Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Int J Lab Hematol ; 45(1): 96-103, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36168666

RESUMO

INTRODUCTION: The Thomas-plot has proven to be a helpful tool to discriminate between different types of anemia. This plot combines the reticulocyte hemoglobin content (Ret-He) with the soluble transferrin receptor (sTfR)/log ferritin (fer) ratio. In this study, we designed an alternative Thomas-plot in which Ret-He is combined with the transferrin (Tf)/log ferritin ratio. We validated both Thomas-plots in a population of anemic patients and compared the performance to the current laboratory diagnostics of anemia. METHODS: A total of 536 anemic patients were included. The first 188 patients were used to generate ROC curves to define the optimal cut-off values for both Thomas-plots. With the following 348 patients included we studied the performance of the alternative and classical Thomas-plots compared to current anemia diagnostics. RESULTS: Cut-off values were defined (Ret-He: 31.2 pg, sTfR/log(fer): 0.91, and Tf/log(fer): 1.71). With both Thomas-plots the amount of e causa ignota (ECI) cases dropped from 39% to 27%. A more in depth analysis on the iron status of anemia of chronic disease (ACD) patients and a subdivision between latent and classical iron deficiencies could be made with the help of both plots. A shift from classical iron deficiency anemia (IDA) cases according to the classical Thomas-plot toward functional IDA according to the alternative Thomas-plot was observed. CONCLUSION: The alternative Thomas-plot is an effective tool that gives a more in depth view on the iron status of anemic patients. In addition, it is easier to implement due to the use of transferrin rather than the soluble transferrin receptor.


Assuntos
Anemia Ferropriva , Anemia , Humanos , Anemia/diagnóstico , Ferro/metabolismo , Anemia Ferropriva/diagnóstico , Ferritinas , Hemoglobinas/análise , Transferrina , Receptores da Transferrina , Doença Crônica
3.
World J Gastroenterol ; 12(17): 2779-80, 2006 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-16718769

RESUMO

AIM: To evaluate the novel anti-endomysium (anti-EMA) detection based on ELISA. METHODS: Anti-EMA IgA was measured by a novel ELISA in 196 patients with gastrointestinal symptoms and suspected mal-absorption. Data were compared with those obtained by the conventional IF test. RESULTS: A good concordance of 98% was found between these two assays. In sera of 161 patients (82%) both assays tested negative whereas in sera of 31 patients (16%) both assays tested positive for the presence of anti-EMA antibodies. Discrepancies between EMA-ELISA and EMA-immunofluorescence (IF) were found in only 4 patients (2%). CONCLUSION: This ELISA can replace IF for the detection of anti-EMA antibodies and provide clinicians with an excellent tool to screen for celiac disease in patients with gastrointestinal complaints.


Assuntos
Anticorpos Anti-Idiotípicos/sangue , Doença Celíaca/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Imunofluorescência/métodos , Imunoglobulina A/sangue , Reticulina/imunologia , Anticorpos Anti-Idiotípicos/imunologia , Doença Celíaca/sangue , Humanos , Imunoglobulina A/imunologia , Fibras Musculares Esqueléticas/imunologia , Nefelometria e Turbidimetria/métodos , Sensibilidade e Especificidade
4.
J Lab Autom ; 20(6): 670-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25925737

RESUMO

Differential counting of peripheral blood cells is an important diagnostic tool. However, manual morphological analysis using the microscope is time-consuming and requires highly trained personnel. The digital microscope is capable of performing an automated peripheral blood cell differential, which is as reliable as manual classification by experienced laboratory technicians. To date, information concerning the interlaboratory variation and quality of cell classification by independently operated digital microscopy systems is limited. We compared four independently operated digital microscope systems for their ability in classifying the five main peripheral blood cell classes and detection of blast cells in 200 randomly selected samples. Set against the averaged results, the R(2) values for neutrophils ranged between 0.90 and 0.96, for lymphocytes between 0.83 and 0.94, for monocytes between 0.77 and 0.82, for eosinophils between 0.70 and 0.78, and for blast cells between 0.94 and 0.99. The R(2) values for the basophils were between 0.28 and 0.34. This study shows that independently operated digital microscopy systems yield reproducible preclassification results when determining the percentages of neutrophils, eosinophils, lymphocytes, monocytes, and blast cells in a peripheral blood smear. Detection of basophils was hampered by the low incidence of this cell class in the samples.


Assuntos
Células Sanguíneas/classificação , Células Sanguíneas/citologia , Citometria por Imagem/métodos , Microscopia/métodos , Humanos , Citometria por Imagem/instrumentação , Processamento de Imagem Assistida por Computador , Microscopia/instrumentação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa