1.
J Heart Valve Dis ; 17(1): 81-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18365573

RESUMO

BACKGROUND AND AIM OF THE STUDY: A significant proportion of patients with severe valvular aortic stenosis (AS) and preserved left ventricular (LV) systolic function have low transvalvular gradients. The study aim was to determine the mechanisms and outcome of patients with this hemodynamic profile of AS. METHODS: Among 1,679 patients who underwent transthoracic echocardiography for the evaluation of AS at the authors' institution, 215 (105 females, 110 males; mean age: 77 +/- 10 years) had isolated AS (mean aortic valve area index 0.39 +/- 0.1 cm2/m2), normal sinus rhythm and normal LV ejection fraction. The mean follow up was 23 +/- 12 months, and the end-points were mortality, aortic valve replacement (AVR), or mortality or AVR. RESULTS: Forty-seven patients had a transvalvular mean gradient (MG) <30 mmHg (MG(low)) and 168 had MG > or = 30 mmHg (MG(high)). Compared to MG(high), the MG(low) group had a higher prevalence of hypertension, lower LV end-diastolic volume index (47 +/- 9 versus 56 +/- 12 ml/m2, p <0.0001), lower LV stroke vol-ume index (37 +/- 12 versus 41 +/- 11 ml/beat, p <0.0002), a lesser severity of stenosis (aortic valve area index 0.37 +/- 0.09 versus 0.46 +/- 0.09 cm2/m2, p <0.0001) and a higher systemic vascular resistance (2163 +/- 754 versus 1879 +/- 528 dyne cm s(-5). The LV end-diastolic volume index, systemic vascular resistance and energy loss index were predictors of MG <30 mmHg (OR = 0.30, 95% CI, 0.12, 0.62; OR = 3.05, 95% CI, 1.71, 6.26; and OR = 6.76, 95% CI, 3.44,15.38, respectively). MG <30 mmHg (MGhigh) was associated with almost 50% lower referral to surgery and a two-fold increase in preoperative mortality. CONCLUSION: In severe AS with a normal LV ejection fraction, MG <30 mmHg is related to a lesser severity of stenosis, a smaller LV volume, a lower flow rate and a higher systemic vascular resistance. Compared to the MG(high) group, these patients were less frequently referred to surgery and had a higher mortality.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , New York/epidemiologia , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Taxa de Sobrevida/tendências , Sístole , Fatores de Tempo
2.
J Am Soc Echocardiogr ; 21(9): 990-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18765174

RESUMO

BACKGROUND: The accuracy of left ventricular (LV) volumes and ejection fraction (EF) on two-dimensional echocardiography (2DE) is limited by image position (IP), geometric assumption (GA), and boundary tracing (BT) errors. METHODS: Real-time three-dimensional echocardiography (RT3DE) and cardiac magnetic resonance imaging (CMR) were used to determine the relative contribution of each error source in normal controls (n = 35) and patients with myocardial infarctions (MIs) (n = 34). LV volumes and EFs were calculated using (1) apical biplane disk summation on 2DE (IP + GA + BT errors), (2) biplane disk summation on RT3DE (GA + BT errors), (3) 4-multiplane to 8-multiplane surface approximation on RT3DE (GA + BT errors), (4) voxel-based surface approximation on RT3DE (BT error alone) and (5) CMR. By comparing each method with CMR, the absolute and relative contributions of each error source were determined. RESULTS: IP error predominated in LV volume quantification on 2DE in normal controls, whereas GA error predominated in patients with MIs. Underestimation of volumes on 2DE was overcome by increasing the number of imaging planes on RT3DE. Although 4 equidistant image planes were acceptable, the best results were achieved with voxel-based RT3DE. For EF estimation, IP error predominated in normal controls, whereas BT error predominated in patients with MIs. Nevertheless, one third of the EF estimation error in patients with MIs was due to a combination of IP and GA errors, both of which may be addressed using RT3DE. CONCLUSIONS: The relative contribution of each source of LV quantitation error on 2DE was defined and quantified. Each source of error differed depending on patient characteristics and LV geometry.


Assuntos
Artefatos , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/complicações
3.
J Am Soc Echocardiogr ; 20(5): 445-55, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17484982

RESUMO

BACKGROUND: Assessment of right ventricular function by 2-dimensional echocardiography (2DECHO) is difficult because of its complex shape. Real-time 3-dimensional echocardiography (RT3DECHO) may be superior. METHODS: End-diastolic volume, end-systolic volume, stroke volume, and ejection fraction obtained by 2DECHO, RT3DECHO short-axis disk summation (DS), and RT3DECHO apical rotation were compared with cardiac magnetic resonance imaging in 71 healthy individuals. RESULTS: RT3DECHO DS showed less volume underestimation compared with 2DECHO and RT3DECHO apical rotation. Test-retest variability for RT3DECHO DS end-diastolic volume, end-systolic volume, stroke volume, and ejection fraction were 3.3%, 8.7%, 10%, and 10.3%, respectively. Normal reference ranges of indexed volumes (mean +/- 2SD) for right ventricular end-diastolic volume, end-systolic volume, stroke volume, and ejection fraction were 38.6 to 92.2 mL/m(2), 7.8 to 50.6 mL/m(2), 22.5 to 42.9 mL/m(2), and 38.0% to 65.3%, respectively, for women and 47.0 to 100 mL/m(2), 23.0 to 52.6 mL/m(2), 14.2 to 48.4 mL/m(2), and 29.9% to 58.4%, respectively, for men. CONCLUSIONS: RT3DECHO DS is superior to RT3DECHO apical rotation and 2DECHO for right ventricular quantification, and performs acceptably when compared with cardiac magnetic resonance imaging in healthy individuals.


Assuntos
Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Direita/fisiologia , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sístole , Função Ventricular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa