Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Thorac Oncol ; 11(8): 1293-1304, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27262212

RESUMO

INTRODUCTION: Mesenchymal-epithelial transition factor gene (MET) gene copy number gain may be a predictive biomarker for mesenchymal-epithelial transition factor (MET) inhibition in lung cancer, but the most appropriate method and criteria for defining MET positivity are uncertain. METHODS: MET copy number was assessed by fluorescence in situ hybridization in lung adenocarcinoma. Positivity criteria included mean MET per cell values greater than 5 (low [≥5 to <6], intermediate [≥6 to <7], and high [≥7]) and mean MET-to-chromosome 7 centromere ratios (MET/CEP7) of at least 1.8 (low [≥1.8 to ≤2.2], intermediate [>2.2 to <5], and high [≥5]). Associated clinical and molecular characteristics were captured. RESULTS: Of 686 cases, 99 (14%) had a mean MET per cell value of 5 or greater, 52 of 1164 (4.5%) had a MET/CEP7 ratio of 1.8 or higher. Other oncogenic drivers (in EGFR, KRAS, anaplastic lymphoma receptor tyrosine kinase gene [ALK], erb-b2 receptor tyrosine kinase 2 gene [ERBB2], BRAF, NRAS, ROS1, or ret proto-oncogene [RET]) were detectable in 56% of the group with a mean MET per cell value of 5 or higher and 47% of the group with a MET/CEP7 ratio of 1.8 or higher, suggesting that many MET-positive cases are not truly MET addicted. The rates of concomitant drivers in the groups of patients in the low, indeterminate, and high categories of mean MET per cell were 32 of 52 (62%), 12 of 19 (63%), and 11 of 27 (41%) (p = 0.2), and the rates of concomitant drivers in the low, intermediate, and high categories of MET/CEP7 ratios were 15 of 29 (52%), 9 of 18 (50%), and 0 of 4 (0%), respectively (p = 0.04). A MET/CEP7 ratio of 1.8 or higher in the absence of other oncogenes was associated with a higher rate of adrenal metastases (p = 0.03) but not with never-smoking status. CONCLUSIONS: A fluorescence in situ hybridization MET/CEP7 ratio of 5 or higher defined a "MET-positive" group with no oncogenic overlap. As this method and criteria are also associated with the highest response rate to MET inhibition, it represents the clearest definition of a MET copy number gain-addicted state. However, a MET-associated phenotype may also exist across cases with a MET/CEP7 of 1.8 or higher when no other oncogene overlap occurs.


Assuntos
Adenocarcinoma/genética , Dosagem de Genes , Hibridização in Situ Fluorescente/métodos , Neoplasias Pulmonares/genética , Oncogenes , Proteínas Proto-Oncogênicas c-met/genética , Adenocarcinoma de Pulmão , Centrossomo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proto-Oncogene Mas , Estudos Retrospectivos
2.
Arch Pathol Lab Med ; 140(11): 1206-1220, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27610643

RESUMO

Context .- In an era in which testing of patient tumor material for molecular and other ancillary studies is of increasing clinical importance for selection of therapy, the ability to test on small samplings becomes critical. Often, small samplings are rapidly depleted in the diagnostic workup or are insufficient for multiple ancillary testing approaches. Objective .- To describe technical methodologies that can be implemented to preserve and maximize tissue for molecular and other ancillary testing. Data Sources .- Retrospective analysis of a case cohort from the University of Colorado, description of techniques used at the University of Colorado, and published literature. Conclusions .- Numerous techniques can be deployed to maximize molecular and other ancillary testing, even when specimens are from small samplings. A dedicated process for molecular prioritization has a high success rate, but also increases workload, which must be factored into establishing such a process. Additionally, establishing high-fidelity communication strings is critical for success of dedicated molecular prioritization of samples. Numerous approaches can be deployed for alternative specimen types, and several technical approaches can also aid in maximizing small specimens.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa