Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Int J Legal Med ; 132(5): 1469-1475, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29349700

RESUMO

INTRODUCTION: Electronic control with the CEW (conducted electrical weapon) has gained widespread acceptance as the preferred force option due to its significant injury reduction. However, a CEW application does stress the human body. In the case of the CEW, the human body response is similar to the challenge of physical exercise combined with emotional stress over a very short time interval. There has been concern whether the tension of the skeletal-muscle system together with the emotional stress of being exposed to the effects of a CEW, can lead to severe metabolic dysfunction. METHODS: A systematic and careful search of the MedLine database was performed to find publications describing pathophysiological effects of CEWs. Additional publications were collected through a manual search of reference lists in retrieved articles. After preliminary exclusions, we carefully reviewed the remaining publications and found 24 papers reporting prospective human clinical research data on adrenergic, ventilation, or metabolic effects. Where there were multiple studies on the same endpoints, we performed meta-analyses. RESULTS: A CEW exposure provides a clinically insignificant increase in heart rate (7.5 BPM) and a drop in both systolic and diastolic blood pressure. Alpha-amylase goes down but cortisol levels increase-both epinephrine and norepinephrine levels are increased by levels similar to mild exercise. A CEW exposure increases ventilation but does not appear to interfere with gas exchange. Lactate is increased slightly while the pH is decreased slightly with changes equivalent to mild exercise. The lactate and pH changes appear quickly and do not appear to be affected by increasing the exposure duration from 5 to 30 s. CONCLUSIONS: Thorough review and meta-analyses show that electrical weapon exposures have mixed and mild adrenergic effects. Ventilation is increased and there are metabolic changes similar to mild exercise.


Assuntos
Adrenérgicos/farmacologia , Epinefrina/sangue , Norepinefrina/sangue , Armas , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Eletricidade , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/sangue , Estudos Prospectivos
2.
Herz ; 40(3): 402-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25963172

RESUMO

Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is a rare cardiomyopathy associated with life-threatening arrhythmias and an increased risk of sudden cardiac death. In addition to mutations in desmosomal genes, environmental factors such as exercise and sport have been implicated in the pathogenesis of the disease. Recent studies have shown that exercise may be associated with adverse outcomes in patients with ARVD/C. On the basis of current evidence, patients with ARVD/C are recommended to limit exercise irrespective of their mutation status. Some studies have suggested the presence of an entirely acquired form of the disease caused by exercise, which has been dubbed "exercise-induced ARVD/C."


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/genética , Morte Súbita Cardíaca/prevenção & controle , Desmossomos/genética , Programas de Rastreamento/métodos , Esportes , Predisposição Genética para Doença/genética , Alemanha , Humanos , Testes Obrigatórios/métodos , Mutação , Exame Físico/métodos
3.
Eur Heart J Cardiovasc Imaging ; 24(1): 98-107, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-35152298

RESUMO

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is characterized by ventricular dysfunction and ventricular arrhythmias (VA). Adequate arrhythmic risk assessment is important to prevent sudden cardiac death. We aimed to study the incremental value of strain by feature-tracking cardiac magnetic resonance imaging (FT-CMR) in predicting sustained VA in ARVC patients. METHODS AND RESULTS: CMR images of 132 ARVC patients (43% male, 40.6 ± 16.0 years) without prior VA were analysed for global and regional right and left ventricular (RV, LV) strain. Primary outcome was sustained VA during follow-up. We performed multivariable regression assessing strain, in combination with (i) RV ejection fraction (EF); (ii) LVEF; and (iii) the ARVC risk calculator. False discovery rate adjusted P-values were given to correct for multiple comparisons and c-statistics were calculated for each model. During 4.3 (2.0-7.9) years of follow-up, 19% of patients experienced sustained VA. Compared to patients without VA, those with VA had significantly reduced RV longitudinal (P ≤ 0.03) and LV circumferential (P ≤ 0.04) strain. In addition, patients with VA had significantly reduced biventricular EF (P ≤ 0.02). After correcting for RVEF, LVEF, and the ARVC risk calculator separately in multivariable analysis, both RV and LV strain lost their significance [hazard ratio 1.03-1.18, P > 0.05]. Likewise, while strain improved the c-statistic in combination with RVEF, LVEF, and the ARVC risk calculator separately, this did not reach statistical significance (P ≥ 0.18). CONCLUSION: Both RV longitudinal and LV circumferential strain are reduced in ARVC patients with sustained VA during follow-up. However, strain does not have incremental value over RVEF, LVEF, and the ARVC VA risk calculator.


Assuntos
Displasia Arritmogênica Ventricular Direita , Humanos , Masculino , Feminino , Prognóstico , Volume Sistólico , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
4.
J Clin Invest ; 102(7): 1279-85, 1998 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-9769319

RESUMO

Nitric oxide (NO) synthesized within mammalian sinoatrial cells has been shown to participate in cholinergic control of heart rate (HR). However, it is not known whether NO synthesized within neurons plays a role in HR regulation. HR dynamics were measured in 24 wild-type (WT) mice and 24 mice in which the gene for neuronal NO synthase (nNOS) was absent (nNOS-/- mice). Mean HR and HR variability were compared in subsets of these animals at baseline, after parasympathetic blockade with atropine (0.5 mg/kg i.p.), after beta-adrenergic blockade with propranolol (1 mg/kg i.p.), and after combined autonomic blockade. Other animals underwent pressor challenge with phenylephrine (3 mg/kg i.p.) after beta-adrenergic blockade to test for a baroreflex-mediated cardioinhibitory response. The latter experiments were then repeated after inactivation of inhibitory G proteins with pertussis toxin (PTX) (30 microgram/kg i.p.). At baseline, nNOS-/- mice had higher mean HR (711+/-8 vs. 650+/-8 bpm, P = 0.0004) and lower HR variance (424+/-70 vs. 1,112+/-174 bpm2, P = 0.001) compared with WT mice. In nNOS-/- mice, atropine administration led to a much smaller change in mean HR (-2+/-9 vs. 49+/-5 bpm, P = 0.0008) and in HR variance (64+/-24 vs. -903+/-295 bpm2, P = 0.02) than in WT mice. In contrast, propranolol administration and combined autonomic blockade led to similar changes in mean HR between the two groups. After beta-adrenergic blockade, phenylephrine injection elicited a fall in mean HR and rise in HR variance in WT mice that was partially attenuated after treatment with PTX. The response to pressor challenge in nNOS-/- mice before PTX administration was similar to that in WT mice. However, PTX-treated nNOS-/- mice had a dramatically attenuated response to phenylephrine. These findings suggest that the absence of nNOS activity leads to reduced baseline parasympathetic tone, but does not prevent baroreflex-mediated cardioinhibition unless inhibitory G proteins are also inactivated. Thus, neuronally derived NO and cardiac inhibitory G protein activity serve as parallel pathways to mediate autonomic slowing of heart rate in the mouse.


Assuntos
Pressão Sanguínea/fisiologia , Subunidades alfa Gi-Go de Proteínas de Ligação ao GTP/metabolismo , Frequência Cardíaca/fisiologia , Óxido Nítrico Sintase/metabolismo , Animais , Atropina/farmacologia , Sistema Nervoso Autônomo/efeitos dos fármacos , Sistema Nervoso Autônomo/fisiologia , Barorreflexo/efeitos dos fármacos , Barorreflexo/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Eletrocardiografia/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Homeostase , Camundongos , Camundongos Knockout , Modelos Cardiovasculares , Óxido Nítrico Sintase/deficiência , Óxido Nítrico Sintase/genética , Óxido Nítrico Sintase Tipo II , Fenilefrina/farmacologia , Propranolol/farmacologia , Transdução de Sinais/fisiologia
5.
Circulation ; 101(11): 1237-42, 2000 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-10725281

RESUMO

BACKGROUND: Certain genetic mutations associated with hypertrophic cardiomyopathy (HCM) carry an increased risk of sudden death. QT variability identifies patients at a high risk for sudden death from ventricular arrhythmias. We tested whether patients with HCM caused by beta-myosin heavy-chain (beta-MHC) gene mutations exhibit labile ventricular repolarization using beat-to-beat QT variability analysis. METHODS AND RESULTS: We measured the QT variability index and heart rate-QT interval coherence from Holter monitor recordings in 36 patients with HCM caused by known beta-MHC gene mutations and in 26 age- and sex-matched controls. There were 7 distinct beta-MHC gene mutations in these 36 patients; 9 patients had HCM caused by the malignant Arg(403)Gln mutation and 8 patients had HCM caused by the more benign Leu(908)Val mutation. The QT variability index was higher in HCM patients than in controls (-1.24+/-0.17 versus -1. 58+/-0.38, P<0.01), and the greatest abnormality was detected in patients with the Arg(403)Gln mutation (-0.99+/-0.49 versus -1. 46+/-0.43 in controls, P<0.05). In keeping with this finding, coherence was lower for the entire HCM group than for controls (P<0. 001). Coherence was also significantly lower in patients with the Arg(403)Gln mutation compared with controls (P<0.05). CONCLUSIONS: These findings suggest that (1) patients with HCM caused by beta-MHC gene mutations exhibit labile repolarization quantified by QT variability analysis and, hence, may be more at risk for sudden death from ventricular arrhythmias, and (2) indices of QT variability may be particularly abnormal in patients with beta-MHC gene mutations that are associated with a poor prognosis.


Assuntos
Cardiomiopatia Hipertrófica/genética , Mutação , Cadeias Pesadas de Miosina/genética , Adulto , Sequência de Aminoácidos/genética , Criança , Eletrocardiografia , Eletrofisiologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Isoformas de Proteínas/genética , Valores de Referência , Fatores de Tempo
6.
Circulation ; 104(6): 723-8, 2001 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-11489782

RESUMO

BACKGROUND: There is increasing evidence that defibrillation from prolonged ventricular fibrillation (VF) before CPR decreases survival. It remains unclear, however, whether harmful effects are due primarily to initial countershock of ischemic myocardium or to resultant postdefibrillation rhythms (ie, pulseless electrical activity [PEA] or asystole). METHODS AND RESULTS: We induced 15 dogs into 12 minutes of VF and randomized them to 3 groups. Group 1 was defibrillated at 12 minutes and then administered advanced cardiac life support (ACLS); group 2 was allowed to remain in VF and was subsequently defibrillated after 4 minutes of ACLS; group 3 was defibrillated at 12 minutes, electrically refibrillated, and then defibrillated after 4 minutes of ACLS. All group 1 and 3 animals were defibrillated into PEA/asystole at 12 minutes. After 4 minutes of ACLS, group 2 and 3 animals were effectively defibrillated into sinus rhythm. The extension of VF in group 2 and 3 subjects paradoxically resulted in shorter mean resuscitation times (251+/-15 and 245+/-7 seconds, respectively, versus 459+/-66 seconds for group 1; P<0.05) and improved 1-hour survival (10 of 10 group 2 and 3 dogs versus 1 of 5 group 1 dogs; Fisher's exact, P<0.005) compared with more conservatively managed group 1 subjects. CONCLUSIONS: Precountershock CPR during VF appears more conducive to resuscitation than CPR during postcountershock PEA or asystole. The intentional induction of VF may prove useful in the management of PEA and asystolic arrests.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca/fisiopatologia , Fibrilação Ventricular/fisiopatologia , Animais , Cães , Cardioversão Elétrica , Estimulação Elétrica , Parada Cardíaca/prevenção & controle , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Fatores de Tempo , Disfunção Ventricular Esquerda/fisiopatologia , Fibrilação Ventricular/terapia
7.
Circulation ; 102(6): 698-705, 2000 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-10931812

RESUMO

BACKGROUND: The purpose of this study was to describe a system and method for creating, visualizing, and monitoring cardiac radiofrequency ablation (RFA) therapy during magnetic resonance imaging (MRI). METHODS AND RESULTS: RFA was performed in the right ventricular apex of 6 healthy mongrel dogs with a custom 7F nonmagnetic ablation catheter (4-mm electrode) in a newly developed real-time interactive cardiac MRI system. Catheters were positioned to intracardiac targets by use of an MRI fluoroscopy sequence, and ablated tissue was imaged with T2-weighted fast spin-echo and contrast-enhanced T1-weighted gradient-echo sequences. Lesion size by MRI was determined and compared with measurements at gross and histopathological examination. Ablated areas of myocardium appeared as hyperintense regions directly adjacent to the catheter tip and could be detected 2 minutes after RF delivery. Lesions reached maximum size approximately 5 minutes after ablation, whereas lesion signal intensity increased linearly with time but then reached a plateau at 12.2+/-2.1 minutes. Lesion size by MR correlated well with actual postmortem lesion size and histological necrosis area (55.4+/-7.2 versus 49.7+/-5.9 mm(2), r=0.958, P<0.05). CONCLUSIONS: RFA can be performed in vivo in a new real-time interactive cardiac MRI system. The spatial and temporal extent of cardiac lesions can be visualized and monitored by T2- and T1-weighted imaging, and MRI lesion size agrees well with actual postmortem lesion size. MRI-guided RFA may be a useful approach to help facilitate anatomic lesion placement and to provide insight into the biophysical effects of new ablation techniques and technologies.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Imageamento por Ressonância Magnética , Miocárdio/patologia , Animais , Cadáver , Cães , Necrose , Período Pós-Operatório , Fatores de Tempo
8.
Circulation ; 101(3): 280-8, 2000 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-10645924

RESUMO

BACKGROUND: This study evaluated the cost-effectiveness of catheter ablation therapy versus amiodarone for treating ventricular tachycardia (VT) in patients with structural heart disease. The analysis used a societal perspective for a hypothetical cohort of VT patients with implantable cardioverter-defibrillators, who were experiencing frequent shocks. METHODS AND RESULTS: We calculated incremental cost-effectiveness of ablation relative to amiodarone over 5 years after treatment initiation. Event probabilities were from the Chilli randomized clinical trial (Chilli Cooled Ablation System, Cardiac Pathways Corporation, Sunnyvale, Calif), the literature, and a consensus panel. Costs were from 1998 national Medicare reimbursement schedules. Quality-of-life weights (utilities) were estimated using an established preference measurement technique. In a hypothetical cohort of 10 000 patients, 5-year costs were higher for patients undergoing ablation compared with amiodarone therapy ($21 795 versus $19 075). Ablation also produced a greater increase in quality of life (2.78 versus 2.65 quality-adjusted life-years [QALYs]). This yielded a cost-effectiveness ratio of $20 923 per QALY gained for ablation compared with amiodarone. Results were relatively insensitive to assumptions about ablation success and durability. In less severe patients with good ejection fractions who suffer their first VT episode, the incremental cost-effectiveness ratio was $6028 per QALY gained. These cost-effectiveness ratios are within the range generally thought to warrant technology adoption. CONCLUSIONS: This study demonstrates that, from a societal perspective, catheter ablation appears to be a cost-effective alternative to amiodarone for treating VT patients.


Assuntos
Ablação por Cateter/economia , Taquicardia Ventricular/cirurgia , Análise Custo-Benefício , Humanos
9.
Circulation ; 101(25): 2968-74, 2000 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-10869271

RESUMO

BACKGROUND: Survival after prolonged ventricular fibrillation (VF) appears severely limited by 2 major factors: (1) low defibrillation success rates and (2) persistent post-countershock myocardial dysfunction. Biphasic (BP) waveforms may prove capable of favorably modifying these limitations. However, they have not been rigorously tested against monophasic (MP) waveforms in clinical models of external defibrillation, particularly where rescue from prolonged VF is the general rule. METHODS AND RESULTS: We randomized 26 dogs to external countershocks with either MP or BP waveforms. Hemodynamics were assessed after shocks applied during sinus rhythm, after brief VF (>10 seconds), and after resuscitation from prolonged VF (>10 minutes). Short-term differences in percent change in left ventricular +dP/dt(max) (MP -16+/-28%, BP +9.1+/-24%; P=0.03) and left ventricular -dP/dt(max) (MP -37+/-26%, BP -18+/-20%; P=0.05) were present after rescue from brief VF, with BP animals exhibiting less countershock-induced dysfunction. After prolonged VF, the BP group had lower mean defibrillation thresholds (107+/-57 versus 172+/-88 J for MP, P=0.04) and significantly shorter resuscitation times (397+/-73.7 versus 488+/-74.3 seconds for MP, P=0.03). CONCLUSIONS: External defibrillation is more efficacious with BP countershocks than with MP countershocks. The lower defibrillation thresholds and shorter resuscitation times associated with BP waveform defibrillation may improve survival after prolonged VF arrest.


Assuntos
Cardioversão Elétrica/métodos , Ressuscitação , Fibrilação Ventricular/terapia , Animais , Pressão Sanguínea , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Circulação Coronária , Cães , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/normas , Coração/fisiopatologia , Parada Cardíaca/terapia , Fatores de Tempo
10.
Circulation ; 100(8): 807-12, 1999 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-10458715

RESUMO

BACKGROUND: Hypertensive left ventricular hypertrophy with supranormal systolic ejection and distal cavity obliteration (HHCO) can result in debilitating exertional fatigue and dyspnea. Dual-chamber pacing with ventricular preactivation generates discoordinate contraction, which can limit cavity obliteration and thereby increase potential ejection reserve. Accordingly, we hypothesized that pacing may improve exercise tolerance long-term in this syndrome. METHODS AND RESULTS: Dual-chamber pacemakers were implanted in 9 patients with exertional dyspnea caused by HHCO. Intrinsic atrial rate was sensed, and ventricular preactivation was achieved by shortening the atrial-ventricular delay. Pacing was on or off for successive 3-month periods (randomized, double-blind, crossover design), followed by 6 additional pacing-on months. Metabolic exercise testing, quality-of-life assessment, and rest and dobutamine-stress echocardiographic/Doppler data were obtained. After 3 months of pacing-on, exercise duration rose from 324+/-133 to 588+/-238 s (mean+/-SD; P=0.001, with 7 of 9 patients improving >/=30%), and maximal oxygen consumption increased from 13.6+/-2.9 to 16.7+/-3.3 mL of O(2). min(-1). kg(-1) (P<0.02). Both parameters were little changed from baseline during the pacing-off period. Improved exercise capacity persisted at 1-year follow-up. Clinical symptoms and activities of daily living improved during the pacing-on period and stayed improved at 1 year, but they were little changed during the pacing-off period. Despite similar basal values, stroke volume (P<0.001) and cardiac output (P<0.02) increased with dobutamine stimulation 2 to 3 times more after 1 year of follow-up as compared with baseline. CONCLUSIONS: Long-term dual-chamber pacing can improve exercise capacity, cardiac reserve, clinical symptoms, and activities of daily living in patients with HHCO. This therapy may provide a novel alternative for patients in whom traditional pharmacological treatment proves inadequate.


Assuntos
Estimulação Cardíaca Artificial/métodos , Hipertensão/complicações , Hipertrofia Ventricular Esquerda/terapia , Débito Cardíaco , Estudos Cross-Over , Método Duplo-Cego , Ecocardiografia Doppler , Tolerância ao Exercício , Feminino , Seguimentos , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Volume Sistólico , Função Ventricular Esquerda
11.
Circulation ; 99(2): 262-70, 1999 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-9892593

RESUMO

BACKGROUND: The purpose of this study was to evaluate the safety and efficacy of a temperature-controlled radiofrequency catheter ablation system. METHODS AND RESULTS: The patient population included 1050 patients who had undergone ablation of atrioventricular nodal reentrant tachycardia (AVNRT), an accessory pathway (AP), or the atrioventricular junction (AVJ). Ablation was successful in 996 patients. The probability of success was highest among patients who had undergone ablation of the AVJ, lowest in patients who had undergone ablation of an AP, and in between for patients who had undergone ablation of AVNRT. A major complication occurred in 32 patients. Four variables predicted ablation success (AVJ, AVNRT, or left free wall AP ablation and an experienced center). Four factors predicted arrhythmia recurrence (right free wall, posteroseptal, septal, and multiple APs). Two variables predicted development of a complication (structural heart disease and the presence of multiple targets), and 3 variables predicted an increased risk of death (heart disease, lower ejection fraction, and AVJ ablation). CONCLUSIONS: These findings may serve as a guide to clinicians considering therapeutic options in patients who are candidates for ablation.


Assuntos
Nó Atrioventricular/cirurgia , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Criança , Pré-Escolar , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Segurança , Resultado do Tratamento
12.
J Am Coll Cardiol ; 16(6): 1415-9, 1990 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2229794

RESUMO

The feasibility of outpatient electrophysiologic testing was examined by reviewing 100 consecutive outpatient tests performed in 95 patients. Seventy-one of the patients (75%) had no underlying heart disease. The electrophysiologic tests were performed to evaluate supraventricular tachycardias (n = 47), nonsustained ventricular tachycardia (n = 20), unexplained syncope (n = 21), palpitation (n = 9) or intermittent heart block (n = 2). A mean of 2.8 +/- 0.5 6F electrode catheters were inserted through a femoral vein. An electrode catheter was inserted into a subclavian or internal jugular vein in 28 tests and a 5F cannula was inserted into a femoral artery to monitor the blood pressure in 20 tests. The results of 61 tests (61%) were abnormal. Patients were monitored for a mean of 3.8 +/- 1.2 h after the procedure and then discharged. No complications occurred. For cost analysis a subgroup of 60 of these patients was matched for age, gender, heart disease and indication for electrophysiologic testing with a group of 60 patients who underwent electrophysiologic testing as inpatients. Physicians' fees for the two groups were similar; however, the mean hospital charge was $5,845 +/- 3,763 for the inpatient group compared with only $2,120 +/- 1,244 for the outpatient group (p less than 0.001). Thus, outpatient electrophysiologic testing is feasible and safe and results in substantial cost savings in patients without life-threatening arrhythmias.


Assuntos
Assistência Ambulatorial/economia , Arritmias Cardíacas/fisiopatologia , Eletrofisiologia/economia , Adulto , Arritmias Cardíacas/tratamento farmacológico , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/economia , Estudos de Coortes , Custos e Análise de Custo , Eletrofisiologia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/economia , Monitorização Fisiológica/métodos , Estudos Retrospectivos
13.
J Am Coll Cardiol ; 16(3): 666-73, 1990 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2387940

RESUMO

Concomitant use of a pacemaker and an automatic implantable cardioverter-defibrillator (AICD) is common. Seventeen percent of patients receiving an AICD at The Johns Hopkins Hospital also had a permanent pacemaker implanted before (16 patients), at the same time as (2 patients) or after (12 patients) AICD implantation. Four types of interactions were noted: 1) transient failure to sense or capture immediately after AICD discharge (seven patients); 2) oversensing of the pacemaker stimulus by the AICD, leading to double counting (one patient); 3) AICD failure to sense ventricular fibrillation resulting from pacemaker stimulus oversensing (three patients, one only at high asynchronous output); and 4) pacemaker reprogramming caused by AICD discharge (three patients). No clinical sequelae of these interactions were noted during follow-up study. Thus, potentially adverse clinical interactions are common and routine screening is recommended. With proper attention to lead placements and programming of the devices, clinical consequences of these interactions can be avoided.


Assuntos
Arritmias Cardíacas/terapia , Cardioversão Elétrica/instrumentação , Marca-Passo Artificial , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Eletrodos Implantados , Falha de Equipamento , Seguimentos , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
14.
J Am Coll Cardiol ; 22(1): 80-4, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8509568

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the inducibility of atrial flutter in patients with atrioventricular (AV) node reentrant tachycardia and to determine the effect of radio-frequency ablation of the slow AV node pathway on the inducibility of atrial flutter. BACKGROUND: Studies have shown that both AV node reentrant tachycardia and atrial flutter are reentrant arrhythmias having an area of slow conduction that is located in the low posterior right atrium near the ostium of the coronary sinus. METHODS: Ninety-one patients were prospectively evaluated using a standardized atrial pacing protocol. Three groups of patients were analyzed: 42 patients with inducible AV node reentrant tachycardia, 13 with a history of spontaneous atrial flutter and 36 control patients. A subgroup of 34 patients with AV node reentrant tachycardia who underwent successful radiofrequency ablation of the slow AV node pathway underwent atrial pacing again after ablation. RESULTS: Atrial flutter was more frequently inducible in patients with AV node reentrant tachycardia (88%) and in those with a history of atrial flutter (92%) than in control patients (36%) (p = 0.0001). There were no differences between the patient groups with respect to atrial effective refractory period, P wave duration or PA interval at the His position. Among the 34 patients with AV node reentrant tachycardia who underwent atrial pacing before and after radiofrequency ablation, there were 30 with atrial flutter and 4 with atrial fibrillation before ablation and 29 with atrial flutter and 5 with atrial fibrillation after ablation (p = NS). There was no difference in the duration of the induced atrial flutter before and after ablation. The mean atrial flutter cycle length before ablation (206 +/- 22 ms) was not different from that after ablation (196 +/- 20 ms) (p = NS). CONCLUSIONS: There is a strong association between AV node reentrant tachycardia and inducible atrial flutter, suggesting that there may be a common area of perinodal atrium participating in the two tachycardia circuits. However, radiofrequency ablation of the slow pathway of the AV node reentrant tachycardia circuit does not influence the inducibility of atrial flutter.


Assuntos
Flutter Atrial/etiologia , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Adulto , Idoso , Flutter Atrial/fisiopatologia , Nó Atrioventricular/cirurgia , Estimulação Cardíaca Artificial , Estudos de Casos e Controles , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
15.
J Am Coll Cardiol ; 17(3): 678-89, 1991 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-1993788

RESUMO

Fifteen consecutive patients with drug-refractory, recurrent, sustained, monomorphic ventricular tachycardia and a history of remote myocardial infarction underwent catheter ablation of ventricular tachycardia. Shocks of 100 to 300 J were delivered to sites at which pacing during ventricular tachycardia resulted in concealed entrainment, in which the ventricular tachycardia accelerated to the pacing rate, there was a long stimulus to QRS interval and there was no change in the configuration of the QRS complex during pacing at several rates compared with the configuration during ventricular tachycardia, thus identifying a zone of slow conduction in the reentrant circuit. Concealed entrainment was demonstrated in nine (60%) of 15 patients, and the stimulus to QRS intervals were 90 to 400 ms. At sites of concealed entrainment, the endocardial activation time relative to the QRS complex during ventricular tachycardia ranged from -125 to +50 ms, the timing of the local electrogram relative to the QRS complex was the same during entrainment as during ventricular tachycardia and the pace map during sinus rhythm was discordant with that of the ventricular tachycardia in seven patients. In the six patients in whom a site of concealed entrainment could not be identified, the target site for ablation was selected on the basis of identification of an isolated mid-diastolic potential, activation mapping and pace mapping. The mean (+/- SD) cumulative number of joules delivered to the target site was 306 +/- 140. A successful long-term clinical outcome was achieved in 9 of the 15 patients (mean follow-up 20 +/- 7 months). The clinical success rate was the same whether the target site was selected on the basis of concealed entrainment (five of nine, 56%) or on the basis of the other mapping techniques (four of six, 67%). In conclusion, the responses to pacing suggest that sites at which there is concealed entrainment may be located within a zone of slow conduction in the ventricular tachycardia reentry circuit, although not necessarily in an area critical for the maintenance of reentry. The long-term clinical efficacy of catheter ablation targeted to sites of concealed entrainment is about 60%, similar to the results achieved when conventional mapping techniques are used.


Assuntos
Infarto do Miocárdio/complicações , Taquicardia/fisiopatologia , Taquicardia/cirurgia , Idoso , Estimulação Cardíaca Artificial , Eletrocardiografia , Eletrocirurgia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia/etiologia
16.
J Am Coll Cardiol ; 18(7): 1761-6, 1991 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1960327

RESUMO

The purpose of this study was to evaluate the serial changes in T wave configuration in patients undergoing successful radiofrequency catheter ablation of accessory atrioventricular (AV) connections. Twenty-nine consecutive patients with overt preexcitation and 16 patients with a concealed accessory atrioventricular (AV) connection were included. An electrocardiogram (ECG) was recorded before ablation and 15 min, 1 or 2 days and 1 and 3 months after ablation. Postablation T wave abnormalities occurred in 22 (76%) of the 29 patients who had overt pre-excitation but in none of the 16 patients with a concealed accessory AV connection. The T wave abnormalities were not related to myocardial necrosis or echocardiographic abnormalities. The ECG location and severity of T wave changes were dependent on the accessory AV connection location and degree of baseline pre-excitation, respectively. Fourteen of 19 patients with a posteriorly located AV connection (left, right or septal) had T wave inversion or flattening in the inferior leads and 3 patients had precordial T wave peaking. Two patients with an anteroseptal AV accessory connection had both inferior T wave inversion or flattening and precordial T wave peaking. Among seven patients with a manifest left lateral accessory AV connection, two had lateral T wave inversion or flattening and two had precordial T wave peaking. There was 95% concordance between the directional change of the T wave after ablation and the direction of the delta wave on the baseline ECG.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Arritmias Cardíacas/diagnóstico , Nó Atrioventricular/cirurgia , Eletrocardiografia , Eletrocoagulação/efeitos adversos , Ondas de Rádio , Adulto , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Eletrocoagulação/normas , Eletrofisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
17.
J Am Coll Cardiol ; 21(3): 567-70, 1993 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-8436736

RESUMO

OBJECTIVES: The purpose of this study was to evaluate prospectively the safety, feasibility and cost of performing radiofrequency catheter ablation of accessory atrioventricular (AV) connections on an outpatient basis in 137 cases. BACKGROUND: The efficacy and low complication rate of radiofrequency ablation as performed in the hospital suggested that it might be feasible to perform it on an outpatient basis. METHODS: In 100 cases (73%) performed between September 1, 1991 and April 20, 1992, patients met criteria for treatment as outpatients. Reasons for exclusion were age < 13 or > 70 years (4), anteroseptal location of the accessory AV connection (5 patients), obesity (> 30% of ideal body weight) (4 patients) or clinical indication for hospitalization (24 patients). Patients with only venous punctures had a recovery period of 3 h and those with arterial punctures had a recovery period of 6 h. There were 63 men and 32 women (5 patients underwent two ablation procedures > 1 month apart), with a mean age +/- SD of 36 +/- 13 years. The pathway was left-sided in 67 cases and right-sided or posteroseptal in 33. RESULTS: The procedure was successful in 97 of 100 cases, with a mean procedure duration of 99 +/- 42 min. In 70 cases the patient was discharged the day of ablation, and in 30 cases the patient required a short (< or = 18-h) overnight stay because the procedure was completed too late in the day for recovery in the outpatient facility. The mean duration of observation was 4.8 +/- 1.5 h for outpatients and 15 +/- 1.4 h for patients who underwent overnight hospitalization. At follow-up study, two patients had a clinically significant complication; both had a femoral artery pseudoaneurysm detected > or = 1 week after the procedure and both required surgical repair. Thirty consecutive patients (22 outpatients and 8 hospitalized overnight) undergoing catheter ablation after January 1, 1992 were chosen for a cost analysis. The mean cost of the procedure was $10,183 +/- $1,082. CONCLUSIONS: The majority of patients undergoing radiofrequency catheter ablation of an accessory AV connection can be treated safely on an outpatient basis.


Assuntos
Procedimentos Cirúrgicos Ambulatórios/economia , Nó Atrioventricular/cirurgia , Ablação por Cateter , Avaliação de Processos e Resultados em Cuidados de Saúde , Síndrome de Wolff-Parkinson-White/cirurgia , Adulto , Procedimentos Cirúrgicos Ambulatórios/normas , Ablação por Cateter/efeitos adversos , Ablação por Cateter/economia , Custos e Análise de Custo , Estudos de Viabilidade , Feminino , Hospitais Universitários , Humanos , Masculino , Michigan , Estudos Prospectivos , Fatores de Risco , Segurança , Fatores de Tempo , Síndrome de Wolff-Parkinson-White/epidemiologia
18.
J Am Coll Cardiol ; 21(1): 85-9, 1993 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8417081

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the utility of the 12-lead electrocardiogram (ECG) for differentiating paroxysmal narrow QRS complex tachycardias. BACKGROUND: Previous studies evaluating the utility of the 12-lead ECG for differentiating paroxysmal supraventricular tachycardia types have shown conflicting results on the usefulness of some ECG criteria, and some criteria that are considered to be useful have never been formally evaluated. METHODS: Two hundred forty-two ECGs demonstrating paroxysmal narrow QRS complex (< 0.11 ms) tachycardia (rate > or = 120 beats/min) were analyzed. All ECGs were analyzed by an observer who had no knowledge of the mechanism of the tachycardia. RESULTS: There were 137 atrioventricular (AV) reciprocating tachycardias, 93 AV node reentrant tachycardias and 12 atrial tachycardias. Six criteria were found to be significantly different between tachycardia types by univariate analysis. A P wave separate from the QRS complex was observed more frequently in AV reciprocating tachycardia (68%) and atrial tachycardias (75%). A pseudo r' deflection in lead V1 and a pseudo S wave in the inferior leads were more common in AV node reentrant tachycardia (58% and 14%, respectively); QRS alternans was present more often during AV reciprocating tachycardia (27%). When a P wave was present, an RP/PR interval ratio > or = 1 was more common in atrial tachycardias (89%). During sinus rhythm, manifest pre-excitation was observed more often in patients with AV reciprocating tachycardia (45%). By multivariate analysis, the presence of a P wave separate from the QRS complex, pseudo r' deflection in lead V1, QRS alternans during tachycardia and the presence of pre-excitation during sinus rhythm were independent predictors of tachycardia type. These criteria correctly identified 86% of AV node reentrant tachycardias, 81% of AV reciprocating tachycardias and incorrectly assigned the tachycardia type in 19% of cases. CONCLUSIONS: Several features on the ECG are useful for differentiating supraventricular tachycardia type. However, approximately 20% of tachycardias may be incorrectly classified on the basis of analysis of the ECG; therefore, the ECG should not serve as the sole means for determining tachycardia mechanism.


Assuntos
Eletrocardiografia/métodos , Taquicardia Paroxística/diagnóstico , Taquicardia Supraventricular/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Distribuição de Qui-Quadrado , Diagnóstico Diferencial , Eletrocardiografia/estatística & dados numéricos , Humanos , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Sensibilidade e Especificidade , Taquicardia Paroxística/epidemiologia , Taquicardia Supraventricular/epidemiologia
19.
J Am Coll Cardiol ; 19(2): 347-52, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1732363

RESUMO

Although previous studies have demonstrated that the electrophysiologic effects of many antiarrhythmic agents can be reversed by catecholamines, the susceptibility of amiodarone to such reversal is unknown. The objective of this study was to compare the relative degree of reversal of the electrophysiologic effects of quinidine and amiodarone by epinephrine infusions that result in plasma epinephrine levels similar to those achieved during various physiologic stresses. Twenty-nine patients who had inducible sustained monomorphic ventricular tachycardia and underwent electropharmacologic testing with quinidine and amiodarone were enrolled in the study. The variables measured before and during an epinephrine infusion (25 or 50 ng/kg per min) included the sinus cycle length, mean arterial pressure, QT interval and effective refractory period at drive train cycle lengths of 600 and 400 ms. The effective refractory period measured at a drive train cycle length of 600 ms shortened less during amiodarone therapy (2 +/- 2%) than during quinidine therapy (6 +/- 4%) or than in the baseline state (6 +/- 4%; p less than 0.01). Similar results were obtained during evaluation of the effective refractory period at a cycle length of 400 ms. Epinephrine infusion, at both 25 and 50 ng/kg per min, completely reversed the effects of quinidine and partially reversed the effects of amiodarone on the effective refractory period. The effects of epinephrine on the sinus cycle length and QT interval were similar in the baseline state and in conjunction with quinidine and amiodarone. Twenty-four patients underwent programmed ventricular stimulation during amiodarone therapy alone and in conjunction with either a 25- or a 50-ng/kg per min infusion of epinephrine.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Amiodarona/antagonistas & inibidores , Epinefrina/farmacologia , Quinidina/antagonistas & inibidores , Taquicardia/tratamento farmacológico , Amiodarona/uso terapêutico , Estimulação Cardíaca Artificial , Eletrocardiografia , Eletrofisiologia , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Quinidina/uso terapêutico , Taquicardia/diagnóstico , Taquicardia/fisiopatologia
20.
J Am Coll Cardiol ; 19(7): 1583-7, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1593054

RESUMO

The purpose of this study was to determine the charges for radiofrequency catheter modification of the atrioventricular (AV) node in 15 patients with symptomatic AV node reentrant tachycardia despite pharmacologic therapy and to compare these charges with the estimated charges for health care utilization by the same patients before the catheter procedure was performed. There were seven men and eight women with a mean age of 50 +/- 17 years. The mean duration and frequency of symptoms were 16 +/- 9 years and 4.5 +/- 6 episodes/month, respectively. Fourteen of the 15 patients required only one procedure for diagnosis and cure of AV node reentrant tachycardia and 1 patient required two sessions. All patients underwent electrophysiologic study before discharge from the hospital to confirm the short-term efficacy of the procedure. The mean duration of the hospital stay was 3 +/- 1.5 days and the mean total charge/patient expressed in 1991 dollars was $15,893 +/- $3,338 for catheter modification. These total charges consisted of hospital charges of $8,105 +/- $2,466 and physician charges of $7,788 +/- $971. All patients had a successful outcome and required no additional antiarrhythmic therapy. The estimated cost of health care utilization for these 15 patients before cure of AV node reentrant tachycardia was $7,651/patient per year. These estimated costs included charges incurred for emergency room visits, office visits, hospitalizations and antiarrhythmic drug therapy. In conclusion, the results of this study indicate that the annual health care costs incurred by patients who have symptomatic, drug-refractory paroxysmal supraventricular tachycardia caused by AV node reentry are substantial.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Antiarrítmicos/uso terapêutico , Nó Atrioventricular/cirurgia , Eletrocoagulação/economia , Taquicardia por Reentrada no Nó Atrioventricular/economia , Antiarrítmicos/economia , Custos e Análise de Custo , Honorários Médicos , Feminino , Serviços de Saúde/estatística & dados numéricos , Humanos , Tempo de Internação/economia , Masculino , Pessoa de Meia-Idade , Ondas de Rádio , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/tratamento farmacológico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa