Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 23(3): 107, 2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35345274

RESUMO

Cardiac simulation has moved from early life-saving pacemakers meant only to prevent asystole to current devices capable of physiologic stimulation for the treatment of heart rhythm and heart failure, that are also intended for remote patient and disease-progression monitoring. The actual vision of contemporary pacing aims to correct the electrophysiologic roots of mechanical inefficiency regardless of underlying structural heart diseases. The awareness of the residual cardiac dyssynchrony related to customary cardiac pacing has changed the concept of what truly represents "physiologic pacing". On a different perspective, leadless stimulation to abolish CIED surgery and prevent lead-related complications is becoming a priority both for young device recipients and for frail, elderly patients. Careful clinical evaluation attempts to bridge decision-making to patient-tailored therapy.


Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Idoso , Desenho de Equipamento , Previsões , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos
3.
J Clin Med ; 11(20)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36294401

RESUMO

(1) Background: Leadless (LL) stimulation is perceived to lower surgical, vascular, and lead-related complications compared to transvenous (TV) pacemakers, yet controlled studies are lacking and real-life experience is non-conclusive. (2) Aim: To prospectively analyse survival and complication rates in leadless versus transvenous VVIR pacemakers. (3) Methods: Prospective analysis of mortality and complications in 344 consecutive VVIR TV and LL pacemaker recipients between June 2015 and May 2021. Indications for VVIR pacing were "slow" AF, atrio-ventricular block in AF or in sinus rhythm in bedridden cognitively impaired patients. LL indication was based on individualised clinical judgement. (4) Results: 72 patients received LL and 272 TV VVIR pacemakers. LL pacemaker indications included ongoing/expected chronic haemodialysis, superior venous access issues, active lifestyle with low pacing percentage expected, frailty causing high bleeding/infectious risk, previous valvular endocarditis, or device infection requiring extraction. No significant difference in the overall acute and long-term complication rate was observed between LL and TV cohorts, with greater mortality occurring in TV due to selection of older patients. (5) Conclusions: Given the low complication rate and life expectancy in this contemporary VVIR cohort, extending LL indications to all VVIR candidates is unlikely to provide clear-cut benefits. Considering the higher costs of LL technology, careful patient selection is mandatory for LL PMs to become advantageous, i.e., in the presence of vascular access issues, high bleeding/infectious risk, and long life expectancy, rendering lead-related issues and repeated surgery relevant in the long-term perspective.

4.
Expert Rev Med Devices ; 18(2): 161-177, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33336616

RESUMO

Introduction: Cardiac stimulation evolved from life-saving devices to prevent asystole to the treatment of heart rhythm disorders and heart failure, capable of remote patient and disease-progression monitoring. Cardiac stimulation nowadays aims to correct the electrophysiologic roots of mechanical inefficiency in different structural heart diseases.Areas covered: Clinical experience, as per available literature, has led to awareness of the concealed risks of customary cardiac pacing, that can inadvertently cause atrio-ventricular and inter/intra-ventricular dyssynchrony. New pacing modalities have emerged, leading to a new concept of what truly represents 'physiologic pacing' beyond maintenance of atrio-ventricular coupling. In this article we will analyze the emerging evidence in favor of the available strategies to achieve an individualized physiologic setting in bradycardia pacing, and the hints of future developments.Expert opinion: 'physiologic stimulation' technologies should evolve to enable an effective and widespread adoption. In one way new guiding catheters and the adoption of electrophysiologic guidance and non-fluoroscopic lead implantation are needed to make His-Purkinje pacing successful and effective at long term in a shorter procedure time; in the other way leadless stimulation needs to upgrade to a superior physiologic setting to mimic customary DDD pacing and possibly His-Purkinje pacing.


Assuntos
Bradicardia/terapia , Estimulação Cardíaca Artificial/tendências , Terapia de Ressincronização Cardíaca , Ensaios Clínicos como Assunto , Estimulação Elétrica , Sistema de Condução Cardíaco/patologia , Ventrículos do Coração/patologia , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa