RESUMO
PURPOSE: To investigate the influence of CAD-CAM diamond bur deterioration on surface roughness (Ra) and maximum failure load (Lf) of Y-TZP-based ceramic (YZ) substructures (SB) veneered with a feldspathic porcelain. METHODS: Two sets of burs (B1 and B2) were used to fabricate 30 YZ SB each in a CAD/CAM system (Cerec InLab). The SB were identified (1-30) according to the milling sequence (MS). SEM images of the burs were recorded before milling, and after milling 15 and 30 SB. The SB Ra was measured. All SB were veneered, cemented onto a fiber reinforced epoxy resin die, and loaded to failure. Specimens from B1 group were cyclic fatigued (106 cycles) before loading to failure. Fractographic analysis was performed. Data were statistically analyzed using Student's t-test, Weibull analysis, Pearson's correlation and ANOVA (α= 0.05). RESULTS: The mean Ra value of B1 specimens was statistically greater than B2. Weibull modulus of B1 and B2 were statistically similar. The correlation between MS and Lf was not statistically significant for the groups. MS and Ra had significant correlation for both groups (B1: r= -0.514, P= 0.015; B2: r= -0.462, P= 0.03). Although the visual aspect (SEM) of the burs was similar after 30 millings, the mean Ra values were significantly different after 27 millings for B1 and 24 millings for B2.
Assuntos
Cerâmica/química , Desenho Assistido por Computador/instrumentação , Materiais Dentários/química , Restauração Dentária Permanente , Diamante/química , Ítrio/química , Zircônio/química , Silicatos de Alumínio/química , Cimentação/métodos , Porcelana Dentária/química , Facetas Dentárias , Módulo de Elasticidade , Resinas Epóxi/química , Vidro/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Compostos de Potássio/química , Estresse Mecânico , Propriedades de SuperfícieRESUMO
PURPOSE: To evaluate the effect of cement shade, light-curing unit, and water storage on tensile bond strength (σ) of a feldspathic ceramic resin bonded to dentin. MATERIALS AND METHODS: The dentin surface of 40 molars was exposed and etched with 37% phosphoric acid, then an adhesive system was applied. Forty blocks of feldspathic ceramic (Vita VM7) were produced. The ceramic surface was etched with 10% hydrofluoric acid for 60 s, followed by the application of a silane agent and a dual-curing resin cement (Variolink II). Ceramic blocks were cemented to the treated dentin using either A3 or transparent (Tr) shade cement that was activated using either halogen or LED light for 40 s. All blocks were stored in 37°C distilled water for 24 h before cutting to obtain non-trimmed bar-shaped specimens (adhesive area = 1 mm2 ± 0.1) for the microtensile bond strength test. The specimens were randomly grouped according to the storage time: no storage or stored for 150 days in 37°C distilled water. Eight experimental groups were obtained (n = 30). The specimens were submitted to the tensile bond strength test using a universal testing machine at a crosshead speed of 1 mm/min. The data were statistically analyzed using ANOVA and Tukey's posthoc tests (a = 0.05). RESULTS: The mean bond strength values were significantly lower for the corresponding water stored groups, except for the specimens using A3 resin cement activated by halogen light. There was no significance difference in mean bond strength values among all groups after water storage. CONCLUSION: Water storage had a detrimental effect under most experimental conditions. For both cement shades investigated (Tr and A3) under the same storage condition, the light-curing units (QTH and LED) did not affect the mean microtensile bond strengths of resin-cemented ceramic to dentin.
Assuntos
Cor , Lâmpadas de Polimerização Dentária , Colagem Dentária , Porcelana Dentária , Adesivos Dentinários , Análise de Variância , Cerâmica , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/efeitos da radiação , Humanos , Cimentos de Resina/efeitos da radiação , Estatísticas não Paramétricas , Resistência à Tração , ÁguaRESUMO
The objective of this study was to evaluate the flexural strength of denture base resin reinforced with glass fibers and with a laboratorial composite resin. Group G1 was formed with specimens made of acrylic resin. Group G2 was formed with the same acrylic resin but reinforced with a glass-fiber system, and G3 was reinforced with the composite resin. A flexural strength test was performed in all groups (n=10). The mean value for the G1 was 86.70 MPa +/- 6.48, for G2 it was 86.60 MPa +/- 15.01 and for G3 it was 108.90 + 11.03. The addition of glass fiber did not increase the flexural strength however the use of a resin-based composite produced significant reinforcement.
Assuntos
Resinas Acrílicas/química , Análise do Estresse Dentário , Bases de Dentadura , Análise de Variância , Resinas Compostas , Vidro , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Maleabilidade , Estatísticas não ParamétricasRESUMO
BACKGROUND: Syncope is a common symptom and in most cases it is of a neurally mediated origin. Such patients have to be studied with a careful history and a physical exploration that should include simple maneuvers such as blood pressure (BP) recordings in decubitus and standing position. These tools can suggest diagnosis in a good percentage of patients without the need for expensive or invasive testing. METHODS: We carried out a prospective observational study measuring BP and heart rate (HR) with the patients in decubitus and just as they stood up. The patients were sent for a tilt table test in different specialized centers. The BP changes were compared to the results of the tilt test. RESULTS: We included 215 patients, 36.1 ± 18.8 years old, 118 (54.9%) feminine, of which 143 (66.5%) had a positive tilt test. Patients with a positive test showed a rise in systolic BP (SBP) (121.7 ± 19.1 vs. 124.2 ± 20, p < 0.005) and in diastolic BP (DBP) (75 ± 11 vs. 78 ± 11.3, p < 0.005) when compared to people with a negative one. On the other hand, percentage BP changes were significantly different (SBP 2.24% vs. 0.48%, p = 0.02; DBP 4.1% vs. 1.2%, p = 0.009). Patients with a positive test had also a lower HR on standing up (72.1 ± ± 11.1 vs. 78.3 ± 17.2, p = 0.01). CONCLUSIONS: Patients with neurally mediated syncope showed an elevation of SBP and DBP when standing up actively, unlike subjects with a negative tilt test.
Assuntos
Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Postura , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Síncope Vasovagal/fisiopatologia , Fatores de Tempo , Adulto JovemRESUMO
OBJECTIVES: Evaluating the bond strength (σ) of resin cement systems (RXA - RelyX ARC; RXU - RelyX U100; and PF - Panavia F) to dentin and yttria-stabilized zirconia-based ceramic (YZ - In-Ceram YZ) after different surface treatments and aging. METHODS: Occlusal dentin of 54 human molars was exposed and conditioned following manufacturers' instructions. Fifty-four YZ blocks were sintered and divided into two groups according to surface treatment: PA - airborne particle abrasion, and SC - tribochemical silica coating. All treated YZ blocks were cemented to dentin using one of the cement systems (RXA, RXU, and PF) following manufacturers' recommendations, which includes specific silane agents. Teeth-cement-ceramic blocks were stored in 37°C distilled water for 24h before cutting into non-trimming bar-shaped specimens (adhesive area, A=1±0.1mm(2)). Specimens (n≥12) were assigned to one of the following conditions: N - no storage; W - stored in 37°C distilled water for 60days; and TC - thermal cycling (5-55°C; 10,000 cycles). All specimens were loaded in tension (F) to failure using a universal testing machine. The σ (F/A) was calculated and data were statistically analyzed using ANOVA and Tukey tests (α=0.05). Fracture surfaces were examined to determine the failure mode. RESULTS: RXA-SC and PF-PA specimens showed the greatest mean σ values after N (13.9 and 13.0MPa, respectively) and TC (12.9 and 14.8MPa, respectively). SC-treated showed greater mean σ values than PA-treated YZ specimens after W. SIGNIFICANCE: Regardless of the cement used, W and TC did not significantly reduce the σ of SC-treated YZ resin bonded to dentin.
Assuntos
Materiais Revestidos Biocompatíveis , Colagem Dentária , Análise do Estresse Dentário , Adesivos Dentinários , Cimentos de Resina , Ítrio , Zircônio , Adesividade , Abrasão Dental por Ar , Dentina , Adesivos Dentinários/química , Armazenamento de Medicamentos , Temperatura Alta , Humanos , Teste de Materiais , Cimentos de Resina/química , Silanos , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , ÁguaRESUMO
Objective: To assess the effect of simulated brushing after different treatments in color maintenance and sur-face roughness of a ceramic. Materials and methods: Thirty lithium disilicate ceramic blocks were obtained, sintered, finished with water abrasive paper grit, and divided into: Group P- polished with diamond-coated silicone tips; Group G- glaze; Group S- pigment layer and glaze. A brushing simulator machine (37 oC/120 rpm) was used (10,000; 30,000; and 100,000 cycles) and surface roughness analysis was performed before and after this simulation in a rugosimeter (Ra parame-ters - mean roughness). The samples color were assessed with a spectrophotometer (Easyshade, Vita; parameters L*a*b*). Results: Regarding surface roughness, Group P presented statistical difference after 10 years. Group G presented difference for the initial measurement, and after 1 and 3 years. Regarding color, Group P did not vary after 10 years. Group G presented difference for the initial measurement, and after 1 and 3 years; Group P did not vary after brushing, except for 1 and 10 years The initial color of Group G was similar after 1 and 3 ye-ars, however, it presented statistical difference after 10 years. Group S presented similar behavior between the initial periods from 1 to 3 years, however, the initial ?E differed statistically for 10 years. Group S were shown to be statistically different from others for all periods, ex-cept for S and P in 1 year. Conclusion: It was concluded that Group P did not suffer initial color alteration after simulated brushing, and Group G and S suffered color alteration after 10 years of simulated brushing.
RESUMO
La práctica de los deportes de alto nivel es cada vez más común. En el presente trabajo se revisa una serie de conceptos sobre la muerte súbita en atletas y cómo se puede incluir el concepto de "miocardiopatía del atleta" en el conocimiento disponible hasta la fecha. La prevalencia de muerte súbita en atletas es mayor que en la población general (1.5:100,000 contra 0.2:100,000 respectivamente). Esta diferencia puede ser secundaria a ciertos cambios miocárdicos derivados del ejercicio de resistencia. Consistentemente se han estado describiendo cambios anatómicos y funcionales de predominio ventricular derecho que semejan a una displasia arritmogénica, lo que da lugar a la hipótesis de que el ejercicio de resistencia de alto nivel puede inducir una forma de miocardiopatía que explica un cierto número de casos de muerte súbita en atletas. Los profesionales de la salud deben conocer esta posibilidad de riesgo en atletas entrenados, al tiempo que deben estimular la realización de ejercicio moderado regular como una práctica saludable en la población general.
High performance sports practice is more common every day. In the present work we evaluate several concepts regarding sudden death among athletes and the recently described "Athlete's cardiomyopathy". The prevalence of sudden death among athletes is higher than among the general population (1.5:100,000 versus 0.2:100,000 respectively). This difference can be related to myocardial changes derived from endurance exercise. There are consistent descriptions of anatomical and functional changes, more specific to the right ventricle that simulate an arrhythmogenic right ventricular dysplasia/cardiomyopathy. This can originate the hypothesis that such a cardiomyopathy can explain a certain number of sudden deaths among athletes. As healthcare professionals we have to be aware of this possibility among trained athletes, although we must continue to encourage moderate physical activity as a healthy behaviour among the general population.
RESUMO
Introdução: a exodontia é um procedimento de rotina da cirurgia bucal. Entre as complicações pós-operatórias inerentes a esse procedimento cita-se a alveolite. A etiologia desse processo não está absolutamente clara e geralmente desenvolve dor de intensidade severa entre o primeiro e quarto dias após o procedimento cirúrgico. As condições locais são caracterizadas por perda prematura ou necrose do coágulo sanguíneo e odor desagradável. A literatura relata a utilização de inúmeros medicamentos e técnicas empregadas para o seu tratamento. Objetivo: o objetivo do presente estudo foi obter maiores informações a respeito do tratamento empregado para a alveolite pelos cirurgiões dentistas da área central de Passo Fundo - RS, Brasil. Métodos: foram enviados 102 questionários e 54 foram respondidos, os quais foram analisados descritivamente. Resultados: quarenta e sete cirurgiões-dentistas afirmaram tratar alveolite, sendo a forma mais utilizada de tratamento (46,8%) a curetagem, com irrigação com soro fisiológico. Quanto à utilização de medicação local, 41 (87,2%) utilizam, sendo que o mais prevalente foi o Alveosan® (Odonto Comercial Importadora Ltda., São Paulo - SP, Brasil) (29,2%). Trinta e três profissionais (70,2 %) utilizam algum tipo de medicação sistêmica (analgésico, anti-inflamatório e antibiótico, isolados ou associados). Conclusão: Embora sabido que há di-vergências de opiniões e diversas formas de tratamento para a alveolite na literatura, todas as formas de terapêutica utilizadas pelos cirurgiões dentistas pesquisados estão dentro das relatadas na literatura, porém nemtodas são aceitáveis atualmente.
RESUMO
O esmalte dentário é o único tecido duro que não apresenta remodelação. Qualquer distúrbio que ocorra durante o processo de desenvolvimento e maturação do esmalte resulta em anomalias neste tecido. A hipoplasia do esmalte pode ser consequência de eventos sistêmicos, traumáticos, ambientais ou genéticos. De acordo com o grau de severidade desta anomalia, vários protocolos de tratamento podem ser realizados em restaurações estéticas diretas e laminados ou coroas unitárias, como clareamento, microabrasão e mega-abrasão. O objetivo deste trabalho foi relatar a condução de avaliação e tratamento de um caso clínico de hipoplasia de esmalte de uma paciente que mostrava insatisfação com tamanho e cor dos dentes anteriores. Foi realizada como resolução clínica a gengivoplastia e laminados cerâmicos nos dentes anteriores superiores.
The dental enamel is the only hard tissue that does not remodel itself. Any disorder that occurs during the enamel development and maturation process results in tissue abnormalities. Enamel hypoplasia may be a consequence of systemic, traumatic, environmental or genetic events. According to the degree of severity of this anomaly, several treatment protocols can be perfomed, from bleaching, microabrasion, megaabrasion, direct aesthetic restorations and laminates or single crows. The aim of this work is to present a clinical case of enamel hypoplasia of a patient who reported dissatisfaction with the size and color of the teeth. For this, gingivoplasty and ceramic laminates were performed on the upper anterior teeth.
Assuntos
Humanos , Feminino , Adulto , Resinas Compostas , Hipoplasia do Esmalte Dentário/terapia , Facetas Dentárias , Estética Dentária , Anormalidades Dentárias/terapiaRESUMO
Repor dentes perdidos através de implantes dentários é cotidiano nas clínicas odontológicas. O posicionamento desses implantes em posição ideal nem sempre é possível, devido às perdas ósseas e às limitações anatômicas que o paciente pode apresentar. Na maxila superior posterior a presença do seio maxilar pode ser um fator complicador para fixação dos implantes, além de que com a pneumatização do mesmo, pode evoluir a um osso muito delgado com uma fina camada cortical. Reabilitar esse tipo de paciente através de implantes pode ser impossível sem a utilização de materiais e técnicas capazes de repor parcial ou total a deficiência óssea, e suportar, em função, os implantes dentários. Atualmente, existem diversos materiais que podem ser utilizados isolados ou em conjunto com outros para levantamento do assoalho do seio maxilar, podendo deixar o cirurgião dentista em dúvida de qual material escolher para cada caso. Esta revisão tem como objetivo transcorrer sobre os materiais de enxertia disponíveis no mercado, baseado em evidências científicas, a fim de esclarecer para o cirurgião quais os substitutos ósseos disponíveis para utilização desse tipo de enxertia...
The treatment with dental implants after teeth loss has become a common practice in dentistry. However, the appropriate implant positioning can be compromised by bone resorption and anatomical limitations presented by mandible/maxilla. The presence of maxillary sinus on posterior region of an edentulous maxilla can hinder maxillary implants, mainly when sinus pneumatization occurs, leading to an insufficient volume of healthy bone for implantÆs placement. Oral rehabilitation with dental implants in such cases may not be executed without previous reconstructive surgical techniques associated to materials that will be able to create adequate bone volume for implant sites. Several materials are available and can be used alone or combined for maxillary sinus floor elevation. Thus their indications should be clarified aiming to guide dental surgeons. This literature review aims to discourse about marketed grafting materials, based on scientific evidence, clarifying which materials are the available for bone replacement on sinus lift...
Assuntos
Humanos , Levantamento do Assoalho do Seio Maxilar/métodos , Seio Maxilar/cirurgia , Transplante Ósseo/métodos , Materiais Biocompatíveis/química , Radiografia Panorâmica/instrumentaçãoRESUMO
Avaliar a resistência da união adesiva, pelo ensaio de microtração, de bases para próteses totais confeccionadas com resina acrílica ativada termicamente (Lucitone 550 - Dentsply) a dentes artificiais de resina acrílica (Biotone - Dentsply), submetidos a diferentes condições pós-prensagem e períodos de armazenagem.Metodologia: foram confeccionados 32 conjuntos dente/base de resina acrílica, separados em quatro grupos (n=8) conforme o tempo pós-prensagem até a acrilização (imediatamente após ou 24 h após a prensagem) e período de armazenagem em água destilada (24 horas ou 30 dias, em água destilada à 37°C). Sendo assim, 4 grupos foram formados: G1 (Imediato; -sem armazenagem); G2 (Mediato - sem armazenagem); G3 (Imediato - com armazenagem); e G4 (Mediato - com armazenagem). Os conjuntos dente/base de resina foram seccionados em dois eixos, x e y, com um disco diamantado sob irrigação constante (área adesiva - 1mm2) obtendo-se aproximadamente 96 corpos de prova (cp) por grupo. Imediatamente após o corte, os cp foram fixados em um dispositivo de microtração acoplado a uma máquina de ensaio universal (EMIC-DL-1000, Brasil) e testado com velocidade de 1mm/min. Os dados foram submetidos ao teste Anova e Tukey (=0,05).Resultado: os valores médios (MPa) obtidos foram: G1: 27,82 ±12,68, G2: 29,92 ±13,73, G3 30,09 ±20,48 e G4: 32,51±13,81.Conclusão: as diferentes condições pós-prensagem e períodos de armazenagem não influenciaram na resistência de união adesiva dente/base de resina...
The objective of this study was to compare the tensile bond strengths by the micro tensile test of conventional heat-cured resin denture (Lucitone 550 DENTSPLY) with acrylic resin denture teeth (Biotone DENTSPLY), submit in a different polymerization cycle and storage.Methodology: thirty two specimens were fabricated and divided in four groups (n=8): G1 (immediate; without storage); G2 (mediate; without storage); G3 (immediate; with storage); G4 (mediate; with storage). Theses specimens was storage in distilled water until testing and cut in two axis, X and Y, with a diamond disc, getting 12 specimens with ± 1 mm² of adhesive area. The specimens were fixed in a specific device that was fixed in a universal testing machine (EMIC-DL-1000, Brazil) and tested with a cross-speed 1 mm/min.Results: the microtensile bond strengths values was G1 (27,82 ±12,68), G2 (29,92 ±13,73), G3 (30,09 ±20,48) e G4 (32,51±13,81).Conclusion: within the limitations of this study, there no was difference between these groups...
Assuntos
Humanos , Colagem Dentária/métodos , Resinas Acrílicas/química , Dente Artificial , Teste de Materiais , Polimerização , Reprodutibilidade dos Testes , Propriedades de Superfície , Resistência à Tração , Fatores de TempoRESUMO
Fraturas complexas de incisivos centrais são situações clínicas que requerem uma abordagem imediata, principalmente devido ao apelo estético. A utilização do próprio fragmento fraturado constitui uma ótima alternativa para restauração provisória, permitindo um estudo mais detalhado do caso. Caso a opção seja extração e instalação de um implante imediato, esse fragmento também poderá ser utilizado na restauração provisória sobre implante, o que auxilia na manutenção do contorno gengival. Sendo assim, a proposta desse artigo é relatar um caso clínico com um ano de acompanhamento de uma reabilitação com implante na região de incisivo central superior após fratura do elemento dentário por trauma, utilizando o fragmento fraturado para os procedimentos restauradores provisórios.
Complex fractures of central incisors are clinical situations which require immediate approach, mainly due to aesthetic issues. The fractured fragment itself is a great alternative to temporary restoration, allowing a detailed study of the case. When the chosen approach is the extraction of the tooth and immediate implant installation, this fragment can also be used for temporary restoration on implant, which is helpful for maintaining the gingival anatomy. Thus, the aim of this article was to report a case with one year follow-up of implant rehabilitation at the maxillary central incisor region after tooth fracture by trauma, using the fractured fragment for temporary restorative procedures
Assuntos
Humanos , Masculino , Adulto , Carga Imediata em Implante Dentário , Estética Dentária , Extração Dentária , Implantes Dentários , Planejamento de Dentadura/métodos , Prótese Dentária Fixada por Implante , Reabilitação Bucal/instrumentação , Reabilitação BucalRESUMO
Data were collected by surveying all the technicians that worked at the different primary and secondary health care units. A quality control was carried out in the diagnosis of paludism in the 18 laboratories of the province of Cienfuegos. Various parameters were controlled. The method A considered 4 aspects to be evaluated: preparation of the material, sample taking, staining and microscopy. The method B consisted in an efficiency test by the observation of a set of laminae negative and positive to Plasmodium vivax and Plasmodium falciparum. In both cases, it was established a scoring scale. Besides, the physical conditions of the laboratory, the personnel permanence, as well as the time of experience in the diagnosis of paludism, were taken into account. The best results were obtained with the fixed personnel working in the paludism section. It was proved with a statistical significance level that the good category predominated for methods A and B after evaluating all the technicians. The study showed a better preparation of the personnel with less than 5 years of experience, which was related to the participation in the training course conducted at the provincial level by "Pedro Kouri" Tropical Medicine Institute 6 months before the investigation. Deficiencies were found in the conditions of the clinical and microbiology laboratories.
Assuntos
Malária/diagnóstico , Controle de Qualidade , Técnicas de Laboratório Clínico/normas , Cuba , Humanos , Parasitologia/normasRESUMO
Objetivou-se, neste trabalho, avaliar os rendimentos agrícola e forrageiro de três cultivares de cana-de-açúcar em diferentes épocas de corte (maio, julho e setembro), onde há uma maior demanda de forragem na região. O experimento foi instalado no município de Lavras, Minas Gerais. O clima é do tipo mesotérmico e o solo é um Latossolo Vermelho Escuro. O delineamento experimental utilizado foi o de blocos casualizados, em esquema fatorial 3 X 3, com 3 repetições. Os tratamentos foram constituídos por três cultivares de cana-de-açúcar (RB825336; SP80-1816 e RB835054) e por três épocas de corte (maio; julho; setembro). Cada parcela foi constituída por 6 linhas de cana-de-açúcar, espaçadas de 1,25m, com 8m de comprimento, com uma área total de 60m². A área útil de parcela correspondeu às quatro linhas centrais, eliminando-se 1,0m de cada extremidade, com uma área de 30,0m². Foram avaliados os rendimentos de massa verde, massa seca, tonelada de colmos por hectare e sacarose (g/100g caldo). Os resultados mostraram que não houve efeitos de cultivares e das épocas de corte estudadas nos rendimentos dos colmos, massa verde, matéria seca e sacarose da cana-de-açúcar. Os altos rendimentos obtidos para massa verde e matéria seca, no período de seca (maio a setembro), mostram o grande potencial da cana-de-açúcar para uso na alimentação do rebanho leiteiro na região.
Our main goal in this study was to evaluate the agricultural and forage yields of three sugarcane cultivars at different cutting times (May, July and September), when there is a larger demand for forage in the region. The experiment was installed in the municipal district of Lavras, Minas Gerais. The climate is of the mesothermic type, and the soil is a Dark Red Latossolo. The experimental delineation used was of casualized blocks in 3 X 3 factorial design, with 3 repetitions. The treatments consisted of three cultivars of sugarcane (RB825336; SP80-1816; and RB835054) and three cutting times (May; July; September). Each plot consisted of 6 sugarcane rows, spaced at 1,25m, with 8m of length, and with a total area of 60m². The useful area corresponded to the four central rows, 1,0m of each extremity being eliminated, with an area of 30,0m². Green mass, dry mass, stems per hectare, and sucrose (g/100g broth) were appraised. The results showed that the cultivars and the cutting times studied had no effect on the yields of the stems, green mass, dry mass, and sugarcane sucrose (broth). The high yields obtained for green mass and dry matter, during the drought period (May to September), show the great potential of sugarcane for use in dairy cattle feeding in the area.
RESUMO
Objetivou-se avaliar o efeito de métodos de envelhecimento na resistência adesiva ( σ) de três sistemas de cimentação resinosa de ativação dual (RXA- RelyX ARC, RXU- RelyX U100 e PF- PanaviaF) entre a dentina e uma cerâmica à base de zircônia estabilizada poróxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície dentinária oclusal de 72 molares humanos hígidos foi exposta e condicionada conforme as instruções dos fabricantes. Os blocos cerâmicos (72) foram cortados,planificados, sinterizados e divididos em dois grupos conforme o tipo de tratamento de superfície: PA- jateamento com óxido de alumínio (≤45μm) ou SC- silicatização (Rocatec Soft, 3M ESPE). A cimentação dos blocos cerâmicos foi realizada de acordo com as instruções dos fabricantes, constituindo 6 grupos que foram armazenados em água destilada à 37°C por 24 h. Os conjuntos dente-cimento resinoso cerâmica foram cortados no sentido x e y, produzindo,aproximadamente, 9 corpos de prova (cp) em forma de barra (área adesiva de 0,9 ± 0,1 mm2) por conjunto. Os cp de cada grupo foram divididos aleatoriamente em 4 condições de envelhecimento:armazenagem em água destilada (A) a 37oC por 120 ou 180 dias (d); etermociclagem com 30.000x ou 60.000x (5ºC-55ºC); constituindo 24 grupos (n>12). O teste de micro-tração foi realizado em uma máquina de ensaio universal (1 mm/min). A σ foi calculada e os dados foram analisados estatisticamente através da ANOVA e teste de Tukey(α=0,05). Os grupos RXA-SC 180 d e PF-PA 120 d apresentaram os mais altos valores de σ (32,9 e 29,6 MPa, respectivamente). Os grupos RXA-PA 30.000x (8,9 MPa) e RXU-SC 180 d (8,1 MPa) mostraram os valores mais baixos de σ. O envelhecimento por TC não prejudicou qualquer dos grupos experimentais, mas o envelhecimento por A reduziu significativamente os valores de σ nos grupos RXU-SC e PF-PA.
The aim of this study was to evaluate the bond strength (σ) of resincement systems (RXA- RelyX ARC; RXU- RelyX U100; and PFPanaviaF) to dentin and yttria-stabilized zirconia-based ceramic (YZIn-Ceram YZ) after different surface treatments and aging. The occlusal dentin of 72 sound human molars was exposed and conditioned according to the manufacturers instructions. Ceramic blocks (72) were cut, flattened, sintered, and divided into two groups according to the type of surface treatment: PA- airborne particle abrasion (≤ 45μm alumina particles), and SC- tribochemical silica coating (Rocatec Soft, 3M ESPE). The cementation procedure followed the instructions of each manufacturer, resulting in 6 groups of tooth-cement-ceramic blocks that were stored in 37°C distilled water for 24 h before cutting into nontrimmed bar-shaped specimens (A- adhesive area= 0.9 ± 0.1 mm²).Approximately 9 specimens per block were obtained and they were randomly assigned to one of the 4 aging conditions: 120 or 180 days stored in 37oC distilled water; and thermocycling (5ºC-55ºC) with 30,000 or 60,000 cycles. The experimental design resulted in 24 groups (n>12).The specimens were loaded in tension (F) until failure using a universal testing machine (crosshead speed: 1 mm/min). The σ (F/A) was calculated and data was statistically analyzed using ANOVA and Tukey tests (α=0.05). Groups RXA-SC 180 d and PF-PA 120 d showed the highest σ values (32.9 and 29.6 MPa, respectively). Groups RXA-PA30,000x (8.9 MPa) and RXU-SC 180 d (8.1 MPa) presented the lowest σ values. Thermocycling did not reduce the σ values of any experimental group, but water storage decreased the σ values for RXU-SC and PF-PA groups.
Assuntos
Cerâmica , Cimentos Dentários , Resistência à Tração , DentinaRESUMO
Objetivou-se avaliar o efeito de métodos de envelhecimento na resistência adesiva ( σ) de três sistemas de cimentação resinosa de ativação dual (RXA- RelyX ARC, RXU- RelyX U100 e PF- PanaviaF) entre a dentina e uma cerâmica à base de zircônia estabilizada poróxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície dentinária oclusal de 72 molares humanos hígidos foi exposta e condicionada conforme as instruções dos fabricantes. Os blocos cerâmicos (72) foram cortados,planificados, sinterizados e divididos em dois grupos conforme o tipo de tratamento de superfície: PA- jateamento com óxido de alumínio (≤45μm) ou SC- silicatização (Rocatec Soft, 3M ESPE). A cimentação dos blocos cerâmicos foi realizada de acordo com as instruções dos fabricantes, constituindo 6 grupos que foram armazenados em água destilada à 37°C por 24 h. Os conjuntos dente-cimento resinoso cerâmica foram cortados no sentido x e y, produzindo,aproximadamente, 9 corpos de prova (cp) em forma de barra (área adesiva de 0,9 ± 0,1 mm2) por conjunto. Os cp de cada grupo foram divididos aleatoriamente em 4 condições de envelhecimento:armazenagem em água destilada (A) a 37oC por 120 ou 180 dias (d); etermociclagem com 30.000x ou 60.000x (5ºC-55ºC); constituindo 24 grupos (n>12). O teste de micro-tração foi realizado em uma máquina de ensaio universal (1 mm/min). A σ foi calculada e os dados foram analisados estatisticamente através da ANOVA e teste de Tukey(α=0,05). Os grupos RXA-SC 180 d e PF-PA 120 d apresentaram os mais altos valores de σ (32,9 e 29,6 MPa, respectivamente). Os grupos RXA-PA 30.000x (8,9 MPa) e RXU-SC 180 d (8,1 MPa) mostraram os valores mais baixos de σ. O envelhecimento por TC não prejudicou qualquer dos grupos experimentais, mas o envelhecimento por A reduziu significativamente os valores de σ nos grupos RXU-SC e PF-PA
The aim of this study was to evaluate the bond strength (σ) of resincement systems (RXA- RelyX ARC; RXU- RelyX U100; and PFPanaviaF) to dentin and yttria-stabilized zirconia-based ceramic (YZIn-Ceram YZ) after different surface treatments and aging. The occlusal dentin of 72 sound human molars was exposed and conditioned according to the manufacturers instructions. Ceramic blocks (72) were cut, flattened, sintered, and divided into two groups according to the type of surface treatment: PA- airborne particle abrasion (≤ 45μm alumina particles), and SC- tribochemical silica coating (Rocatec Soft, 3M ESPE). The cementation procedure followed the instructions of each manufacturer, resulting in 6 groups of tooth-cement-ceramic blocks that were stored in 37°C distilled water for 24 h before cutting into nontrimmed bar-shaped specimens (A- adhesive area= 0.9 ± 0.1 mm²).Approximately 9 specimens per block were obtained and they were randomly assigned to one of the 4 aging conditions: 120 or 180 days stored in 37oC distilled water; and thermocycling (5ºC-55ºC) with 30,000 or 60,000 cycles. The experimental design resulted in 24 groups (n>12).The specimens were loaded in tension (F) until failure using a universal testing machine (crosshead speed: 1 mm/min). The σ (F/A) was calculated and data was statistically analyzed using ANOVA and Tukey tests (α=0.05). Groups RXA-SC 180 d and PF-PA 120 d showed the highest σ values (32.9 and 29.6 MPa, respectively). Groups RXA-PA30,000x (8.9 MPa) and RXU-SC 180 d (8.1 MPa) presented the lowest σ values. Thermocycling did not reduce the σ values of any experimental group, but water storage decreased the σ values for RXU-SC and PF-PA groups
Assuntos
Cerâmica , Cimentos Dentários , Resistência à Tração , DentinaRESUMO
Objetivo: investigar as características físicas dos fios de sutura freqüentemente usados na odontologia. Material e Método: Fios (n=10) de seda (FS) 4-0 e nylon (FN) 4-0 (Somerville Ltda.) foram testados de acordo com a norma NBR 13904:2003. O comprimento foi determinado com escala rígida, sem tensionar o fio. O diâmetro foi avaliado utilizandoum metroscópio e um relógio comparador digital. As cargas de ruptura em tração sobre nó (Lno) e ao encastoamento (Lf) foram testados em uma máquina de ensaio universal com velocidade de 1mm/min. Os resultados foram analisados estatisticamente pelo teste t de Student (α = 0,05). Resultados: Todos os fios cumpriram com as especificações quantoao comprimento. Os FN apresentaram um valor médio de diâmetro de 0,17 mm, contudo os FS apresentaram um valor médio de 0,21 mm, ficando fora da faixa específica (0,15-0,199 mm). Valores médios de Lno foram significativamente maiores para os FS (7,54 ± 0,50 N) do que para os FN (6,67 ± 0,83 N) (p<0,05). Todos os fios resistiram ao teste de encastoamento com valores acima dos limites individual e médio mínimos preconizados, respectivamente 2,26 N e 4,41 N, sendo que os valores médios de FS (8,98 ± 2,16 N) foram significativamente maiores do que os FN (7,27 ±1,31 N) (p<0,05). Conclusão: Essas diferenças podem ter sido induzidas pelo maior diâmetro dos FS, pois assumindoos valores médios de diâmetro e carga obtem-se valores de resistência a tração sobre nó (σno) de 203,8 MPa para os FSe 277,9 MPa para os FN.
Assuntos
Materiais Dentários , Suturas , Teste de MateriaisRESUMO
Objetivou-se avaliar in vitro a resiliência de dois condicionadores de tecido, UG - Ufigel SC (Voco) e D - Dentusoft (DMG), depois de serem submetidos a diferentes tempos de armazenamento em água destilada a 37ºC (24 horas, 14 dias, 30 dias e 180 dias). Foram confeccionadas 20 cápsulas de resina acrílica termicamente ativada, com 20 mm de diâmetro interno e 3 mm de profundidade. Os condicionadores de tecido, UG e D, foram manipulados de acordo com o fabricante, acomodados no interior das cápsulas (n = 10) e armazenados por 24 horas, 14 dias, 30 dias e 180 dias. Cada grupo foi submetido ao teste de resiliência utilizando uma ponta romba de 3 mm de diâmetro em máquina de ensaio universal (EMIC-DL 1000). Os dados foram submetidos à análise estatística two-way ANOVA e ao teste de Tukey (α = 0,05). Os valores de média para os materiais/tempo de armazenagem foram: UG/24 horas - 3,81A; D/30 dias - 5,54B; UG/14 dias - 5,58B; UG/30 dias - 5,66BC; UG/180 dias - 5,77BC; D/24 horas - 5,79BC; D/180 dias - 6,13C; D/14 dias - 6,54D. Dentusoft armazenado por 14 dias obteve valores de média de resiliência significantemente superiores em relação aos demais. Ufigel armazenado nos períodos de 1 a 14 dias apresentaram valores de resiliência menores do que D, sendo estatisticamente significante nesses períodos. Entretanto, para os períodos de avaliação de 30 e 180 dias, não se observaram diferenças significantes entre os materiais.
Assuntos
Resinas Acrílicas , Reembasadores de Dentadura , Técnicas In Vitro , Próteses e Implantes , Materiais Dentários , Silicones , Interpretação Estatística de DadosRESUMO
Se realizó un control sobre la calidad en el diagnóstico de paludismo en los 18 laboratorios de la provincia Cienfuegos. Se recogieron los datos en un modelo de encuesta aplicado a todos los técnicos que trabajaban en las distintas unidades de salud, tanto de la atención primaria como secundaria. Se controlaron varios parámetros. El método que se denominó A, consideró 4 aspectos a evaluar: preparación del material, toma de la muestra, coloración y microscopia. El que se denominó B consistió en una prueba de eficiencia, mediante la observación de juegos de láminas negativas y positivas a Plasmodium vivax y Plasmodium falciparum. En ambos casos se estableció una escala de puntuación. Además, se tuvieron en cuenta las condiciones físicas de los laboratorios y la permanencia del personal, así como tiempo de experiencia en el diagnóstico de paludismo. Los mejores resultados se obtuvieron dentro del personal que laboraba fijo en la sección de paludismo. Se demostró con un nivel de significación estadística, que para los métodos A y B predominó la categoría de bien, después de evaluar a todos los técnicos. El estudio mostró mejor preparación del personal con menos de 5 años de experiencia, lo cual se relacionó con la participación en el curso de superación impartido en la provincia por el Instituto de Medicina Tropical (IPK), 6 meses antes de la investigación. Los resultados muestran deficiencias en las condiciones de los laboratorios, tanto en los clínicos como en los de microbiología(AU)
Assuntos
Controle de Qualidade , Malária/diagnóstico , Cuba , Monitoramento Epidemiológico , Técnicas de Laboratório Clínico/normasRESUMO
Se realizó un control sobre la calidad en el diagnóstico de paludismo en los 18 laboratorios de la provincia Cienfuegos. Se recogieron los datos en un modelo de encuesta aplicado a todos los técnicos que trabajaban en las distintas unidades de salud, tanto de la atención primaria como secundaria. Se controlaron varios parámetros. El método que se denominó A, consideró 4 aspectos a evaluar: preparación del material, toma de la muestra, coloración y microscopia. El que se denominó B consistió en una prueba de eficiencia, mediante la observación de juegos de láminas negativas y positivas a Plasmodium vivax y Plasmodium falciparum. En ambos casos se estableció una escala de puntuación. Además, se tuvieron en cuenta las condiciones físicas de los laboratorios y la permanencia del personal, así como tiempo de experiencia en el diagnóstico de paludismo. Los mejores resultados se obtuvieron dentro del personal que laboraba fijo en la sección de paludismo. Se demostró con un nivel de significación estadística, que para los métodos A y B predominó la categoría de bien, después de evaluar a todos los técnicos. El estudio mostró mejor preparación del personal con menos de 5 años de experiencia, lo cual se relacionó con la participación en el curso de superación impartido en la provincia por el Instituto de Medicina Tropical (IPK), 6 meses antes de la investigación. Los resultados muestran deficiencias en las condiciones de los laboratorios, tanto en los clínicos como en los de microbiología