1.
Crit Care Med ; 48(10): 1494-1502, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32897667

RESUMO

OBJECTIVES: Hysteresis of the respiratory system pressure-volume curve is related to alveolar surface forces, lung stress relaxation, and tidal reexpansion/collapse. Hysteresis has been suggested as a means of assessing lung recruitment. The objective of this study was to determine the relationship between hysteresis, mechanical characteristics of the respiratory system, and lung recruitment assessed by a CT scan in mechanically ventilated acute respiratory distress syndrome patients. DESIGN: Prospective observational study. SETTING: General ICU of a university hospital. PATIENTS: Twenty-five consecutive sedated and paralyzed patients with acute respiratory distress syndrome (age 64 ± 15 yr, body mass index 26 ± 6 kg/m, PaO2/FIO2 147 ± 42, and positive end-expiratory pressure 9.3 ± 1.4 cm H2O) were enrolled. INTERVENTIONS: A low-flow inflation and deflation pressure-volume curve (5-45 cm H2O) and a sustained inflation recruitment maneuver (45 cm H2O for 30 s) were performed. A lung CT scan was performed during breath-holding pressure at 5 cm H2O and during the recruitment maneuver at 45 cm H2O. MEASUREMENTS AND MAIN RESULTS: Lung recruitment was computed as the difference in noninflated tissue and in gas volume measured at 5 and at 45 cm H2O. Hysteresis was calculated as the ratio of the area enclosed by the pressure-volume curve and expressed as the hysteresis ratio. Hysteresis was correlated with respiratory system compliance computed at 5 cm H2O and the lung gas volume entering the lung during inflation of the pressure-volume curve (R = 0.749, p < 0.001 and R = 0.851, p < 0.001). The hysteresis ratio was related to both lung tissue and gas recruitment (R = 0.266, p = 0.008, R = 0.357, p = 0.002, respectively). Receiver operating characteristic analysis showed that the optimal cutoff value to predict lung tissue recruitment for the hysteresis ratio was 28% (area under the receiver operating characteristic curve, 0.80; 95% CI, 0.62-0.98), with sensitivity and specificity of 0.75 and 0.77, respectively. CONCLUSIONS: Hysteresis of the respiratory system computed by low-flow pressure-volume curve is related to the anatomical lung characteristics and has an acceptable accuracy to predict lung recruitment.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/fisiopatologia , Mecânica Respiratória/fisiologia , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial , Tomografia Computadorizada por Raios X
2.
Crit Care Med ; 47(11): 1599-1606, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31464770

RESUMO

OBJECTIVES: Lung CT is the reference imaging technique for acute respiratory distress syndrome, but requires transportation outside the intensive care and x-ray exposure. Lung ultrasound is a promising, inexpensive, radiation-free, tool for bedside imaging. Aim of the present study was to compare the global and regional diagnostic accuracy of lung ultrasound and CT scan. DESIGN: A prospective, observational study. SETTING: Intensive care and radiology departments of a University hospital. PATIENTS: Thirty-two sedated, paralyzed acute respiratory distress syndrome patients (age 65 ± 14 yr, body mass index 25.9 ± 6.5 kg/m, and PaO2/FIO2 139 ± 47). INTERVENTIONS: Lung CT scan and lung ultrasound were performed at positive end-expiratory pressure 5 cm H2O. A standardized assessment of six regions per hemithorax was used; each region was classified for the presence of normal aeration, alveolar-interstitial syndrome, consolidation, and pleural effusion. Agreement between the two techniques was calculated, and diagnostic variables were assessed for lung ultrasound using lung CT as a reference. MEASUREMENTS AND MAIN RESULTS: Global agreement between lung ultrasound and CT ranged from 0.640 (0.391-0.889) to 0.934 (0.605-1.000) and was on average 0.775 (0.577-0.973). The overall sensitivity and specificity of lung ultrasound ranged from 82.7% to 92.3% and from 90.2% to 98.6%, respectively. Similar results were found with regional analysis. The diagnostic accuracy of lung ultrasound was significantly higher when those patterns not reaching the pleural surface were excluded (area under the receiver operating characteristic curve: alveolar-interstitial syndrome 0.854 [0.821-0.887] vs 0.903 [0.852-0.954]; p = 0.049 and consolidation 0.851 [0.818-0.884] vs 0.896 [0.862-0.929]; p = 0.044). CONCLUSIONS: Lung ultrasound is a reproducible, sensitive, and specific tool, which allows for bedside detections of the morphologic patterns in acute respiratory distress syndrome. The presence of deep lung alterations may impact the diagnostic performance of this technique.


Assuntos
Pulmão/diagnóstico por imagem , Síndrome do Desconforto Respiratório/diagnóstico , Idoso , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Respiração com Pressão Positiva , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia
3.
Eur Respir J ; 47(1): 233-42, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26493798

RESUMO

The aim of the study was to determine the size and location of homogeneous inflamed/noninflamed and inhomogeneous inflamed/noninflamed lung compartments and their association with acute respiratory distress syndrome (ARDS) severity.In total, 20 ARDS patients underwent 5 and 45 cmH2O computed tomography (CT) scans to measure lung recruitability. [(18)F]2-fluoro-2-deoxy-d-glucose ([(18)F]FDG) uptake and lung inhomogeneities were quantified with a positron emission tomography-CT scan at 10 cmH2O. We defined four compartments with normal/abnormal [(18)F]FDG uptake and lung homogeneity.The homogeneous compartment with normal [(18)F]FDG uptake was primarily composed of well-inflated tissue (80±16%), double-sized in nondependent lung (32±27% versus 16±17%, p<0.0001) and decreased in size from mild, moderate to severe ARDS (33±14%, 26±20% and 5±9% of the total lung volume, respectively, p=0.05). The homogeneous compartment with high [(18)F]FDG uptake was similarly distributed between the dependent and nondependent lung. The inhomogeneous compartment with normal [(18)F]FDG uptake represented 4% of the lung volume. The inhomogeneous compartment with high [(18)F]FDG uptake was preferentially located in the dependent lung (21±10% versus 12±10%, p<0.0001), mostly at the open/closed interfaces and related to recruitability (r(2)=0.53, p<0.001).The homogeneous lung compartment with normal inflation and [(18)F]FDG uptake decreases with ARDS severity, while the inhomogeneous poorly/not inflated compartment increases. Most of the lung inhomogeneities are inflamed. A minor fraction of healthy tissue remains in severe ARDS.


Assuntos
Pulmão/diagnóstico por imagem , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Pneumonia/complicações , Compostos Radiofarmacêuticos , Síndrome do Desconforto Respiratório/etiologia , Sepse/complicações , Tomografia Computadorizada por Raios X , Ferimentos e Lesões/complicações
4.
Anesthesiology ; 124(5): 1100-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26872367

RESUMO

BACKGROUND: The ventilator works mechanically on the lung parenchyma. The authors set out to obtain the proof of concept that ventilator-induced lung injury (VILI) depends on the mechanical power applied to the lung. METHODS: Mechanical power was defined as the function of transpulmonary pressure, tidal volume (TV), and respiratory rate. Three piglets were ventilated with a mechanical power known to be lethal (TV, 38 ml/kg; plateau pressure, 27 cm H2O; and respiratory rate, 15 breaths/min). Other groups (three piglets each) were ventilated with the same TV per kilogram and transpulmonary pressure but at the respiratory rates of 12, 9, 6, and 3 breaths/min. The authors identified a mechanical power threshold for VILI and did nine additional experiments at the respiratory rate of 35 breaths/min and mechanical power below (TV 11 ml/kg) and above (TV 22 ml/kg) the threshold. RESULTS: In the 15 experiments to detect the threshold for VILI, up to a mechanical power of approximately 12 J/min (respiratory rate, 9 breaths/min), the computed tomography scans showed mostly isolated densities, whereas at the mechanical power above approximately 12 J/min, all piglets developed whole-lung edema. In the nine confirmatory experiments, the five piglets ventilated above the power threshold developed VILI, but the four piglets ventilated below did not. By grouping all 24 piglets, the authors found a significant relationship between the mechanical power applied to the lung and the increase in lung weight (r = 0.41, P = 0.001) and lung elastance (r = 0.33, P < 0.01) and decrease in PaO2/FIO2 (r = 0.40, P < 0.001) at the end of the study. CONCLUSION: In piglets, VILI develops if a mechanical power threshold is exceeded.


Assuntos
Lesão Pulmonar Induzida por Ventilação Mecânica/fisiopatologia , Ventiladores Mecânicos , Pressão do Ar , Animais , Elasticidade , Desenho de Equipamento , Capacidade Inspiratória , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pulmão/fisiopatologia , Fenômenos Mecânicos , Tamanho do Órgão , Edema Pulmonar/induzido quimicamente , Edema Pulmonar/patologia , Radiografia , Taxa Respiratória , Sus scrofa , Lesão Pulmonar Induzida por Ventilação Mecânica/patologia
5.
Anesthesiology ; 123(3): 618-27, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26049554

RESUMO

BACKGROUND: During mechanical ventilation, stress and strain may be locally multiplied in an inhomogeneous lung. The authors investigated whether, in healthy lungs, during high pressure/volume ventilation, injury begins at the interface of naturally inhomogeneous structures as visceral pleura, bronchi, vessels, and alveoli. The authors wished also to characterize the nature of the lesions (collapse vs. consolidation). METHODS: Twelve piglets were ventilated with strain greater than 2.5 (tidal volume/end-expiratory lung volume) until whole lung edema developed. At least every 3 h, the authors acquired end-expiratory/end-inspiratory computed tomography scans to identify the site and the number of new lesions. Lung inhomogeneities and recruitability were quantified. RESULTS: The first new densities developed after 8.4 ± 6.3 h (mean ± SD), and their number increased exponentially up to 15 ± 12 h. Afterward, they merged into full lung edema. A median of 61% (interquartile range, 57 to 76) of the lesions appeared in subpleural regions, 19% (interquartile range, 11 to 23) were peribronchial, and 19% (interquartile range, 6 to 25) were parenchymal (P < 0.0001). All the new densities were fully recruitable. Lung elastance and gas exchange deteriorated significantly after 18 ± 11 h, whereas lung edema developed after 20 ± 11 h. CONCLUSIONS: Most of the computed tomography scan new densities developed in nonhomogeneous lung regions. The damage in this model was primarily located in the interstitial space, causing alveolar collapse and consequent high recruitability.


Assuntos
Pulmão/patologia , Respiração Artificial/efeitos adversos , Lesão Pulmonar Induzida por Ventilação Mecânica/etiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/patologia , Ventiladores Mecânicos/efeitos adversos , Animais , Animais Recém-Nascidos , Feminino , Respiração Artificial/tendências , Suínos , Fatores de Tempo , Ventiladores Mecânicos/tendências
6.
J Crit Care ; 55: 42-47, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31704618

RESUMO

PURPOSE: Aim of this study was to evaluate the effect of acute respiratory distress syndrome (ARDS) duration on gas-exchange, respiratory mechanics, specific lung elastance and mechanical power. MATERIALS AND METHODS: In a single center prospective study 28 ARDS patients (66.4 ±â€¯10.0 years, BMI 23.6[21.3-28.8] kg/m2, PaO2/FiO2 148.9[99.6-173.5]) who still presented ARDS criteria after 7-days of mechanical ventilation were studied in early and persistent phase of the disease (day-1 and after 7-days). Each patient underwent PEEP trial at 5-15 cmH2O in both phases. RESULTS: At both PEEP levels the PaO2 was similar in both phases (early: 70.7[65.1-84.4] vs 102.0[85.5-131.8] mmHg; persistent 70.7[63.0-76.2] vs 97.4[86.5-117.1] mmHg, 5-15 cmH2O respectively), the PaCO2 was significantly higher in the persistent phase at both PEEP levels (early 50.6 ±â€¯10.2 vs 52.1 ±â€¯10.5 mmHg; persistent 57.7 ±â€¯13.4 vs 56.9 ±â€¯12.8 mmHg). Specific lung elastance was not different in the early compared to the persistent phase 12.5 ±â€¯3.1 vs 12.2 ±â€¯3.8 cmH2O. The mechanical power normalized for the functional residual capacity increased with PEEP and was similar in both phases (early 23.4[12.8-32.8] vs 34.3[25.3-47.9], persistent 16.3[10.9-24.1] vs 26.7[19.9-46.0] J/min/L, 5-15 cmH2O respectively). CONCLUSIONS: The persistent phase of ARDS for 7-days did not affect the respiratory mechanics while significantly impaired the PaCO2 exchange.


Assuntos
Complacência Pulmonar , Síndrome do Desconforto Respiratório/terapia , Idoso , Feminino , Humanos , Itália , Masculino , Respiração com Pressão Positiva , Estudos Prospectivos , Síndrome do Desconforto Respiratório/mortalidade , Síndrome do Desconforto Respiratório/fisiopatologia