Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Lung Circ ; 28(4): 632-636, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29625867

RESUMO

BACKGROUND: The approach to intervention for congenital aortic valve stenosis (AS) differs depending upon centre bias toward a primary catheter or surgical approach. We therefore investigated associations with freedom from re-intervention (FFI) in the cohort of children who underwent primary balloon aortic valvuloplasty (BAV) for congenital AS in our centre. METHODS: All patients who underwent BAV as a primary procedure in the period between 2001 and 2015 in a single service were included. Echocardiographic parameters before and after catheterisation and procedural data was collected on all patients. RESULTS: Sixty-four (64) patients underwent BAV as the primary intervention during the study period. Follow-up data was available for 60 of these. Balloon aortic valvuloplasty was performed at a median age of 143 days (range 2 days-18.8 years). Freedom from re-intervention was observed in 75% of patients with a median follow-up of 6.8 years and a mean follow-up of 3 years. Catheter-based peak-to-peak aortic valve gradients decreased from 58±15.9mmHg to 22.9±13.1mmHg. There was no short- or long-term mortality. FFI was predicted by aortic valve morphology (p<0.01), post-BAV mean echo gradient (p=0.03) and post-BAV regurgitation (p<0.01). No patient had re-intervention for restenosis with post-BAV mean echo gradient <30mmHg. Catheter gradients before and after BAV approached significance for predicting FFI (p=0.06 and p=0.09 respectively). Fifteen (15) patients were neonates with significantly lower aortic valve (AoV) Z-scores (mean 0.63 vs 1.76, p=0.002) and no difference in FFI (p=0.19). Annulus size, balloon/annulus ratio (within the range utilised) and pre-BAV echo findings were not predictive for re-intervention. CONCLUSIONS: Balloon aortic valvuloplasty is an effective primary approach to congenital valvular AS with the potential of avoiding surgical intervention in the majority of patients at all ages. Freedom from re-intervention in our cohort was associated with valve morphology and the degree of stenosis and regurgitation immediately post BAV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Cateterismo Cardíaco/métodos , Previsões , Adolescente , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico , Criança , Pré-Escolar , Ecocardiografia , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa