Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Emerg Med ; 64(5): 564-573, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37037760

RESUMO

BACKGROUND: Peripheral intravenous catheter (PIVC) postinsertion failure rates are unacceptable. Ultrasonography is an adjunctive tool that may improve PIVC utilization success. OBJECTIVES: Determine if ultrasonographically guided (USG) PIVCs placed in the emergency department (ED) significantly decreases postinsertion failure rate, increases utility time, and decreases postremoval complication rate. Determine if catheter-to-vein ratio (CVR) predicts postinsertion failure. METHODS: Participants were randomized to either standard or USG cohort. Data collection included participant and PIVC characteristics, vein measurements, postinsertion failure, and postremoval complication. Chi-square analysis compared postinsertion failure rates. Group t-test compared utility times. Postremoval complication rates were compared with standard rate analysis. The receiver operating characteristic curve was calculated to determine if CVR could predict postinsertion failure. An enrollment of 582 was estimated. RESULTS: A total of 223 patients were enrolled, with 222 PIVCs investigated. Standard cohort included 116 PIVCs and USG cohort included 106 PIVCs. A total of 212 vein diameters were analyzed. USG PIVC insertion did not result in fewer postinsertion failures (p = 0.654) or longer utility time (p = 0.808). Postremoval complications were not significantly lower (p = 0.414). Receiver operating characteristic curve showed a cut-off CVR of ∼ 0.21. Area under the curve was 0.621 (p = 0.063, 95% confidence interval 0.508-0.734). CONCLUSION: The USG technique did not decrease postinsertion failure rate, increase utility time, or significantly decrease postremoval complication rate. A CVR predictive of postinsertion failure could not be determined.


Assuntos
Cateterismo Periférico , Catéteres , Humanos , Estudos Prospectivos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Remoção de Dispositivo , Serviço Hospitalar de Emergência
2.
Pediatr Crit Care Med ; 23(4): 268-276, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35081085

RESUMO

OBJECTIVES: Children receiving prolonged extracorporeal membrane oxygenation (ECMO) support may benefit from tracheostomy during ECMO by facilitating rehabilitation; however, the procedure carries risks, especially hemorrhagic complications. Knowledge of tracheostomy practices and outcomes of ECMO-supported children who undergo tracheostomy on ECMO may inform decision-making. DESIGN: Retrospective cohort study. SETTING: ECMO centers contributing to the Extracorporeal Life Support Organization registry. PATIENTS: Children from birth to 18 years who received ECMO support for greater than or equal to 7 days for respiratory failure from January 1, 2015, to December 31, 2019. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Three thousand six hundred eighty-five children received at least 7 days of ECMO support for respiratory failure. The median duration of ECMO support was 13.0 days (interquartile range [IQR], 9.3-19.9 d), and inhospital mortality was 38.7% (1,426/3,685). A tracheostomy was placed during ECMO support in 94/3,685 (2.6%). Of those who received a tracheostomy on ECMO, the procedure was performed at a median 13.2 days (IQR, 6.3-25.9 d) after initiation of ECMO. Surgical site bleeding was documented in 26% of children who received a tracheostomy (12% after tracheostomy placement). Among children who received a tracheostomy, the median duration of ECMO support was 24.2 days (IQR, 13.0-58.7 d); inhospital mortality was 30/94 (32%). Those that received a tracheostomy before 14 days on ECMO were older (median age, 15.8 yr [IQR, 4.7-15.5] vs 11.7 yr [IQR, 11.5-17.3 yr]; p =0.002) and more likely to have been supported on venovenous-ECMO (84% vs 52%; p = 0.001). Twenty-two percent (11/50) of those who received a tracheostomy before 14 days died in the hospital, compared with 19/44 (43%) of those who received a tracheostomy at 14 days or later (p = 0.03). CONCLUSIONS: Tracheostomies during ECMO were uncommon in children. One in four patients who received a tracheostomy on ECMO had surgical site bleeding. Children who had tracheostomies placed after 14 days were younger and had worse outcomes, potentially representing tracheostomy as a "secondary" strategy for prolonged ECMO support.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Respiratória , Adolescente , Criança , Oxigenação por Membrana Extracorpórea/métodos , Hemorragia/etiologia , Humanos , Respiração Artificial/efeitos adversos , Estudos Retrospectivos , Traqueostomia/efeitos adversos , Traqueostomia/métodos
3.
Perfusion ; 37(2): 123-127, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33459153

RESUMO

Recent advances in ECLS technology have led to the adoption of centrifugal pumps for the majority of patients worldwide. Despite several advantages of centrifugal pumps, they remain controversial because a number of studies have shown increased rates of hemolysis. The aim of this study was to assess the impact of transitioning from roller to centrifugal pumps on hemolysis rates at our center. A retrospective analysis of all pediatric ECMO patients at a single center between 2005 and 2017 was undertaken. Hemolysis was defined as a plasma free hemoglobin >50 mg/dL. Multivariable logistic regression was performed correcting for several factors to determine risk factors for hemolysis and analyze outcomes among patients with hemolysis. Significant findings were those with p < 0.05. A total of 590 patients were identified during the study period. Multivariable logistic regression for risk factors for hemolysis showed roller pumps (OR 1.92, CI 1.11-3.33) and ECMO duration (OR 1.002 per hour, CI 1.00-1.01) to be significant factors. Rates of hemolysis significantly improved following conversion from roller to centrifugal pumps, with significantly lower rates of hemolysis in 2012, 2015, 2016, and 2017 when compared to the historical average with roller pumps from 2005 to 2009 (34.7%). Additionally, hemolysis was associated with an increased risk of death (OR 3.59, CI 2.05-6.29) when correcting for other factors. These data suggest decreasing rates of hemolysis with centrifugal pumps compared to roller pumps. Since hemolysis was also associated with increased risk of death, these data support the switch from roller to centrifugal pumps at ECMO centers.


Assuntos
Oxigenação por Membrana Extracorpórea , Hemólise , Criança , Oxigenação por Membrana Extracorpórea/efeitos adversos , Testes Hematológicos , Humanos , Estudos Retrospectivos , Fatores de Risco
4.
Pediatr Res ; 89(3): 622-627, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32357365

RESUMO

BACKGROUND: Bubble continuous positive airway pressure is an established therapy for infants in respiratory distress. In resource-limited settings, few treatment options exist for infants requiring further respiratory support. A bubble bilevel device has been developed to provide nonelectric, time-cycled, pressure-limited respiratory support. We compared the efficacy of bubble bilevel ventilation with conventional mechanical ventilation in sedated rabbits. METHODS: Six adult rabbits under inhaled isoflurane general anesthesia were ventilated by alternating intervals of conventional and bubble bilevel ventilation for three 10-15-min periods. During each period, interval arterial blood gas (ABG) measurements were obtained after at least 10 min on the respective mode of ventilation. RESULTS: The bubble bilevel system was able to deliver the following pressures: 20/7, 15/5, 12/5, 8/5 cm H2O. The estimated differences in arterial blood gas values on bubble bilevel vs. ventilator were as follows (normalized values): pH 7.41 vs. 7.40, pCO2 37.7 vs. 40, pO2 97.6 vs. 80. In addition, the bubble bilevel ventilation delivered consistent pressure waveforms without interruption for over 60 min on two rabbits. CONCLUSION: This study demonstrates promising in vivo results on the efficacy of a novel bubble bilevel device, which may prove useful for infants in respiratory distress. IMPACT: Given the lack of personnel, funds or infrastructure to provide neonatal mechanical ventilation in resource-limited settings, additional low-cost, low-tech treatments are necessary to save infant lives. Bubble bilevel ventilation reliably delivers two levels of airway pressure to anesthetized rabbits resulting in normalization of blood gases comparable to those achieved on a traditional ventilator. If proven effective, simple technologies like this device have the potential to significantly impact neonatal mortality due to respiratory distress globally.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Gases , Respiração Artificial/métodos , Anestesia , Animais , Gasometria , Desenho de Equipamento , Coelhos , Respiração
5.
Perfusion ; 36(2): 204-206, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32460608

RESUMO

It is rare for children to receive more than one course of support with extracorporeal membrane oxygenation, and in those who do undergo multiple episodes, the interval is usually days to weeks between events. Little data exists on re-cannulation years after an initial extracorporeal membrane oxygenation run, and late repeat cannulation can pose unique challenges. We report the case of a 10-year-old male patient with right jugular vein occlusion due to a previous course of extracorporeal membrane oxygenation as a neonate, who was successfully supported via central cannulation. This case demonstrates the importance of adequate imaging of target vasculature prior to attempting re-cannulation of a previously used vessel. Establishing a thoughtful strategy for late repeat cannulation is essential to achieve safe access in unusual and challenging situations.


Assuntos
Oxigenação por Membrana Extracorpórea , Cateterismo , Criança , Humanos , Recém-Nascido , Veias Jugulares/diagnóstico por imagem , Masculino , Estudos Retrospectivos
6.
J Surg Res ; 231: 361-365, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30278954

RESUMO

BACKGROUND: Congenital chylothorax (CC) can have devastating consequences for neonates. We sought to determine the outcomes of cases treated at our institution and evaluate the role of fetal intervention. MATERIALS AND METHODS: With Institutional Review Board approval, patients treated at our institution 09/2006-04/2016 with CC were reviewed. History and outcomes were compared between patients undergoing fetal intervention (fetal group) and patients who did not (control group). RESULTS: Twenty-three patients were identified. Mean gestational age at birth was 35 wk. Overall mortality was 30% (7 patients). Nineteen patients (83%) were prenatally diagnosed, and 10 patients (43%) underwent fetal intervention. Birth weight was significantly lower in the fetal group compared to the control group (median interquartile range [IQR]; 2.5 [2.3-3.0] versus 3.3 [2.6-3.7] kg, P = 0.02). Apgar scores were significantly higher in the fetal group than the control group at 1 and 5 min (median [IQR]; 6 [4-8] versus 1 [1-2], P = 0.005 and 8 [7-9] versus 2 [2-6], P = 0.008, respectively). For those patients with prenatal diagnosis of CC and hydrops fetalis, thrombosis and lymphopenia were both improved in the fetal group (thrombosis 0% versus 40%, P = 0.03; lymphocyte nadir [median {IQR}] 1.5 [0.6-2.9] versus 0.1 [0.05-0.2], P = 0.02). Duration of support with mechanical ventilation was significantly shorter in the fetal group (median [IQR]; 1 [0-40] versus 41 [29-75] d, P = 0.04). CONCLUSIONS: Fetal intervention for CC is associated with improved Apgar scores and decreased ventilator days and complications in patients with hydrops fetalis. Fetuses with chylothorax, especially those with hydrops, should be referred to a fetal center for evaluation.


Assuntos
Quilotórax/congênito , Terapias Fetais , Índice de Apgar , Quilotórax/complicações , Quilotórax/diagnóstico , Quilotórax/mortalidade , Quilotórax/terapia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Diagnóstico Pré-Natal , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
7.
Mol Pharm ; 14(11): 3762-3771, 2017 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-29020775

RESUMO

A new portable gas phase nitric oxide (NO) generator is described for potential applications in inhaled NO (INO) therapy and during cardiopulmonary bypass (CPB) surgery. In this system, NO is produced at the surface of a large-area mesh working electrode by electrochemical reduction of nitrite ions in the presence of a soluble copper(II)-ligand electron transfer mediator complex. The NO generated is then transported into gas phase by either direct purging with nitrogen/air or via circulating the electrolyte/nitrite solution through a gas extraction silicone fiber-based membrane-dialyzer assembly. Gas phase NO concentrations can be tuned in the range of 5-1000 ppm (parts per million by volume for gaseous species), in proportion to a constant cathodic current applied between the working and counter electrodes. This new NO generation process has the advantages of rapid production times (5 min to steady-state), high Faraday NO production efficiency (ca. 93%), excellent stability, and very low cost when using air as the carrier gas for NO (in the membrane dialyzer configuration), enabling the development of potentially portable INO devices. In this initial work, the new system is examined for the effectiveness of gaseous NO to reduce the systemic inflammatory response (SIR) during CPB, where 500 ppm of NO added to the sweep gas of the oxygenator or to the cardiotomy suction air in a CPB system is shown to prevent activation of white blood cells (granulocytes and monocytes) during extracorporeal circulation with cardiotomy suction conducted with five pigs.


Assuntos
Ponte Cardiopulmonar/métodos , Óxido Nítrico/uso terapêutico , Administração por Inalação , Animais , Eletroquímica/métodos , Pulmão/metabolismo , Nitritos/química , Suínos
8.
J Surg Res ; 220: 119-124, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29180172

RESUMO

BACKGROUND: Perforated appendicitis can be managed with early appendectomy, or nonoperative management followed by interval appendectomy. We aimed to identify the strategy with the lowest health care utilization and cost. METHODS: We retrospectively reviewed the medical records of all children ≤18 years old with perforated appendicitis admitted to a single institution between January 2009 and March 2016. After excluding immunosuppressed patients and transfers from outside hospitals, we grouped the remaining patients by early or interval appendectomy. Cost accounting data were obtained from our institutional database. The primary outcome was total hospital cost over 2 y from initial admission for appendicitis. Other outcomes analyzed included initial admission costs, number of admissions, emergency room and clinic visits, percutaneous procedures, cross-sectional and overall imaging studies, and length of stay. RESULTS: A total of 203 children with perforated appendicitis were identified. After exclusion of immunosuppressed patients and outside hospital transfers, 94 patients were included in the study. Thirty-nine underwent early appendectomy and 55 initial nonoperative management; of these, 54 underwent elective interval appendectomy. Five of 55 patients (9%) failed initial nonoperative management and required earlier-than-planned appendectomy. Total cost over 2 y was significantly lower with early appendectomy than initial nonoperative management ($19,300 ± 14,300 versus $26,000 ± 17,500; P = 0.05). Early appendectomy resulted in fewer hospital admissions, clinic visits, invasive procedures, and imaging studies. CONCLUSIONS: Early appendectomy results in lower hospital costs and less health care utilization compared with initial nonoperative management with elective interval appendectomy. A prospective study will shed more light on this question and can assess the role of nonoperative management without interval appendectomy in children with perforated appendicitis.


Assuntos
Apendicectomia/economia , Apendicite/economia , Apendicite/terapia , Procedimentos Cirúrgicos Eletivos/economia , Custos Hospitalares , Abscesso Abdominal , Adolescente , Antibacterianos/uso terapêutico , Apendicectomia/métodos , Apendicite/diagnóstico por imagem , Criança , Pré-Escolar , Drenagem , Feminino , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
9.
J Surg Res ; 220: 88-93, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29180216

RESUMO

BACKGROUND: Gastrostomy tube placement is a common procedure that can be accomplished with a variety of techniques, each with its attendant complications. In an effort to standardize practice at our institution, we retrospectively evaluated complications including early dislodgement requiring operative repair, leaks, and granulation tissue to determine the optimal technique. MATERIALS AND METHODS: A retrospective cohort study (June 2008-July 2014) evaluating children (<18) receiving gastrostomy tubes was completed. We recorded demographic data, placement technique, and postoperative complications within 120 days. The seven techniques in use at our institution were categorized into three groups: standard pull-type techniques for percutaneous endoscopic gastrostomies (PEGs), "push" techniques using transabdominal sutures or T-fasteners for securement of the stomach, and "fascial" techniques using sutures directly from the stomach to the abdominal fascia at the stoma site. Descriptive statistics were analyzed using t test and Kruskal-Wallis tests as appropriate, and outcomes with P < 0.05 were considered significant. RESULTS: Of the 450 patients, 255 (56.7%) were male. Median age and weight at the time of operation were 19.3 months (interquartile range, 6.5-89.6 months) and 9.0 kg (interquartile range, 5.7-17.1 kg) respectively. By technique, 245 patients underwent fascial placement (54.4%), 112 underwent push (24.9 %), and 93 underwent PEG (20.7%). Push and fascial techniques were less likely become dislodged than PEG, with odds ratios (ORs) of 0.14 (confidence interval CI 0.02-0.66) and 0.31 (CI 0.11-0.83), respectively. Fascial techniques had more granulation tissue than either push or PEG pull methods, OR 2.39 (CI 1.20-3.36), and more leakage, OR 2.22 (CI 1.19-4.15). CONCLUSIONS: Dislodgement is most likely with PEG techniques. Granulation and leakage are most likely with fascial suture techniques. Push techniques are associated with the lowest complication rate.


Assuntos
Nutrição Enteral/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Gastroscopia/efeitos adversos , Gastrostomia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Criança , Pré-Escolar , Nutrição Enteral/instrumentação , Nutrição Enteral/métodos , Feminino , Gastroscopia/instrumentação , Gastroscopia/métodos , Gastrostomia/instrumentação , Gastrostomia/métodos , Humanos , Lactente , Masculino , Estudos Retrospectivos , Dispositivos de Fixação Cirúrgica , Técnicas de Sutura/efeitos adversos
10.
Semin Pediatr Surg ; 33(4): 151441, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38986242

RESUMO

Surgical repair of the diaphragm is essential for survival in congenital diaphragmatic hernia (CDH). There are many considerations surrounding the operation - why the operation matters, optimal timing of repair and its relation to extracorporeal life support (ECLS) use, minimally invasive versus open approaches, and strategies for reconstruction. Surgery is both affected by, and affects, the physiology of these infants and is an important factor in determining long-term outcomes. Here we discuss the evidence and provide insight surrounding this complex decision making, technical pearls, and outcomes in repair of CDH.

11.
Nat Ecol Evol ; 8(5): 924-935, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38499871

RESUMO

Wildlife must adapt to human presence to survive in the Anthropocene, so it is critical to understand species responses to humans in different contexts. We used camera trapping as a lens to view mammal responses to changes in human activity during the COVID-19 pandemic. Across 163 species sampled in 102 projects around the world, changes in the amount and timing of animal activity varied widely. Under higher human activity, mammals were less active in undeveloped areas but unexpectedly more active in developed areas while exhibiting greater nocturnality. Carnivores were most sensitive, showing the strongest decreases in activity and greatest increases in nocturnality. Wildlife managers must consider how habituation and uneven sensitivity across species may cause fundamental differences in human-wildlife interactions along gradients of human influence.


Assuntos
COVID-19 , Atividades Humanas , Mamíferos , Animais , Humanos , COVID-19/epidemiologia , Animais Selvagens , Ecossistema
12.
Eur J Appl Physiol ; 113(3): 743-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22941193

RESUMO

The aim of the present study was to examine the effects of sodium bicarbonate (NaHCO(3)) administration on lower-body, hypertrophy-type resistance exercise (HRE). Using a double-blind randomized counterbalanced design, 12 resistance-trained male participants (mean ± SD; age = 20.3 ± 2 years, mass = 88.3 ± 13.2 kg, height = 1.80 ± 0.07 m) ingested 0.3 g kg(-1) of NaHCO(3) or placebo 60 min before initiation of an HRE regimen. The protocol employed multiple exercises: squat, leg press, and knee extension, utilizing four sets each, with 10-12 repetition-maximum loads and short rest periods between sets. Exercise performance was determined by total repetitions generated during each exercise, total accumulated repetitions, and a performance test involving a fifth set of knee extensions to failure. Arterialized capillary blood was collected via fingertip puncture at four time points and analyzed for pH, [HCO(3)(-)], base excess (BE), and lactate [Lac(-)]. NaHCO(3) supplementation induced a significant alkaline state (pH: NaHCO(3): 7.49 ± 0.02, placebo: 7.42 ± 0.02, P < 0.05; [HCO(3)(-)]: NaHCO(3): 31.50 ± 2.59, placebo: 25.38 ± 1.78 mEq L(-1), P < 0.05; BE: NaHCO(3): 7.92 ± 2.57, placebo: 1.08 ± 2.11 mEq L(-1), P < 0.05). NaHCO(3) administration resulted in significantly more total repetitions than placebo (NaHCO(3): 139.8 ± 13.2, placebo: 134.4 ± 13.5), as well as significantly greater blood [Lac(-)] after the exercise protocol (NaHCO(3): 17.92 ± 2.08, placebo: 15.55 ± 2.50 mM, P < 0.05). These findings demonstrate ergogenic efficacy for NaHCO(3) during HRE and warrant further investigation into chronic training applications.


Assuntos
Desempenho Atlético/fisiologia , Suplementos Nutricionais , Músculo Esquelético/efeitos dos fármacos , Treinamento Resistido , Bicarbonato de Sódio/administração & dosagem , Adolescente , Adulto , Método Duplo-Cego , Humanos , Hipertrofia , Articulação do Joelho/efeitos dos fármacos , Articulação do Joelho/fisiologia , Perna (Membro) , Masculino , Músculo Esquelético/patologia , Levantamento de Peso/fisiologia , Adulto Jovem
13.
J Occup Environ Hyg ; 10(9): 487-95, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23927041

RESUMO

Manufacturing of nanoscale materials (nanomaterials) is a major outcome of nanotechnology. However, the potential adverse human health effects of manufactured nanomaterial exposure are not yet fully understood, and exposures in humans are mostly uncharacterized. Appropriate exposure control strategies to protect workers are still being developed and evaluated, and regulatory approaches rely largely on industry self-regulation and self-reporting. In this context of soft regulation, the authors sought to: 1) assess current company-reported environmental health and safety practices in the United States throughout the product life cycle, 2) consider their implications for the manufactured nanomaterial workforce, and 3) identify the needs of manufactured nanomaterial companies in developing nano-protective environmental health and safety practices. Analysis was based on the responses of 45 U.S.-based company participants in a 2009-2010 international survey of private companies that use and/or produce nanomaterials. Companies reported practices that span all aspects of the current government-recommended hierarchical approach to manufactured nanomaterials' exposure controls. However, practices that were tailored to current manufactured nanomaterials' hazard and exposure knowledge, whether within or outside the hierarchical approach, were reported less frequently than general chemical hygiene practices. Product stewardship and waste management practices-the influences of which are substantially downstream-were reported less frequently than most other environmental health and safety practices. Larger companies had more workers handling nanomaterials, but smaller companies had proportionally more employees handling nanomaterials and more frequently identified impediments to implementing nano-protective practices. Company-reported environmental health and safety practices suggest more attention to environmental health and safety is necessary, especially with regard to practices that can cause external effects. Given reported impediments, smaller companies may especially benefit from more attention. However, the manufactured nanomaterial workforce within smaller companies is particularly difficult to identify and hence locate, posing challenges to developing and enforcing appropriate workplace environmental health and safety. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a file containing Survey of Current Health and Safety Practices in the Nanomaterial Industry and a file containing figures.].


Assuntos
Saúde Ambiental , Nanoestruturas/toxicidade , Exposição Ocupacional/análise , Humanos , Nanoestruturas/efeitos adversos , Nanoestruturas/análise , Nanotecnologia , Tamanho da Partícula , Medição de Risco , Gestão da Segurança , Estados Unidos , Local de Trabalho
14.
Artigo em Inglês | MEDLINE | ID: mdl-38017346

RESUMO

Black men experience high rates of adverse health that can be prevented or mitigated by the regular use of preventive health services. Efforts are urgently needed to promote this type of health service use among Black men. The U.S. Preventive Services Task Force and the Institute of Medicine indicate that such efforts must align with Black men's values, perspectives, and preferences. However, little guidance exists on how to align these efforts for Black men. The present qualitative study was developed to understand factors associated with preventive health service use among Black men and community-informed strategies to promote preventive health service use among these men. An approach rooted in community-based participatory research and ecological theory was used. A core leadership team consisting of five Black men from the area guided the project's development, implementation, and evaluation. The core leadership team conducted 22 interviews with Black men from their communities. Four themes emerged from these interviews: (1) holistic well-being challenges faced by Black men: interaction of mental, physical, and societal forces; (2) the interplay of financial, informational, and gendered barriers/facilitators to using preventative health services among Black men; (3) the importance of shared identity in peer health education about preventive health service use; and (4) the need for community-centered initiatives to improve preventive health service use among Black men that prioritize accessibility and information. Findings of the present study can be used to tailor preventive health service use efforts for Black men. Such efforts have the potential to promote health and mitigate health disparities.

15.
Polymers (Basel) ; 14(20)2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36297848

RESUMO

As the most prevalent structural protein in the extracellular matrix, collagen has been extensively investigated for biofabrication-based applications. However, its utilisation has been impeded due to a lack of sufficient mechanical toughness and the inability of the scaffold to mimic complex natural tissues. The anisotropic alignment of collagen fibres has been proven to be an effective method to enhance its overall mechanical properties and produce biomimetic scaffolds. This review introduces the complicated scenario of collagen structure, fibril arrangement, type, function, and in addition, distribution within the body for the enhancement of collagen-based scaffolds. We describe and compare existing approaches for the alignment of collagen with a sharper focus on electro-compaction. Additionally, various effective processes to further enhance electro-compacted collagen, such as crosslinking, the addition of filler materials, and post-alignment fabrication techniques, are discussed. Finally, current challenges and future directions for the electro-compaction of collagen are presented, providing guidance for the further development of collagenous scaffolds for bioengineering and nanotechnology.

16.
ACS Appl Mater Interfaces ; 13(44): 52023-52033, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34210117

RESUMO

An In(III) based metal-organic framework (MOF), In-pbpta, with soc topology was constructed from the trigonal prismatic [In3(µ3-O)(H2O)3(O2C-)6] secondary building unit (SBU) and a custom-designed tetratopic linker H4pbpta (pbpta = 4,4',4″,4‴-(1,4-phenylenbis(pyridine-4,2,6-triyl))-tetrabenzoic acid)). The obtained MOF shows a Brunauer-Emmett-Teller surface area of 1341 m2/g with a pore volume of 0.64 cm3/g, which is the highest among the scarcely reported In-soc-MOFs. The constructed MOF demonstrates excellent performance as a heterogeneous Lewis acid catalyst for highly efficient conversion in a one-pot multicomponent Strecker reaction for the preparation of α-aminonitriles under solvent-free conditions, which can be easy to separate and recycle without significant loss of activity for up to seven cycles. The computational modeling studies suggest the presence of the three substrates in close vicinity to the In-oxo cluster. The strong interactions of the aldehyde/ketone and the amine with the In-oxo cluster together with the readily available cyanide ion around the In-oxo cluster lead to high catalytic conversion within a short period of time for the MOF catalyst. Our work therefore lays a foundation to develop MOF as a new class of efficient heterogeneous catalyst for one-pot Strecker reaction.

17.
ASAIO J ; 66(5): 572-579, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31294720

RESUMO

One in five children with end-stage lung failure (ESLF) die while awaiting lung transplant. No suitable animal model of ESLF exists for the development of artificial lung devices for bridging to transplant. Small lambs weighing 15.7 ± 3.1 kg (n = 5) underwent ligation of the left anterior pulmonary artery (PA) branch, and gradual occlusion of the right main PA over 48 hours. All animals remained hemodynamically stable. Over seven days of disease model conditions, they developed pulmonary hypertension (mean PA pressure 20 ± 5 vs. 33 ± 4 mm Hg), decreased perfusion (SvO2 66 ± 3 vs. 55 ± 8%) with supplemental oxygen requirement, and severe tachypneic response (45 ± 9 vs. 82 ± 23 breaths/min) (all p < 0.05). Severe right heart dysfunction developed (tricuspid annular plane systolic excursion 13 ± 3 vs. 7 ± 2 mm, fractional area change 36 ± 6 vs. 22 ± 10 mm, ejection fraction 51 ± 9 vs. 27 ± 17%, all p < 0.05) with severe tricuspid regurgitation and balloon-shaped dilation of the right ventricle. This model of pediatric ESLF reliably produces pulmonary hypertension, right heart strain, and impaired gas exchange, and will be used to develop a pediatric artificial lung.


Assuntos
Modelos Animais de Doenças , Insuficiência Respiratória/fisiopatologia , Animais , Animais Recém-Nascidos , Feminino , Ovinos , Carneiro Doméstico
18.
ASAIO J ; 66(1): 72-78, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30585871

RESUMO

Cardiopulmonary bypass (CPB) causes a systemic inflammatory response syndrome (SIRS) associated with multiorgan injury. A model was developed to test whether a blood-air interface (BAI) in the CPB circuit causes blood element activation and inflammation. Ten healthy swine were placed on partial CPB for 2 hours via the cervical vessels and monitored for 96 hours postoperatively. Five pigs (control group) had minimal air exposure in the circuit, while five were exposed to a BAI simulating cardiotomy suction. There were no significant differences in bypass flow or hemodynamics between the groups. In the BAI group, there was an increase in hemolysis after bypass (plasma-free hemoglobin 5.27 ± 1.2 vs. 0.94 ± 0.8 mg/dl; p = 0.01), more aggressive platelet consumption (28% vs. 83% of baseline; p = 0.009), leukocyte consumption (71% vs. 107% of baseline; p = 0.02), and increased granulocyte CD11b expression (409% vs. 106% of baseline; p = 0.009). These data suggest the inflammatory pattern responsible for the CPB-SIRS phenomenon may be driven by blood-air interaction. Future efforts should focus on BAI-associated mechanisms for minimizing blood trauma and inflammation during CPB.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Ar , Animais , Sucção/efeitos adversos , Suínos
19.
ASAIO J ; 66(4): 423-432, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31192843

RESUMO

Children with end-stage lung failure awaiting lung transplant would benefit from improvements in artificial lung technology allowing for wearable pulmonary support as a bridge-to-transplant therapy. In this work, we designed, fabricated, and tested the Pediatric MLung-a dual-inlet hollow fiber artificial lung based on concentric gating, which has a rated flow of 1 L/min, and a pressure drop of 25 mm Hg at rated flow. This device and future iterations of the current design are designed to relieve pulmonary arterial hypertension, provide pulmonary support, reduce ventilator-associated injury, and allow for more effective therapy of patients with end-stage lung disease, including bridge-to-transplant treatment.


Assuntos
Órgãos Artificiais , Insuficiência Respiratória/terapia , Criança , Desenho de Equipamento , Humanos , Transplante de Pulmão
20.
Clin Perinatol ; 46(1): 89-100, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30771822

RESUMO

Necrotizing enterocolitis occurs in 14% of infants less than 1000 g. Preoperative management varies widely, and the only absolute indication for surgery is pneumoperitoneum. Multiple biomarkers and scoring systems are under investigation, but clinical practice is still largely driven by surgeon judgment. Outcomes in panintestinal disease are poor, and multiple creative approaches are used to preserve bowel length. Overall, recovery is complicated in the short and long term. Major sequelae are stricture, short gut syndrome, and neurodevelopmental impairment. Resolving controversies in surgical necrotizing enterocolitis care requires multicenter collaboration for centralized data and tissue repositories, benchmarking, and carrying out prospective randomized controlled trials.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório/métodos , Enterocolite Necrosante/cirurgia , Seleção de Pacientes , Anastomose Cirúrgica , Drenagem/métodos , Enterostomia/métodos , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Laparotomia/métodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa