocity (metres/second) was computationally enumerated from schlieren optical flow videography on a porcine cadaveric laparoscopic model with IAPs of 4-5, 7-8, 12-15 and 24-25 mmHg (repeated with 5 different insufflators) during simulated operative use of laparoscopic clip appliers, scissors, energy device, camera and staplers as well as Veres needle (positive control) and trocar obturator (negative control) in fresh 5 mm and 12 mm ports. RESULTS: Close-fitting solid instruments (i.e. cameras and obturators) demonstrated slower gas leak velocities in both the 5 mm and 12 mm ports (p = 0.02 and less than 0.001) when compared to slimmer instruments, however, hollow instrument designs were seen to defy this pattern with the endoscopic linear stapler visibly inducing multiple rapid jests even when compared to similarly sized clip appliers (p = 0.03). However, on a per device basis the operating instrumentation displayed plume speeds which did not vary significantly when challenged with varying post size, IAP and a range of insufflators. CONCLUSION: In general, surgeon's selection of instrument, port or pressure does not usefully mitigate trocar CO2 leak velocity. Instead better trocar design is needed, helped by a fuller understanding of trocar valve mechanics via computational fluid dynamics informed by relevant surgical modelling.


Assuntos
COVID-19 , Insuflação , Laparoscopia , Animais , Dióxido de Carbono , Humanos , Laparoscopia/efeitos adversos , Pandemias , Suínos
9.
Surg Endosc ; 36(12): 8764-8773, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35543771

RESUMO

INTRODUCTION: Indocyanine green fluorescence angiography (ICGFA) is commonly used in colorectal anastomotic practice with limited pre-training. Recent work has shown that there is considerable inconsistency in signal interpretation between surgeons with minimal or no experience versus those consciously invested in mastery of the technique. Here, we deconstruct the fluorescence signal patterns of expert-annotated surgical ICGFA videos to understand better their correlation and combine this with structured interviews to ascertain whether such interpretative capability is conscious or unconscious. METHODS: For fluorescence signal analysis, expert-annotated ICGFA videos (n = 24) were quantitatively interrogated using a boutique intensity tracker (IBM Research) to generate signal time plots. Such fluorescence intensity data were examined for inter-observer correlation (Intraclass Correlation Coefficients, ICC) at specific curve milestones: the maximum fluorescence signal (Fmax), the times to both achieve this maximum (Tmax), as well as half this maximum (T1/2max) and the ratio between these (T1/2/Tmax). Formal tele-interview with contributing experts (n = 6) was conducted with the narrative transcripts being thematically mapped, plotted, and qualitatively analyzed. RESULTS: Correlation by mathematical measures was excellent (ICC0.9-1.0) for Fmax, Tmax, and T1/2max (0.95, 0.938, and 0.925, respectively) and moderate (0.5-0.75) for T1/2/Tmax (0.729). While all experts narrated a deliberate viewing strategy, their specific dynamic signal appreciation differed in the manner of description. CONCLUSION: Expert ICGFA users demonstrate high correlation in mathematical measures of their signal interpretation although do so tacitly. Computational quantification of expert behavior can help develop the necessary lexicon and training sets as well as computer vision methodology to better exploit ICGFA technology.


Assuntos
Neoplasias Colorretais , Verde de Indocianina , Humanos , Angiofluoresceinografia/métodos , Anastomose Cirúrgica/métodos , Reto/cirurgia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Fístula Anastomótica
10.
Surg Endosc ; 36(10): 7369-7375, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35199204

RESUMO

INTRODUCTION: Assessing bowel viability can be challenging during acute surgical procedures, especially regarding mesenteric ischaemia. Intraoperative fluorescence angiography (FA) may be a valuable tool for the surgeon to determine whether bowel resection is necessary and to define the most appropriate resection margins. The aim of this study is to report on FA use in the acute setting and to judge its impact on intraoperative decision making. MATERIALS AND METHODS: This is a multi-centre, retrospective case series of patients undergoing emergency abdominal surgery between February 2016 and 2021 in three general/colorectal units where intraoperative FA was performed to assess bowel viability. Primary endpoint was change of management after the FA assessment. RESULTS: A total of 93 patients (50 males, 66.6 ± 19.2 years, ASA score ≥ III in 85%) were identified and studied. Initial surgical approach was laparotomy in 66 (71%) patients and laparoscopy in 27 (29% and seven, 26% conversions). The most common aetiologies were mesenteric ischaemia (n = 42, 45%) and adhesional/herniae-related strangulation (n = 41, 44%). In 50 patients a bowel resection was performed. Overall rates of anastomosis after resection, reoperation and 30-day mortality were 48% (n = 24/50, one leak), 12% and 18%, respectively. FA changed management in 27 (29%) patients. In four patients (4% overall), resection was avoided and in 21 (23%) extra bowel length was preserved (median 50 cm of bowel saved, IQR 28-98) although three patients developed further ischaemia. FA prompted extended resection (median of 20 cm, IQR 10-50 extra bowel) in six (6%) patients. CONCLUSION: Intraoperative use of FA impacts surgical decisions regarding bowel resection for intestinal ischaemia, potentially enabling bowel preservation in approximately one out of four patients. Prospective studies are needed to optimize the best use of this technology for this indication and to determine standards for the interpretation of FA images and the potential subsequent need for second-look surgeries.


Assuntos
Verde de Indocianina , Isquemia Mesentérica , Anastomose Cirúrgica/métodos , Angiofluoresceinografia/métodos , Humanos , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Masculino , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/etiologia , Isquemia Mesentérica/cirurgia , Estudos Retrospectivos
11.
Dis Esophagus ; 35(11)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-35428892

RESUMO

Indocyanine Green Fluorescence Angiography (ICGFA) has been deployed to tackle malperfusion-related anastomotic complications. This study assesses variations in operator interpretation of pre-anastomotic ICGFA inflow in the gastric conduit. Utilizing an innovative online interactive multimedia platform (Mindstamp), esophageal surgeons completed a baseline opinion-practice questionnaire and proceeded to interpret, and then digitally assign, a distal transection point on 8 ICGFA videos of esophageal resections (6 Ivor Lewis, 2 McKeown). Annotations regarding gastric conduit transection by ICGFA were compared between expert users versus non-expert participants using ImageJ to delineate longitudinal distances with Shapiro Wilk and t-tests to ascertain significance. Expert versus non-expert correlation was assessed via Intraclass Correlation Coefficients (ICC). Thirty participants (13 consultants, 6 ICGFA experts) completed the study in all aspects. Of these, a high majority (29 participants) stated ICGFA should be used routinely with most (21, including 5/6 experts) stating that 11-50 cases were needed for competency in interpretation. Among users, there were wide variations in dosing (0.05-3 mg/kg) and practice impact. Agreement regarding ICGFA video interpretation concerning transection level among experts was 'moderate' (ICC = 0.717) overall but 'good' (ICC = 0.871) among seven videos with Leave One Out (LOO) exclusion of the video with highest disagreement. Agreement among non-experts was moderate (ICC = 0.641) overall and in every subgroup including among consultants (ICC = 0.626). Experts choose levels that preserved more gastric conduit length versus non-experts in all but one video (P = 0.02). Considerable variability exists with ICGFA interpretation and indeed impact. Even adept users may be challenged in specific cases. Standardized training and/or computerized quantitative fluorescence may help better usage.


Assuntos
Neoplasias Esofágicas , Esofagectomia , Humanos , Esofagectomia/efeitos adversos , Verde de Indocianina , Fístula Anastomótica/etiologia , Angiofluoresceinografia , Anastomose Cirúrgica/efeitos adversos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Perfusão/efeitos adversos
12.
Surgeon ; 20(3): e7-e12, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33962892

RESUMO

BACKGROUND: Surgery is a major component of health-care provision. Operative intervention often employs minimally invasive approaches incorporating digital cameras creating a 'digital twin' of both intracorporeal appearances and operative performance. Video recordings provide richer detail than the traditional operative note and can couple with advanced computer technology to unlock new analytic capabilities capable of driving surgical advancement via quality improvement initiatives and new technology design. Surgical video is however an under-utilized technology resource, in part, because ownership along with broader issues including purpose, privacy, confidentiality, copyright and inclusion in outputs have been poorly considered using outdated categorisation. METHOD: A first principles perspective on operative video classification as a useful public interest resource enshrining fundamental stakeholder (patients, physicians, institutions, industry and society) rights, roles and responsibilities. RESULT: A facility of noble purpose, understandable to all, for fair, accountable, safe and transparent access to large volumes of anonymised surgical videos of intracorporeal operations that enables advances through cross-disciplinary research is proposed. Technology can be exploited to protect all relevant parties respecting both citizen data-rights and the special status doctor-patient relationship. Through general consensus, the capability can be understood, established and iterated to perfection. CONCLUSION: Overall we argue that new and specific classification of surgical video enables responsible curation and serves the public good better than the current model. Rather than being thought of as a bicycle where discrete ownership is ascribed, such data are better viewed as being more like a park, a regulated amenity we should preserve for better human life.


Assuntos
Big Data , Relações Médico-Paciente , Ciclismo , Humanos , Melhoria de Qualidade , Gravação em Vídeo
13.
Int J Colorectal Dis ; 36(5): 1065-1068, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33184703

RESUMO

BACKGROUND: There is concern regarding bioaerosols from patients having procedures impacting surgical team safety. As pathogens and pollutants have been found in surgical smoke, we examined the potential for aerosol escape during transanal minimally invasive surgery (TAMIS) which may be particularly important given the presence of faecal contamination in the operative workspace and the specifics of its access platforms. METHODS: Both qualitative (thermographic imaging) and quantificative (particle counting) methods were used to assess for aerosol release during TAMIS in comparison to laparoscopic operations of similar duration and equipment both at times of surgical dissection and without. TAMIS was performed using a Gelport Path Device (Applied Medical) and Airseal insufflation with valveless trocar (ConMed). RESULTS: Significant carbon dioxide (CO2) escapes during TAMIS carrying with it considerable numbers of particles. In general, particle counts were low prior to tissue dissection phases of the operation but increased substantially (25 × 106/m3 or over 40× background counts) during hook cautery dissection. The majority of particles were in the 0.3-0.5 micron range (where counts were increased relative to background between 42× and 65) with the highest relative increase versus background in the 0.5-1.0 micron range. Particle counts < 5 were substantially greater during the TAMIS procedure versus laparoscopic procedures (a laparoscopic-assisted parastomal hernia repair and laparoscopic cholecystectomy) employing similar tools. CONCLUSIONS: Considerable amounts of particle-rich aerosols escape during TAMIS procedures. Although pathogens are not proven to definitely spread to healthcare staff by such material nebulisation, N95/FFP2 masks, at a minimum, seem prudent while other methods evolve to eliminate this risk.


Assuntos
Laparoscopia , Neoplasias Retais , Cirurgia Endoscópica Transanal , Canal Anal , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Neoplasias Retais/cirurgia
14.
Surg Endosc ; 35(12): 7074-7081, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33398567

RESUMO

INTRODUCTION: Despite increasing endorsement of near-infrared perfusion assessment using indocyanine green (ICG) during colorectal surgery, little work has yet been done regarding learning curve and interobserver variation most especially on surgical video reflective of real-world usage. METHODS: Surgeons with established expertise in ICG usage were invited to participate in the study along with others without such experience including trainees. All participants completed an opinion questionnaire and interpreted video presentations of fluorescence angiograms in a variety of colorectal case scenarios. An interactive video platform (Mindstamp) enabled dynamic annotation. Statistical analysis of data was performed using Kruskal-Wallis and Mann-Whitney testing as well as Intraclass Correlation Coefficients and Fleiss Multi-rater Kappa Scoring. RESULTS: Forty participants (six experts) completed questionnaire data and provided judgement of 14 videos (nine showing proximal colonic transection site perfusion, four showing completed anastomoses and one an acutely strangulated bowel). 70% felt > 10 cases were needed for competency in use with the majority of experts advocating > 50 (p < 0.05). Overall agreement among experts was "good" for videos showing colonic transection perfusion (versus "moderate" among in-experts) with experts clustering more distally. In contrast, there was no interpretation concordance among experts or in-experts when judging ICG perfusion sufficiency on a yes/no basis. CONCLUSION: Significant experience is recommended before reliance on ICG perfusion angiograms. ICG fluorescence assessment is prone to variable interpretation and influenced by experience and, perhaps, knowledge of preassessment operative steps suggesting a role for objective flow analysis with artificial intelligence methods as the next phase of this technology.


Assuntos
Cirurgia Colorretal , Verde de Indocianina , Anastomose Cirúrgica , Fístula Anastomótica , Inteligência Artificial , Humanos , Perfusão , Imagem de Perfusão
15.
Surg Endosc ; 35(3): 1362-1369, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32253556

RESUMO

INTRODUCTION: There has been a constant increase in the number of published surgical videos with preference for open-access sources, but the proportion of videos undergoing peer-review prior to publication has markedly decreased, raising questions over quality of the educational content presented. The aim of this study was the development and validation of a standard framework for the appraisal of surgical videos submitted for presentation and publication, the LAParoscopic surgery Video Educational GuidelineS (LAP-VEGaS) video assessment tool. METHODS: An international committee identified items for inclusion in the LAP-VEGaS video assessment tool and finalised the marking score utilising Delphi methodology. The tool was finally validated by anonymous evaluation of selected videos by a group of validators not involved in the tool development. RESULTS: 9 items were included in the LAP-VEGaS video assessment tool, with every item scoring from 0 (item not presented in the video) to 2 (item extensively presented in the video), with a total marking score ranging from 0 to 18. The LAP-VEGaS video assessment tool resulted highly accurate in identifying and selecting videos for acceptance for conference presentation and publication, with high level of internal consistency and generalisability. CONCLUSIONS: We propose that peer review in adherence to the LAP-VEGaS video assessment tool could enhance the overall quality of published video outputs.


Assuntos
Lista de Checagem , Avaliação Educacional , Guias como Assunto , Laparoscopia/normas , Gravação em Vídeo/normas , Humanos , Reprodutibilidade dos Testes , Inquéritos e Questionários
16.
World J Surg Oncol ; 19(1): 74, 2021 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-33714275

RESUMO

BACKGROUND: Inflammatory markers are measured following colorectal surgery to detect postoperative complications. However, the association of these markers preoperatively with subsequent postoperative course has not yet been usefully studied. AIM: The aim of this study is to assess the ability of preoperative C-reactive protein (CRP) and other inflammatory marker measurements in the prediction of postoperative morbidity after elective colorectal surgery. METHODS: This is a retrospective study which catalogs 218 patients undergoing elective, potentially curative surgery for colorectal neoplasia. Preoperative laboratory results of the full blood count (FBC), C-reactive protein (CRP) and carcinoembryonic antigen (CEA) were recorded. Multivariable analysis was performed to examine preoperative variables against 30-day postoperative complications by type and grade (Clavien-Dindo (CD)), adjusting for age, sex, BMI, smoking status, medical history, open versus laparoscopic operation, and tumor characteristics. RESULTS: Elevated preoperative CRP (≥ 5 mg/L) was significantly predictive of all-cause mortality, with an OR of 17.0 (p < 0.001) and was the strongest factor to predict a CD morbidity grade ≥ 3 (OR 41.9, p < 0.001). Other factors predictive of CD morbidity grade ≥ 3 included smoking, elevated preoperative platelet count and elevated preoperative neutrophil-lymphocyte ratio (OR 15.6, 8.6, and 6.3 respectively, all p < 0.05). CRP values above 5.5 mg/L were indicative of all-cause morbidity (AUC = 0.871), and values above 17.5 mg/L predicted severe complications (AUC = 0.934). CONCLUSIONS: Elevated preoperative CRP predicts increased postoperative morbidity in this patient cohort. The results herein aid risk and resource stratification and encourage preoperative assessment of inflammatory propensity besides simple sepsis exclusion.


Assuntos
Proteína C-Reativa , Neoplasias Colorretais , Proteína C-Reativa/análise , Neoplasias Colorretais/cirurgia , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Retrospectivos
17.
Surg Technol Int ; 39: 34-37, 2021 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-34647309

RESUMO

INTRODUCTION: The risk of unknowingly disseminating leiomyosarcoma by morcellation in women undergoing laparoscopic hysterectomy has massively impacted gynaecological practice. Here, we present the results of an in vitro assessment of a novel protection system developed to mitigate this hazard. METHODS: The Tissue Containment System for Manual Morcellation (Guardenia™, Advanced Surgical Concepts, Wicklow, Ireland) is an evolved wound protection/specimen extraction guarded bag system compatible with any 12mm trocar. Device use was assessed by device-naïve gynaecological and general surgeon volunteers (providing expert and inexpert morcellation cohorts, respectively) on a bench model consisting of biological tissue in a custom-built moulded rig with camera control after the operators were instructed in its use. RESULTS: Twenty surgeons (10 gynaecologists/10 general surgeons, median duration of practice experience: 8 years, median annual number of laparoscopic operative procedures: 150 and 80, respectively) completed the user assessment. All subjects understood and correctly performed each step; i.e., (i) placement of the bag through the trocar, (ii) specimen bagging, (iii) incision extension (range 25-60 mm) after tethering the bag through the port, (iv) insertion of the device guard through the mouth of the bag after trocar removal, and (v) sufficient tissue morcellation within the bag to enable complete specimen removal (mean specimen weight 390g, range 201-1800g). There was 100% bag integrity by water-leak testing following use, despite scalpel contact with the guard in 14/20 cases (70%). CONCLUSION: Among first-time clinical users, this novel device enabled complete containment of morcellation debris and removal of a laparoscopic specimen, which would support further submission for regulatory approval.


Assuntos
Laparoscopia , Morcelação , Miomectomia Uterina , Neoplasias Uterinas , Feminino , Humanos , Histerectomia/efeitos adversos , Morcelação/efeitos adversos , Neoplasias Uterinas/cirurgia
18.
Surg Innov ; 28(6): 768-775, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33634722

RESUMO

In this article, we provide an evidence-based primer of current tools and evolving concepts in the area of intraprocedural artificial intelligence (AI) methods in colonoscopy and laparoscopy as a 'procedure companion', with specific focus on colorectal cancer recognition and characterisation. These interventions are both likely beneficiaries from an impending rapid phase in technical and technological evolution. The domains where AI is most likely to impact are explored as well as the methodological pitfalls pertaining to AI methods. Such issues include the need for large volumes of data to train AI systems, questions surrounding false positive rates, explainability and interpretability as well as recent concerns surrounding instabilities in current deep learning (DL) models. The area of biophysics-inspired models, a potential remedy to some of these pitfalls, is explored as it could allow our understanding of the fundamental physiological differences between tissue types to be exploited in real time with the help of computer-assisted interpretation. Right now, such models can include data collected from dynamic fluorescence imaging in surgery to characterise lesions by their biology reducing the number of cases needed to build a reliable and interpretable classification system. Furthermore, instead of focussing on image-by-image analysis, such systems could analyse in a continuous fashion, more akin to how we view procedures in real life and make decisions in a manner more comparable to human decision-making. Synergistical approaches can ensure AI methods usefully embed within practice thus safeguarding against collapse of this exciting field of investigation as another 'boom and bust' cycle of AI endeavour.


Assuntos
Neoplasias Colorretais , Laparoscopia , Inteligência Artificial , Colonoscopia , Neoplasias Colorretais/diagnóstico , Endoscopia Gastrointestinal , Humanos
20.
Surgeon ; 17(6): 334-339, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30420320

RESUMO

BACKGROUND: Surgical trainers consider laparoscopic videos as a useful teaching aid to maximize trainees' learning and skill development given the backdrop of time constraints and productivity demands. Aim of this study is to assess the current use of laparoscopic videos amongst surgical trainees in the United Kingdom. METHODS: A steering committee of 15 experienced laparoscopic trainers from 8 countries developed a survey on the use of laparoscopic videos by surgical trainees. The survey items were finalized by discussion through e-mails, teleconferences, and face-to-face meetings and a finalised questionnaire was distributed amongst surgical trainees in the United Kingdom. RESULTS: 92 trainees were invited and 75 returned the questionnaire (81.5%). 86.7% of the trainees routinely watched online surgical videos and the more frequently used websites were Youtube.com and Websurg.com. Trainees require laparoscopic videos to have supplementary educational content such as English commentary (90.7%) and use of snapshots (93.3%) and diagrams (86.7%). Position of the patient and trocars, indication for surgery, preoperative data and postoperative outcomes are required characteristics of laparoscopic videos. 29 trainees (38.7%) do not record the laparoscopic procedures they perform, despite the majority of them recognising the usefulness of routine video-recording for training purposes (78.7%). CONCLUSIONS: Surgical trainees consider videos a useful adjunct in laparoscopic surgery training, with preference for open access sources. Trainees value highly informative videos with supplementary educational content.


Assuntos
Instrução por Computador , Educação a Distância , Laparoscopia/educação , Gravação em Vídeo , Competência Clínica , Currículo , Feminino , Humanos , Masculino , Reino Unido
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa