Cardiol Young ; 28(8): 1067-1069, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30043721

RESUMO

Dilatation of the superior caval vein is extremely rare, with few cases described among newborns. The association of aneurysm of the superior caval vein and lymphatic malformation is extremely uncommon. We report a case of a female infant with a prenatal diagnosis of superior caval vein aneurysm presenting at birth with a neck mass that was found to be a cystic lymphangioma.


Assuntos
Aneurisma/congênito , Aneurisma/diagnóstico por imagem , Linfangioma Cístico/diagnóstico por imagem , Veia Cava Superior/diagnóstico por imagem , Dilatação Patológica , Humanos , Recém-Nascido , Linfangioma Cístico/complicações , Imageamento por Ressonância Magnética , Masculino , Ultrassonografia Doppler
2.
Herzschrittmacherther Elektrophysiol ; 34(2): 161-164, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-37115248

RESUMO

Complications associated with cardiac implantable electric devices (CIED) are manifold. They include lead dislocation, twiddler's syndrome, device malfunction, haematoma formation and infection. Infections can be divided into acute, subacute and late infections. Both the time of onset and the route of infection play a crucial role. The consequences of a CIED infection are devastating. The most modern treatment methods include the removal of all implanted implants. If complete removal is not followed in the event of infection, there is a high rate of infection recurrence. Open thoracic surgery to remove infected CIED hardware has been replaced by percutaneous lead extraction procedures. Lead extraction requires specialised equipment and expertise and may not be readily available or feasible for some patients. Each extraction procedure is associated with a small risk of potentially fatal complications (e.g. cardiac avulsion, vascular avulsion, haemothorax and cardiac tamponade). For these reasons, the performance of such procedures should be limited to centres with adequate equipment and experience. Successful salvage of CIED systems with in situ sterilisation of contaminated hardware has been reported. In our case, we report the successful salvage of an exposed generator in a frail patient treated more than 5 years after the last generator replacement.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Cardiopatias/terapia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Estudos Retrospectivos
3.
Expert Rev Med Devices ; 18(5): 493-498, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33970735

RESUMO

OBJECTIVES: The aim of this study is to demonstrate how Electrophysiology activity has been impacted by the pandemic Coronavirus disease 2019 (COVID-19). METHODS: In this multicenter retrospective study, we analyze all consecutive patients admitted for electrophysiological procedures during the COVID-19 lockdown in the Tuscany region of Italy, comparing them to patients hospitalized in the corresponding period of the previous year. RESULTS: The impact of COVID-19 on cardiac arrhythmia management was impressive, with a reduction of more than 50% in all kinds of procedures. A gender gap was observed, with a more relevant reduction for female patients. Arrhythmic urgencies requiring a device implant showed a reduced time from symptoms to first medical contact but the time from first medical contact to procedure was significantly prolonged. CONCLUSION: Hospitals need to consider how outbreaks may affect health systems beyond the immediate infection. Routine activity should be based on a risk assessment between the prompt performance of procedure and its postponement. Retrospective observational analysis such as this study could be decisive in evidence-based medicine of any future pathogen outbreak.Nonstandard Abbreviations and Acronyms PM= pacemakerICD= implantable cardioverter defibrillatorECV= electrical cardioversionEPS= electrophysiological studyAP= ablations proceduresCIED= cardiac implantable electronic devicesWCD= wearable cardioverter defibrillatorEP Lab= Electrophysiology LaboratoriesAVNRT =atrioventricular nodal reentry tachycardiaAVRT= atrioventricular reentry tachycardiaAFL= atrial flutterAF= atrial fibrillationVT= ventricular tachycardiaAT= atrial tachycardia.


Assuntos
COVID-19/epidemiologia , Atenção à Saúde , Surtos de Doenças , Técnicas Eletrofisiológicas Cardíacas , Idoso , Arritmias Cardíacas/fisiopatologia , Desfibriladores Implantáveis , Feminino , Humanos , Itália/epidemiologia , Masculino , Marca-Passo Artificial , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Fatores de Tempo