Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Curr Microbiol ; 81(7): 196, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816509

RESUMO

Antimicrobial susceptibility testing (AST) by disk diffusion provides an accurate image of bacterial growth, enabling the detection of culture purity, heterogeneous growth, and antibiotic interactions. However, this manual method is time-consuming and visual interpretation is prone to errors. To overcome these disadvantages, the Radian® In-Line Carousel (Copan, Brescia, Italy) was launched, which is a WASPLab® module dedicated to full automation of (pre)-analytical steps as well as interpretation of disk diffusion AST. However, until now, no evaluation of Radian® against manual disk diffusion has been performed. We assessed the categorical agreement (CA) between standardized disk diffusion (reference method) and Radian® using EUCAST 2021 breakpoints. We tested 135 non-duplicate strains, selected from the National EUCAST challenge panel, clinical strains, and external quality controls. The strains included Enterobacterales (n = 63), Enterococcus faecalis (n = 3), Enterococcus faecium (n = 10), Pseudomonas aeruginosa (n = 16), Staphylococcus aureus (n = 19), coagulase-negative staphylococci (n = 4), and Streptococcus spp. (n = 20). Furthermore, we explored antibiotic disk thermolability in the WASP Radian® carousel by testing 10 ATCC® strains up to 7 days. The observed CA was 95.3%, 96.3%, 93.8%, 97.3% and 98.0% for Enterobacterales, Enterococcus spp., P. aeruginosa, Staphylococcus spp. and Streptococcus spp., respectively, resulting in an acceptable overall CA for all groups. (Very) major error rates were ≤ 5% for all antibiotics. Antibiotic disk thermostability was confirmed up to 4 days in the WASP Radian® In-Line Carousel. The Radian® In-Line Carousel provides a fully automated solution for accurate disk diffusion AST, reducing workload and improving standardization and traceability. In addition, our study demonstrated the thermostability of antibiotic disks up to 4 days in the WASP Radian® In-Line Carousel.


Assuntos
Antibacterianos , Bactérias , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão , Antibacterianos/farmacologia , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/métodos , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/normas , Bactérias/efeitos dos fármacos , Humanos , Testes de Sensibilidade Microbiana/métodos , Automação Laboratorial
2.
Int J Lab Hematol ; 46(4): 657-664, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38421076

RESUMO

OBJECTIVES: Hematopoietic stem cell transplantation (HSCT) is a potentially curative treatment for various diseases. The measurement of CD34+ cells is crucial to schedule the peripheral blood stem cell collection and assess the engraftment potential of the apheresis product. The AQUIOS STEM system has been introduced as a novel application on the AQUIOS CL, a fully automated flow cytometer, for the enumeration of CD34+ hematopoietic progenitor cells (HPCs) in accordance with the The International Society for Hematotherapy and Graft Engineering guidelines. This study aimed to assess the potential of the novel AQUIOS STEM system versus currently used systems including the FACSCanto-II and the FACS Lyric flow cytometer in a multicenter study. METHODS: A total of 91 samples were used for the validation of the AQUOIS STEM system, including an analytical performance evaluation by means of assessing precision, sample stability, intersample carryover, and linearity and a method comparison with the present FACS systems in use to assess analytical and clinical decision agreement. RESULTS: Results showed excellent precision, with coefficient of variations <15% for dedicated quality control material and patient samples. There was no significant carry over. The fresh apheresis samples were stable when stored overnight at room temperature and at 4°C. Analytical comparison with the current systems demonstrated good correlation in peripheral blood, and minimal, clinically neglectable systematic and proportional bias in fresh apheresis products but a low correlation coefficient in cryopreserved products. CONCLUSIONS: The STEM system on AQUIOS CL allows automated enumeration of CD34+ stem cells, demonstrating good analytical performance and promising overall outcomes in peripheral blood and fresh apheresis products.


Assuntos
Antígenos CD34 , Citometria de Fluxo , Células-Tronco Hematopoéticas , Humanos , Antígenos CD34/análise , Remoção de Componentes Sanguíneos/métodos , Citometria de Fluxo/métodos , Transplante de Células-Tronco Hematopoéticas , Células-Tronco Hematopoéticas/citologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa