Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Molecules ; 28(12)2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37375176

RESUMO

Regulation of the sodium cations level in the case of renal failure diseases is a very challenging task for clinicians, and new pollutant extractors based on nanomaterials are emerging as potential treatments. In this work, we report different strategies for the chemical functionalization of biocompatible large pore mesoporous silica, denoted stellate mesoporous silica (STMS), with chelating ligands able to selectively capture sodium. We address efficient methods to covalently graft highly chelating macrocycles onto STMS NPs such as crown ethers (CE) and cryptands (C221) through complementary carbodiimidation reactions. Regarding sodium capture in water, C221 cryptand-grafted STMS showed better capture efficiency than CE-STMS due to higher sodium atom chelation in the cryptand cage (Na+ coverage of 15.5% vs. 3.7%). The sodium selectivity was hence tested with C221 cryptand-grafted STMS in a multi-element aqueous solution (metallic cations with the same concentration) and in a solution mimicking peritoneal dialysis solution. Results obtained indicate that C221 cryptand-grafted STMS are relevant nanomaterials to extract sodium cations in such media and allow us to regulate their levels.

2.
Int J Mol Sci ; 23(12)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35742850

RESUMO

Chronic kidney disease (CKD) frequently leads to hyperphosphatemia and hyperparathyroidism, mineral bone disorder (CKD-MBD), ectopic calcifications and cardiovascular mortality. PTH activates the osteoanabolic Gαs/PKA and the Gαq/11/PKC pathways in osteoblasts, the specific impact of the latter in CKD-MBD is unknown. We generated osteoblast specific Gαq/11 knockout (KO) mice and established CKD-MBD by subtotal nephrectomy and dietary phosphate load. Bone morphology was assessed by micro-CT, osteoblast function by bone planar scintigraphy at week 10 and 22 and by histomorphometry. Osteoblasts isolated from Gαq/11 KO mice increased cAMP but not IP3 in response to PTH 1-34, demonstrating the specific KO of the PKC signaling pathway. Osteoblast specific Gαq/11 KO mice exhibited increased serum calcium and reduced bone cortical thickness and mineral density at 24 weeks. CKD Gαq/11 KO mice had similar bone morphology compared to WT, while CKD Gαq/11-KO on high phosphate diet developed decreased metaphyseal and diaphyseal cortical thickness and area, as well as a reduction in trabecular number. Gαq/11-KO increased bone scintigraphic tracer uptake at week 10 and mitigated tracer uptake in CKD mice at week 22. Histological bone parameters indicated similar trends. Gαq/11-KO in osteoblast modulates calcium homeostasis, bone formation rate, bone morphometry, and bone mineral density. In CKD and high dietary phosphate intake, osteoblast Gαq/11/PKC KO further aggravates mineral bone disease.


Assuntos
Doenças Ósseas , Distúrbio Mineral e Ósseo na Doença Renal Crônica , Insuficiência Renal Crônica , Animais , Densidade Óssea , Cálcio , Osso Cortical/diagnóstico por imagem , Osso Cortical/metabolismo , Camundongos , Camundongos Knockout , Osteoblastos/metabolismo , Hormônio Paratireóideo , Fosfatos , Insuficiência Renal Crônica/metabolismo , Transdução de Sinais
3.
Molecules ; 26(4)2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33673084

RESUMO

The controlled design of robust, well reproducible, and functional nanomaterials made according to simple processes is of key importance to envision future applications. In the field of porous materials, tuning nanoparticle features such as specific area, pore size and morphology by adjusting simple parameters such as pH, temperature or solvent is highly needed. In this work, we address the tunable control of the pore morphology of mesoporous silica (MS) nanoparticles (NPs) with the sol-gel reaction temperature (Tsg). We show that the pore morphology of MS NPs alone or of MS shell covering iron oxide nanoparticles (IO NPs) can be easily tailored with Tsg orienting either towards stellar (ST) morphology (large radial pore of around 10 nm) below 80 °C or towards a worm-like (WL) morphology (small randomly oriented pores channel network, of 3-4 nm pore size) above 80 °C. The relaxometric and magnetothermal features of IO@STMS or IO@WLMS core shell NPs having respectively stellar or worm-like morphologies are compared and discussed to understand the role of the pore structure for MRI and magnetic hyperthermia applications.


Assuntos
Portadores de Fármacos/química , Nanopartículas/química , Dióxido de Silício/química , Concentração de Íons de Hidrogênio , Imageamento por Ressonância Magnética , Nanopartículas/ultraestrutura , Tamanho da Partícula , Porosidade , Temperatura
4.
Int J Obes (Lond) ; 43(11): 2163-2175, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30926950

RESUMO

BACKGROUND/OBJECTIVES: We previously observed that selective agonists of the sympatho-inhibitory I1 imidazoline receptors (LNP ligands) have favorable effects on several cardiovascular and metabolic disorders defining the metabolic syndrome, including body weight. The objectives of this study were to explore the effects of LNPs on adiposity and the mechanisms involved, and to evaluate their impact on metabolic homeostasis. METHODS: Young Zucker fa/fa rats were treated with LNP599 (10 mg/kg/day) for 12 weeks. Effects on body weight, adiposity (regional re-distribution, morphology, and function of adipose tissues), cardiovascular and metabolic homeostasis, and liver function were evaluated. Direct effects on insulin and AMP-activated protein kinase (AMPK) signaling were studied in human hepatoma HepG2 cells. RESULTS: LNP599 treatment limited the age-dependent remodeling and inflammation of subcutaneous, epididymal, and visceral adipose tissues, and prevented total fat deposits and the development of obesity. Body-weight stabilization was not related to reduced food intake but rather to enhanced energy expenditure and thermogenesis. Cardiovascular and metabolic parameters were also improved and were significantly correlated with body weight but not with plasma norepinephrine. Insulin and AMPK signaling were enhanced in hepatic tissues of treated animals, whereas blood markers of hepatic disease and pro-inflammatory cytokine levels were reduced. In cultured HepG2 cells, LNP ligands phosphorylated AMPK and the downstream acetyl-CoA carboxylase and prevented oleic acid-induced intracellular lipid accumulation. They also significantly potentiated insulin-mediated AKT activation and this was independent from AMPK. CONCLUSIONS: Selective I1 imidazoline receptor agonists protect against the development of adiposity and obesity, and the associated cardio-metabolic disorders. Activation of I1 receptors in the liver, leading to stimulation of the cellular energy sensor AMPK and insulin sensitization, and in adipose tissues, leading to improvement of morphology and function, are identified as peripheral mechanisms involved in the beneficial actions of these ligands.


Assuntos
Tecido Adiposo/efeitos dos fármacos , Imidazolinas/farmacologia , Fígado/efeitos dos fármacos , Doenças Metabólicas/prevenção & controle , Obesidade/prevenção & controle , Compostos de Anilina , Animais , Peso Corporal/efeitos dos fármacos , Ingestão de Alimentos/efeitos dos fármacos , Células Hep G2 , Humanos , Masculino , Pirróis , Ratos , Ratos Zucker
5.
Chemistry ; 21(17): 6535-46, 2015 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-25754740

RESUMO

A series composed of a tetra-, a tris- and a bisphosphonated ligand based on a pyridine scaffold (L(4) , L(3) and L(2) , respectively) was studied within the frame of lanthanide (Ln) coordination. The stability constants of the complexes formed with lanthanide cations (Ln=La, Nd, Eu, Gd, Tb, Er and Lu) were determined by potentiometry in aqueous solutions (25.0 °C, 0.1 M NaClO4 ), showing that the tetraphosphonated complexes are among the most stable Ln(III) complexes reported in the literature. The complexation of L(4) was further studied by different titration experiments using mass spectrometry and various spectroscopic techniques including UV/Vis absorption, and steady state and time-resolved luminescence (Ln=Eu and Tb). Titration experiments confirmed the formation of highly stable [LnL(4) ] complexes. (31) P NMR experiments of the LuL(4) complex revealed an intramolecular interconversion process which was studied at different temperatures and was rationalized by DFT modelling. The relaxivity properties of the Gd(III) complexes were studied by recording their (1) H NMRD profiles at various temperatures, by temperature dependent (17) O NMR experiments (GdL(4) ) and by pH dependent relaxivity measurements at 0.47 T (GdL(3) and GdL(2) ). In addition to the high relaxivity values observed for all complexes, the results showed an important second-sphere contribution to relaxivity and pH dependent variations associated with the formation of aggregates for GdL(2) and GdL(3) . Finally, intravenous injection of GdL(4) to a mouse was followed by dynamic MRI imaging at 1.5 T, which showed that the complex can be immediately found in the blood stream and rapidly eliminated through the liver and in large part through the kidneys.


Assuntos
Gadolínio/química , Imageamento por Ressonância Magnética/métodos , Organofosfonatos/química , Animais , Meios de Contraste/química , Gadolínio/sangue , Gadolínio/metabolismo , Rim/metabolismo , Elementos da Série dos Lantanídeos/química , Fígado/metabolismo , Camundongos , Estrutura Molecular , Piridinas/química
6.
Eur Radiol ; 25(2): 505-15, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25249315

RESUMO

OBJECTIVES: Our aim was to conduct a quantitative and qualitative evaluation of high-resolution skull-bone imaging for dentistry and otolaryngology using different architectures of recent X-ray computed tomography systems. MATERIAL AND METHODS: Three multi-slice computed tomography (MSCT) systems and one Cone-beam computed tomography (CBCT) system were used in this study. All apparatuses were tested with installed acquisition modes and proprietary reconstruction software enabling high-resolution bone imaging. Quantitative analyses were performed with small fields of view with the preclinical vmCT phantom, which permits to measure spatial resolution, geometrical accuracy, linearity and homogeneity. Ten operators performed visual qualitative analyses on the vmCT phantom images, and on dry human skull images. RESULTS: Quantitative analysis showed no significant differences between protocols in terms of linearity and geometric accuracy. All MSCT systems present a better homogeneity than the CBCT. Both quantitative and visual analyses demonstrate that CBCT acquisitions are not better than the collimated helical MSCT mode. CONCLUSION: Our results demonstrate that current high-resolution MSCT protocols could exceed the performance of a previous generation CBCT system for spatial resolution and image homogeneity. KEY POINTS: • Quantitative evaluation is a prerequisite for comparison of imaging equipment. • Bone imaging quality could be objectively assessed with a phantom and dry skull. • The current MSCT shows better image quality than a dental CBCT system. • CBCT remains a work-in-progress technology.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Diagnóstico por Imagem/métodos , Maxila/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Base do Crânio/diagnóstico por imagem , Dente/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada Espiral/métodos
7.
Nanomaterials (Basel) ; 13(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36770547

RESUMO

Phosphates in high concentrations are harmful pollutants for the environment, and new and cheap solutions are currently needed for phosphate removal from polluted liquid media. Iron oxide nanoparticles show a promising capacity for removing phosphates from polluted media and can be easily separated from polluted media under an external magnetic field. However, they have to display a high surface area allowing high removal pollutant capacity while preserving their magnetic properties. In that context, the reproducible synthesis of magnetic iron oxide raspberry-shaped nanostructures (RSNs) by a modified polyol solvothermal method has been optimized, and the conditions to dope the latter with cobalt, zinc, and aluminum to improve the phosphate adsorption have been determined. These RSNs consist of oriented aggregates of iron oxide nanocrystals, providing a very high saturation magnetization and a superparamagnetic behavior that favor colloidal stability. Finally, the adsorption of phosphates as a function of pH, time, and phosphate concentration has been studied. The undoped and especially aluminum-doped RSNs were demonstrated to be very effective phosphate adsorbents, and they can be extracted from the media by applying a magnet.

8.
Pediatr Nephrol ; 27(1): 131-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21744055

RESUMO

This study compares different peritoneal dialysis fluids (PDF) in rats over a short contact time. For greater accuracy, net ultrafiltration (UF) and peritoneal transport indices, mass transfer area coefficient (MTAC) were scaled for the in vivo peritoneal surface area recruited (ivPSA) measured by microcomputerized tomography. Wistar rats underwent nephrectomy (5/6ths), were randomized into two groups and given 1.5% glucose PDF, either conventional acidic lactate (n = 14) or pH neutral bicarbonate (BicaVera) (n = 13); MTAC and UF were measured using a 90-min peritoneal equilibrium test (PET), fill volume (IPV) of 10 ml/100 g; small pore fluid transport was determined from sodium balance and used to calculate free water transport (FWT). Each ivPSA value was significantly correlated with the actual IPV, which varied from one rat to another. At 90 min of contact, there was no difference in recruited ivPSA in relation to PDFs. There was a difference (p < 0.01) in net UF/ivPSA 0.45 vs. 1.41 cm(2)/ml for bicarbonate versus lactate, as there was in the proportion of FWT with bicarbonate (42 ± 5% of net UF) compared to lactate (29 ± 4% of net UF). Net UF for individual values of ivPSA differs between conventional PDF and more biocompatible solutions, such as bicarbonate PDF. This observed change in UF cannot be fully explained by differences in glucose transport. The changes in FWT may be explained by the impact of the PDF biocompatibility on aquaporin function.


Assuntos
Bicarbonatos/farmacologia , Materiais Biocompatíveis , Soluções para Diálise/farmacologia , Lactatos/farmacologia , Diálise Peritoneal/métodos , Peritônio/efeitos dos fármacos , Insuficiência Renal/terapia , Água/metabolismo , Animais , Bicarbonatos/metabolismo , Transporte Biológico , Soluções para Diálise/química , Soluções para Diálise/metabolismo , Modelos Animais de Doenças , Concentração de Íons de Hidrogênio , Lactatos/metabolismo , Masculino , Modelos Biológicos , Nefrectomia , Peritônio/diagnóstico por imagem , Peritônio/metabolismo , Ratos , Ratos Wistar , Insuficiência Renal/metabolismo , Fatores de Tempo , Microtomografia por Raio-X
9.
PeerJ ; 9: e12355, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34966570

RESUMO

BACKGROUND: To provide insight into bone turnover, quantitative measurements of bone remodeling are required. Radionuclide studies are widely used in clinical care, but have been rarely used in the exploration of the bone in preclinical studies. We describe a bone planar scintigraphy method for frequent assessment of bone activity in mice across the growing period. Since repeated venous radiotracer injections are hardly feasible in mice, we investigated the subcutaneous route. METHODS: Repeated 99mTc-hydroxymethylene diphosphonate (HMDP) tracer bone planar scintigraphy studies of the knee region and µCT to measure femur growth rate were performed in eight mice between week 6 and week 27 of life, i.e., during their growth period. Three independent investigators assessed the regions of interest (ROI). An index was calculated based on the counts in knees ROI (normalized by pixels and seconds), corrected for the activity administered, the decay between administration and imaging, and individual weights. RESULTS: A total of 93 scintigraphy studies and 85 µCT were performed. Repeated subcutaneous tracer injections were well tolerated and allowed for adequate radionuclide studies. Mean scintigraphic indexes in the knees ROI decreased from 87.4 ± 2.6 × 10-6 counts s-1 pixel-1 MBq-1 g-1 at week 6 to 15.0 ± 3.3 × 10-6 counts s-1 pixel-1 MBq-1 g-1 at week 27. The time constant of the fitted exponential decay was equal to 23.5 days. As control mean femur length assessed by µCT increased from 12.2 ± 0.8 mm at week 6 to 15.8 ± 0.2 mm at week 22. The time constant of the fitted Gompertz law was equal to 26.7 days. A correlation index of -0.97 was found between femur growth and decrease of bone tracer activity count between week 6 and 24. CONCLUSION: This methodological study demonstrates the potential of repeated bone planar scintigraphy in growing mice, with subcutaneous route for tracer administration, for quantitative assessment of bone remodeling.

10.
J Med Imaging Radiat Sci ; 51(1): 173-181, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32057745

RESUMO

INTRODUCTION: This study aims to construct learning curves related to the realization of standardized postprocessing by radiographer students and to discuss their exploitation and interest. MATERIALS AND METHODS: This study was carried out in 21 French students in their 3rd year of training. Two postprocessing protocols in CT (#1 traumatic shoulder; #2 petrous bone) were repeated 15 times by each student. Each achievement was timed to obtain overall learning curves. The realization accuracy was also assessed for each student at each repetition. RESULTS: The learning rates for the two protocols are 63% and 56%, respectively. The number of repetitions to reach the reference time for each protocol is 11 and 12, respectively. In both protocols, the standard deviations are significantly reduced and stabilized during repetitions. The mean accuracy progresses more quickly in protocol #1. DISCUSSION: The measured learning rates reflect a rapid learning process for each protocol. The analysis of the standard deviations shows that students have reached a homogeneous level. The average times and accuracies measured during the last repetitions show that the group has reached a high level of performance. Building learning curves helps students measure their progress and motivates them. CONCLUSION: Obtaining learning curves allows trainers/supervisors to qualify the learning difficulty of a task while motivating students/radiographers. The use of learning curves is inline with the competency-based training paradigm.


Assuntos
Competência Clínica , Curva de Aprendizado , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Tecnologia Radiológica/educação , Tomografia Computadorizada por Raios X , França , Humanos
11.
J Nucl Med ; 49(1): 88-93, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18077535

RESUMO

UNLABELLED: Localization of regions with increased uptake of radiotracer in small-animal SPECT is greatly facilitated when using coregistration with anatomic images of the same animal. As MRI has several advantages compared with CT (soft-tissue contrast and lack of ionizing radiation) we developed a SPECT/low-field MRI hybrid device for small-animal imaging. METHODS: A small-animal single-pinhole gamma-camera (pinhole, 1.5 mm in diameter and 12 cm in focal length) adjacent to a dedicated low-field (0.1 T) small MR imager (imaging volume, 10 x 10 x 6 cm(3)) was used. The animal was placed in a warmed nonmagnetic polymethyl methacrylate imaging cell for MR acquisition, which was followed immediately by SPECT after translation of the imaging cell from one modality to the other. 3-Dimensional T1-weighted sequences were used for MRI. Phantom studies enabled verification of a low attenuation (10%) for (99m)Tc and (201)Tl and a very slight increase in Compton scattering due to the radiofrequency coil and polymethyl methacrylate imaging cell. RESULTS: SPECT/MRI data acquisition and image coregistration of selected examples using different radiotracers for lungs, kidneys, and brain were obtained in 3 nude mice with isotropic spatial resolutions of 0.5 x 0.5 x 0.5 mm(3) for MRI and 1 x 1 x 1 mm(3) for SPECT. The total acquisition time for combined SPECT and MRI lasted 1 h 45 min. CONCLUSION: A low-magnetic-field strength of 0.1 T is a simple and useful solution for a small-animal dual-imaging device combining pinhole SPECT with the adjacent MR imager.


Assuntos
Encéfalo/diagnóstico por imagem , Rim/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Animais , Imageamento por Ressonância Magnética/métodos , Camundongos , Camundongos Nus , Imagens de Fantasmas , Tecnécio , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total/instrumentação , Imagem Corporal Total/métodos
12.
C R Biol ; 331(9): 637-47, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18722982

RESUMO

The feasibility of blood-pool pinhole ECG gated SPECT was investigated in healthy mice to assess right and left ventricular function analysis. Anaesthetized (isoflurane 1-1.5%) adult CD1 mice (n=11) were analyzed after intravenous administration of 0.2 ml of 550 MBq of (99m)Tc human albumin. For blood-pool gated SPECT imaging, 48 ventral step and shoot projections with eight time bins per RR over 180 degrees with 64 x 64 word images were acquired with a small animal gamma camera equipped with a pinhole collimator of 12 cm in focal length and 1.5 mm in diameter. For appropriate segmentation of right and left ventricular volumes, a 4D Fourier analysis was performed after reconstruction and reorientation of blood-pool images with a voxel size of 0.55 x 0.55 x 0.55 mm(3). Average right and left ejection fractions were respectively 52+/-4.7% and 65+/-5.2%. Right end diastolic and end systolic volumes were significantly higher compared with the corresponding left ventricular volumes (P<0.0001 each). A linear correlation between right and left stroke volumes (r=0.9, P<0.0001) was obtained and right and left cardiac outputs were not significantly different 14.2+/-1.9 and 14.1+/-2 ml/min, respectively.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Animais , Débito Cardíaco/fisiologia , Volume Cardíaco/fisiologia , Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Masculino , Camundongos , Valores de Referência , Volume Sistólico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único
13.
J Biomech ; 41(14): 2954-9, 2008 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-18805534

RESUMO

The knowledge of in vivo brain tissue mechanical properties is essential in several biomedical engineering fields, such as injury biomechanics and neurosurgery simulation. Almost all existing available data have been obtained in vitro by invasive experimental protocols. However, the difference between in vivo and post-mortem mechanical properties remains poorly known, essentially due to the lack of a common method that could measure them both in vivo and ex vivo. In this study, we report the use of magnetic resonance elastography (MRE) for the non-invasive assessment of in vivo brain tissue viscoelastic properties and for the investigation of their evolution after the death. Experiments were performed on seven adult male rats. Shear storage and loss moduli were measured in vivo, just after death and at post-mortem time of approximately 24h. A significant increase in shear storage modulus G(') of approximately 100% was found to occur just after death (p=0.002), whereas no significant difference was found between in vivoG(') and G(') at 24h post-mortem time. No significant difference was found between shear loss modulus G('')in vivo and just after death, whereas a decrease of about 50% was found to occur after 24h (p=0.02). These results illustrate the ability of MRE to investigate some of the critical soft tissue biomechanics-related issues, as it can be used as a non-invasive tool for measuring soft tissue viscoelastic properties.


Assuntos
Encéfalo/patologia , Encéfalo/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Mudanças Depois da Morte , Animais , Simulação por Computador , Módulo de Elasticidade , Masculino , Ratos , Ratos Sprague-Dawley , Estresse Mecânico , Viscosidade
14.
Perit Dial Int ; 28(2): 188-94, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18332456

RESUMO

Peritoneal dialysis (PD) uses the dynamic dialysis properties of the peritoneal membrane. The fraction of the anatomic peritoneal surface area (PSA) recruited is of importance for maximizing exchanges and is potentially impacted by parameters such as fill volume. We describe an in vivo assessment of the contact surface area by micro-computed tomography (microCT) using an iodinated contrast medium added to the PD fluid, a contrast agent presumed without surfactant property. In the isotropic volume (reconstructed voxel size 186 microm x 186 microm x 186 microm), the iodinated PD fluid is automatically selected, thanks to its contrast difference with soft tissues, and its surface area is computed. The method was first tested on phantoms showing the ability to select the PD fluid volume and to measure its surface area. In vivo experiments in rat consisted of microCT acquisition of rat abdomen directly after intraperitoneal administration (10 mL/100 g rat body weight) of a dialysis fluid containing 10% by volume iodinated contrast agent. Fluorescein isothiocyanate albumin was used as dilution marker. We found a strong linear relationship (R(2) = 0.98) between recruited PSA (cm(2)) and rat weight (g) in the range of 235 to 435 g: recruited PSA = (1.61 weight + 40.5) cm(2). Applying microCT with a fill volume of 10 mL/100 g rat body weight, the in vivo measured PSA was in the order of magnitude of the ex vivo anatomic PSA as determined by Kuzlan's formula, considered in most instances as the maximal surface area that can be recruited by PD fluid. This new methodology was the first to give an in vivo high-resolution isotropic three-dimensional (3-D) determination of the PSA in contact with dialysate. Its sensitivity allows us to take into account the recruitment of fine 3-D structures of the PSA membrane that were not accessible to previous 2-D-based imaging methodologies. Its in vivo application also integrates the physiological natural tensile stress of tissues.


Assuntos
Peritônio/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Animais , Meios de Contraste , Processamento de Imagem Assistida por Computador , Microrradiografia , Diálise Peritoneal , Imagens de Fantasmas , Ratos , Ratos Wistar , Ácidos Tri-Iodobenzoicos
15.
C R Biol ; 330(11): 821-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17923376

RESUMO

The development of new therapeutic approaches against colorectal cancer requires preclinical studies in mice. In vivo imaging could greatly facilitate these trials, but the small size of the animals is a major limitation for the direct visualization of intestinal tissue. Here we report a method of in vivo imaging of the mouse intestine based on X-ray micro-computed tomography using multiple contrast agents. This method was validated in the model of non-cancerous polyp-like heteroplasia that spontaneously develops in the caecum area of Cdx2+/- mutant mice and in the model of colon adenocarcinoma induced by administration of the chemical carcinogen azoxymethane. As a simple and non-invasive method, multiple-contrast X-ray micro-computed tomography is appropriate for pre-clinical studies of intestinal diseases in living mice.


Assuntos
Colo/anormalidades , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Animais , Fator de Transcrição CDX2 , Desenho de Equipamento , Heterozigoto , Proteínas de Homeodomínio/genética , Enteropatias/diagnóstico por imagem , Masculino , Camundongos , Camundongos Knockout , Fatores de Transcrição/deficiência , Fatores de Transcrição/genética
16.
PLoS One ; 12(8): e0183523, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28817729

RESUMO

Obesity and the metabolic syndrome are two pathologies whose prevalence are in a constant increase. Evaluation of the total fat mass but also of the distribution between visceral and subcutaneous adipose tissue are important factors while assessing the pathophysiology of these two pathologies. Computed tomography (CT) and bioimpedance (BIS) are the translational methods the most frequently used in human beings as well as in rodent models in longitudinal studies on adiposity and obesity. Surprisingly, no direct comparison of micro-CT and BIS was reported yet in mice. Therefore, the present study was carried out to evaluate and compare the accuracy and the uncertainty of measurement of micro-CT and BIS in this species. The proportion of fat mass was measured with BIS, micro-CT and direct post-mortem tissue weight, and correlations between the data were established to evaluate the accuracy of the methods but also the uncertainty of BIS and micro-CT. There were significant correlations between weights of fat tissues on scale and proportion of total fat mass determined by BIS or micro-CT (r = 0.81 and 0.86 respectively) but both methods overestimated the total fat mass, especially in the smallest animals; overestimation of fat mass was amplified with BIS compared to micro-CT. In addition BIS and micro-CT were highly correlated (r = 0.94). Test-test reliability showed a greater variability of the BIS with respect to the micro-CT (coefficient of variation = 17.2 vs 5.6% respectively). Hence, as far as subtle differences between groups or changes within one group are awaited, micro-CT may appear as the most reliable method for determination of fat mass in mice. Micro-CT, unlike BIS, will also allow to qualitatively and quantitatively differentiate between subcutaneous and visceral adipose tissues, which is of major importance in studies on adiposity and its complications.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Análise Espectral/métodos , Microtomografia por Raio-X/métodos , Animais , Autopsia , Composição Corporal , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes
17.
J Nucl Med ; 58(7): 1162-1166, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27980048

RESUMO

Different environmental conditions under anesthesia may lead to unstable homeostatic conditions in rodents and therefore may alter kinetics. In this study, the impact of different heating conditions on PET imaging quantification was evaluated. Methods: Two groups of 6 adult female BALB/c nude mice with subcutaneously implanted tumors underwent microPET imaging after injection of 18F-labeled tetrafluoroborate or 18F-FDG. Dynamic scans were acquired under optimal and suboptimal heating conditions. Time-activity curves were analyzed to calculate uptake and washout time constants. Results: With 18F-labeled tetrafluoroborate, optimal animal heating led to a stable heart rate during acquisition (515 ± 35 [mean ± SD] beats/min), whereas suboptimal heating led to a lower heart rate and a higher SD (470 ± 84 beats/min). Both uptake and washout time constants were faster (P < 0.01) in animals maintained with optimal heating. Conclusion: Although the difference in heart rates was slight, optimal heating yielded significantly faster uptake and washout kinetics than suboptimal heating in all organs for both tracers.


Assuntos
Temperatura Corporal , Ácidos Bóricos/farmacocinética , Fluordesoxiglucose F18/farmacocinética , Frequência Cardíaca , Neoplasias/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Animais , Boratos , Feminino , Calefação , Taxa de Depuração Metabólica , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias/diagnóstico por imagem , Especificidade de Órgãos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
18.
J Med Imaging (Bellingham) ; 4(3): 035503, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28840171

RESUMO

We use high-resolution [Formula: see text] data in multiple experiments to estimate the sources of error during coregistration of images acquired on separate preclinical instruments. In combination with experiments with phantoms, we completed in vivo imaging on mice, aimed at identifying the possible sources of registration errors, caused either by transport of the animal, movement of the animal itself, or methods of coregistration. The same imaging cell was used as a holder for phantoms and animals. For all procedures, rigid coregistration was carried out using a common landmark coregistration system, placed inside the imaging cell. We used the fiducial registration error and the target registration error to analyze the coregistration accuracy. We found that moving an imaging cell between two preclinical devices during a multimodal procedure gives an error of about [Formula: see text] at most. Therefore, it could not be considered a source of coregistration errors. Errors linked to spontaneous movements of the animal increased with time, to nearly 1 mm at most, excepted for body parts that were properly restrained. This work highlights the importance of animal intrinsic movements during a multiacquisition procedure and demonstrates a simple method to identify and quantify the sources of error during coregistration.

19.
Dentomaxillofac Radiol ; 46(1): 20160285, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27580474

RESUMO

OBJECTIVES: Quantitative and qualitative image quality evaluation of two different dental CBCT scanners. METHODS: Two CBCT systems were evaluated in this study: one small field-of-view (FOV) (50-mm diameter) system that also allows two-dimensional (2D) dental panoramic imaging and one large FOV CBCT system (60-180-mm diameter). These devices were all tested with installed acquisition default modes and proprietary reconstruction software, enabling high-resolution bone imaging. Quantitative analyses were carried out to measure spatial resolution, linearity and homogeneity. Small-size phantoms and a human dry skull were used to evaluate intrinsic performances. Visual qualitative analyses of specific anatomical parts were blindly performed by 10 operators. RESULTS: Concerning spatial resolution, small-voxel size protocols provide equivalent results on the two apparatus. In terms of linearity, all systems are highly linear (0.98 < r2 < 0.99) over the range of signal intensities encountered. Our results, coming from either phantoms or the dry skull, demonstrate that the small FOV CBCT suffers from a lack of homogeneity. CONCLUSIONS: For limited oral and maxillofacial volume imaging (diameter < 50 mm), the polyvalent small FOV CBCT (2D and three-dimensional imaging) system used in this study could reach performances similar to those of the large FOV CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Radiografia Dentária/instrumentação , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Crânio/diagnóstico por imagem
20.
IEEE Trans Med Imaging ; 25(2): 158-67, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16468450

RESUMO

We describe the efficient algebraic reconstruction (EAR) method, which applies to cone-beam tomographic reconstruction problems with a circular symmetry. Three independant steps/stages are presented, which use two symmetries and a factorization of the point spread functions (PSFs), each reducing computing times and eventually storage in memory or hard drive. In the case of pinhole single photon emission computed tomography (SPECT), we show how the EAR method can incorporate most of the physical and geometrical effects which change the PSF compared to the Dirac function assumed in analytical methods, thus showing improvements on reconstructed images. We also compare results obtained by the EAR method with a cubic grid implementation of an algebraic method and modeling of the PSF and we show that there is no significant loss of quality, despite the use of a noncubic grid for voxels in the EAR method. Data from a phantom, reconstructed with the EAR method, demonstrate 1.08-mm spatial tomographic resolution despite the use of a 1.5-mm pinhole SPECT device and several applications in rat and mouse imaging are shown. Finally, we discuss the conditions of application of the method when symmetries are broken, by considering the different parameters of the calibration and nonsymmetric physical effects such as attenuation.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Animais , Encéfalo/diagnóstico por imagem , Feminino , Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Camundongos , Análise Numérica Assistida por Computador , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa