Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Eur Radiol ; 32(12): 8726-8736, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35639145

RESUMO

OBJECTIVES: To date, there are no data on the noninvasive surrogate of intratumoural immune status that could be prognostic of survival outcomes in non-small cell lung cancer (NSCLC). We aimed to develop and validate the immune ecosystem diversity index (iEDI), an imaging biomarker, to indicate the intratumoural immune status in NSCLC. We further investigated the clinical relevance of the biomarker for survival prediction. METHODS: In this retrospective study, two independent NSCLC cohorts (Resec1, n = 149; Resec2, n = 97) were included to develop and validate the iEDI to classify the intratumoural immune status. Paraffin-embedded resected specimens in Resec1 and Resec2 were stained by immunohistochemistry, and the density percentiles of CD3+, CD4+, and CD8+ T cells to all cells were quantified to estimate intratumoural immune status. Then, EDI features were extracted using preoperative computed tomography to develop an imaging biomarker, called iEDI, to determine the immune status. The prognostic value of iEDI was investigated on NSCLC patients receiving surgical resection (Resec1; Resec2; internal cohort Resec3, n = 419; external cohort Resec4, n = 96; and TCIA cohort Resec5, n = 55). RESULTS: iEDI successfully classified immune status in Resec1 (AUC 0.771, 95% confidence interval [CI] 0.759-0.783; and 0.770 through internal validation) and Resec2 (0.669, 0.647-0.691). Patients with higher iEDI-score had longer overall survival (OS) in Resec3 (unadjusted hazard ratio 0.335, 95%CI 0.206-0.546, p < 0.001), Resec4 (0.199, 0.040-1.000, p < 0.001), and TCIA (0.303, 0.098-0.944, p = 0.001). CONCLUSIONS: iEDI is a non-invasive surrogate of intratumoural immune status and prognostic of OS for NSCLC patients receiving surgical resection. KEY POINTS: • Decoding tumour immune microenvironment enables advanced biomarkers identification. • Immune ecosystem diversity index characterises intratumoural immune status noninvasively. • Immune ecosystem diversity index is prognostic for NSCLC patients.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Linfócitos T CD8-Positivos/patologia , Estudos Retrospectivos , Ecossistema , Estadiamento de Neoplasias , Prognóstico , Tomografia Computadorizada por Raios X , Biomarcadores , Microambiente Tumoral
2.
Eur Radiol ; 30(11): 6204-6212, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32548647

RESUMO

OBJECTIVES: To evaluate how pulmonary artery (PA) distensibility performs in detecting pulmonary hypertension due to left heart disease (PH-LHD) in comparison with parameters from ungated computed tomography (CT) and echocardiography. METHODS: One hundred patients (79 men, mean age = 63 ± 17 years) with either severe heart failure with reduced ejection fraction (HFrEF), aortic stenosis, or primary mitral regurgitation prospectively underwent right heart catheterization, ungated CT, ECG-gated CT, and echocardiography. During the ECG-gated CT, the right PA distensibility was calculated. In ungated CT, dPA, dPA/AA, the ratio of dPA to the diameter of the vertebra, segmental PA diameter, segmental PA-to-bronchus ratio, and the main PA volume were measured; the egg-and-banana sign was recorded. During echocardiography, the tricuspid regurgitation (TR) gradient was measured. The areas under the ROC curves (AUC) of these signs were computed and compared with DeLong test. Correlation between PA distensibility and PA pressure (PAP) was investigated through Pearson's coefficient. RESULTS: PA distensibility was lower in patients with PH than in those without PH (11.4 vs. 21.2%, p < 0.001) and correlated negatively with mean PAP (r = - 0.72, p < 0.001). Age, PA size, and mean PAP were independent predictors of PA distensibility. PA distensibility < 18% detected PH-LHD with 96% sensitivity and 73% specificity; its AUC was 0.92, larger than that of any other sign at ungated CT and TR gradient (AUC ranging from 0.54 to 0.83, DeLong: p ranging from 0.020 to < 0.001). CONCLUSION: PA distensibility on an ECG-gated CT can detect PH-LHD better than the parameters reflecting PA dilatation in ungated CT or TR gradient in the echocardiography of patients with severe HFrEF, aortic stenosis, or mitral regurgitation. KEY POINTS: • In left heart disease, pulmonary artery distensibility is lower in patients with PH than in those without pulmonary hypertension (11.4 vs. 21.2%, p < 0.001). • In left heart disease, pulmonary artery distensibility detects pulmonary hypertension with an area under the receiver operating curve of 0.92. • In left heart disease, the area under the receiver operating curve of pulmonary artery distensibility for detecting pulmonary hypertension is larger than that of all other signs at ungated CT (p from 0.019 to < 0.001) and tricuspid regurgitation gradient at echocardiography (p = 0.020).


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Técnicas de Imagem de Sincronização Cardíaca , Ecocardiografia/métodos , Feminino , Coração/fisiopatologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Tamanho do Órgão , Artéria Pulmonar/patologia , Artéria Pulmonar/fisiopatologia , Volume Sistólico , Tomografia Computadorizada por Raios X/métodos
3.
Clin Chem Lab Med ; 58(12): 2141-2150, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33064667

RESUMO

Objectives As severe acute respiratory syndrome coronavirus 2 (SARS-Cov-2) pandemic is increasing its victims on a global scale with recurring outbreaks, it remains of outmost importance to rapidly identify people requiring an intensive care unit (ICU) hospitalization. The aim of this study was to identify Coronavirus Disease 2019 (COVID-19) biomarkers, to investigate their correlation with disease severity and to evaluate their usefulness for follow-up. Methods Fifty patients diagnosed with SARS-Cov-2 were included in March 2020. Clinical and biological data were collected at admission, during hospitalization and one month after discharge. Patients were divided into two severity groups: non-ICU (28) and ICU and/or death (22) to stratify the risk. Results Blood parameters in COVID-19 patients at admission showed increased C-reactive protein (CRP) (100%), ferritin (92%), lactate dehydrogenase (LDH) (80%), white blood cell (WBC) count (26%) with lymphopenia (52%) and eosinopenia (98%). There were significant differences in levels of CRP, ferritin, D-dimers, fibrinogen, lymphocyte count, neutrophil count and neutrophil-to-lymphocyte ratio (NLR) among the two severity groups. Mapping of biomarker's kinetics distinguished early and late parameters. CRP, ferritin, LDH, lymphopenia and eosinopenia were present upon admission with a peak at the first week. Late biomarkers such as anemia, neutrophilia and elevated liver biomarkers appeared after one week with a peak at three weeks of hospitalization. Conclusions We confirmed that high-values of CRP, NLR, D-dimers, ferritin as well as lymphopenia and eosinopenia were consistently found and are good markers for risk stratification. Kinetics of these biomarkers correlate well with COVID-19 severity. Close monitoring of early and late biomarkers is crucial in the management of critical patients to avoid preventable deaths.


Assuntos
Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Contagem de Células Sanguíneas , COVID-19 , Infecções por Coronavirus/sangue , Feminino , Seguimentos , Hemostasia , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/sangue , Prognóstico , Adulto Jovem
4.
Skeletal Radiol ; 48(8): 1261-1268, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30725159

RESUMO

OBJECTIVE: To determine in a cadaveric study the lowest achievable radiation dose and optimal tube potential generating diagnostic image quality in multidetector computed tomography (MDCT) arthrography of the shoulder. MATERIALS AND METHODS: Six shoulders from three human cadavers were scanned using a 256-MDCT system after intra-articular injection of diluted iodinated contrast material. Using six decreasing radiation dose levels (CTDIvol: 20, 15, 10, 8, 6, and 4 mGy) and for each dose level, four decreasing tube potentials (140, 120, 100, and 80 kVp), image noise and contrast-to-noise ratio (CNR) were measured. Two independent and blinded observers assessed the overall diagnostic image quality, subjective amount of noise, and severity of artifacts according to a four-point scale. Influence of those MDCT data acquisition parameters on objective and subjective image quality was analyzed using the Kruskal-Wallis and Wilcoxon signed-rank tests, and pairwise comparisons were performed. RESULTS: Multidetector CT protocols with radiation doses of 15 mGy or higher, combined with tube potentials of 100 kVp or higher, were equivalent in CNR to the reference 20 mGy-140 kVp protocol (all p ≥ 0.054). Above a CTDIvol of 10 mGy and a tube potential of 120 kVp, all protocols generated diagnostic image quality and subjective noise equivalent to the 20 mGy-140 kVp protocol (all p ≥ 0.22). CONCLUSIONS: Diagnostic image quality in MDCT arthrography of the shoulder can be obtained with a radiation dose of 10 mGy at an optimal tube potential of 120 kVp, corresponding to a reduction of up to 50% compared with standard-dose protocols, and as high as 500% compared with reported protocols in the literature.


Assuntos
Artrografia , Tomografia Computadorizada Multidetectores , Doses de Radiação , Articulação do Ombro/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Cadáver , Meios de Contraste , Feminino , Humanos , Masculino , Razão Sinal-Ruído
5.
Eur Radiol ; 28(2): 770-779, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28856413

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of brain CT images reconstructed with a model-based iterative algorithm performed at usual and reduced dose. METHODS: 115 patients with histologically proven lung cancer were prospectively included over 15 months. Patients underwent two CT acquisitions at the initial staging, performed on a 256-slice MDCT, at standard (CTDIvol: 41.4 mGy) and half dose (CTDIvol: 20.7 mGy). Both image datasets were reconstructed with filtered back projection (FBP) and iterative model-based reconstruction (IMR) algorithms. Brain MRI was considered as the reference. Two blinded independent readers analysed the images. RESULTS: Ninety-three patients underwent all examinations. At the standard dose, eight patients presented 17 and 15 lesions on IMR and FBP CT images, respectively. At half-dose, seven patients presented 15 and 13 lesions on IMR and FBP CT images, respectively. The test could not highlight any significant difference between the standard dose IMR and the half-dose FBP techniques (p-value = 0.12). MRI showed 46 metastases on 11 patients. Specificity, negative and positive predictive values were calculated (98.9-100 %, 93.6-94.6 %, 75-100 %, respectively, for all CT techniques). CONCLUSION: No significant difference could be demonstrated between the two CT reconstruction techniques. KEY POINTS: • No significant difference between IMR100 and FBP50 was shown. • Compared to FBP, IMR increased the image quality without diagnostic impairment. • A 50 % dose reduction combined with IMR reconstructions could be achieved. • Brain MRI remains the best tool in lung cancer staging.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
6.
Ann Surg ; 266(5): 754-764, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28742686

RESUMO

OBJECTIVE: During the last decade, face allotransplantation has been shown to be a revolutionary reconstructive procedure for severe disfigurements. However, offer to patients remains limited due to lifelong immunosuppression. To move forward in the field, a new pathway in tissue engineering is proposed. BACKGROUND: Our previously reported technique of matrix production of a porcine auricular subunit graft has been translated to a human face model. METHODS: 5 partial and 1 total face grafts were procured from human fresh cadavers. After arterial cannulation, the specimens were perfused using a combined detergent/polar solvent decellularization protocol. Preservation of vascular patency was assessed by imaging, cell and antigen removal by DNA quantification and histology. The main extracellular matrix proteins and associated cytokines were evaluated. Lip scaffolds were cultivated with dermal, muscle progenitor and endothelial cells, either on discs or in a bioreactor. RESULTS: Decellularization was successful in all facial grafts within 12 days revealing acellular scaffolds with full preservation of innate morphology. Imaging demonstrated a preservation of the entire vascular tree patency. Removal of cells and antigens was confirmed by reduction of DNA and antigen markers negativation. Microscopic evaluation revealed preservation of tissue structures as well as of major proteins. Seeded cells were viable and well distributed within all scaffolds. CONCLUSIONS: Complex acellular facial scaffolds were obtained, preserving simultaneously a cell-friendly extracellular matrix and a perfusable vascular tree. This step will enable further engineering of postmortem facial grafts, thereby offering new perspectives in composite tissue allotransplantation.


Assuntos
Transplante de Face , Engenharia Tecidual/métodos , Biomarcadores/metabolismo , Reatores Biológicos , Citocinas/metabolismo , Matriz Extracelular/metabolismo , Humanos , Imuno-Histoquímica , Técnicas In Vitro , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Perfusão/métodos , Reperfusão/métodos , Alicerces Teciduais
7.
Eur Radiol ; 27(3): 927-937, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27300195

RESUMO

OBJECTIVES: To compare image quality [low contrast (LC) detectability, noise, contrast-to-noise (CNR) and spatial resolution (SR)] of MDCT images reconstructed with an iterative reconstruction (IR) algorithm and a filtered back projection (FBP) algorithm. METHODS: The experimental study was performed on a 256-slice MDCT. LC detectability, noise, CNR and SR were measured on a Catphan phantom scanned with decreasing doses (48.8 down to 0.7 mGy) and parameters typical of a chest CT examination. Images were reconstructed with FBP and a model-based IR algorithm. Additionally, human chest cadavers were scanned and reconstructed using the same technical parameters. Images were analyzed to illustrate the phantom results. RESULTS: LC detectability and noise were statistically significantly different between the techniques, supporting model-based IR algorithm (p < 0.0001). At low doses, the noise in FBP images only enabled SR measurements of high contrast objects. The superior CNR of model-based IR algorithm enabled lower dose measurements, which showed that SR was dose and contrast dependent. Cadaver images reconstructed with model-based IR illustrated that visibility and delineation of anatomical structure edges could be deteriorated at low doses. CONCLUSION: Model-based IR improved LC detectability and enabled dose reduction. At low dose, SR became dose and contrast dependent. KEY POINTS: • Model- based Iterative Reconstruction improves detectability of low contrast object. • With model- based Iterative Reconstruction, spatial resolution is dose and contrast dependent. • Model-based Iterative Reconstruction algorithms enable improved IQ combined with dose-reduction possibilities. • Improvement of SR and LC detectability on the same IMR data set would reduce reconstructions.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Algoritmos , Cadáver , Humanos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Tórax/diagnóstico por imagem
8.
COPD ; 12(1): 38-45, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24914492

RESUMO

UNLABELLED: Abstract Objective: To describe CT features associated with severe exacerbations of Chronic Obstructive Pulmonary Disease (COPD). MATERIALS AND METHODS: In this prospective ethical-committee-approved study, 44 COPD patients (34 men, 10 women, age range 49-83 years) who provided written informed consent were included at the time of hospital admission for severe exacerbation. Pulmonary function tests (PFT) and chest CT scans were performed at admission and after resolution of the episode following a minimum of 4 weeks free of any acute symptom. For each CT scan, two radiologists independently scored 15 features in each lobe and side. CT features and PFT results were compared for exacerbation and control through Mac-Nemar tests and paired t-tests, respectively. RESULTS: Forced expiratory volume in 1 second and vital capacity improved significantly after exacerbation (p = 0.023 and 0.012, respectively). Bronchial wall thickening and lymphadenopathy were graded significantly higher at exacerbation than at control by both readers (p ranging from < 0.001 to 0.028). Other CT features were not observed during exacerbation, or were so only by one reader (p ranging from < 0.001 to 0.928). CONCLUSION: Only lymphadenopathy and bronchial wall thickening are CT features associated with severe COPD exacerbation, respectively in 25% and 50% of patients. Our findings do not advocate a role for CT in the routine work-up of patients with severe COPD exacerbation.


Assuntos
Pulmão/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Índice de Gravidade de Doença , Método Simples-Cego , Capacidade Vital
9.
J Belg Soc Radiol ; 107(1): 91, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023295

RESUMO

Teaching Point: There are two important signs that could be seen on a non-contrast chest CT scan that can lead to the diagnosis of a pulmonary embolism: the hyperdense pulmonary artery sign and pulmonary infarction.

10.
Am J Kidney Dis ; 59(2): 258-69, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21944666

RESUMO

BACKGROUND: Vascular calcification independently predicts cardiovascular disease, the major cause of death in kidney transplant recipients (KTRs). Longitudinal studies of vascular calcification in KTRs are few and small and have short follow-up. We assessed the evolution of coronary artery (CAC) and thoracic aorta calcification and their determinants in a cohort of prevalent KTRs. STUDY DESIGN: Longitudinal. SETTING & PARTICIPANTS: The Agatston score of coronary arteries and thoracic aorta was measured by 16-slice spiral computed tomography in 281 KTRs. PREDICTORS: Demographic, clinical, and biochemical parameters were recorded simultaneously. OUTCOMES & MEASUREMENTS: The Agatston score was measured again 3.5 or more years later. RESULTS: Repeated analyzable computed tomographic scans were available for 197 (70%) KTRs after 4.40 ± 0.28 years; they were not available for the rest of patients because of death (n = 40), atrial fibrillation (n = 1), other arrhythmias (n = 4), refusal (n = 35), or technical problems precluding confident calcium scoring (n = 4). CAC and aorta calcification scores increased significantly (by a median of 11% and 4% per year, respectively) during follow-up. By multivariable linear regression, higher baseline CAC score, history of cardiovascular event, use of a statin, and lower 25-hydroxyvitamin D(3) level were independent determinants of CAC progression. Independent determinants of aorta calcification progression were higher baseline aorta calcification score, higher pulse pressure, use of a statin, older age, higher serum phosphate level, use of aspirin, and male sex. Significant regression of CAC or aorta calcification was not observed in this cohort. LIMITATIONS: Cohort of prevalent KTRs with potential survival bias; few patients with diabetes and nonwhites, limiting the generalizability of results. CONCLUSION: In contrast to previous small short-term studies, we show that vascular calcification progression is substantial within 4 years in prevalent KTRs and is associated with several traditional and nontraditional cardiovascular risk factors, some of which are modifiable.


Assuntos
Aorta Torácica/patologia , Doenças da Aorta/patologia , Calcinose/patologia , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Progressão da Doença , Transplante de Rim/patologia , Adulto , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Calcinose/complicações , Calcinose/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Transplante de Rim/diagnóstico por imagem , Transplante de Rim/mortalidade , Modelos Lineares , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida , Tomografia Computadorizada Espiral
11.
J Belg Soc Radiol ; 106(1): 34, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35600761

RESUMO

Teaching Point: Appendiceal intussusception appears as a "sausage or target shaped" lesion in the caecal lumen and may be caused by a "lead point".

12.
AJR Am J Roentgenol ; 196(1): 77-86, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21178050

RESUMO

OBJECTIVE: The right ventricle is often overlooked on chest and even cardiac MDCT studies. This article will review the normal anatomy of the right ventricle on MDCT and the signs of its functional alterations. CONCLUSION: MDCT signs of right ventricular dysfunction should be known and checked in relevant cases, such as pulmonary embolism in particular, and in any disease that affects both the structure and function of the lungs in general.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia , Diagnóstico por Imagem , Eletrocardiografia , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador
13.
Eur J Radiol ; 142: 109832, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34246013

RESUMO

OBJECTIVES: Intramammary mass lesions are reportedly present in up to 5.8% of all contrast enhanced CT-examinations of the female chest. We aimed to assess whether their biological relevance can be estimated using spectral CT-datasets. METHODS: In this bicentric retrospective study patients with breast masses visualized on spectral CT-examinations from 07/2017 to 06/2019 were included. Lesions were characterized as malignant or benign based on histology and/or a stable follow-up of >2 years. Conventional CT-images, iodine density-maps, virtual monoenergetic-images (40 keV, 100 keV) and Zeffective-maps were evaluated by two independent readers. Statistical analysis derived from the Regions of interest (ROIs) was done by calculating the Areas under the Receiver operating characteristic (ROC) curve (AUC) and Youden-indices. RESULTS: 106 breast masses (malignant/benign: 81/25, 76.4%/23.6%) were included. The mean AUCs of the variables "iodine content" (reader 1/2:0.97;0.98), "monoenergetic curve-slope" (0.97;0.96) and "Zeffective" (0.98;0.98) measured in the target lesions (TL) showed superior results compared to those derived from the variable "density" (0.92;0.93) (p < 0.001). The ratios "TL to aorta" calculated for the variables "iodine content", "monoenergetic curve-slope" and "Zeffective" showed superior results compared to normal breast tissue and muscle (p < 0.001). The optimal cutpoint for the "iodine content" in the TL was 0.7-0.9 mg/ml (sensitivity 96.6%, specificity 91.7%). The best diagnostic results were achieved by normalizing the iodine content in the TL to that in the aorta (optimal cutpoint 0.1, sensitivity 95.5%, 98.9%, specificity 91.7%). CONCLUSIONS: Our preliminary results suggest that spectral CT-datasets might allow to estimate the biological dignity of breast masses detected on clinically indicated chest-examinations.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Meios de Contraste , Feminino , Humanos , Curva ROC , Estudos Retrospectivos
14.
Respir Med ; 181: 106383, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33839588

RESUMO

BACKGROUND: COVID-19 pandemic resulted in an unprecedented number of hospitalizations in general wards and intensive care units (ICU). Severe and critical COVID-19 patients suffer from extensive pneumonia; therefore, long-term respiratory sequelae may be expected. RESEARCH QUESTION: We conducted a cohort study to determine respiratory sequelae in patients with severe and critical COVID-19. We aimed at evaluating the proportion of patients with persisting respiratory symptoms and/or abnormalities in pulmonary function tests (PFT) or in lung imaging. STUDY DESIGN: and methods: This is a single center cohort study including COVID-19 survivors who underwent a three-month follow-up with clinical evaluation, PFT and lung high-resolution computed tomography (HRCT). All clinical, functional, and radiological data were centrally reviewed. Multiple linear regression analysis was performed to identify factors associated with residual lesions on HRCT. RESULTS: Full clinical evaluation, PFT and lung HRCT were available for central review in 126, 122 and 107 patients, respectively. At follow-up, 25% of patients complained from dyspnea and 35% from fatigue, lung diffusion capacity (DLCO) was decreased in 45%, 17% had HRCT abnormalities affecting more than 5% of their lung parenchyma while signs of fibrosis were found in 21%. In multiple linear regression model, number of days in ICU were related to the extent of persisting lesions on HRCT, while intubation was associated with signs of fibrosis at follow-up (P = 0.0005, Fisher's exact test). In contrast, the severity of lung imaging or PFT changes were not predictive of fatigue and dyspnea. INTERPRETATION: Although most hospitalized COVID-19 patients recover, a substantial proportion complains from persisting dyspnea and fatigue. Impairment of DLCO and signs suggestive of fibrosis are common but are not strictly related to long-lasting symptoms.


Assuntos
COVID-19/diagnóstico por imagem , COVID-19/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Idoso , COVID-19/complicações , Estudos de Coortes , Dispneia/etiologia , Fadiga/etiologia , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Intensificação de Imagem Radiográfica , Testes de Função Respiratória , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
15.
Radiology ; 255(2): 377-85, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20019133

RESUMO

PURPOSE: To prospectively determine whether cardiac-gated multidetector computed tomography (CT) allows visualization of aortic valve leaflets after bioprosthetic aortic valve replacement (AVR), to provide an accurate method for measuring the aortic valve opening, and to provide morphologic and functional information regarding the mechanism underlying poor function of the bioprosthetic valve. MATERIALS AND METHODS: The institutional review board approved the study protocol; informed consent was given. Fifty-four patients (27 men; mean age, 75 years + or - 8 [standard deviation]) with bioprosthetic AVR implanted 2 years + or - 3 earlier underwent 64-section CT and transthoracic echocardiography (TTE). Two blinded observers manually planimetered the aortic valve area (AVA) by using a computer workstation on end-systolic short-axis CT images and measured opening angles (OAs) between the bioprosthesis annulus base and the free margin on long-axis images. These measurements were compared with those of the effective orifice area (EOA) of the valve at Doppler continuity-equation TTE by using regression and Bland-Altman methods. Morphology and mobility of leaflets in normally functioning (EOA indexed to body surface area [EOA(i)] > 0.65 cm(2)/m(2)) and dysfunctional (EOA(i)< 0.65 cm(2)/m(2)) AVRs were compared. RESULTS: AVA at CT correlated highly to EOA at TTE (r = 0.93, P < .001) but was significantly larger (1.2 cm(2) + or - 0.4 vs 1.1 cm(2) + or - 0.3, P < .001) than EOA at TTE. In dysfunctional bioprostheses (n = 34), CT results showed a variety of morphologic abnormalities, such as leaflet thickening (n = 9), presumed thrombotic material (n = 6), and leaflet calcification (n = 1). Multidetector CT results demonstrated restriction of leaflet motion indicated by lower OA (64 degrees + or - 5 vs 79 degrees + or - 3, P < .0001) in dysfunctional AVRs than in normally functioning AVRs (n = 11). CONCLUSION: Sixty-four-section CT can help accurately measure AVA in bioprosthetic AVR compared with EOA at TTE. It can also show morphologic abnormalities and reduced leaflet motion in a dysfunctional bioprosthesis, thereby potentially unraveling the mechanism of dysfunction.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anatomia & histologia , Bioprótese , Ecocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
16.
Nephrol Dial Transplant ; 25(11): 3773-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20501456

RESUMO

BACKGROUND: Coronary artery calcification (CAC) independently predicts cardiovascular events (CVE) in the general population. Whether this applies to renal transplant recipients (RTR) is unknown. This prospective study assessed the prognostic impact of CAC on CVE in RTR. METHODS: We followed up a published cohort of 281 prevalent RTR. At baseline, 16-slice chest spiral computerized tomography scan was performed and classical as well as CKD-related risk factors were recorded. Major CVE (MCVE) was defined as cardiovascular death, myocardial infarction, stroke or transient ischaemic attack. All CVE (ACVE) included MCVE and revascularizations. Prognostic factors were assessed by univariate and multivariate Cox regression. RESULTS: During 2.3 ± 0.5 years of follow-up, 16 patients died from CV (n = 8) or non-CV causes (n = 8). Thirty-one RTR developed at least one CVE (first CVE cardiac in 15, peripheral in 12 and cerebrovascular in 4) for a total of 36 CVE. Thirty-month CV survival, MCVE-free survival and ACVE-free survival was 96.4, 93.9 and 87.9%, respectively. By multivariate analysis, the independent predictors of ACVE were CAC score (hazards ratios [HR] = 1.40 [1.12; 1.75] for a 2.72-fold increase in CAC, P < 0.003) and history of CVE (HR = 2.76 [1.21; 6.39], P < 0.02). CONCLUSION: Our study shows for the first time that CAC is a strong independent predictor of CVE in RTR.


Assuntos
Calcinose/mortalidade , Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/mortalidade , Transplante de Rim , Adulto , Idoso , Doenças Cardiovasculares/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Prospectivos
17.
Future Oncol ; 6(3): 367-80, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20222794

RESUMO

Lung cancer is a major problem in public health and constitutes the leading cause of cancer-related mortality in the world. Lung cancer screening with low-dose computed tomography is promising but needs to overcome many difficulties, such as the large number of incidentally discovered nodules, the radiation dose delivered to the patient during a whole screening program and its cost. The ultimate target point represented by the reduction of lung cancer-related mortality needs to be proved in large, well-designed, randomized, multicenter, prospective trials. Lung cancer staging by morphological tools seems to be limited owing to the presence of metastases in normal-sized lymph nodes. In this context, multidetector computed tomography cannot be used alone but is useful in conjunction with molecular imaging and MRI. Today, flurodeoxglucose PET-CT appears to be the most accurate method for lung cancer staging and may prevent unnecessary thoracotomies. For treatment planning, flurodeoxglucose PET-CT is playing an increasing role in radiotherapy planning at the target selection and definition steps.


Assuntos
Diagnóstico por Imagem/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/terapia , Programas de Rastreamento/métodos , Adulto , Idoso , Feminino , Humanos , Masculino
18.
J Belg Soc Radiol ; 104(1): 52, 2020 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-32984759

RESUMO

Teaching point: Intra-osseous access for contrast medium injection represents an alternative route for emergency CT in patients with compromised venous access.

19.
Insights Imaging ; 11(1): 8, 2020 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-31974813

RESUMO

AIM: We hypothesized that multiple-choice questions written by radiology residents (MCQresident) for their weekly case presentations during radiology staff meetings could be used along with multiple-choice questions written by radiology teachers (MCQteacher) for their annual evaluation. The current prospective study aimed at determining the educational characteristics of MCQresident and at comparing them with those of MCQteacher. METHODS: Fifty-one radiology residents of the first to the fifth year of training took the 2017 exam that contained 58 MCQresident and 63 of MCQteacher. The difficulty index, the discrimination power, and the distractor's quality were calculated in the two series of MCQs and were compared by using Student t test. Two radiologists classified each MCQ according to Bloom's taxonomy and frequencies of required skills of both MCQ series were compared. RESULTS: The mean ± SD difficulty index of MCQresident was statistically significantly higher than that of MCQteacher (0.81 ± 0.1 vs 0.64 ± 0.2; p < 0.0001). The mean ± SD discrimination index of MCQresident was statistically significantly higher than that of MCQteacher (0.34 ± 0.2 vs 0.23 ± 0.2; p = 0.0007). The mean number of non-functional distractors per MCQresident was statistically significantly higher than that per MCQteacher (1.36 ± 0.9 vs 0.86 ± 0.9; p = 0.0031). MCQresident required recalling skills more frequently than MCQteacher which required more advanced skills to obtain a correct answer. CONCLUSIONS: Educational characteristics of MCQresident differ from those of MCQteacher. This study highlights the characteristics to optimize the writing of MCQs by radiology residents.

20.
Eur J Nucl Med Mol Imaging ; 36(3): 505-21, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19172269

RESUMO

PURPOSE: The last decade has seen a changing pattern of utilization of multidetector CT (MDCT) versus lung perfusion scintigraphy in the investigation of pulmonary venous thromboembolism (VTE). In response to this the International Atomic Energy Agency (IAEA) determined that the subject required an overview. METHOD: The IAEA has invited a group of five specialists in the relevant fields to review the current status and optimum role of scintigraphy, to explore some of the facts and controversies surrounding the use of both modalities and to make recommendations about the continued role of nuclear medicine for the investigation of pulmonary embolism. This paper identifies the relative merits of each technique, highlights benefits, focuses on complementary roles and seeks a nonadversarial symbiosis. CONCLUSION: The consultants reached a consensus that the continued use of scintigraphy for diagnosis of thromboembolic disease is recommended, particularly in scenarios where scintigraphy confers specific benefits and is complementary to MDCT.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia/métodos , Meios de Contraste/efeitos adversos , Prova Pericial , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Gravidez , Complicações na Gravidez/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Insuficiência Renal/complicações , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/tendências
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa