1.
PLoS One ; 12(4): e0174922, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28384210

RESUMO

The ultrasonic treatment of varicose veins uses high-intensity focused ultrasound, in which a blood vessel is contracted by converting acoustic energy into thermal energy. In this study, we propose a phantom of varicose veins that can be applied for the efficient evaluation of ultrasonic treatment in varicose veins. The proposed phantom consisted of glycerol base tissue equivalent material, vessel mimic tube, and blood mimic substances. The vessel mimic tube was placed inner glycerol phantom and it was filled with blood mimic substances. Blood-mimicked substances are prepared by adjusting the concentration of the glycerol solution to be similar to the acoustic properties of the blood, and vessel-mimicking materials are selected by measuring acoustic properties and thermal shrinkage of various materials in a heat-shrinkable tube. The blood vessels surrounding the tissue are replaced with the phantom similar to glycerol-based organization, and venous blood flow is implemented using a DC motor. The heating characteristics according to the ultrasonic wave using the manufactured varicose veins phantom were evaluated. As the sound wave irradiation time and power increased, the contractility of the vessel mimicking materials and the temperature of the surrounding tissues were increased. When the blood-mimicking material was circulated, the highest temperature in the focused region and the contractility of vessel mimicking materials were reduced under the same conditions as used for sonication. The manufactured phantom may contribute to the treatment of varicose veins and can be used to predict the ultrasonic therapeutic efficiency of varicose veins.


Assuntos
Imagens de Fantasmas , Terapia por Ultrassom , Varizes/terapia , Humanos , Hipertermia Induzida
2.
Artigo em Inglês | MEDLINE | ID: mdl-18002706

RESUMO

The infrared diagnosis device provides two-dimensional images and patient-oriented results that can be easily understood by the inspection target by using infrared cameras; however, it has disadvantages such as large size, high price, and inconvenient maintenance. In this regard, this study has proposed small-sized diagnosis device for body heat using a single infrared sensor and implemented an infrared detection system using a single infrared sensor and an algorithm that represents thermography using the obtained data on the temperature of the point source. The developed systems had the temperature resolution of 0.1 degree and the reproducibility of +/-0.1 degree. The accuracy was 90.39% at the error bound of +/-0 degree and 99.98% at that of +/-0.1 degree. In order to evaluate the proposed algorithm and system, the infrared images of camera method was compared. The thermal images that have clinical meaning were obtained from a patient who has lesion to verify its clinical applicability.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Termografia/instrumentação , Termografia/métodos , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Raios Infravermelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade