Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
Am J Physiol Regul Integr Comp Physiol ; 327(1): R109-R121, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38766772

RESUMO

Rhythmic feeding behavior is critical for regulating phase and amplitude in the ≈24-h variation of heart rate (RR intervals), ventricular repolarization (QT intervals), and core body temperature in mice. We hypothesized changes in cardiac electrophysiology associated with feeding behavior were secondary to changes in core body temperature. Telemetry was used to record electrocardiograms and core body temperature in mice during ad libitum-fed conditions and after inverting normal feeding behavior by restricting food access to the light cycle. Light cycle-restricted feeding modified the phase and amplitude of 24-h rhythms in RR and QT intervals, and core body temperature to realign with the new feeding time. Changes in core body temperature alone could not account for changes in phase and amplitude in the ≈24-h variation of the RR intervals. Heart rate variability analysis and inhibiting ß-adrenergic and muscarinic receptors suggested that changes in the phase and amplitude of 24-h rhythms in RR intervals were secondary to changes in autonomic signaling. In contrast, changes in QT intervals closely mirrored changes in core body temperature. Studies at thermoneutrality confirmed that the daily variation in QT interval, but not RR interval, primarily reflected daily changes in core body temperature (even in ad libitum-fed conditions). Correcting the QT interval for differences in core body temperature helped unmask QT interval prolongation after starting light cycle-restricted feeding and in a mouse model of long QT syndrome. We conclude feeding behavior alters autonomic signaling and core body temperature to regulate phase and amplitude in RR and QT intervals, respectively.NEW & NOTEWORTHY We used time-restricted feeding and thermoneutrality to demonstrate that different mechanisms regulate the 24-h rhythms in heart rate and ventricular repolarization. The daily rhythm in heart rate reflects changes in autonomic input, whereas daily rhythms in ventricular repolarization reflect changes in core body temperature. This novel finding has major implications for understanding 24-h rhythms in mouse cardiac electrophysiology, arrhythmia susceptibility in transgenic mouse models, and interpretability of cardiac electrophysiological data acquired in thermoneutrality.


Assuntos
Temperatura Corporal , Ritmo Circadiano , Comportamento Alimentar , Frequência Cardíaca , Camundongos Endogâmicos C57BL , Animais , Ritmo Circadiano/fisiologia , Frequência Cardíaca/fisiologia , Comportamento Alimentar/fisiologia , Masculino , Temperatura Corporal/fisiologia , Camundongos , Eletrocardiografia , Fotoperíodo , Fatores de Tempo , Sistema Nervoso Autônomo/fisiologia
2.
Europace ; 25(3): 828-834, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36748366

RESUMO

AIMS: Cardioversion is a very commonly performed procedure for persistent atrial fibrillation (AF). However, there is no well-defined protocol to address failed external electrical direct current cardioversion. The aim of the study is to test the efficacy of a pre-defined stepwise cardioversion protocol for patients with persistent AF of ≤12 months. Success was the achievement of sinus rhythm. METHODS AND RESULTS: The study population included patients with persistent AF of ≤12 months duration requiring rhythm management. Patients were offered cardioversion using a pre-defined stepwise protocol using different electrode placement locations, applying compression at end of expiration, and higher energy delivered simultaneously through two defibrillators. : A total of 414 patients were included in the study, of which 362 (87.4%) required a single successful cardioversion. The remaining 52 (12.5%) patients required additional cardioversion attempts using the stepwise cardioversion protocol with an overall success rate of 99.3%. Two simultaneous defibrillators were required in 14 patients (3.4%). Patients with multiple cardioversions (13.5%) experienced more local skin irritation and pain compared with patients with single cardioversion (13.5% vs. 3.5%, P = 0.004). The predictor for the need for multiple cardioversion attempts is high body mass index, while high transthoracic impedance is associated with failed cardioversion. No major complications were observed during the study. CONCLUSION: The stepwise cardioversion protocol has a high success rate of >99% and can be safely performed in outpatient or inpatient settings.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Resultado do Tratamento , Índice de Massa Corporal , Recidiva
3.
Ann Noninvasive Electrocardiol ; 28(3): e13051, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36811259

RESUMO

AIMS: To summarize published case reports of patients diagnosed with coronavirus disease 2019 (COVID-19) and Brugada pattern electrocardiogram (ECG). METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist were followed. A literature search was conducted using PubMed, EMBASE, and Scopus up until September 2021. The incidence, clinical characteristics, and management outcomes of COVID-19 patients with a Brugada pattern ECG were identified. RESULTS: A total of 18 cases were collected. The mean age was 47.1 years and 11.1% were women. No patients had prior confirmed diagnosis of Brugada syndrome. The most common presenting clinical symptoms were fever (83.3%), chest pain (38.8%), shortness of breath (38.8%), and syncope (16.6%). All 18 patients presented with type 1 Brugada pattern ECG. Four patients (22.2%) underwent left heart catheterization, and none demonstrated the presence of obstructive coronary disease. The most common reported therapies included antipyretics (55.5%), hydroxychloroquine (27.7%), and antibiotics (16.6%). One patient (5.5%) died during hospitalization. Three patients (16.6%) who presented with syncope received either an implantable cardioverter defibrillator or wearable cardioverter defibrillator at discharge. At follow-up, 13 patients (72.2%) had resolution of type 1 Brugada pattern ECG. CONCLUSION: COVID-19-associated Brugada pattern ECG seems relatively rare. Most patients had resolution of the ECG pattern once their symptoms have improved. Increased awareness and timely use of antipyretics is warranted in this population.


Assuntos
Antipiréticos , Síndrome de Brugada , COVID-19 , Desfibriladores Implantáveis , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Eletrocardiografia/efeitos adversos , COVID-19/complicações , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Desfibriladores Implantáveis/efeitos adversos , Síncope/etiologia
4.
J Clin Monit Comput ; 37(2): 409-420, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36149575

RESUMO

We recently developed a model-based method for analyzing multiple breath nitrogen washout data that does not require identification of Phase-III. In the present study, we assessed the effect of irregular breathing patterns on the intra-subject variabilities of the model parameters. Nitrogen fraction at the mouth was measured in 18 healthy and 20 asthmatic subjects during triplicate performances of multiple breath nitrogen washout, during controlled (target tidal volume 1 L at 8-12 breaths per minute) and free (unrestricted) breathing. The parameters Scond, Sacin and functional residual capacity (FRC) were obtained by conventional analysis of the slope of Phase-III. Fitting the model to the washout data provided functional residual capacity (FRCM), dead space volume (VD), the coefficient of variation of regional specific ventilation ([Formula: see text]), and the model equivalent of Sacin (Sacin-M). Intra-participant coefficients of variation for the model parameters for both health and asthma were FRCM < 5.2%, VD < 5.4%, [Formula: see text] < 9.0%, and Sacin-M < 45.6% for controlled breathing, and FRCM < 4.6%, VD < 5.3%, [Formula: see text] < 13.2%, and Sacin-M < 103.2% for free breathing. The coefficients of variation limits for conventional parameters were FRC < 6.1%, with Scond < 73.6% and Sacin < 49.2% for controlled breathing and Scond < 35.0% and Sacin < 74.4% for free breathing. The model-fitting approach to multiple breath nitrogen washout analysis provides a measure of regional ventilation heterogeneity in [Formula: see text] that is less affected by irregularities in the breathing pattern than its corresponding Phase-III slope analysis parameter Scond.


Assuntos
Asma , Nitrogênio , Humanos , Testes de Função Respiratória/métodos , Pulmão , Respiração
5.
Respirology ; 27(4): 262-276, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35178831

RESUMO

Oxygen is a life-saving therapy but, when given inappropriately, may also be hazardous. Therefore, in the acute medical setting, oxygen should only be given as treatment for hypoxaemia and requires appropriate prescription, monitoring and review. This update to the Thoracic Society of Australia and New Zealand (TSANZ) guidance on acute oxygen therapy is a brief and practical resource for all healthcare workers involved with administering oxygen therapy to adults in the acute medical setting. It does not apply to intubated or paediatric patients. Recommendations are made in the following six clinical areas: assessment of hypoxaemia (including use of arterial blood gases); prescription of oxygen; peripheral oxygen saturation targets; delivery, including non-invasive ventilation and humidified high-flow nasal cannulae; the significance of high oxygen requirements; and acute hypercapnic respiratory failure. There are three sections which provide (1) a brief summary, (2) recommendations in detail with practice points and (3) a detailed explanation of the reasoning and evidence behind the recommendations. It is anticipated that these recommendations will be disseminated widely in structured programmes across Australia and New Zealand.


Assuntos
Oxigenoterapia , Adulto , Criança , Humanos , Hipóxia/terapia , Nova Zelândia , Oxigênio
6.
Soc Networks ; 70: 284-294, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35600208

RESUMO

Using longitudinal data from UCNets, we examined newly-listed alters and distinguished between truly new ties who were recently met (typically coworkers and acquaintances) and awakened ties who were previously known to ego (typically extended kin and friends). Half of the newly-listed ties among the younger respondents were truly new, whereas two-thirds among the older respondents were awakened. In both groups, however, most alters were previously listed. These ties mainly included kin, confidants, and advisors, suggesting stability in the network core. Methodological implications for the name-generating process and substantive implications for the understanding of network dynamics and structure are discussed.

7.
N Engl J Med ; 379(13): 1205-1215, 2018 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-30280654

RESUMO

BACKGROUND: Despite the high rate of sudden death after myocardial infarction among patients with a low ejection fraction, implantable cardioverter-defibrillators are contraindicated until 40 to 90 days after myocardial infarction. Whether a wearable cardioverter-defibrillator would reduce the incidence of sudden death during this high-risk period is unclear. METHODS: We randomly assigned (in a 2:1 ratio) patients with acute myocardial infarction and an ejection fraction of 35% or less to receive a wearable cardioverter-defibrillator plus guideline-directed therapy (the device group) or to receive only guideline-directed therapy (the control group). The primary outcome was the composite of sudden death or death from ventricular tachyarrhythmia at 90 days (arrhythmic death). Secondary outcomes included death from any cause and nonarrhythmic death. RESULTS: Of 2302 participants, 1524 were randomly assigned to the device group and 778 to the control group. Participants in the device group wore the device for a median of 18.0 hours per day (interquartile range, 3.8 to 22.7). Arrhythmic death occurred in 1.6% of the participants in the device group and in 2.4% of those in the control group (relative risk, 0.67; 95% confidence interval [CI], 0.37 to 1.21; P=0.18). Death from any cause occurred in 3.1% of the participants in the device group and in 4.9% of those in the control group (relative risk, 0.64; 95% CI, 0.43 to 0.98; uncorrected P=0.04), and nonarrhythmic death in 1.4% and 2.2%, respectively (relative risk, 0.63; 95% CI, 0.33 to 1.19; uncorrected P=0.15). Of the 48 participants in the device group who died, 12 were wearing the device at the time of death. A total of 20 participants in the device group (1.3%) received an appropriate shock, and 9 (0.6%) received an inappropriate shock. CONCLUSIONS: Among patients with a recent myocardial infarction and an ejection fraction of 35% or less, the wearable cardioverter-defibrillator did not lead to a significantly lower rate of the primary outcome of arrhythmic death than control. (Funded by the National Institutes of Health and Zoll Medical; VEST ClinicalTrials.gov number, NCT01446965 .).


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Infarto do Miocárdio/terapia , Taquicardia Ventricular/prevenção & controle , Dispositivos Eletrônicos Vestíveis , Idoso , Morte Súbita Cardíaca/etiologia , Desfibriladores/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Volume Sistólico , Taquicardia Ventricular/mortalidade , Resultado do Tratamento , Dispositivos Eletrônicos Vestíveis/efeitos adversos
8.
J Cardiovasc Electrophysiol ; 32(6): 1772-1777, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33969588

RESUMO

Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common sustained supraventricular arrhythmias. An understanding of gender-related differences in AVNRT epidemiology, diagnosis, treatment, outcome, and complications can help guide a more effective diagnosis and treatment of the condition. The study aimed to perform a review of the available literature regarding all aspects of gender-related differences of AVNRT. We focused on all aspects of gender-related differences regarding AVNRT between men and women. A literature search was performed using Google Scholar, PubMed, Springer, Ovid, and Science Direct. Many investigations have demonstrated that the prevalence of AVNRT exhibited a twofold women-to-men predominance. The potential mechanism behind this difference due to sex hormones and autonomic tone. Despite being more common in women, there is a delay in offering and performing the first-line therapy (catheter ablation) compared to men. There were no significant gender-related discrepancies in patients who underwent ablation therapy for AVNRT, regarding the acute success rate of the procedure, long-term success rate, and recurrence of AVNRT. AVNRT is more common in women due to physiological factors such as sex hormones and autonomic tone. Catheter ablation is equally safe and efficacious in men and women; however, the time between the onset of symptoms and ablation is significantly prolonged in women. It is important for the medical community to be aware of this discrepancy and to strive to eliminate such disparities that are not related to patients' choices.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ventricular , Arritmias Cardíacas , Feminino , Humanos , Masculino , Recidiva , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/epidemiologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Resultado do Tratamento
9.
Med J Aust ; 215(6): 280-285, 2021 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-34382211

RESUMO

Endoscopic lung volume reduction (ELVR) is recognised in both national and international expert guidelines as one of the few additive treatments to benefit patients with advanced chronic obstructive pulmonary disease (COPD) who are otherwise receiving optimal medical and supportive care. Despite these recommendations and a growing evidence base, these procedures are not widely offered across Australia and New Zealand, and general practitioner and physician awareness of this therapy can be improved. ELVR aims to mitigate the impact of hyperinflation and gas trapping on dyspnoea and exercise intolerance in COPD. Effective ELVR is of proven benefit in improving symptoms, quality of life, lung function and survival. Several endoscopic techniques to achieve ELVR have been developed, with endobronchial valve placement to collapse a single lobe being the most widely studied and commonly practised. This review describes the physiological rationale underpinning lung volume reduction, highlights the challenges of patient selection, and provides an overview of the evidence for current and investigational endoscopic interventions for COPD.


Assuntos
Broncoscopia/métodos , Dispneia/fisiopatologia , Pneumonectomia/instrumentação , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/cirurgia , Austrália/epidemiologia , Conscientização , Broncoscopia/normas , Humanos , Nova Zelândia/epidemiologia , Seleção de Pacientes/ética , Pneumonectomia/métodos , Pneumonectomia/mortalidade , Guias de Prática Clínica como Assunto , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Residual/fisiologia , Instrumentos Cirúrgicos/efeitos adversos , Sobrevida , Capacidade Pulmonar Total/fisiologia
10.
Respirology ; 26(6): 566-573, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33797141

RESUMO

BACKGROUND AND OBJECTIVE: Asthma guidelines emphasize the importance of assessing lung function and symptoms. The forced oscillation technique (FOT) and its longitudinal relationship with spirometry and symptoms are unresolved. We examined concordance between longitudinal spirometry, FOT and symptom control, and determined FOT limits of agreement in stable asthma. METHODS: Over a 3-year period, adults with asthma attending a tertiary clinic completed the asthma control test (ACT), fraction of exhaled nitric oxide (FeNO), FOT and spirometry. Analysis included between-visit concordance for significant change using Cohen's kappa (κ) and stable asthma FOT limits of agreement. RESULTS: Data (n = 186) from 855 visits (mean ± SD 4.6 ± 3.0 visits), 114 ± 95 days apart, were analysed. Between-visit concordance was moderate between reactance at 5 Hz (X5) and forced expiratory volume in 1 s (FEV1 ) (κ = 0.34, p = 0.001), and weak between ACT and FEV1 (κ = 0.18, p = 0.001). Change in FeNO did not correlate with lung function or ACT (κ < 0.05, p > 0.1). Stable asthma between visits (n = 75; 132 visits) had reduced lung function variability, but comparable concordance to the entire cohort. Limits of agreement for FEV1 (0.42 L), resistance at 5 Hz (2.06 cm H2 O s L-1 ) and X5 (2.75 cm H2 O s L-1 ) in stable asthma were at least twofold greater than published values in health. CONCLUSION: In adults with asthma, there is moderate concordance between longitudinal change in FOT and spirometry. Both tests relate poorly to changes in asthma control, highlighting the need for multi-modal assessment in asthma rather than symptoms alone. The derivation of longitudinal FOT limits of agreement will assist in its clinical interpretation.


Assuntos
Asma , Adulto , Asma/diagnóstico , Volume Expiratório Forçado , Humanos , Oscilometria/métodos , Testes de Função Respiratória , Espirometria/métodos
11.
Eur Respir J ; 55(5)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32139466

RESUMO

The recently published Global Lung Function Initiative (GLI) carbon monoxide transfer factor (T LCO) reference equations provide an opportunity to adopt a current, all-age, widely applicable reference set. The aim of this study was to document the effect of changing to GLI from commonly utilised reference equations on the interpretation of T LCO results.33 863 T LCO results (48% female, 88% Caucasian, n=930 aged <18 years) from clinical pulmonary function laboratories within three Australian teaching hospitals were analysed. The lower limit of normal (LLN) and proportion of patients with a T LCO below this value were calculated using GLI and other commonly used reference equations.The average T LCO LLN for GLI was similar or lower than the other equations, with the largest difference seen for Crapo equations (median: -1.25, IQR: -1.64, -0.86 mmol·min-1·kPa-1). These differences resulted in altered rates of reduced T LCO for GLI particularly for adults (+1.9% versus Miller to -27.6% versus Crapo), more so than for children (-0.8% versus Kim to -14.2% versus Cotes). For adults, the highest raw agreement for GLI was with Miller equations (94.7%), while for children it was with Kim equations (98.1%). Results were reclassified from abnormal to normal more frequently for younger adults, and for adult females, particularly when moving from Roca to GLI equations (30% of females versus 16% of males).The adoption of GLI T LCO reference equations in adults will result in altered interpretation depending on the equations previously used and to a greater extent in adult females. The effect on interpretation in children is less significant.


Assuntos
Monóxido de Carbono/sangue , Pulmão/fisiologia , Testes de Função Respiratória , População Branca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Monóxido de Carbono/metabolismo , Criança , Feminino , Hospitais de Ensino , Humanos , Cooperação Internacional , Pulmão/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Valores de Referência , Sociedades Médicas , Espirometria , Adulto Jovem
12.
Eur Respir J ; 56(3)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32430416

RESUMO

BACKGROUND: Telemonitoring trials for early detection of acute exacerbations of chronic obstructive pulmonary disease (AECOPD) have provided mixed results. Day-to-day variations in lung function measured by the forced oscillation technique (FOT) may yield greater insight. We evaluated the clinical utility of home telemonitoring of variability in FOT measures in terms of 1) the relationship with symptoms and quality of life (QoL); and 2) the timing of variability of FOT measures and symptom changes prior to AECOPD. METHODS: Daily FOT parameters at 5 Hz (resistance (R) and reactance (X); Resmon Pro Diary, Restech Srl, Milan, Italy), daily symptoms (COPD Assessment Test (CAT)) and 4-weekly QoL data (St George's Respiratory Questionnaire (SGRQ)) were recorded over 8-9 months from chronic obstructive pulmonary disease (COPD) patients. Variability of R and X was calculated as the standard deviation (sd) over 7-day running windows and we also examined the effect of varying window size. The relationship of FOT versus CAT and SGRQ was assessed using linear mixed modelling, daily changes in FOT variability and CAT prior to AECOPD using one-way repeated measures ANOVA. RESULTS: Fifteen participants with a mean±sd age of 69±10 years and a % predicted forced expiratory volume in 1 s (FEV1) of 39±10% had a median (interquartile range (IQR)) adherence of 95.4% (79.0-98.8%). Variability of the inspiratory component of X (indicated by the standard deviation of inspiratory reactance (SDXinsp)) related to CAT and weakly to SGRQ (fixed effect estimates 1.57, 95% CI 0.65-2.49 (p=0.001) and 4.41, 95% CI -0.06 to 8.89 (p=0.05), respectively). SDXinsp changed significantly on the same day as CAT (1 day before AECOPD, both p=0.02) and earlier when using shorter running windows (3 days before AECOPD, p=0.01; accuracy=0.72 for 5-day windows). CONCLUSIONS: SDXinsp from FOT telemonitoring reflects COPD symptoms and may be a sensitive biomarker for early detection of AECOPD.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Qualidade de Vida , Volume Expiratório Forçado , Humanos , Itália , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Testes de Função Respiratória
13.
Eur Respir J ; 55(5)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32139455

RESUMO

Severe asthma is a high-burden disease. Real-world data on mepolizumab in patients with severe eosinophilic asthma is needed to assess whether the data from randomised controlled trials are applicable in a broader population.The Australian Mepolizumab Registry (AMR) was established with an aim to assess the use, effectiveness and safety of mepolizumab for severe eosinophilic asthma in Australia.Patients (n=309) with severe eosinophilic asthma (median age 60 years, 58% female) commenced mepolizumab. They had poor symptom control (median Asthma Control Questionnaire (ACQ)-5 score of 3.4), frequent exacerbations (median three courses of oral corticosteroids (OCS) in the previous 12 months), and 47% required daily OCS. Median baseline peripheral blood eosinophil level was 590 cells·µL-1 Comorbidities were common: allergic rhinitis 63%, gastro-oesophageal reflux disease 52%, obesity 46%, nasal polyps 34%.Mepolizumab treatment reduced exacerbations requiring OCS compared with the previous year (annualised rate ratio 0.34 (95% CI 0.29-0.41); p<0.001) and hospitalisations (rate ratio 0.46 (95% CI 0.33-0.63); p<0.001). Treatment improved symptom control (median ACQ-5 reduced by 2.0 at 6 months), quality of life and lung function. Higher blood eosinophil levels (p=0.003) and later age of asthma onset (p=0.028) predicted a better ACQ-5 response to mepolizumab, whilst being male (p=0.031) or having body mass index ≥30 (p=0.043) predicted a lesser response. Super-responders (upper 25% of ACQ-5 responders, n=61, 24%) had a higher T2 disease burden and fewer comorbidities at baseline.Mepolizumab therapy effectively reduces the significant and long-standing disease burden faced by patients with severe eosinophilic asthma in a real-world setting.


Assuntos
Antiasmáticos/administração & dosagem , Anticorpos Monoclonais Humanizados/administração & dosagem , Asma/tratamento farmacológico , Eosinófilos/efeitos dos fármacos , Administração Oral , Corticosteroides/administração & dosagem , Idoso , Antiasmáticos/efeitos adversos , Anticorpos Monoclonais Humanizados/efeitos adversos , Austrália , Progressão da Doença , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Índice de Gravidade de Doença
14.
J Cardiovasc Electrophysiol ; 31(6): 1394-1402, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32270562

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation but the recurrence rate remains relatively high in persistent patients with AF. Therefore, posterior wall isolation (PWI) in addition to PVI has been proposed to increase freedom from AF. OBJECTIVE: To evaluate the success of adjunctive PWI in persistent AF. METHODS: We searched electronic database using specific terms. The primary outcomes are recurrence rate of AF and recurrence of atrial arrhythmias. The secondary outcomes were atrial flutter/tachycardia (AFL/AT), procedure time, fluoroscopy time, and procedure related complications. Estimated risk ratios (RRs) and 95% confidence intervals (CIs) were evaluated. RESULTS: Six studies were included (1334 patients with persistent AF). Adjunctive PWI resulted in a significant reduction in the recurrence rate of AF compared with patients who had PVI only (19.8% vs 29.1%; RR, 0.64; 95% CI, 0.42-0.97; P < .04; I2 = 76%). There was a significant reduction in the recurrence rate of all atrial arrhythmia (30.8% vs 41.1%; RR, 0.75; 95% CI, 0.60-0.94; P < .01; I2 = 60%). Compared with PVI only, adjunctive PWI did not increase the rate of AFL or AT (11.6% vs 13.9%; RR, 0.85; 95% CI, 0.54-1.32; P < .46; I2 = 47%) or the rate of procedure related complications (4.6% vs 3.6%; RR, 1.25; 95% CI, 0.72-2.17; P < .44; I2 = 0%). CONCLUSION: In patients with persistent AF, adjunctive PWI was associated with decreased recurrence of AF and atrial arrhythmias compared with PVI alone without an increased risk of AFL or AT or procedure related complications.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo
15.
Pharmacol Res ; 159: 105029, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32565310

RESUMO

Asthma and COPD make up the majority of obstructive airways diseases (OADs), which affects ∼11 % of the population. The main drugs used to treat OADs have not changed in the past five decades, with advancements mainly comprising variations on existing treatments. The recent biologics are beneficial to only specific subsets of patients. Part of this may lie in our inability to adequately characterise the tremendous heterogeneity in every aspect of OAD. The field is currently moving towards the concept of personalised medicine, based on a focus on treatable traits that are objective, measurable and modifiable. We propose extending this concept via the use of emerging clinical tools for comprehensive physiological phenotyping. We describe, based on published data, the evidence for the use of functional imaging, gas washout techniques and oscillometry, as well as potential future applications, to more comprehensively assess and predict treatment response in OADs. In this way, we hope to demonstrate how physiological phenotyping tools will improve the way in which drugs are prescribed, but most importantly, will facilitate development of new drugs for OADs.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico , Pneumopatias Obstrutivas/diagnóstico , Pulmão/diagnóstico por imagem , Testes de Função Respiratória , Obstrução das Vias Respiratórias/tratamento farmacológico , Obstrução das Vias Respiratórias/fisiopatologia , Animais , Tomada de Decisão Clínica , Desenvolvimento de Medicamentos , Humanos , Pulmão/efeitos dos fármacos , Pulmão/fisiopatologia , Pneumopatias Obstrutivas/tratamento farmacológico , Pneumopatias Obstrutivas/fisiopatologia , Medidas de Resultados Relatados pelo Paciente , Fenótipo , Valor Preditivo dos Testes , Medicamentos para o Sistema Respiratório/uso terapêutico
16.
Med J Aust ; 213(7): 316-320, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32906192

RESUMO

OBJECTIVE: To estimate the level of dispensing of oral corticosteroids (OCS) for managing asthma in Australia, with a particular focus on the cumulative dispensing of doses associated with long term toxicity (≥ 1000 mg prednisolone-equivalent). DESIGN: Retrospective cohort study; analysis of 10% random sample of Pharmaceutical Benefits Scheme (PBS) dispensing data. PARTICIPANTS, SETTING: People aged 12 years or more treated for asthma during 2014-2018, according to dispensing of controller inhaled corticosteroids (ICS). MAIN OUTCOME MEASURES: Number of people dispensed OCS for managing asthma during 2014-2018; proportion who were cumulatively dispensed at least 1000 mg prednisolone-equivalent. The secondary outcome was the number of people dispensed at least 1000 mg prednisolone-equivalent during 2018, stratified by inhaler controller dose and use. RESULTS: 124 011 people had been dispensed at least two prescriptions of ICS during 2014-2018 and met the study definition for asthma, of whom 64 112 (51.7%) had also been dispensed OCS, including 34 580 (27.9% of the asthma group) cumulatively dispensed 1000 mg prednisolone-equivalent or more. Of 138 073 people dispensed OCS at this level, 68 077 (49%) were patients with airway diseases. Dispensing of diabetes and osteoporosis medications was more common for people cumulatively dispensed 1000 mg prednisolone-equivalent or more. During 2018, 4633 people with asthma using high dose ICS controllers were dispensed 1000 mg prednisolone-equivalent or more, for 2316 of whom (50%) controller use was inadequate. CONCLUSIONS: Cumulative exposure to OCS in Australia reaches levels associated with toxicity in one-quarter of patients with asthma using ICS. Cumulative dispensing of potentially toxic OCS amounts often accompanies inadequate inhaler controller dispensing. Better approaches are needed to improve adherence to controller therapy, improve outcomes for people with asthma, and to minimise the use and toxicity of OCS.


Assuntos
Corticosteroides/administração & dosagem , Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Prescrições de Medicamentos/estatística & dados numéricos , Administração Oral , Adolescente , Corticosteroides/toxicidade , Adulto , Antiasmáticos/toxicidade , Austrália , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
17.
Pacing Clin Electrophysiol ; 43(3): 341-349, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32067241

RESUMO

BACKGROUND: Using synthetic antibiotic-eluting envelope (ABE) is an effective intervention for prevention of cardiovascular implantable electronic device (CIED) infection. The biologic extracellular-matrix envelope (ECME), may offer potential advantages over the synthetic ABE. To further minimize the risk of infection, the ECME can be hydrated in gentamicin prior to CIED implantation. We aimed to evaluate the efficacy and pharmacokinetics (PK) of gentamicin containing ECME in an animal model. METHODS: For all experiments, the ECME was hydrated in gentamicin (40 mg/Ml) (treatment) for 2 min. In vitro antimicrobial efficacy against six different bacterial species was assessed. In vivo experiments were conducted using a rabbit model of CIED pocket infection. Serum and ECM gentamicin concentrations were measured. Five different organisms were inoculated into the device pocket of control (ECME hydrated in 0.9% saline) and treatment groups. Macroscopic appearance and colony forming units from CIED, ECME, and tissue were determined. RESULTS: No bacteria were recovered from any culture after 12 h of exposure to the gentamicin containing ECME. Serum gentamicin levels dropped below the limit of quantification at 15 h after implant. Gentamicin concentration in the ECME remained relatively stable for up to 7 days. Signs of clinical infection were observed in the control but not in the treatment group. In the presence of gentamicin, statistically significant reduction was demonstrated across all tested bacterial species. CONCLUSIONS: In this preclinical animal infection model, gentamicin containing ECME was highly effective in reducing bacterial burden in the implant pocket, while systemic exposure after implantation remained low.


Assuntos
Antibacterianos/administração & dosagem , Antibacterianos/farmacocinética , Gentamicinas/administração & dosagem , Gentamicinas/farmacocinética , Marca-Passo Artificial , Infecções Relacionadas à Prótese/prevenção & controle , Animais , Modelos Animais de Doenças , Matriz Extracelular , Infecções Relacionadas à Prótese/microbiologia , Coelhos , Células-Tronco
18.
Respirology ; 25(6): 613-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31482693

RESUMO

BACKGROUND AND OBJECTIVE: Fixed airflow obstruction (FAO) in asthma occurs despite optimal inhaled treatment and no smoking history, and remains a significant problem, particularly with increasing age and duration of asthma. Increased lung compliance and loss of lung elastic recoil has been observed in older people with asthma, but their link to FAO has not been established. We determined the relationship between abnormal lung elasticity and airflow obstruction in asthma. METHODS: Non-smoking asthmatic subjects aged >40 years, treated with 2 months of high-dose inhaled corticosteroid/long-acting beta-agonist (ICS/LABA), had FAO measured by spirometry, and respiratory system resistance at 5 Hz (Rrs5 ) and respiratory system reactance at 5 Hz (Xrs5 ) measured by forced oscillation technique. Lung compliance (K) and elastic recoil (B/A) were calculated from pressure-volume curves measured by an oesophageal balloon. Linear correlations between K and B/A, and forced expiratory volume in 1 s/forced vital capacity (FEV1 /FVC), Rrs5 and Xrs5 were assessed. RESULTS: Eighteen subjects (11 males; mean ± SD age: 64 ± 8 years, asthma duration: 39 ± 22 years) had moderate FAO measured by spirometry ((mean ± SD z-score) post-bronchodilator FEV1 : -2.2 ± 0.5, FVC: -0.7 ± 1.0, FEV1 /FVC: -2.6 ± 0.7) and by increased Rrs5 (median (IQR) z-score) 2.7 (1.9 to 3.2) and decreased Xrs5 : -4.1(-2.4 to -7.3). Lung compliance (K) was increased in 9 of 18 subjects and lung elastic recoil (B/A) reduced in 5 of 18 subjects. FEV1 /FVC correlated negatively with K (rs = -0.60, P = 0.008) and Rrs5 correlated negatively with B/A (rs = -0.52, P = 0.026), independent of age. Xrs5 did not correlate with lung elasticity indices. CONCLUSION: Increased lung compliance and loss of elastic recoil relate to airflow obstruction in older non-smoking asthmatic subjects, independent of ageing. Thus, structural lung tissue changes may contribute to persistent, steroid-resistant airflow obstruction. CLINICAL TRIAL REGISTRATION: ACTRN126150000985583 at anzctr.org.au (UTN: U1111-1156-2795).


Assuntos
Corticosteroides/uso terapêutico , Asma/tratamento farmacológico , Volume Expiratório Forçado/fisiologia , Complacência Pulmonar/fisiologia , Capacidade Vital/fisiologia , Idoso , Asma/patologia , Elasticidade/efeitos dos fármacos , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica , Testes de Função Respiratória/métodos , Espirometria/métodos
19.
Soc Networks ; 61: 78-86, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-35875821

RESUMO

High rates of egocentric network turnover are frequently observed but not well explained. About 1,000 respondents to the UCNets survey named an average of 10 names in each of two waves a year apart. Consistent with prior studies, respondents in wave 2 failed to relist about half of the names they provided in wave 1. Asked why, respondents explained that they had forgotten the alter for about 40 percent of the missing names. Other common answers, such as no "occasion... to be in touch," also suggest that the true rate of alters being dropped is probably under 20 percent. Multilevel logit models identified the predictors of alters being dropped (neither relisted nor forgotten) versus retained. Immediate kin were likeliest to be retained and roommates, coworkers, and acquaintances to be dropped. Alters who provided companionship, confiding, advice, and emergency help were especially likely to be retained, as were those to whom respondents felt close. Little about the respondents themselves affected drop rates: having moved recently, having a close friend die, or having had an important relationship break up. Results are consistent with the argument that a tie's degree of constraint (notably being close family) and its balance of rewards determine the likelihood of it being dropped or demoted.

20.
Catheter Cardiovasc Interv ; 93(7): E385-E390, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30302907

RESUMO

OBJECTIVE: We aimed to investigate the current practice patterns of permanent pacing, especially the timing of implantation, for high-degree AV block (HDAVB) following transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). BACKGROUND: Comparative data regarding current practice patterns of permanent pacing for HDAVB between TAVI and SAVR is limited. METHODS: Using the National Inpatient Sample database, we identified patients who underwent TAVI or SAVR between 2012 and 2014. The incidence of HDAVB, the rate of permanent pacemaker implantation, and the timing of implantations were compared between TAVI and SAVR groups. RESULTS: We identified 33 690 and 202 110 patients who underwent TAVI and SAVR, respectively. HDAVB occurred in 3480 patients (10.3%) in the TAVI group and 11 405 patients (5.6%) in the SAVR group (P < 0.001). Among the patients who developed HDAVB, patients in the TAVI group were more likely to undergo permanent pacemaker implantation than those in the SAVR group (74.1% vs 64.7%; P < 0.001). The median interval from TAVI to pacemaker implantation was 2 days (interquartile range 1-3 days) vs 5 days (interquartile range 3-7 days) from SAVR to pacemaker implantation (P < 0.001). Among the patients who developed HDAVB, TAVI was associated with higher rates of permanent pacemaker implantation after adjusting for other comorbidities (odds ratio 1.41:95% confidence interval 1.13-1.77; P = 0.003). CONCLUSIONS: HDAVB occurred more commonly after TAVI compared to SAVR. HDAVB after TAVI compared to SAVR was associated with a higher rate of permanent pacemaker implantation at an earlier timing from the index procedure.


Assuntos
Valva Aórtica/cirurgia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/tendências , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/tendências , Padrões de Prática Médica/tendências , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Bases de Dados Factuais , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar/tendências , Humanos , Incidência , Pacientes Internados , Tempo de Internação/tendências , Masculino , Fatores de Risco , Fatores de Tempo , Tempo para o Tratamento/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa