Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Arch Orthop Trauma Surg ; 144(2): 601-610, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37938379

RESUMO

INTRODUCTION: Surgical treatment options for acromioclavicular joint separations are varied. Frequently, suspension devices (SD) are inserted for stabilization under arthroscopic view. This study investigates the feasibility and accuracy of three-dimensional (3D) digital-volume-tomography (DVT) C-arm navigated implantation with regard to the general trend toward increasingly minimally invasive procedures. MATERIALS AND METHODS: The implantation of a TightRope® suture button system (SD) via a navigated vertical drill channel through the clavicle and coracoid was investigated in 10 synthetic shoulder models with a mobile isocentric C-arm image intensifier setup in the usual parasagittal position. Thereby, in addition the placement of an additive horizontal suture cerclage via a navigated drill channel through the acromion was assessed. RESULTS: All vertical drill channels in the Coracoclavicular (CC) direction could be placed in a line centrally through the clavicle and the coracoid base. The horizontal drill channels in the Acromioclavicular (AC) direction ran strictly in the acromion, without affecting the AC joint or lateral clavicle. All SD could be well inserted and anchored. After tensioning and knotting of the system, the application of the horizontal AC cerclage was easily possible. The image quality was good and all relevant structures could be assessed well. CONCLUSION: Intraoperative 3D DVT imaging of the shoulder joint using a mobile isocentric C-arm in the usual parasagittal position to the patient is possible. Likewise, DVT navigated SD implantation at the AC joint in CC and AC direction on a synthetic shoulder model. By combining both methods, the application in vivo could be possible. Further clinical studies on feasibility and comparison with established methods should be performed.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Humanos , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Radiografia , Clavícula , Acrômio , Extremidade Superior , Luxações Articulares/cirurgia
2.
Arch Orthop Trauma Surg ; 143(8): 4993-5000, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36879154

RESUMO

INTRODUCTION: Proximal humerus fractures are common and often associated with osteoporosis in the elderly. Unfortunately, the complication and revision rate for joint-preserving surgical treatment using locking plate osteosynthesis is still high. Problems include insufficient fracture reduction and implant misplacement. Using conventional intraoperative two dimensional (2D) X-ray imaging control in only two planes, a completely error-free assessment is not possible. MATERIALS AND METHODS: The feasibility of intraoperative three-dimensional (3D) imaging control for locking plate osteosynthesis with screw tip cement augmentation of proximal humerus fractures was retrospectively studied in 14 cases with an isocentric mobile C-arm image intensifier set up parasagittal to the patients. RESULTS: The intraoperative digital volume tomography (DVT) scans were feasible in all cases and showed excellent image quality. One patient showed inadequate fracture reduction in the imaging control, which then could be corrected. In another patient, a protruding head screw was detected, which could be replaced before augmentation. Cement distribution in the humeral head was consistent around the screw tips with no leakage into the joint. CONCLUSION: This study shows that insufficient fracture reduction and implant misplacement can be easily and reliably detected by intraoperative DVT scan with an isocentric mobile C-arm set up in the usual parasagittal position to the patient.


Assuntos
Fraturas do Úmero , Fraturas do Ombro , Humanos , Idoso , Imageamento Tridimensional , Tomografia Computadorizada de Feixe Cônico , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Placas Ósseas , Cimentos Ósseos , Úmero
3.
Arch Orthop Trauma Surg ; 143(11): 6641-6647, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37480380

RESUMO

INTRODUCTION: Fragility fractures (FF) are associated with increased morbidity and mortality and reflect a dramatic turning point in the life of older adults. The scientific discourse is dominated by proximal femoral fractures, but FF affect multiple parts of the body and often precede hip fractures. Orthogeriatric co-management has multiple shown to improve patient's outcome. We hypothesize that all geriatric patients with FF benefit from orthogeriatric co-management. MATERIALS AND METHODS: We retrospectively evaluated all patients over 70 years with FF (hip joint, periprosthetic, spine, pelvic ring, and humerus) of our geriatric trauma center for the years 2019-2021, who received orthogeriatric co-management. Demographic data, fracture type, complications, discharge modality and in-hospital mortality were recorded. For patients transferred to geriatrics, the Barthel Index (BI) and the discharge modality were recorded. Primary outcome parameters were discharge modality and BI difference. Secondary outcome parameters were complication rates and in-hospital mortality. Logistic regression analysis was performed. RESULTS: 555 patients (83.8 ± 6.5 years, 182 males, 373 females) were evaluated. 245 (44.1%) patients were referred to geriatrics for further orthogeriatric treatment. Positive predictors were age, surgery, and a high Charlson Comorbidity Index. The overall in-hospital mortality was 8.6% (n = 48) (5.8% (n = 32) during acute trauma care and 6.5% (n = 16) during stay in geriatrics). The mortality rate of nursing home residents was significantly higher compared to patients living at home (10.4% vs. 5.6%). The rate of non-surgical complications was 44.5%. 26.9% of patients living at home were discharged to a nursing home, while 51.3% were able to return home. The risk of admission to a nursing home was reduced for thoracolumbar fractures (OR = 0.22) and increased markedly for periprosthetic fractures (OR = 3.95). During orthogeriatric treatment, all fractures showed a significant increase in BI. Patients living at home benefited more than nursing home residents (20.5 ± 19.5 vs. 8.7 ± 18.0 points). The chance of a BI increase (> 19 points) was increased for hip and pelvic ring fractures. Devastating results showed patients with dementia. In comparison, mentally healthy patients had a 4.5-fold increased chance of increasing their BI (> 19 points). CONCLUSIONS: Presented data shows that all patients with FF are at high risk for complications and could benefit from standardized orthogeriatric management. Modern patient care requires a holistic orthogeriatric approach to improve patient's outcome.


Assuntos
Fraturas do Quadril , Masculino , Feminino , Humanos , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Fraturas do Quadril/cirurgia , Hospitalização , Centros de Traumatologia
4.
Arch Orthop Trauma Surg ; 143(6): 3155-3161, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35867115

RESUMO

BACKGROUND: Hip fractures in the elderly population are common and the number of patients is rising. For young and geriatric patients with undisplaced fractures osteosynthesis is the primary type of treatment. The dynamic hip screw (DHS) is around for many years and proved its value especially in displaced fractures. Since 2018 the femoral neck system (FNS) is available as an alternative showing promising biomechanical results. The aim of this study is to evaluate clinical results of the FNS and compare it to the DHS. MATERIALS AND METHODS: Patients older than 18 years with Garden I-IV fractures that were treated with osteosynthesis in a level 1 trauma center were included in the study. Between January 2015 and March 2021, all patients treated with FNS (1-hole plate, DePuy-Synthes, Zuchwil, Switzerland) or DHS (2-hole plate, DePuy-Synthes, Zuchwil, Switzerland) for proximal femur fractures were included in the study. Closed reduction was achieved using a traction table. All operations were carried out by experienced orthopedic trauma surgeons. Primary outcome measures were rate of implant failure (cut out) and surgical complications (hematoma, infection). Secondary outcome measures were Hb-difference, length of hospital stay and mortality. RESULTS: Overall, 221 patients were included in the study. 113 were treated with FNS, 108 with DHS. Mean age was 69 ± 14 years. There were 17.2% Garden I, 47.5% Garden II, 26.7% Garden III and 8.6% Garden IV fractures. No difference between the groups for age, body mass index (BMI), Charlson comorbidity index (CCI), time to surgery, Pauwels and Garden classification, rate of optimal blade position or tip apex distance was found. FNS showed lower pre- to postoperative Hb-difference (1.4 ± 1.1 g/l vs. 2.1 ± 1.4 g/l; p < 0.05), shorter operating time (36.3 ± 11.6 min vs. 54.7 ± 17.4 min; p < 0.05) and hospital stay (8.8 ± 4.3 d vs. 11.2 ± 6.8 d; p < 0.05). Surgical complications (FNS 13.3% vs. DHS 18.4%, p > 0.05), rate of cut out (FNS 12.4% vs. DHS 10.2%, p > 0.05) and mortality (FNS 3.5%; DHS 0.9%; p > 0.05) showed no difference between the groups. Logistic regression showed that poor blade position was the only significant predictor for cut out and increased the risk by factor 7. Implant related infection (n = 3) and hematoma/seroma (n = 6) that needed revision was only seen in DHS group. CONCLUSION: FNS proved to be as reliable as DHS in all patients with hip fractures. Not the type of implant but blade positioning is still key to prevent implant failure. Still due to minimal invasive approach implant related infections and postoperative hematomas might have been prevented using the FNS.


Assuntos
Fraturas do Colo Femoral , Colo do Fêmur , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/etiologia , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Fraturas do Quadril/etiologia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
5.
Arch Orthop Trauma Surg ; 142(1): 77-81, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32880704

RESUMO

INTRODUCTION: After surgical treatment of injuries of the lower extremity, partial weight bearing is often suggested until soft tissue consolidation. It is doubtful, if this recommendation can be implemented, even in the case that a patient is performing partial weight bearing with a physical therapist. Consequently the question remains, if patients are able to implement partial weight bearing after surgery and which factors favor incompliance. MATERIALS AND METHODS: 49 patients, who underwent surgical treatment after injuries of the lower extremity, were equipped with electronic shoe insoles on both sides. Different weight bearing instructions were given depending on the type of injury and surgery (full weight bearing vs. 20 kg weight bearing vs. non-weight bearing). Besides loading, other factors like age, gender, weight and physical activity were evaluated. Statistical analysis was performed using Chi-square and Fisher's exact test with significance set at a p value < 0.05. RESULTS: 25 of the 40 patients, who had to perform non- or partial weight bearing, were not able to follow postoperative instructions (compliance rate 37.5%). The average loading of the whole collective was 32.6 kg (4.8-109.2 kg). The specification of loading had no statistically significant influence on real loading (p-value 0.39). Elderly patients were less able to follow instructions than younger patients (36 vs 30.2 kg). Physically active compared to non-active patients overloaded their injured extremity (37.8 vs 28.7 kg). Patients with a high body mass index (BMI) encountered more difficulties to perform partial weight bearing than lightweight patients (36.9 vs 25.1 kg). CONCLUSIONS: Most patients were not able to follow loading limitation, even a few days after surgery and even if the patients were trained by a physiotherapist. Excessive weight bearing-related complications should be evaluated.


Assuntos
Extremidade Inferior , Cooperação do Paciente , Idoso , Humanos , Extremidade Inferior/cirurgia , Período Pós-Operatório , Suporte de Carga
6.
Acta Radiol ; 61(6): 768-775, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31569948

RESUMO

BACKGROUND: Iterative reconstruction is well established for CT. Plain radiography also takes advantage of iterative algorithms to reduce scatter radiation and improve image quality. First applications have been described for bedside chest X-ray. A recent experimental approach also provided proof of principle for skeletal imaging. PURPOSE: To examine clinical applicability of iterative scatter correction for skeletal imaging in the trauma setting. MATERIAL AND METHODS: In this retrospective single-center study, 209 grid-less radiographs were routinely acquired in the trauma room for 12 months, with imaging of the chest (n = 31), knee (n = 111), pelvis (n = 14), shoulder (n = 24), and other regions close to the trunk (n = 29). Radiographs were postprocessed with iterative scatter correction, doubling the number of images. The radiographs were then independently evaluated by three radiologists and three surgeons. A five-step rating scale and visual grading characteristics analysis were used. The area under the VGC curve (AUCVGC) quantified differences in image quality. RESULTS: Images with iterative scatter correction were generally rated significantly better (AUCVGC = 0.59, P < 0.01). This included both radiologists (AUCVGC = 0.61, P < 0.01) and surgeons (AUCVGC = 0.56, P < 0.01). The image-improving effect was significant for all body regions; in detail: chest (AUCVGC = 0.64, P < 0.01), knee (AUCVGC = 0.61, P < 0.01), pelvis (AUCVGC = 0.60, P = 0.01), shoulder (AUCVGC = 0.59, P = 0.02), and others close to the trunk (AUCVGC = 0.59, P < 0.01). CONCLUSION: Iterative scatter correction improves the image quality of grid-less skeletal radiography in the clinical setting for a wide range of body regions. Therefore, iterative scatter correction may be the future method of choice for free exposure imaging when an anti-scatter grid is omitted due to high risk of tube-detector misalignment.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/lesões , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Espalhamento de Radiação , Adulto Jovem
7.
J Clin Med ; 13(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38610658

RESUMO

Background: This study investigates the surgical state-of-the-art procedure for humeral shaft fractures with primary radial nerve palsy based on its own case series in relation to the current and established literature. Methods: Retrospective review of treated cases between January 2018 and December 2022 describing radial nerve palsy after humerus shaft fractures, radiological fracture classification, intraoperative findings, surgical procedure, patient follow-up and functional outcome. Results: A total of 804 patients (463 women and 341 men) with humerus shaft fractures were identified. A total of 33 patients showed symptomatic lesions of the radial nerve (4.1%). The primary lesion was identified in 17 patients (2.1%). A broad and inhomogeneous distribution of fractures according to the AO classification was found. According to the operative reports, the distraction of the radial nerve was found eleven times, bony interposed three times and soft tissue constricted/compressed three times. In every case the radial nerve was surgically explored, there was no case of complete traumatic nerve transection. Four intramedullary nails and thirteen locking plates were used for osteosynthesis. Complete recovery of nerve function was seen in 12 cases within 1 to 36 months. Three patients still showed mild hypesthesia in the thumb area after 18 months. Two patients were lost during follow-up. Conclusions: With this study, we support the strategy of early nerve exploration and plate osteosynthesis in humeral fractures with primary radial nerve palsy when there is a clear indication for surgical fracture stabilisation. In addition, early exploration appears sensible in the case of palsies in open fractures and secondary palsy following surgery without nerve exposure as well as in the case of diagnostically recognisable nerve damage. Late nerve exploration is recommended if there are no definite signs of recovery after 6 months. An initial wait-and-see strategy with clinical observation seems reasonable for primary radial nerve palsies without indication for surgical fracture stabilisation.

8.
J Surg Educ ; 81(11): 1683-1690, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39293193

RESUMO

BACKGROUND: The study is intended to show that the operative quality of a resident in orthopedic trauma surgery is comparable to that of a senior physician in the most common orthopaedic trauma surgeries (Plate osteosynthesis in ankle fractures and distal radius fractures, ESIN in pediatric forearm fractures, implantation of a proximal femoral nail in pertrochanteric femur fractures and hemiarthroplasty in femoral neck fractures) with appropriate supervision by a senior physician. With only minimal deviations in the operating time, which is becoming increasingly relevant in everyday clinical practice, surgical training of residents could be supported. MATERIAL AND METHODS: 200 patients of the above-mentioned fracture patterns each, who were treated surgically between January 1, 2016 and December 31, 2020, were detected and categorized. In particular, a qualitative characteristic was determined for each fracture on the basis of the standard pre and postoperative X-rays taken during surgery and statistically evaluated with the surgery time, the fracture classification and the training status of the anonymized surgeon. Anonymized x-rays were evaluated by 2 senior physicians and 2 residents. RESULTS: Operations were performed by residents in 33.5 % of the cases (ankle fractures 42.0%; distal radius fractures 30.5%; pediatric forearm fractures 30.5%; pertrochanteric femur fractures 50.5%; femoral neck fractures 14.0%). Surgical complication rate was 4.8% in the resident group and 9.0% in the attending surgeon group. Revision surgeries were performed in 2.1% of resident cases, and in 4.1% of attending surgeon cases. In the resident group, time of surgery was 7.4 min longer for ankle fractures, 4.4 min for distal radius fractures, 2.8 min for forearm fractures, 2.3 min longer in proximal femur fractures 8.2 min longer for femoral neck fractures. No statistically significant difference in radiological outcome was observed in any of the groups after evaluation of the x-rays. CONCLUSION: This study shows that only slightly more than one third of all mentioned operations are performed by residents, although there is no statistical difference in quality. The operating time is extended on average by only 5 minutes. The surgical complication rate as well as the revision rate is higher in the group of senior physicians, whereby the more complicated fractures were treated by them. Resident involvement in trauma surgery is therefore not associated with increased morbidity or mortality of patients.


Assuntos
Internato e Residência , Humanos , Competência Clínica , Procedimentos Ortopédicos/educação , Masculino , Feminino , Fraturas Ósseas/cirurgia , Duração da Cirurgia , Estudos Retrospectivos
9.
Injury ; 55(12): 111924, 2024 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-39395386

RESUMO

INTRODUCTION: Hip fractures are still associated with high morbidity and mortality. Despite international guidelines advocating for urgent surgical treatment, delays often occur, particularly for patients on long-term antithrombotic therapy. We hypothesised that urgent surgical care for the anticoagulated hip fracture patient is not associated with severe bleeding complications. MATERIAL AND METHODS: For the period from 2015 to 2021, we retrospectively reviewed clinical records of 1142 patients with proximal femur fractures treated within 24 h of admission to our trauma centre (mean age 80.4 ± 12.4 years; 761 females, 381 males). The cohort comprised 409 femoral neck and 733 trochanteric fractures, managed with either arthroplasty (n = 297), hip-preserving techniques (n = 147), or intramedullary nailing (n = 698). Of these, 583 patients (51.1 %) were on long-term antithrombotic therapy. The primary endpoints included transfusion rate and the difference in haemoglobin (Hb) levels from pre- to postoperative. Secondary endpoints were in-patient mortality and occurrence of postoperative haematomas requiring surgical revision. A regression analysis was performed. RESULTS: The mean time to surgery was 10.3 h, with delays observed in patients on direct oral anticoagulants (DOACs). Overall, 25.9 % (n = 296) of the patients required blood transfusions. The transfusion rate was dependent on duration of the surgery, preoperative Hb level, and anticoagulation with DOACs. Similarly, the Hb difference was found to be dependent on the duration of surgery, preoperative Hb level, and anticoagulation with DOACs. In-patient mortality was 5.3 % (n = 60). Regression analysis indicated that mortality was dependent on a high ASA classification of 4 and the time to surgery, but not on the type of antithrombotic therapy. 3.1 % of the patients needed surgical revision due to postoperative haematoma with prolonged duration of surgery and antithrombotic therapy (PAI [OR = 3.7, 95 % CI: 1.1-12.7], DOACs [OR = 3.4, 95 % CI: 1.3-8.8], and VKA [OR = 5.5, 95 % CI: 1.8-17.1], p < 0.05) as independent risk factors. CONCLUSION: As postoperative haematoma and the need for transfusion are manageable situations, we conclude that immediate surgical treatment of hip fracture patients on long-term antithrombotic therapy within 24 h is feasible and patients may benefit.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38995404

RESUMO

PURPOSE: The surgical treatment of acute traumatic AC joint dislocations is still a subject of scientific debate in the literature. The arthroscopically assisted stabilization procedure with a suture button system has been successfully established and is widely used in daily practice. It is minimally invasive and allows the anatomical reconstruction of the torn coracoclavicular ligaments in one step with a permanent implant that does not have to be removed in a second operation. This clinical pilot study is the first to describe the new method of navigated suture button implantation with the future aim of further reducing surgical invasiveness and further increasing surgical precision. MATERIALS AND METHODS: 10 patients with a Rockwood 3b/5 injury could be included in the prospective study (DRKS00031855) within 5 months according to inclusion and exclusion criteria. Surgical stabilization was performed with a suture button system via a navigated coracoclavicular drill tunnel. Demographic and radiological data as well as information on health and shoulder function were collected from patient records, X-rays, DVT scan and 3 questionnaires (DASH, NHS and Eq. 5D) at the preoperative, intraoperative and postoperative (discharge, 6 weeks and 3 months) time points. RESULTS: All operations could be performed within 8.8 days (± 6.81) after trauma. The average operation time was 50.3 min (± 8.81). The mean distance of the drill hole in the clavicle to the AC joint was 26.6 mm (± 2.63). The radiologically measured vertical coracoclavicular distance was 38.8 mm (± 6.16) at discharge and 41.11 mm (± 7.51) at 3 months. This loss of reduction was not statistically significant. In contrast, the DASH, NHS and Eq. 5D results showed significant improvement from discharge to 3 months postoperatively. CONCLUSION: Image-guided 3D C-arm navigated AC joint suture button stabilization is feasible in everyday surgical practice. It may be possible to achieve a further reduction in invasiveness while at the same time increasing the accuracy of implant positioning. Further clinical studies with a larger number of patients and a longer follow-up period are necessary to enable a comparison with conventional methods.

11.
Z Orthop Unfall ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977006

RESUMO

Since 2019, a surgery supporting system (SPM, surgical process manager; Johnson & Johnson, New Brunswick, New Jersey, Vereinigte Staaten) has been used in a Level I trauma center for common trauma surgery procedures (distal radius fractures, proximal femur fractures, ankle fractures, proximal humerus fractures, and spine fractures). The hypothesis of this study was that implementing standardized procedures (by using SPM) may reduce radiation exposure, especially for unexperienced surgeons.Workflows were developed for different surgical procedures (distal radius fractures, proximal femur fractures, ankle fractures, proximal humerus fractures, and spine fractures) and added into the SPM. Between October 2019 and June 2022, 90 surgeries using the SPM were included in the study. A control group was included with 107 surgeries using the same surgical technique. The values measured were the radiation exposure during the surgical procedure, the experience of the head surgeon, and whether or not the SPM was used. A statistical analysis was performed by using the chi square and Fischer exact tests, with significance set at a p value < 0.05.SPM was applicated in 51 cases for the distal radius (control group 54 patients), 20 cases for distal fibula fractures (control group 21 patients), 9 cases for the proximal femur (control group 19 patients), 5 cases for vertebral fractures (control group 7 patients), and 5 cases for the proximal humerus (control group 6 patients). No difference concerning the median radiation exposure was observed by plating distal radius fractures with 5.7 Gy/cm² in the SPM group and a median radiation exposure of 6.4 Gy/cm² in the control group (p = 0.96). The distal fibula fractures showed no significant difference in the intraoperative radiation (17.4 Gy/cm² vs. 6.4 Gy/cm², p value 0.53). Radiation exposure was lower when a consultant performed surgery without showing any significance, independent if SPM was used or not.In this study, no significant difference in the intraoperative radiation dose was observed when using a surgery supporting computer system. The experience of the surgeon showed no influence as well, regardless if SPM was used or not. Additional data should be collected questioning these findings.

12.
Cureus ; 15(3): e35781, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37025721

RESUMO

Background In the modern Western world, activities and the daily routine of children have changed over time. Detailed analyses of the mechanisms of injuries and current fracture patterns in children are rare. The aim of the study was to elicit and investigate the most dangerous leisure and sporting activities leading to fractures in children today. Materials and methods This is a retrospective study focusing on children that were treated in a level-one trauma center in Germany between 2015 and 2020. All children who were 14 years of age or younger and suffered a traumatic injury treated in our emergency department were included in this study. From the database, mechanisms of injury, type of injury, age, and gender were analyzed. Results The study included 12508 patients, including 7302 males and 5206 females. Among the 10 most common mechanisms of injury were collisions (8.6%), falls (7.7%), injuries while playing (6.1%) or while running or walking (5.9%), soccer (5.9%), bicycle accidents (3.8%), and trampoline falls (3.4%). Road traffic accidents involving passengers or pedestrians caused 3.3% of the injuries but were the most common cause of death. The most common mechanisms of injury causing a fracture were falls, playing soccer, and bicycle accidents. Sorting the mechanisms of injury by the percentage that caused a fracture, the most dangerous activities were falling from heights above 2 meters, skiing and snowboarding, climbing and bouldering, skateboarding, and horseback riding. In the five-year study period, four out of six children died due to road traffic accidents. Conclusion Injured children must be provided with the best quality of care 24/7 in orthopedic trauma departments and have to be kept as a focus in the training of orthopedic trauma surgeons. Road traffic accidents are still the main cause of death in children, but they are overall less common. Falls and sports activities are the most likely to cause a fracture.

13.
Eur J Trauma Emerg Surg ; 49(1): 451-459, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36001123

RESUMO

BACKGROUND: Pediatric traumas are common and remain a unique challenge for trauma surgeons. Demographic data provide a crucial source of information to better understand mechanisms and patterns of injury. The aim of this study was to provide this information to improve treatment strategies of potentially preventable morbidity and mortality in children. MATERIAL AND METHODS: A retrospective review of every pediatric trauma treated in the emergency department (ED) between 2015 and 2019 was performed. Inclusion criteria were the age between 0 and 14 years and admission to the ED after trauma. Demographic data, time of presentation, mechanism of injury and pattern of injury, treatment, and outcome were analyzed. Different injury patterns were assessed in relation to age group, sex, mechanism of injury and treatment. RESULTS: A total of 12,508 patients were included in this study. All patients were stratified into five age groups: babies under the age of 1 (8.8%), toddlers between 1 and 3 (16.8%), preschool children between 4 and 6 (19.3%), young school children between 7 and 10 (27.1%), and young adolescents between 11 and 14 (27.9%). The predominant sex in all age groups was male. 47.7% of patients were admitted between 4 and 10 pm; 14.8% of the patients arrived between 10 pm and 8 am. Peak months of admissions were May to July. Overall, 2703 fractures, 2924 lacerations and superficial tissue injury, 5151 bruises, 320 joint dislocations, 1284 distortions, 76 burns, and 50 other injuries were treated. Most common mechanisms for fractures were leisure activities, falls, and sports-related activities. Forearm fractures were the most common fractures (39.5%) followed by humerus fractures (14%) and fractures of the hand (12.5%). A total of 700 patients with fractures (25.9%) needed surgery. 8.8% of all patients were hospitalized for at least one day. 4 patients died in the hospital (0.03%). CONCLUSION: Despite of higher risk, severe injuries in children are rare. Minor injuries and single fractures are common. Treatment should be managed in specialized centers to ensure an interdisciplinary care and fast recovery. Peak times in the late afternoon and evening and summer months should be taken into consideration of personnel planning.


Assuntos
Fraturas Ósseas , Luxações Articulares , Lactente , Pré-Escolar , Adolescente , Criança , Humanos , Masculino , Recém-Nascido , Fraturas Ósseas/epidemiologia , Serviço Hospitalar de Emergência , Estudos Retrospectivos , Hospitalização
14.
J Clin Med ; 12(4)2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36836197

RESUMO

BACKGROUND: Proximal femoral fractures occur with increasing incidence, especially in the elderly. Commonly used implants for surgical treatment are cephalomedullary nails. To increase stability, a perforated femoral neck blade can be augmented with cement. The study investigated whether this results in a relevant clinical advantage and justifies the higher cost. MATERIALS AND METHODS: This is a single-center retrospective study of 620 patients with proximal femur fractures treated with cephalomedullary nailing. Between January 2016 and December 2020, 207 male and 413 female patients were surgically treated with a proximal femur nail (DePuy Synthes) using a perforated blade and cement augmentation in cases with severe osteoporosis. Primary outcome measures were the rate of cut-out, tip apex distance and the positioning of the blade in the femoral head. Secondary outcome measures were the implant costs and operating times. RESULTS: Of the 620 femoral neck blades, 299 were augmented with cement. A total of six cut-outs were seen in the first 3 months after the operation. There were three in the cement-augmented group (CAB = cement-augmented blade) and three in the conventional group (NCAB = non-cement-augmented blade). There was a significant positive correlation between age and augmentation, with a mean difference of 11 years between the two groups (CAB 85.7 ± 7.9 vs. NCAB 75.3 ± 15.1; p < 0.05). There was no difference in the tip-apex distance (CAB 15.97 vs. 15.69; p = 0.64) or rate of optimal blade positions between the groups (CAB 81.6% vs. NCAB 83.2%; p = 0.341). Operation times were significantly longer in the cemented group (CAB 62.6 21.2 min vs. NCAB 54.1 7.7 min; p < 0.05), and the implant cost nearly doubled due to augmentation. CONCLUSION: When the principles of anatomic fracture reduction, optimal tip-apex distance and optimal blade position are combined with cement augmentation in cases of severe osteoporosis, a cut-out rate of less than 1% can be achieved. Nevertheless, it should be noted that augmentation remains expensive and prolongs surgery time without definite proof of mechanical superiority.

15.
Surg Open Sci ; 16: 228-234, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38076570

RESUMO

Purpose: Since October 2019 a computer software named SPM (surgical process manager) is used in a Level I Trauma center. Workflows were developed for distinct surgical procedures (distal radius fractures, proximal femur fractures, ankle fractures, proximal humerus fractures and vertebral fractures). In addition, these workflows were separated in a shortened "Expert"-versions for consultants and a more detailed "Learner"- versions for residents.This investigation was intended to show, if and what kind of benefits in regard to efficiency (incision to suture and suture to incision time), education and complications a surgery supporting software can bring. Methods: SPM was used in 90 cases during October 2019 to June 2022. A control trial with 108 patients was developed, including patients of the same age, having same kind of injuries, receiving the same surgery technique without using the SPM.The software was installed on the computer in the operation room, projected on head monitors and operated by a foot pedal. Complications could also be documented using the pedal.Groups were divided in surgical procedures and fracture type, qualification of the surgeon, complications and surgery time. Surgery times were taken from the hospital computer system (SAP IS-H). A statistical analysis was performed by using the chi square and Fischer exact test with significance set at a P value <0.05. Results: In 51 cases the software was used for the distal radius (control group 54 patients), in 20 cases for Weber fractures (control group 21 patients), in 9 cases for the proximal femur (control group 19 patients), in 5 cases for vertebral fractures (control group 7 patients) and in 5 cases for the proximal humerus (control group 6 patients).Time from incision to closure was significant higher in the intervention group (49 vs 42 min, p- value 0,018) and wasn't significant lower in the "expert" group, fixing radius and ancle fractures (39 to 46 min, p value 0,186).Comparing the SPM and control group concerning closing to incision time, no difference could be observed (56 to 58,5 min, p value 0,828).The greatest time deviation between "Learners"und "Experts"was observed in reduction and fixation (p value 0,006) in ankle fractures. The "Expert"group also needed less time for the approach (p value 0,008) in case of distal radius fractures.Unexpected events were more often observed in the intervention group (5,5 vs 3,7 %). Conclusions: A surgery supporting computer system might be a good tool for detecting and optimizing workflows in the operation room and for improving and analyzing the training of residents and surgical assistants.In addition, it offers the opportunity to document intraoperative complications. However, a saving of time wasn't observed in this study. Further investigations with bigger number of cases and a longer follow-up are necessary to proof these findings statistically.

16.
Eur J Trauma Emerg Surg ; 49(6): 2553-2560, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37535095

RESUMO

INTRODUCTION: Pelvic fractures were often associated with high-energy trauma in young patients, but data show a significant increase in osteoporotic pelvic fractures in old age due to the progressive demographic change. There is an ongoing discussion about the best fixation techniques, which are ranging from lumbopelvic fixation to sacral bars or long transiliac-transsacral (TITS) screws. This study analyzes TITS screw osteosynthesis and sacroiliac screw osteosynthesis (SI), according to biomechanical criteria of fracture stability in osteoporotic human pelvic cadavers ex vivo. METHODS: Ten osteoporotic cadaveric pelvises were randomized into two groups of 5 pelvises each. An FFP-IIc fracture was initially placed unilaterally and subsequently surgically treated with a navigated SI screw or a TITS screw. The fractured side was loaded in a one-leg stance test setup until failure. Interfragmentary movements were assessed by means of optical motion tracking. RESULTS: No significant difference in axial stiffness were found between the SI and the TITS screws (21.2 ± 4.9 N and 18.4 ± 4.1 N, p = 0.662). However, there was a significantly higher stability of the fracture treatment in the cohort with TITS-screws for gap angle, flexion, vertical movement and overall stability. The most significant difference in the cycle interval was between 6.000 and 10.000 for the gap angle (1.62 ± 0.25° versus 4.60 ± 0.65°, p = 0.0001), for flexion (4.15 ± 0.39 mm versus 7.60 ± 0.81 mm, p = 0.0016), interval 11.000-15.000 for vertical shear movement (7.34 ± 0.51 mm versus 13.99 ± 0.97 mm, p < 0.0001) and total displacement (8.28 ± 0.66 mm versus 15.53 ± 1.07 mm, p < 0.0001) for the TITS and the SI screws. CONCLUSIONS: The results of this biomechanical study suggest a clear trend towards greater fracture stability of the TITS screw with significantly reduced interfragmentary movement. The application of a TITS screw for the treatment of the osteoporotic pelvic ring fracture may be prioritized to ensure the best possible patient care.


Assuntos
Fraturas Ósseas , Fraturas por Osteoporose , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas por Osteoporose/cirurgia , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Pelve , Sacro/cirurgia , Sacro/lesões
17.
Z Orthop Unfall ; 161(5): 526-531, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35235972

RESUMO

PURPOSE: In order to prevent implant failure and secondary fracture dislocation, it is often recommended that patients perform partial weight-bearing after surgery of the lower extremity. Previous examinations showed that patients are often not able to follow these instructions. In this study, patients who had undergone surgery of the lower extremity were studied in order to analyze whether incorrect loading influenced the number and severity of complications. METHODS: Fifty-one patients were equipped with electronic shoe insoles, which measure loading and other parameters. The measurement period was 24 to 102 hours. Median duration of follow-up was 490 days. The primary outcome parameter was postoperative complications leading to revision surgery. Statistical analysis was performed using the chi-square and Fisher exact tests with significance set at a p < 0.05. RESULTS: Seven out of fifty-one patients had postoperative complications. Four wound complications, one implant failure, chronic instability after fracture of the tibia, and one implant loosening of a hip prosthesis were recorded. In total, 26 of 39 patients were not able to follow the postoperative instructions. Five of the twenty-six patients with difficulties in partial weight-bearing suffered a postoperative complication. In comparison, only 2 of the other 25 patients were affected. There was no statistically significant correlation between high weight-bearing and occurrence of complications (p = 0.29). CONCLUSION: Most of the patients were unable to follow the surgeon's instructions for partial weight-bearing. Excessive loading did not seem to influence the number and severity of postoperative complications, especially regarding implant failure. Therefore, we should continue with measurements and reevaluate the "partial weight-bearing doctrine".


Assuntos
Prótese de Quadril , Falha de Prótese , Humanos , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Extremidade Inferior , Suporte de Carga , Reoperação , Resultado do Tratamento
18.
Cureus ; 14(10): e29986, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36381761

RESUMO

Background Since March 2020, increasing numbers of hospitalized patients with coronavirus disease-2019 (COVID-19) infections have been registered. The first and the second waves necessitated the extensive restructuring of hospital infrastructure with prioritization of intensive care capacity. Elective surgeries in all surgical disciplines were postponed to preserve intensive care capacity for COVID-19 patients. However, emergency care for trauma patients had to be maintained. Especially, geriatric patients with hip fractures often require intensive care. This study sought to investigate the possible excess mortality of geriatric patients with femoral neck fractures due to shorter intensive care unit stays because of COVID-19. Material and methods All patients over the age of 70 between March 2019 and February 2020 who underwent surgical treatment for femoral neck fractures were included. This cohort (group 1) was compared with all patients over 70 who received surgical treatment for hip fractures during the period of the pandemic between March 2020 and February 2021 with attention to potential excess mortality due to low intensive care capacity (group 2). Demographic data, American Society of Anesthesiologists (ASA) score, surgical modality, ICU stay, complications, and mortality were analyzed and compared. Results A total of 356 patients with 178 in each cohort with a mean age of 82.7 in group 1 and 84.8 in group 2 (p<0.05) were included. No significant difference was seen in sex and ASA scores. During the pandemic, patients with hip fractures had a significantly shorter stay in ICU (0.4 ± 0.9 vs 1.2 ± 2.8 days; p<0.05), shorter time to surgery (29.9 ± 8.2 vs 16.8 ± 5.3 h; p<0.05) and operations were significantly more often performed out-of-hour (4 pm-12 am 47.8% vs 56.7%; 12 am-8 am 7.9% vs 13.5%, p<0.05). Interestingly, mortality was lower during the pandemic, but the difference did not reach significance (6.7% vs 12.4%, p=0.102). Conclusion During the pandemic, ICU capacity was reserved for COVID patients. Due to a change in the law of the Joint Federal Committee with effect from January 1, 2021, all patients with proximal femur fractures had to be operated on within the first 24 hours, which is why a significantly shorter time to surgery was observed during the pandemic period. As a consequence, a lower mortality rate was observed, although no significance could be reached.

19.
Eur J Trauma Emerg Surg ; 48(5): 3401-3407, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35394142

RESUMO

BACKGROUND: Pediatric femur fractures are a major trauma in children. Different treatment algorithms have been developed but indications for surgical treatment, especially in very young patients, are still controversial. Literature recommends surgical stabilization with elastic-stable intramedullary nailing (ESIN) starting at the age of 3 and non-operative treatment in younger patients. This study sought to present the outcome of patients younger than 3 years of age treated with ESIN for femur fractures. MATERIALS AND METHODS: Inclusion criteria were patients younger than 3 treated with ESIN in femur fractures. Patient demographics, fracture characteristics, mechanism of injury, outcomes and complications were recorded using charts and X-rays. Primary outcome measures were time to mobility, fracture consolidation and surgical-related complications. RESULTS: Between 2010 and 2020, 159 patients were treated with ESIN in femur fractures in our institution. A total of 30 patients met the criteria. The mean age was 2.1 ± 0.7 years (13 months-2.9 years). Most common mechanism was fall from standing height (60%). Other mechanisms were motor vehicle accidents as a pedestrian (10%) or as a passenger (10%) as well as direct blow trauma (20%). Femoral shaft fracture was the most common injury (80%). 5 subtrochanteric and one distal metaphyseal femur fractures were found. Mean length of stay was 2.0 ± 1.3 days. Radiographic controls were performed on day 1, 14 and 6 weeks after surgery if not otherwise specified or if complications occurred. 4.6 ± 1.2 (n 2-7) X-rays were performed on average after surgery. First radiographic consolidation signs were seen after 2.4 ± 0.6 weeks. Only one child showed surgical-related complication with a leg length discrepancy of 1 cm. In 10% of the patients, shortening after surgery of 1.7 ± 1.4 mm (0.3-3.1 mm) occurred. One child initially treated with traction therapy showed skin irritations and was operated with ESIN. No non-union or ESIN-related complications were found. Mean follow-up was 5.1 ± 4.4 months (4-24 months). First independent mobilization was seen at an average of 3.4 ± 1.1 weeks (2-6 weeks) after surgery. Implant removal was performed after 3.2 ± 1.3 months (2-8 months). No refracture after implant removal occurred. CONCLUSION: Early results with ESIN show a reasonable and safe treatment option for femur fractures in toddlers and young children under the age of 3 with easy postoperative care, fast fracture union and early independent mobilization.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Pinos Ortopédicos , Criança , Pré-Escolar , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Humanos , Lactente , Estudos Retrospectivos , Resultado do Tratamento
20.
Unfallchirurgie (Heidelb) ; 125(11): 872-879, 2022 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-34591137

RESUMO

BACKGROUND AND OBJECTIVE: The isolated proximal radius fracture in children is a quite rare injury. In difference to adults a conservative treatment is often possible. But in case of increasing dislocation the indication for surgery is given. Options for an operative treatment are "closed reduction", "percutaneous reduction", "intramedullary nailing", "open reduction" with and without fixation. Aim of this study is to compare these procedures with each other. STUDY DESIGN AND METHODS: This was a retrospective investigation and 82 patients who underwent surgery after an isolated proximal radius fracture were included. Fracture types were classified according to the AO (working group for osteosynthesis questions)/OTA (Orthopedic Trauma Association) classification. The preoperative and postoperative degrees of axis deviation were compared and were considered to be a measure of the quality of treatment. RESULTS: The lowest degree of axis deviation resulted by open reduction and implantation of K­wires (15,8°) and implantation of headless compression screws (HCS, 16°). Closed reduction without any fixation resulted in 19°, with implantation of an TEN (titan elastic nail) in 20° and the open reduction without any fixation resulted in 21° of axis deviation. No correlation was observed concerning the fracture type and the postoperative axis deviation. CONCLUSION: The study shows that the postoperative result does not depend on the fracture type (according to the AO/OTA classification) but on the surgical procedure. Despite the good radiological results in open reduction and internal fixation this procedure should be reserved for difficult situations in which less invasive surgical procedures fail, to avoid aseptic bone necrosis.


Assuntos
Fraturas do Rádio , Criança , Adulto , Humanos , Adolescente , Fraturas do Rádio/diagnóstico por imagem , Pinos Ortopédicos , Estudos Retrospectivos , Consolidação da Fratura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa