Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Chromatogr B Analyt Technol Biomed Life Sci ; 862(1-2): 132-9, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18162446

RESUMO

We describe a liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for levocetirizine quantification (I) in human plasma. Sample preparation was made using a fexofenadine (II) addition as internal standard (IS), liquid-liquid extraction using cold dichloromethane, and dissolving the final extract in acetonitrile. I and II (IS) were injected in a C18 column and the mobile phase composed of acetonitrile:water:formic acid (80.00:19.90:0.10, v/v/v) and monitored using positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 389>201 for I and m/z 502>467 for II. The limit of quantification and the dynamic range achieved were 0.5ng/mL and 0.5-500.0ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as its application to the analysis of plasma samples taken up to 48h after oral administration of 5mg of levocetirizine dichloridrate in healthy volunteers demonstrate its applicability to bioavailability studies.


Assuntos
Cetirizina/sangue , Antagonistas dos Receptores Histamínicos H1/sangue , Piperazinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Adolescente , Adulto , Disponibilidade Biológica , Cetirizina/farmacocinética , Estudos Cross-Over , Antagonistas dos Receptores Histamínicos H1/farmacocinética , Humanos , Pessoa de Meia-Idade , Piperazinas/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Equivalência Terapêutica
2.
Artigo em Inglês | MEDLINE | ID: mdl-17098483

RESUMO

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of memantine (I) in human plasma is presented. Sample preparation consisted of the addition of amantadine (II) as internal standard (IS), liquid-liquid extraction in basic conditions using a mixture of diethyl ether-chloroform (7:3, v/v) as extracting solvent, followed by centrifugation, solvent evaporation and sample reconstitution in methanol. Both I and II (internal standard) were analyzed using a C18 column and a mobile phase composed of methanol-water-formic acid (80:20:0.1, v/v/v). Eluted compounds were monitored using positive mode electrospray (ES) tandem mass spectrometry. The analyses were carried out by selected reaction monitoring (SRM) using the parent to daughter combinations of m/z 180>163 (memantine) and m/z 152>135 (amantadine). The peak areas from the analyte and IS were used for quantification of I. The achieved limit of quantification (LOQ) was 0.1 ng/mL; the assay exhibited a linear dynamic range of 0.1-50.0 ng/mL with a determination coefficient (r2) of at least 0.98. Validation results on linearity, specificity, accuracy, precision and stability, as well as on application to the analysis of samples taken up to 320 h after oral administration of 20mg (two 10mg capsules) of I in healthy volunteers demonstrated the applicability to bioequivalence studies.


Assuntos
Cromatografia Líquida/métodos , Memantina/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Antiparkinsonianos/sangue , Antiparkinsonianos/química , Antiparkinsonianos/farmacocinética , Humanos , Memantina/química , Memantina/farmacocinética , Estrutura Molecular , Reprodutibilidade dos Testes , Estereoisomerismo , Equivalência Terapêutica
3.
J Chromatogr B Analyt Technol Biomed Life Sci ; 853(1-2): 127-32, 2007 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-17442639

RESUMO

Here we present a sensitive and specific liquid chromatography-tandem mass spectrometric method for the quantification of dimenhydrinate (I) in human plasma. Sample preparation is conducted using citalopram (II) addition as an internal standard (IS), liquid-liquid extraction with basified plasma using a mixture hexane/acetate (1:1, v/v) as the extracting solvent, and the final extract reconstituted in the mobile phase. I and II (IS) were injected in a C8 column with the mobile phase composed of methanol:isopropanol:water:formic acid (78.00:19.92:2.00:0.08, v/v/v/v) and monitored using a positive electrospray source with tandem mass spectrometry analyses. The selected reaction monitoring (SRM) was set using precursor ion and product ion combinations of m/z 256.0>167.0 and m/z 325.0>109.0 for I and II, respectively. The limit of quantification (LOQ) was 0.4 ng/mL, the dynamic range being 0.4-200 ng/mL. Validation results on linearity, specificity, accuracy, precision and stability, as well as on application to the analysis of plasma samples taken up to 24 h after oral administration of 100 mg of dimenhydrinate in healthy volunteers demonstrated its applicability to bioavailability studies.


Assuntos
Cromatografia Líquida/métodos , Dimenidrinato/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Disponibilidade Biológica , Dimenidrinato/química , Dimenidrinato/farmacocinética , Antagonistas dos Receptores Histamínicos H1/sangue , Antagonistas dos Receptores Histamínicos H1/química , Antagonistas dos Receptores Histamínicos H1/farmacocinética , Humanos , Estrutura Molecular , Reprodutibilidade dos Testes
4.
J Mass Spectrom ; 40(9): 1197-202, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16127659

RESUMO

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.


Assuntos
Cromatografia Líquida de Alta Pressão , Antagonistas de Dopamina/sangue , Antagonistas de Dopamina/farmacocinética , Metoclopramida/análogos & derivados , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Metoclopramida/sangue , Metoclopramida/farmacocinética , Equivalência Terapêutica
5.
J Pharm Pharm Sci ; 8(2): 340-7, 2005 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-16124946

RESUMO

PURPOSE: A sensitive, robust, and selective liquid chromatographic-tandem mass spectrometric method (LC-MS/MS) was developed and validated for paroxetine quantification in human EDTA plasma. METHODS: Sample preparation was based on liquid-liquid extraction using a mixture of ethyl acetate/hexane (50/50; v/v) to extract the drug and internal standard from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 1.6 and 1.7 for paroxetine and fluoxetine (IS), respectively. The ionization was optimized using ESI(+) and selectivity was achieved by tandem mass spectrometric analysis using MRM functions, 330.0 --> 70.0 and 310 --> 43.9 for paroxetine and fluoxetine. RESULTS: Analytical curve ranged from 0.2 to 20.0 ng/mL. Inter-day precision and accuracy of the quality control (QC) samples were < 15% relative standard deviation (RSD). Analyte stability during sampling processing and storage were established. CONCLUSION: Validation results on linearity, specificity, accuracy, precision as well as application to the analysis of samples taken up to 120 h after oral administration of 20 mg of paroxetine in 28 healthy volunteers were found to be of good performance in bioequivalence study.


Assuntos
Química Farmacêutica/métodos , Paroxetina/sangue , Adolescente , Adulto , Cromatografia Líquida/métodos , Estudos Cross-Over , Humanos , Masculino , Espectrometria de Massas/métodos , Paroxetina/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa