Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Molecules ; 28(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36985827

RESUMO

In the quest to market increasingly safer and more potent biotherapeutic proteins, the concept of the multi-attribute method (MAM) has emerged from biopharmaceutical companies to boost the quality-by-design process development. MAM strategies rely on state-of-the-art analytical workflows based on liquid chromatography coupled to mass spectrometry (LC-MS) to identify and quantify a selected series of critical quality attributes (CQA) in a single assay. Here, we aimed at evaluating the repeatability and robustness of a benchtop LC-MS platform along with bioinformatics data treatment pipelines for peptide mapping-based MAM studies using standardized LC-MS methods, with the objective to benchmark MAM methods across laboratories, taking nivolumab as a case study. Our results evidence strong interlaboratory consistency across LC-MS platforms for all CQAs (i.e., deamidation, oxidation, lysine clipping and glycosylation). In addition, our work uniquely highlights the crucial role of bioinformatics postprocessing in MAM studies, especially for low-abundant species quantification. Altogether, we believe that MAM has fostered the development of routine, robust, easy-to-use LC-MS platforms for high-throughput determination of major CQAs in a regulated environment.


Assuntos
Anticorpos Monoclonais , Anticorpos Monoclonais/química , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Glicosilação , Mapeamento de Peptídeos/métodos
2.
Anal Chem ; 92(13): 8827-8835, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32453570

RESUMO

Most of the current FDA and EMA approved therapeutic monoclonal antibodies (mAbs) are based on humanized or human IgG1, 2, or 4 subclasses and engineered variants. On the structural side, these subclasses are characterized by specific interchain disulfide bridge connections. Different analytical techniques have been reported to assess intact IgGs subclasses, with recently special interest in native ion mobility (IM) and collision induced unfolding (CIU) mass spectrometry (MS). However, these two techniques exhibit significant limitations to differentiate mAb subclasses at the intact level. In the present work, we aimed at developing a unique IM-MS-based approach for the characterization of mAb subclasses at the middle level. Upon IdeS-digestion, the unfolding patterns of the F(ab')2 and Fc domains were simultaneously analyzed in a single run to provide deeper structural insights of the mAb scaffold. The unfolding patterns associated with the F(ab')2 domains are completely different in terms of unfolding energies and number of transitions. Thereby, F(ab')2 regions are the diagnostic domain to provide specific unfolding signatures to differentiate IgG subclasses and provide more confident subclass categorization than CIU on intact mAbs. In addition, the potential of middle-level CIU was evaluated through the characterization of eculizumab, a hybrid therapeutic IgG2/4 mAb. The unfolding signatures of both domains were allowed to corroborate, within a single run, the hybrid nature of eculizumab as well as specific subclass domain assignments to the F(ab')2 and Fc regions. Altogether, our results confirm the suitability of middle-level CIU of F(ab')2 domains for subclass categorization of canonical and more complex new generation engineered antibodies and related products.


Assuntos
Anticorpos Monoclonais/análise , Imunoglobulina G/análise , Espectrometria de Massas/métodos , Adalimumab/análise , Adalimumab/química , Adalimumab/classificação , Anticorpos Monoclonais/química , Anticorpos Monoclonais/classificação , Anticorpos Monoclonais Humanizados/análise , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/classificação , Cromatografia Líquida de Alta Pressão , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fc das Imunoglobulinas/química , Imunoglobulina G/química , Imunoglobulina G/classificação , Espectrometria de Mobilidade Iônica , Desdobramento de Proteína
3.
Anal Chem ; 90(3): 1578-1586, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29260862

RESUMO

There are currently two main techniques allowing the analytical characterization of interchain cysteine-linked antibody drug conjugates (ADCs) under native conditions, namely, hydrophobic interaction chromatography (HIC) and native mass spectrometry (MS). HIC is a chromatographic technique allowing the evaluation of drug load profile and calculation of average drug-to-antibody ratio (DAR) in quality control laboratories. Native MS offers structural insights into multiple ADC critical quality attributes, thanks to accurate mass measurement. However, both techniques can lead to misinterpretations or incomplete characterization when used as standalone methods. Online coupling of both techniques can thus potentially be of great interest, but the presence of large amounts of nonvolatile salts in HIC mobile phases makes it not easily directly compatible with native MS. Here, we present an innovative multidimensional analytical approach combining comprehensive online two-dimensional (2D)-chromatography that consists of HIC and size-exclusion chromatography (SEC), to ion mobility and mass spectrometry (IM-MS) for performing analytical characterization of ADCs under nondenaturing conditions. This setup enabled comprehensive and streamlined characterization of both native and forced degraded ADC samples. The proposed 4D methodology might be more generally adapted for online all-in-one HIC×SEC-IM×MS analysis of single proteins or analysis of protein complexes in nondenaturing conditions.


Assuntos
Cromatografia em Gel , Imunoconjugados/química , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas
4.
Electrophoresis ; 39(16): 2083-2090, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29774560

RESUMO

The determination of mAb critical quality attributes (CQA) is crucial for their successful application in health diseases. A generic CZE method was developed for the high-resolution separation of various mAb charge variants, which are often recognized as important CQA. A dynamic coating of the capillary was obtained with polyethylene oxide (PEO), whereas Bis-Tris allowed the analysis of mAbs under native conditions at pH 7.0. The effect of PEO and Bis-Tris concentrations, as well as the nature of the acidic counter ion on the method performance was systematically studied. The %RSD on migration times was below 5% on three different CE instruments using the optimized method. Additional charge variants (in particular acidic variants) were resolved for 10 out of 17 mAbs compared to a reference CZE approach involving the use of ε-amino-caproic acid (EACA), triethylenetetramine (TETA), and hydroxypropylmethyl cellulose (HPMC). The amount of basic and acidic charge variants of 17 Food and Drug Administration (FDA) approved mAbs covering a wide range of physico-chemical properties, e.g., pI between 8.0 and 9.4 and different hydrophobicity, were mainly comprised between 5-15% and 15-30%, respectively. It is noteworthy that applications for the quality control in hospitals as well as for the combination of the immune checkpoint inhibitors nivolumab and ipilimumab were presented.


Assuntos
Anticorpos Monoclonais/isolamento & purificação , Eletroforese Capilar/métodos , Antineoplásicos Imunológicos , Eletroforese Capilar/instrumentação , Concentração de Íons de Hidrogênio , Ipilimumab/análise , Ipilimumab/isolamento & purificação , Nivolumabe/análise , Nivolumabe/isolamento & purificação , Polietilenoglicóis , Controle de Qualidade
5.
Expert Rev Proteomics ; 13(2): 157-83, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26653789

RESUMO

Antibody drug conjugates (ADCs) are highly cytotoxic drugs covalently attached via conditionally stable linkers to monoclonal antibodies (mAbs) and are among the most promising next-generation empowered biologics for cancer treatment. ADCs are more complex than naked mAbs, as the heterogeneity of the conjugates adds to the inherent microvariability of the biomolecules. The development and optimization of ADCs rely on improving their analytical and bioanalytical characterization by assessing several critical quality attributes, namely the distribution and position of the drug, the amount of naked antibody, the average drug to antibody ratio, and the residual drug-linker and related product proportions. Here brentuximab vedotin (Adcetris) and trastuzumab emtansine (Kadcyla), the first and gold-standard hinge-cysteine and lysine drug conjugates, respectively, were chosen to develop new mass spectrometry (MS) methods and to improve multiple-level structural assessment protocols.


Assuntos
Imunoconjugados/química , Espectrometria de Massas/métodos , Anticorpos Monoclonais/imunologia
6.
Anal Chem ; 87(7): 3784-90, 2015 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-25769014

RESUMO

The bioproduction of recombinant monoclonal antibodies results in complex mixtures of a main isoform and numerous macro- and microvariants. Monoclonal antibodies therefore present different levels of heterogeneities ranging from primary sequence variants to post-translational modifications. Among these heterogeneities, the truncation and fragmentation of the primary amino-acid sequence result in shorter or cleaved polypeptide chains while the incomplete processing of the signal peptide produces N-terminal elongated polypeptide chains. Here, we present an in-gel protein N-terminal chemical derivatization method using (N-succinimidyloxycarbonylmethyl)-tris(2,4,6-trimethoxyphenyl)phosphonium bromide (TMPP). This chemical tag enhances the detection by mass spectrometry of the N-terminal positions of proteins and allows their unambiguous assignment without altering the identification of internal digestion peptides. This method adds just one step to the classical peptide mapping workflow. Using this in-gel N-TOP (N-terminal oriented proteomics) strategy, the N-terminal sequence heterogeneities of several monoclonal antibodies, among which are minor unexpected proteoforms, were successfully detected and characterized.


Assuntos
Amidas/química , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Géis/química , Linhagem Celular , Cromatografia Líquida , Humanos , Espectrometria de Massas em Tandem
7.
Anal Chem ; 86(21): 10674-83, 2014 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-25270580

RESUMO

Antibody drug conjugates (ADCs) are macromolecules composed of cytotoxic drugs covalently attached via a conditionally stable linker to monoclonal antibodies (mAbs). ADCs are among the most promising next generation of empowered mAbs foreseen to treat cancers. Compared to naked mAbs, ADCs have an increased level of complexity as the heterogeneity of conjugation cumulates with the inherent microvariability of the biomolecule. An increasing need underlying ADC's development and optimization is to improve its analytical and bioanalytical characterization by assessing three main ADC quality attributes: drug distribution, amount of naked antibody, and average drug to antibody ratio (DAR). Here, the analytical potential of native mass spectrometry (MS) and native ion mobility MS (IM-MS) is compared to hydrophobic interaction chromatography (HIC), the reference method for quality control of interchain cysteinyl-linked ADCs. Brentuximab vedotin, first in class and gold standard, was chosen for a proof of principle. High resolution native MS provided accurate mass measurement (<30 ppm) of intact ADCs together with average DAR and drug distribution, confirming the unique ability of native MS for simultaneous detection of mixtures of covalent and noncovalent products. Native IM-MS was next used for the first time to characterize an ADC. IM-MS evidenced ADC multiple drug loading, collisional cross sections measurement of each payload species attesting slight conformational changes. A semiquantitative interpretation of IM-MS data was developed to directly extrapolate average DAR and DAR distribution. Additionally, HIC fractions were collected and analyzed by native MS and IM-MS, assessing the interpretation of each HIC peak. Altogether, our results illustrate how native MS and IM-MS can rapidly assess ADC structural heterogeneity and how easily these methods can be implemented into MS workflows for in-depth ADC analytical characterization.


Assuntos
Imunoconjugados/química , Espectrometria de Massas , Brentuximab Vedotin , Cromatografia Líquida/métodos , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas/métodos
8.
Anal Chem ; 85(20): 9785-92, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24007193

RESUMO

Monoclonal antibodies (mAbs) and derivatives such as antibody-drug conjugates (ADC) and bispecific antibodies (bsAb), are the fastest growing class of human therapeutics. Most of the therapeutic antibodies currently on the market and in clinical trials are chimeric, humanized, and human immunoglobulin G1 (IgG1). An increasing number of IgG2s and IgG4s that have distinct structural and functional properties are also investigated to develop products that lack or have diminished antibody effector functions compared to IgG1. Importantly, wild type IgG4 has been shown to form half molecules (one heavy chain and one light chain) that lack interheavy chain disulfide bonds and form intrachain disulfide bonds. Moreover, IgG4 undergoes a process of Fab-arm exchange (FAE) in which the heavy chains of antibodies of different specificities can dissociate and recombine in bispecific antibodies both in vitro and in vivo. Here, native mass spectrometry (MS) and time-resolved traveling wave ion mobility MS (TWIM-MS) were used for the first time for online monitoring of FAE and bsAb formation using Hz6F4-2v3 and natalizumab, two humanized IgG4s which bind to human Junctional Adhesion Molecule-A (JAM-A) and alpha4 integrin, respectively. In addition, native MS analysis of bsAb/JAM-A immune complexes revealed that bsAb can bind up to two antigen molecules, confirming that the Hz6F4 family preferentially binds dimeric JAM-A. Our results illustrate how IM-MS can rapidly assess bsAb structural heterogeneity and be easily implemented into MS workflows for bsAb production follow up and bsAb/antigen complex characterization. Altogether, these results provide new MS-based methodologies for in-depth FAE and bsAb formation monitoring. Native MS and IM-MS will play an increasing role in next generation biopharmaceutical product characterization like bsAbs, antibody mixtures, and antibody-drug conjugates (ADC) as well as for biosimilar and biobetter antibodies.


Assuntos
Anticorpos Biespecíficos/biossíntese , Anticorpos Biespecíficos/imunologia , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/imunologia , Fragmentos Fab das Imunoglobulinas/imunologia , Imunoglobulina G/imunologia , Espectrometria de Massas/métodos , Anticorpos Monoclonais Humanizados/imunologia , Humanos , Natalizumab , Fatores de Tempo
9.
Methods Mol Biol ; 2313: 207-217, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34478140

RESUMO

Biopharmaceutical sequences can be well confirmed by multiple protease digests-e.g., trypsin, elastase, and chymotrypsin-followed by LC-MS/MS data analysis. High quality data can be used for de novo sequencing as well. PASEF (Parallel Accumulation and Serial Fragmentation) on the timsTOF instrument has been used to accelerate proteome and protein sequence studies and increase sequence coverage concomitantly.Here we describe the protein chemical and LC-MS methods in detail to generate high quality samples for sequence characterization from only 3 digests. We applied PASEF to generate exhaustive protein sequence coverage maps by combination of results from the three enzyme digests using a short LC gradient. The data quality obtained was high and adequate for determining antibody sequences de novo.Nivolumab and dulaglutide were digested by 3 enzymes individually. For nivolumab, 94/94/90% sequence coverage and 86/84/85% fragment coverage were obtained from the individual digest analysis with trypsin/chymotrypsin/elastase, respectively. For dulaglutide, 96/100/90% sequence coverage and 92/90/83% fragment coverage were obtained. The merged peptide map from the 3 digests for nivolumab resulted in ∼550 peptides; enough to safely confirm the full sequences and to determine the nivolumab sequence de novo.


Assuntos
Confiabilidade dos Dados , Cromatografia Líquida , Quimotripsina , Nivolumabe , Elastase Pancreática , Peptídeos , Proteoma , Análise de Sequência de Proteína , Espectrometria de Massas em Tandem , Tripsina
10.
Anal Chim Acta ; 1156: 338347, 2021 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-33781463

RESUMO

When analyzing large complex protein biopharmaceuticals, ion-pairing agents imparting low pH are widely used as mobile phase additives to improve the chromatographic performance. However, one of the most effective additives in RPLC and HILIC, trifluoroacetic acid (TFA), is known as a strong suppressor of the MS signal and limits its use in hyphenated techniques. In this study, we evaluated a wide range of acidic additives to find alternatives to TFA that provided comparable chromatographic performance and improved MS sensitivity. It was observed that stronger acidic additives were required for intact level analysis compared to subunit level analysis and that the additive nature had a larger impact on the chromatographic performance in HILIC mode compared to RPLC. Therefore, four additives were identified as valuable alternatives to TFA in RPLC mode, namely, difluoroacetic acid (DFA), dichloroacetic acid (DClAA), trichloroacetic acid (TClAA), and methanesulfonic acid (MSA). Only one of these additives provided acceptable performance in HILIC mode, namely, TClAA. After evaluation of the MS performance, TClAA was discarded due to the apparent loss of intensity in both RPLC-MS and HILIC-MS mode. Together, these results demonstrate that for HILIC-MS analysis TFA remains the gold standard additive. However, DFA was found as promising alternative to TFA for RPLC-MS analysis and could play an important role in the development of methods for the characterization of the increasingly complex protein biopharmaceuticals.


Assuntos
Produtos Biológicos , Cromatografia Líquida , Cromatografia de Fase Reversa , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas , Proteínas , Ácido Trifluoracético
11.
Methods Mol Biol ; 2271: 73-83, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33908000

RESUMO

Middle-up LC-MS antibody characterization workflows using reduction or IdeS digestion for a focused assessment of N-glycan profiling of three representative glycoengineered monoclonal antibodies (mAbs), namely, obinutuzumab (GlycomAb technology, Glycart/Roche), benralizumab (Potelligent Technology, BioWa, Kyowa Kirin) and mAb B (kifunensine) and compared to mAb A, produced in a common CHO cell line. In addition, EndoS or EndoS2 enzyme are used for quantitative determination of Fc-glycan core afucosylation and high mannose for these antibodies, as requested by health authorities for Fc-competent therapeutics mAbs critical quality attributes (CQAs).


Assuntos
Alcaloides/análise , Anticorpos Monoclonais Humanizados/análise , Engenharia de Proteínas , Processamento de Proteína Pós-Traducional , Espectrometria de Massas por Ionização por Electrospray , Alcaloides/uso terapêutico , Animais , Anticorpos Monoclonais Humanizados/uso terapêutico , Células CHO , Cromatografia Líquida , Cricetulus , Glicosilação , Projetos de Pesquisa , Fluxo de Trabalho
12.
J Am Soc Mass Spectrom ; 32(10): 2505-2512, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34437803

RESUMO

Monoclonal antibodies (mAbs) have taken on an increasing importance for the treatment of various diseases, including cancers and immunological disorders. Disulfide bonds play a pivotal role in therapeutic antibody structure and activity relationships. Disulfide connectivity and cysteine-related variants are considered as critical quality attributes that must be monitored during mAb manufacturing and storage, as non-native disulfide bridges and aggregates might be responsible for loss of biological function and immunogenicity. The presence of cysteine residues in the complementarity-determining regions (CDRs) is rare in human antibodies but may be critical for the antigen-binding or deleterious for therapeutic antibody development. Consequently, in-depth characterization of their disulfide network is a prerequisite for mAb developability assessment. Mass spectrometry (MS) techniques represent powerful tools for accurate identification of disulfide connectivity. We report here on the MS-based characterization of an IgG4 comprising two additional cysteine residues in the CDR of its light chain. Classical bottom-up approaches after trypsin digestion first allowed identification of a dipeptide containing two disulfide bridges. To further investigate the conformational heterogeneity of the disulfide-bridged dipeptide, we performed ion mobility spectrometry-mass spectrometry (IMS-MS) experiments. Our results highlight benefits of high resolution IMS-MS to tackle the conformational landscape of disulfide peptides generated after trypsin digestion of a humanized IgG4 mAb under development. By comparing arrival time distributions of the mAb-collected and synthetic peptides, cyclic IMS afforded unambiguous assessment of disulfide bonds. In addition to classical peptide mapping, qualitative high-resolution IMS-MS can be of great interest to identify disulfide bonds within therapeutic mAbs.


Assuntos
Anticorpos Monoclonais/química , Regiões Determinantes de Complementaridade/química , Dissulfetos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Dissulfetos/análise , Dissulfetos/química , Humanos , Imunoglobulina G/química
13.
Methods Mol Biol ; 2078: 187-195, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31643057

RESUMO

High-resolution native mass spectrometry (MS) provides accurate mass measurements (within 30 ppm) of intact ADCs and can also yield drug load distribution (DLD) and average drug to antibody ratio (DAR) in parallel with hydrophobic interaction chromatography (HIC). Native MS is furthermore unique in its ability to simultaneously detect covalent and noncovalent species in a mixture and for HIC peak identity assessment offline or online.As an orthogonal method described in this chapter, LC-MS following ADC reduction or IdeS (Fabricator) digestion and reduction can also be used to measure the DLD of light chain and Fd fragments for hinge native cysteine residues such as brentuximab vedotin. Both methods allow also the measurement of average DAR for both monomeric and multimeric species. In addition, the Fc fragments can be analyzed in the same run, providing a complete glycoprofile and the demonstration or absence of additional conjugation of this subdomain involved in FcRn and Fc-gammaR binding.


Assuntos
Anticorpos Monoclonais/química , Imunoconjugados/química , Imunoconjugados/farmacologia , Preparações Farmacêuticas/química , Cromatografia Líquida de Alta Pressão , Cisteína/química , Cisteína Endopeptidases/química , Humanos , Espectrometria de Massas
14.
J Pharm Biomed Anal ; 184: 113166, 2020 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-32113118

RESUMO

In the present work, a generic non-reducing capillary electrophoresis sodium dodecyl sulphate (nrCE-SDS) method was tested for a wide range of 26 FDA and EMA approved monoclonal antibodies (mAbs) and 2 antibody drug conjugates (ADCs) as well as for the NISTmab, in a QC environment (e.g. testing quality requirements for batch manufacturing or batch release). This method allows obtaining rapidly and accurately the amount of size variants in drug products within about 40 min and may be used for batch release and consistency as well as for stability and shelf-life. First, the method repeatability was found to be excellent in terms of relative migration times and relative proportions of fragments (average RSD values of 0.3 and 0.2 %, on relative migration times and relative percentages of fragments, respectively), thanks to the addition of an internal standard. A panel of chimeric, humanized and human mAbs were tested, belonging to different subclasses (heavy chain gamma 1, 2, 2/4 and 4) and light chain types (κ or λ) and produced in different cell lines (CHO, NS0 and SP2/0). For all these biopharmaceutical products, the amount of H2L2 species was comprised between 90.9 % and 97.7 %, except for the two mAbs belonging to the IgG1λ subclass, namely avelumab and belimumab, which were prone to partial reduction during the sample preparation at 70 °C. Based on the CE-SDS results obtained for a diverse panel of therapeutic antibodies investigated in this study, and covering a wide range of structural and physico-chemical properties, a specification on the intact antibody content (H2L2) greater than 90 % can be achieved.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/uso terapêutico , Eletroforese Capilar/métodos , Imunoconjugados/uso terapêutico , Cadeias Leves de Imunoglobulina/metabolismo , Dodecilsulfato de Sódio/química , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/uso terapêutico , Antineoplásicos Imunológicos/química , Antineoplásicos Imunológicos/uso terapêutico , Humanos , Imunoconjugados/química , Cadeias Leves de Imunoglobulina/química
15.
J Chromatogr B Analyt Technol Biomed Life Sci ; 872(1-2): 23-37, 2008 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-18672411

RESUMO

Glycosylation which plays a crucial role in the pharmacological properties of therapeutic monoclonal antibodies (MAbs) is influenced by several factors like production systems, selected clonal population and manufacturing processes. Efficient analytical methods are therefore required in order to characterize glycosylation at different stages of MAbs discovery and production. Three mass spectrometry (MS)-based strategies were compared to analyze N-glycosylation of MAbs either expressed in murine myeloma (NS0) or Chinese Hamster Ovary (CHO) cell lines, the two current main production systems used for therapeutic MAbs. First a top-down approach was used on intact and reduced MAbs by liquid chromatography coupled to an electrospray ionization-time of flight mass spectrometer (LC-ESI-TOF), which provided fast and accurate profiles of MAbs glycosylation patterns for routine controls. Secondly, after digestion of the antibody with the peptide N-glycosidase F (PNGase F) enzyme, released N-linked glycans were directly analyzed by electrospray ionization-tandem mass spectrometry (ESI-MS/MS) without any prior derivatization, which gave precise details on the structure of the most abundant glycoforms. Finally, a bottom-up approach on tryptic glycopeptides using a nanoLC-Chip-MS/MS ion trap (IT) system equipped with a graphitized carbon column was investigated. Data were compared to those obtained with a more classical C18 reversed phase column showing that this last method is well suited to detect low abundant glycoforms and to provide in one shot information regarding both the oligosaccharide structure and the amino acid sequence of its peptide moiety.


Assuntos
Anticorpos Monoclonais/metabolismo , Espectrometria de Massas/métodos , Animais , Anticorpos Monoclonais/química , Células CHO , Cromatografia Líquida , Cricetinae , Cricetulus , Glicosilação , Mapeamento de Peptídeos
16.
Artigo em Inglês | MEDLINE | ID: mdl-29684909

RESUMO

Mass spectrometry performed in non-denaturing conditions (native MS), and its hyphenation to ion mobility spectrometry (IM-MS), have gained interest for the qualitative and quantitative characterization of intact monoclonal antibody-related (mAb) products. However, one main drawback is the manual sample preparation, which hampers its routine use in high throughput automated environments. Size exclusion chromatography (SEC) appears as an interesting technique to perform online buffer exchange in an automated way. We present here an exhaustive and systematic evaluation of the possibilities and versatility of SEC direct hyphenation to native MS or IM-MS (SEC-nativeMS/IM-MS) for the characterization of a variety of mAb-formats (IgGs, ADCs, bispecific mAbs and Fc-fusion proteins). First, online SEC-native MS allows automated sample preparation, resulting in high resolution mass spectra and improved mass accuracies (<80 ppm) compared to manual buffer exchange procedures. When hyphenated to ion mobility, SEC-native IM-MS can deliver conformational characterization through collision cross section (CCS) measurements within few minutes without affecting mAb structures. Finally, benefits of online SEC-nativeIM-MS compared to standalone SEC-UV or native MS techniques are demonstrated for higher order structure characterization of mAb forced degraded samples. While SEC provides separation of high/low molecular weight species from the main mAb peak along with precise quantification of the species, native MS affords complementary unambiguous identification of SEC peaks, even when poor SEC separation is achieved. The synergic online coupling of SEC to native MS/IM-MS is envisioned to definitely push native MS approaches at the forefront of mAb characterization in quality-controlled environments and as multiple monitoring method.


Assuntos
Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Cromatografia em Gel/métodos , Espectrometria de Massas/métodos , Agregados Proteicos
17.
Talanta ; 178: 530-537, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136858

RESUMO

Characterization of therapeutic proteins represents a major challenge for analytical sciences due to their heterogeneity caused by post-translational modifications (PTM). Among these PTM, glycosylation which is possibly the most prominent, require comprehensive identification because of their major influence on protein structure and effector functions of monoclonal antibodies (mAbs). As a consequence, glycosylation profiling must be deeply characterized. For this application, several analytical methods such as separation-based or MS-based methods, were evaluated. However, no CE-ESI-MS approach has been assessed and validated. Here, we illustrate how the use of CE-ESI-MS method permits the comprehensive characterization of mAbs N-glycosylation at the glycopeptide level to perform relative quantitation of N-glycan species. Validation of the CE-ESI-MS method in terms of robustness and reproducibility was demonstrated through the relative quantitation of glycosylation profiles for ten different mAbs produced in different cell lines. Glycosylation patterns obtained for each mAbs were compared to Hydrophilic Interaction Chromatography of 2-aminobenzamide labelled glycans with fluorescence detector (HILIC-FD) analysis considered as a reference method. Very similar glycoprofiling were obtained with the CE-ESI-MS and HILIC-FD demonstrating the attractiveness of CE-ESI-MS method to characterize and quantify the glycosylation heterogeneity of a wide range of therapeutic mAbs with high accuracy and precision.


Assuntos
Anticorpos Monoclonais/química , Glicopeptídeos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Cromatografia/métodos , Eletroforese Capilar/métodos , Glicosilação , Reprodutibilidade dos Testes
18.
J Chromatogr A ; 1498: 80-89, 2017 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-27914608

RESUMO

The aim of this study was to evaluate the practical possibilities and limitations of several recently introduced size exclusion chromatographic (SEC) columns of 150×4.6mm, sub-3µm (Agilent AdvanceBioSEC 2.7µm, Tosoh TSKgel UP-SW3000 2.0µm, Phenomenex Yarra SEC X-150 1.8µm and Waters Acquity BEH200 1.7µm) for the separation of biopharmaceutical proteins. For this purpose, some model proteins were tested, as well as several commercial therapeutic monoclonal antibodies (mAbs) and antibody-drug-conjugates (ADCs). Calibration curves were drawn to highlight the applicability of these new SEC columns for the separation of mAbs, ADCs and their aggregates, despite some differences in their nominal pore diameter (vary from 150 to 300Å). The kinetic performance (van Deemter curves and kinetic pots) was evaluated. Columns packed with 1.7-2.0µm particles improved the plate count by a factor of 1.5-2 compared to 2.7µm particles, which is in agreement with theoretical expectations. Finally, possible secondary hydrophobic and/or electrostatic interactions between the SEC stationary phases and biopharmaceutical proteins were systematically studied. Significant differences in nonspecific interactions were observed, with hydrophobic interactions generally exerting more influence than electrostatic interactions. The use of a novel bond chemistry with the AdvanceBioSEC column was found highly effective to limit non-specific interactions and pave the way to further improvements for column provider. At the end, the average resolutions achieved on the four sub-3µm SEC columns between monomer and dimer structures were comparable for ten approved mAbs products.


Assuntos
Biofarmácia/métodos , Cromatografia em Gel/normas , Proteínas/análise , Anticorpos Monoclonais/análise , Cinética , Tamanho da Partícula , Água/química
19.
Artigo em Inglês | MEDLINE | ID: mdl-28666223

RESUMO

The analytical characterization of therapeutic monoclonal antibodies and related proteins usually incorporates various sample preparation methodologies. Indeed, quantitative and qualitative information can be enhanced by simplifying the sample, thanks to the removal of sources of heterogeneity (e.g. N-glycans) and/or by decreasing the molecular size of the tested protein by enzymatic or chemical fragmentation. These approaches make the sample more suitable for chromatographic and mass spectrometric analysis. Structural elucidation and quality control (QC) analysis of biopharmaceutics are usually performed at intact, subunit and peptide levels. In this paper, general sample preparation approaches used to attain peptide, subunit and glycan level analysis are overviewed. Protocols are described to perform tryptic proteolysis, IdeS and papain digestion, reduction as well as deglycosylation by PNGase F and EndoS2 enzymes. Both historical and modern sample preparation methods were compared and evaluated using rituximab and trastuzumab, two reference therapeutic mAb products approved by Food and Drug Administration (FDA) and European Medicines Agency (EMA). The described protocols may help analysts to develop sample preparation methods in the field of therapeutic protein analysis.


Assuntos
Anticorpos Monoclonais/análise , Cromatografia Líquida de Alta Pressão/métodos , Papaína/farmacocinética , Fragmentos de Peptídeos/análise , Tripsina/metabolismo , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Glicosilação , Espectrometria de Massas , Papaína/metabolismo , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Polissacarídeos/análise , Polissacarídeos/química , Polissacarídeos/metabolismo
20.
J Chromatogr A ; 1498: 147-154, 2017 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-28400066

RESUMO

Chemical or enzymatic modifications of therapeutic monoclonal antibodies (mAbs) having high risk towards safety and efficacy are defined as critical quality attributes (CQAs). During therapeutic mAbs process development, a variety of analytical techniques have to be used for the thorough characterization and quantitative monitoring of CQAs. This paper describes the development of a rapid analytical platform to assess and rank charge variants of mAbs. The workflow is first based on a cation exchange chromatography (CEX) comparative analysis of intact IgGs versus F(ab)'2 and Fc sub-domains generated by IdeS digestion. This analytical procedure was validated with FDA and EMA approved mAbs. Then, functional assays and peptide mapping can be performed in a second instance. This approach can be used during the early stage of drug research and development to screen lead molecules and select optimized candidates (best clone, best formulation) which could be "easily" developed (OptimAbs).


Assuntos
Anticorpos Monoclonais/metabolismo , Peptídeos/análise , Adalimumab/metabolismo , Sequência de Aminoácidos , Proteínas de Bactérias/metabolismo , Bevacizumab/metabolismo , Cromatografia por Troca Iônica , Humanos , Fragmentos Fab das Imunoglobulinas/metabolismo , Fragmentos Fc das Imunoglobulinas/química , Fragmentos Fc das Imunoglobulinas/metabolismo , Mapeamento de Peptídeos , Peptídeos/isolamento & purificação , Rituximab/metabolismo , Alinhamento de Sequência
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa