Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Environ Sci Technol ; 53(17): 10110-10119, 2019 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-31390861

RESUMO

Streams in the northeastern U.S. receive mercury (Hg) in varying proportions from atmospheric deposition and legacy point sources, making it difficult to attribute shifts in fish concentrations directly back to changes in Hg source management. Mercury stable isotope tracers were utilized to relate sources of Hg to co-located fish and bed sediments from 23 streams across a forested to urban-industrial land-use gradient within this region. Mass-dependent isotopes (δ202Hg) in prey and game fish at forested sites were depleted (medians -0.95 and -0.83 ‰, respectively) in comparison to fish from urban-industrial settings (medians -0.26 and -0.38 ‰, respectively); the forested site group also had higher prey fish Hg concentrations. The separation of Hg isotope signatures in fish was strongly related to in-stream and watershed land-use indicator variables. Fish isotopes were strongly correlated with bed sediment isotopes, but the isotopic offset between the two matrices was variable due to differing ecosystem-specific drivers controlling the extent of MeHg formation. The multivariable approach of analyzing watershed characteristics and stream chemistry reveals that the Hg isotope composition in fish is linked to current and historic Hg sources in the northeastern U.S. and can be used to trace bioaccumulated Hg.


Assuntos
Mercúrio , Poluentes Químicos da Água , Animais , Ecossistema , Monitoramento Ambiental , Isótopos de Mercúrio , New England , Rios
2.
Small ; 9(7): 1058-65, 2013 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-23233398

RESUMO

The optical absorption efficiencies of vertically aligned multi-walled (MW)-carbon nanotube (CNT) ensembles are characterized in the 350-7000 nm wavelength range where CNT site densities > 1 × 10(11) /cm(2) are achieved directly on metallic substrates. The site density directly impacts the optical absorption characteristics, and while high-density arrays of CNTs on electrically insulating and non-metallic substrates have been commonly reported, achieving high site-densities on metals has been challenging and remains an area of active research. These absorber ensembles are ultra-thin (<10 µm) and yet they still exhibit a reflectance as low as ∼0.02%, which is 100 times lower than the reference; these characteristics make them potentially attractive for high-sensitivity and high-speed thermal detectors. In addition, the use of a plasma-enhanced chemical vapor deposition process for the synthesis of the absorbers increases the portfolio of materials that can be integrated with such absorbers due to the potential for reduced synthesis temperatures. The remarkable ruggedness of the absorbers is also demonstrated as they are exposed to high temperatures in an oxidizing ambient environment, making them well-suited for extreme thermal environments encountered in the field, potentially for solar cell applications. Finally, a phenomenological model enables the determinatiom of the extinction coefficients in these nanostructures and the results compare well with experiment.


Assuntos
Luz , Nanotecnologia/métodos , Nanotubos de Carbono/química , Microscopia de Força Atômica , Modelos Teóricos , Nanotubos de Carbono/ultraestrutura , Raios Ultravioleta
3.
Europace ; 15(11): 1622-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24014804

RESUMO

AIMS: Adaptive cardiac resynchronization therapy (aCRT) is a novel algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular (LV) or bi-ventricular (BiV) pacing and optimization of atrioventricular (AV) and inter-ventricular (VV) delays based on periodic measurement of intrinsic conduction. We aimed to compare the clinical response between aCRT and standard CRT in historical trials. METHODS AND RESULTS: The treatment arm of the aCRT trial was compared with a pooled historical control (HC) derived from the CRT arms of four clinical trials (MIRACLE, MIRACLE ICD, PROSPECT, and InSync III Marquis) with respect to the proportion of patients who had an improved clinical composite score (CCS) at the 6-month follow-up. Patients in the HC underwent echocardiography-guided AV optimization after the implant. A propensity score model was used to adjust for 22 potential baseline confounders of the effect of CRT. Patients were stratified into quintiles according to the propensity score and the adjusted absolute treatment effect was obtained by averaging estimates across these quintiles. The propensity score model included 751 patients (aCRT: 266, historical trials: 485). The adjusted absolute difference in percent improved in CCS between the aCRT and HC arms was 11.9% [95% confidence interval (CI): 2.7-19.2%] favouring aCRT. The patients in the aCRT group were significantly more likely to have an improved CCS than the patients in the HC (odds ratio = 1.65, 95% CI: 1.1-2.5). CONCLUSION: The aCRT algorithm may be associated with additional improvement in clinical response compared with historical CRT with echocardiographic AV optimization.


Assuntos
Nó Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca , Ecocardiografia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Algoritmos , Método Duplo-Cego , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 34(4): 443-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21208227

RESUMO

BACKGROUND: Echocardiographic optimization of the atrioventricular delay (AV) may result in improvement in cardiac resynchronization therapy (CRT) outcome. Optimal AV has been shown to correlate with interatrial conduction time (IACT) during right atrial pacing. This study aimed to prospectively validate the correlation at different paced heart rates and examine it during sinus rhythm (Sinus). METHODS: An electrophysiology catheter was placed in the coronary sinus (CS) during CRT implant (n = 33). IACT was measured during Sinus and atrial pacing at 5 beats per minute (bpm) and 20 bpm above the sinus rate as the interval from atrial sensing or pacing to the beginning of the left atrial activation in the CS electrogram. P-wave duration (PWd) was measured from 12-lead surface electrocardiogram, and the interval from the right atrial to intrinsic right ventricular activation (RA-RV) was measured from device electrograms. Within 3 weeks after the implant patients underwent echocardiographic optimization of the sensed and paced AVs by the mitral inflow method. RESULTS: Optimal sensed and paced AVs were 129 ± 19 ms and 175 ± 24 ms, respectively, and correlated with IACT during Sinus (R = 0.76, P < 0.0001) and atrial pacing (R = 0.75, P < 0.0001), respectively. They also moderately correlated with PWd (R = 0.60, P = 0.0003 during Sinus and R = 0.66, P < 0.0001 during atrial pacing) and RA-RV interval (R = 0.47, P = 0.009 during Sinus and R = 0.66, P < 0.0001 during atrial pacing). The electrical intervals were prolonged by the increased atrial pacing rate. CONCLUSION: IACT is a critical determinant of the optimal AV for CRT programming. Heart rate-dependent AV shortening may not be appropriate for CRT patients during atrial pacing.


Assuntos
Potenciais de Ação , Nó Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/prevenção & controle , Insuficiência Cardíaca/fisiopatologia , Idoso , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Estatística como Assunto
5.
Opt Express ; 16(21): 16609-15, 2008 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-18852770

RESUMO

We report the generation of an optical time division multiplexed single data channel at 160 Gb/s using a one-pump fiber-optic parametric amplifier, and its subsequent multicasting. A two-pump fiber optic parametric amplifier was used to perform all-optical multicasting of 160 Gb/s channel to four data streams. New processing scheme combined the increase in signal extinction ratio and low-impairment multicasting using continuous-wave parametric pumps. Selective conjugation of 160 Gb/s was demonstrated for the first time.


Assuntos
Amplificadores Eletrônicos , Desenho Assistido por Computador , Modelos Teóricos , Dispositivos Ópticos , Processamento de Sinais Assistido por Computador/instrumentação , Telecomunicações/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Micro-Ondas , Espalhamento de Radiação
6.
Circulation ; 113(20): 2383-90, 2006 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-16702470

RESUMO

BACKGROUND: Pharmacological ventricular rate control is an acceptable atrial fibrillation (AF) therapy limited by systemic toxicity. We postulate that focal catheter-based drug delivery into the atrioventricular nodal (AVN) region may effectively control ventricular rate during AF without systemic toxicity. This study evaluated the effects of focally administered acetylcholine on AVN conduction and refractoriness during sinus rhythm and AF. METHODS AND RESULTS: Canines (n=7) were anesthetized and instrumented to assess cardiac electrophysiology and blood pressure. A custom drug delivery catheter was implanted in the AVN region. Incremental doses of acetylcholine starting at 10 microg/min were infused until complete AV block was achieved. Acetylcholine induced dose-dependent AV block. AF induction and electrophysiology measurements were performed during baseline and acetylcholine-induced first-degree and third-degree AV block. During AF, infusion of acetylcholine decreased ventricular rates from 182+/-32 to 77+/-28 and 28+/-8 bpm (first-degree and third-degree AV block, respectively; P<0.05). At the first-degree AV block dose, AVN effective refractory period increased from 186+/-37 to 282+/-33 ms, and Wenckebach cycle length increased from 271+/-29 to 378+/-58 ms (P<0.05). The first-degree AV block dose prolonged AV and AH intervals by 26% and 23% (P<0.05), whereas AA intervals and blood pressure remained unchanged, demonstrating a local effect. All effects were reversed 20 minutes after infusion was stopped. CONCLUSIONS: Focal acetylcholine delivery into the AVN increased AVN refractoriness and significantly decreased ventricular rate response during induced AF in a dose-related, reversible manner without systemic side effects. This may represent a novel therapy for AF whereby ventricular rate is controlled with the use of an implantable drug delivery system.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Nó Atrioventricular/fisiopatologia , Cateteres de Demora , Frequência Cardíaca/fisiologia , Condução Nervosa/fisiologia , Acetilcolina/administração & dosagem , Acetilcolina/uso terapêutico , Animais , Modelos Animais de Doenças , Cães , Sistemas de Liberação de Medicamentos , Feminino , Masculino , Vasodilatadores/administração & dosagem , Vasodilatadores/uso terapêutico
7.
Prog Biophys Mol Biol ; 90(1-3): 26-37, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-15979128

RESUMO

A transformed line of human embryonic kidney epithelial cells (HEK 293) is commonly used as an expression system for exogenous ion channel genes. Previously, it has been shown that these cells contain mRNAs for a variety of ion channels. Expression of some of these genes has been confirmed at the protein level. Patch-clamp electrophysiology experiments confirm the presence of multiple ion channels and molecular data agree with pharmacological profiles of identified channels. In this work, we show that endogenous voltage-gated potassium channels in HEK cells are a significant source of outward current at positive potentials. We show that both non-transfected HEK cells and HEK cells transfected with hyperpolarization-activated cyclic-nucleotide gated (HCN) channels have a significant amount of voltage-gated potassium (K(V)) current when certain tail current voltage-clamp protocols are used to assay HCN current activation. Specifically, tail current protocols that use a depolarized holding potential of -40 mV followed by hyperpolarizing pulses (-80 to -140 mV) and then a tail pulse potential of +20 mV indicate K(V) channels undergo closed-state inactivation at the more depolarized holding potential of -40 mV, followed by recovery from inactivation (but no activation) at hyperpolarizing potentials and high amount of activation at the positive tail potential. Our results indicate that pulse protocols with positive tail pulses are inaccurate assays for HCN current in certain HEK cells. Surprisingly, HEK-293 cells were found to contain mRNA for HCN2 and HCN3 although we have not detected a significant and consistent endogenous I(f)-like current in these cells.


Assuntos
Ativação do Canal Iônico , Canais Iônicos/fisiologia , Linhagem Celular , Canais de Cátion Regulados por Nucleotídeos Cíclicos , Humanos , Canais Disparados por Nucleotídeos Cíclicos Ativados por Hiperpolarização , Proteínas Musculares/fisiologia , Técnicas de Patch-Clamp , Canais de Potássio , Canais de Potássio de Abertura Dependente da Tensão da Membrana/fisiologia
8.
J Cardiovasc Electrophysiol ; 18(3): 290-5, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17313655

RESUMO

BACKGROUND: Optimizing atrioventricular (AV) delay during biventricular (BiV) pacemaker implantation can require substantial resources. Hence, a simpler method is desirable. We hypothesized that interatrial conduction time (IACT), measured at the time of BiV device implant, could be a surrogate value for the optimal AV delay. OBJECTIVE: This study determined the relationship between paced IACT and the optimal paced AV delay (PAV), as determined by echocardiography. METHODS: Consecutive subjects (N = 25; age = 66 +/- 10 years; M/F: 17/8) undergoing BiV pacemaker implantation and in sinus rhythm were included. Cannulation of the coronary sinus (CS) was at the operator's discretion. A quadripolar electrophysiology catheter was inserted via the guiding sheath into the inferiolateral CS to measure left atrial depolarization. The IACT was calculated as the interval between right atrial stimulation artifact and earliest deflection on the coronary sinus catheter electrogram. Subsequently, during atrial pacing the PAV was determined using transmitral pulsed wave Doppler echocardiography (iterative method). The relationship between paced IACT and PAV was then determined. RESULTS: The mean +/- SD paced IACT and PAV were 126 +/- 25 msec and 157 +/- 23 msec, respectively. There was a strong positive correlation between the paced IACT and PAV (r = 0.73, P < 0.001). The equation describing the relationship was PAV = 0.68 * (IACT + 104) msec. CONCLUSIONS: The paced IACT has a strong correlation with the echo derived optimal PAV. This method may be used to program PAV intervals without need for echocardiography in patients undergoing BiV pacemaker implantation.


Assuntos
Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Implantação de Prótese/métodos , Resultado do Tratamento , Ultrassonografia
9.
Int J Nurs Stud ; 44(2): 175-82, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17064706

RESUMO

CONTEXT: Despite growing evidence in the US, little evidence has been available to evaluate whether internationally, hospitals in which nurses care for fewer patients have better outcomes in terms of patient survival and nurse retention. OBJECTIVES: To examine the effects of hospital-wide nurse staffing levels (patient-to-nurse ratios) on patient mortality, failure to rescue (mortality risk for patients with complicated stays) and nurse job dissatisfaction, burnout and nurse-rated quality of care. DESIGN AND SETTING: Cross-sectional analysis combining nurse survey data with discharge abstracts. PARTICIPANTS: Nurses (N=3984) and general, orthopaedic, and vascular surgery patients (N=118752) in 30 English acute trusts. RESULTS: Patients and nurses in the quartile of hospitals with the most favourable staffing levels (the lowest patient-to-nurse ratios) had consistently better outcomes than those in hospitals with less favourable staffing. Patients in the hospitals with the highest patient to nurse ratios had 26% higher mortality (95% CI: 12-49%); the nurses in those hospitals were approximately twice as likely to be dissatisfied with their jobs, to show high burnout levels, and to report low or deteriorating quality of care on their wards and hospitals. CONCLUSIONS: Nurse staffing levels in NHS hospitals appear to have the same impact on patient outcomes and factors influencing nurse retention as have been found in the USA.


Assuntos
Recursos Humanos de Enfermagem Hospitalar , Alta do Paciente , Admissão e Escalonamento de Pessoal/organização & administração , Qualidade da Assistência à Saúde , Adulto , Idoso , Idoso de 80 Anos ou mais , Atitude do Pessoal de Saúde , Esgotamento Profissional/epidemiologia , Esgotamento Profissional/psicologia , Estudos Transversais , Inglaterra/epidemiologia , Feminino , Número de Leitos em Hospital/estatística & dados numéricos , Mortalidade Hospitalar , Humanos , Satisfação no Emprego , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Pesquisa em Administração de Enfermagem , Pesquisa Metodológica em Enfermagem , Recursos Humanos de Enfermagem Hospitalar/psicologia , Recursos Humanos de Enfermagem Hospitalar/provisão & distribuição , Avaliação de Resultados em Cuidados de Saúde , Inquéritos e Questionários , Carga de Trabalho
10.
Exp Biol Med (Maywood) ; 242(9): 986-995, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28440739

RESUMO

Ischemic preconditioning has been utilized to protect the heart from ischemia prior to ischemia onset, whereas postconditioning is employed to minimize the consequences of ischemia at the onset of reperfusion. The underlying mechanisms and pathways of ischemic pre- and postconditioning continue to be investigated as therapeutic targets. We evaluated the administration of a delta opioid agonist or cariporide on various parameters associated with myocardial reperfusion injury upon reperfusion of isolated porcine hearts. The hearts were reperfused in vitro with a Krebs buffer containing either: (1) 1 µM Deltorphin D (delta opioid specific agonist, n = 6); (2) 3 µM cariporide (sodium-hydrogen exchange inhibitor, n = 4); or (3) no treatment (control, n = 6). Subsequently, postischemic hemodynamic performance, arrhythmia burden, relative tissue perfusion, and development of necrosis were assessed over a 2 h reperfusion period. Postconditioning with Deltorphin D significantly improved diastolic relaxation (Tau, P < 0.05 versus controls) and decreased the incidence of ventricular arrhythmias during early reperfusion. Additionally, these treated hearts demonstrated increased tissue perfusion after 2 h ( P < 0.05 versus controls), suggesting improved microvascular function. Delta opioid agonists elicited the potential to attenuate reperfusion injury, suggesting a postconditioning effect of these agents. We hypothesize that the induced benefits of delta opioids, in part, are associated with decreased calcium influx on reperfusion, independent of sodium-hydrogen exchange inhibition. Such agents may have a potential role in minimizing reperfusion injury associated with coronary stenting, bypass surgery, myocardial infarction, cardiac transplantation, or with the utilization of heart preservation systems. Impact statement In this study, we found that postconditioning with Deltorphin D significantly improved diastolic relaxation and decreased the incidence of ventricular arrhythmias during early reperfusion. Furthermore, these treated hearts demonstrated increased tissue perfusion after 2 h, suggesting improved microvascular function. Delta opioid agonists attenuated reperfusion injury, suggestive of a postconditioning effect. Such agents may have a potential role in minimizing reperfusion injury associated with coronary stenting, bypass surgery, myocardial infarction, cardiac transplantation, or with the utilization of heart preservation systems.


Assuntos
Coração/fisiologia , Pós-Condicionamento Isquêmico/métodos , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Oligopeptídeos/administração & dosagem , Animais , Guanidinas/administração & dosagem , Sulfonas/administração & dosagem , Suínos
11.
Heart Rhythm ; 3(7): 824-31, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16818216

RESUMO

BACKGROUND: Normal cardiac rhythm is critically dependent on the sinoatrial (SA) node, the natural biological pacemaker. Although recent studies have focused on the development of "artificial" biological pacemakers using gene transfer, less is known about the functional consequences of such interventions. OBJECTIVE: The purpose of this study was to investigate the electrophysiological consequences of two approaches used to create a biological pacemaker: overexpression of the hyperpolarization-activated cyclic nucleotide gated channel (HCN "pacemaker" channels) and suppression of the inward-rectifier potassium current, I(K1). METHODS: We used a linear multicellular Luo-Rudy (LRd) AP model consisting of 130 ventricular cells connected by resistive gap junctions. To induce automaticity, I(K1) current was reduced or I(f) (HCN) current was introduced in endocardial and midmyocardial (M) cells. RESULTS: Similar to the previously published results for a single LRd model, myocyte I(K1) suppression induced automaticity in the fiber. While introduction of I(f) also resulted in automaticity, the main differences between I(K1) suppression and I(f) expression were (1) a relatively more gradual phase 4 depolarization with HCN expression, (2) stabilization of cycle lengths during I(K1) suppression, but not during HCN expression, and (3) responsiveness to beta-adrenergic stimulation during HCN expression, but not during I(K1) suppression. Upon further investigation, we found that cycle length instability during HCN expression was primarily due to a gradual reduction of intracellular potassium ([K(+)](i)) from its baseline value of 142 mM to 120 mM in 600 beats and subsequent alteration of potassium-dependent ionic currents. A twofold increase in HCN expression also led to a similar behavior. We attribute this decrease in [K(+)](i) to a large I(K1) during phase 4 depolarization. When intracellular [K(+)](i) loss was minimized, cycle lengths stabilized during HCN expression. CONCLUSIONS: Our results help to further understand the electrophysiologic consequences as well as some of the challenges associated with the creation of biological pacemakers using HCN and I(K1) gene transfer strategies.


Assuntos
Ventrículos do Coração/metabolismo , Canais Iônicos/biossíntese , Modelos Teóricos , Miócitos Cardíacos/metabolismo , Marca-Passo Artificial , Potássio/metabolismo , Potenciais de Ação/fisiologia , Canais de Cátion Regulados por Nucleotídeos Cíclicos , Técnicas de Transferência de Genes , Ventrículos do Coração/citologia , Humanos , Canais Disparados por Nucleotídeos Cíclicos Ativados por Hiperpolarização , Técnicas In Vitro , Líquido Intracelular/metabolismo , Canais Iônicos/genética , Proteínas do Tecido Nervoso/biossíntese , Proteínas do Tecido Nervoso/genética , Canais de Potássio , Transdução de Sinais/fisiologia
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 2083-2086, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28268741

RESUMO

People with low vision have limited residual vision that can be greatly enhanced through high levels of magnification. Current assistive technologies are tailored for far field or near field magnification but not both. In collaboration with L.V. Prasad Eye Institute (LVPEI), a wearable, optical-digital assistive device was developed to meet the near and far field magnification needs of students. The critical requirements, system architecture and design decisions for each module were analyzed and quantified. A proof-of-concept prototype was fabricated that can achieve magnification up to 8x and a battery life of up to 8 hours. Potential user evaluation with a Snellen chart showed identification of characters not previously discernible. Further feedback suggested that the system could be used as a general accessibility aid.


Assuntos
Dispositivos Ópticos , Tecnologia Assistiva , Baixa Visão , Humanos , Estudantes , Acuidade Visual
13.
Biochem Pharmacol ; 69(11): 1553-8, 2005 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-15896334

RESUMO

INTRODUCTION: Myocardial edema is a clinically relevant problem found in post-ischemic reperfused hearts. The objective of this study was to understand the effects of hetastarch-supplemented cardioplegia on post-ischemic edema and cardiac function. MATERIALS AND METHODS: Swine hearts were arrested with either St. Thomas Hospital cardioplegia with (n=6) or without (n=7) 1.5% hetastarch. Following hypothermic global ischemia, hearts were crystalloid reperfused in a four-chamber isolated working mode. RESULTS: Hetastarch decreased myocardial water content gains after three hours of reperfusion (control versus hetastarch, hour 0: 67+/-5% versus 67+/-3%, NS; hour 3: 82+/-2% versus 78+/-1%, p=0.1). Post-ischemic control group left ventricular end-diastolic pressures were elevated after 1h (in mm Hg, hour 0: 13+/-2, hour 1: 19+/-3, hour 2: 19+/-3, hour 3: 20+/-2) but remained stable (<16 mm Hg) in the hetastarch group. Post-reperfusion creatine phosphokinase perfusate levels in the hetastarch treated hearts were decreased (control: 1.6 IU/l/g versus hetastarch: 0.6 IU/l/g, p=0.15). DISCUSSION/CONCLUSIONS: Hetastarch treatment delayed myocardial edema development and attenuated myocardial creatine kinase efflux, thereby preserving diastolic function.


Assuntos
Soluções Cardioplégicas/farmacologia , Parada Cardíaca Induzida/métodos , Coração/efeitos dos fármacos , Derivados de Hidroxietil Amido/farmacologia , Animais , Coração/fisiologia , Técnicas In Vitro , Suínos
14.
Am J Cardiol ; 110(9): 1309-14, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22819433

RESUMO

The detection of undiagnosed atrial tachycardia/atrial fibrillation (AT/AF) among patients with stroke risk factors could be useful for primary stroke prevention. We analyzed newly detected AT/AF (NDAF) using continuous monitoring in patients with stroke risk factors but without previous stroke or evidence of AT/AF. NDAF (AT/AF >5 minutes on any day) was determined in patients with implantable cardiac rhythm devices and ≥1 stroke risk factors (congestive heart failure, hypertension, age ≥75 years, or diabetes). All devices were capable of continuously monitoring the daily cumulative time in AT/AF. Of 1,368 eligible patients, NDAF was identified in 416 (30%) during a follow-up of 1.1 ± 0.7 years and was unrelated to the CHADS(2) score (congestive heart failure, hypertension [blood pressure consistently >140/90 mm Hg or hypertension treated with medication], age ≥75 years, diabetes mellitus, previous stroke or transient ischemic attack). The presence of AT/AF >6 hours on ≥1 day increased significantly with increased CHADS(2) scores and was present in 158 (54%) of 294 patients with NDAF and a CHADS(2) score of ≥2. NDAF was sporadic, and 78% of patients with a CHADS(2) score of ≥2 with NDAF experienced AT/AF on <10% of the follow-up days. The median interval to NDAF detection in these higher risk patients was 72 days (interquartile range 13 to 177). In conclusion, continuous monitoring identified NDAF in 30% of patients with stroke risk factors. In patients with NDAF, AT/AF occurred sporadically, highlighting the difficulty in detecting paroxysmal AT/AF using traditional monitoring methods. However, AT/AF also persisted for >6 hours on ≥1 days in most patients with NDAF and multiple stroke risk factors. Whether patients with CHADS(2) risk factors but without a history of AF might benefit from implantable monitors for the selection and administration of anticoagulation for primary stroke prevention merits additional investigation.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Monitorização Fisiológica/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/métodos , Estudos de Coortes , Terapia Combinada , Desfibriladores Implantáveis , Diagnóstico Tardio , Feminino , Seguimentos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Fatores de Risco , Índice de Gravidade de Doença , Distribuição por Sexo , Acidente Vascular Cerebral/fisiopatologia , Análise de Sobrevida , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 29(6): 679-81, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16784436

RESUMO

Limited data exist on the utilization of a transvenous A-sense; V-pace/sense (VDD)pacing system with a chronically retained nonfunctioning endocardial V-sense/pace (VVI)pacing lead. In an acute canine model, no atrial oversensing was observed with lead-lead interaction between the VDD lead and the pseudo-retained VVI lead. Undersensing occurred <10% of all beats observed.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Animais , Cães , Átrios do Coração/fisiopatologia , Modelos Animais
17.
Muscle Nerve ; 32(2): 200-7, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15940690

RESUMO

A link between the cardioprotective benefits of pharmacological preconditioning and natural mammalian hibernation is considered to involve the cellular activation of opioid receptors and subsequent opening of K(ATP) channels. In previous studies, we have demonstrated the protective effects of specific delta-opioid agonists against porcine cardiac ischemia/reperfusion injury. We hypothesize here that preincubation with hibernation induction trigger (HIT) should confer a similar protection in skeletal muscles. Therefore, muscle bundles from swine were pretreated with plasma from hibernating woodchucks (HWP) for 30 min, then exposed to hypoxia for 90 min and reoxygenation for 120 min. Stimulated twitch forces were assessed. The functional effects of pretreatment with nonhibernation (summer) woodchuck plasma, a K(ATP) blocker, or opioid antagonist were also studied. During the reoxygenation period, significantly greater force recoveries were observed only for bundles pretreated with HWP; this response was blocked by naloxone (P < 0.05). We conclude that HIT pretreatment could be used to confer protection against hypoxia/reperfusion injury of skeletal muscles of nonhibernators; it could potentially be utilized to prevent injury during surgical procedures requiring ischemia.


Assuntos
Hibernação/fisiologia , Hipóxia/tratamento farmacológico , Precondicionamento Isquêmico/métodos , Músculo Esquelético/efeitos dos fármacos , Proteínas/farmacologia , Traumatismo por Reperfusão/tratamento farmacológico , Animais , Proteínas Sanguíneas/metabolismo , Proteínas Sanguíneas/farmacologia , Hipóxia/fisiopatologia , Hipóxia/prevenção & controle , Marmota/fisiologia , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Contração Muscular/efeitos dos fármacos , Contração Muscular/fisiologia , Fadiga Muscular/efeitos dos fármacos , Fadiga Muscular/fisiologia , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiopatologia , Antagonistas de Entorpecentes/farmacologia , Peptídeos , Bloqueadores dos Canais de Potássio/farmacologia , Canais de Potássio/efeitos dos fármacos , Canais de Potássio/metabolismo , Proteínas/metabolismo , Receptores Opioides/efeitos dos fármacos , Receptores Opioides/metabolismo , Recuperação de Função Fisiológica/efeitos dos fármacos , Recuperação de Função Fisiológica/fisiologia , Traumatismo por Reperfusão/fisiopatologia , Traumatismo por Reperfusão/prevenção & controle , Estações do Ano , Sus scrofa
18.
Ann Thorac Surg ; 79(1): 168-77, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15620938

RESUMO

BACKGROUND: Isolated mammalian hearts have been used in numerous studies that have led to many important discoveries in cardiac physiology, pharmacology, and surgery. Multiple methods of perfusion have been described including retrograde and/or antegrade flows and crystalloid or blood perfusates. Furthermore, multiple species have been utilized for such studies including the following: rat, rabbit, guinea pig, canine, and swine. The objective of this study was to describe a unique isolated heart preparation, utilizing human hearts not viable for transplant, which allows for physiologic perfusion and endocardial imaging. METHODS: Utilizing standard cardiac transplantation procedures, 12 human hearts deemed not viable for transplant were explanted to an isolated heart apparatus. A clear, modified Krebs-Henseleit buffer was used as a blood substitute, which allowed for endocardial imaging utilizing 6.0 mm endoscopic video cameras inserted into the cardiac chambers. The hearts were perfused in Langendorff (retrograde) and/or working (physiologic) mode. RESULTS: Eleven of 12 hearts achieved the following performance in working mode: peak left ventricular pressure of 21.5 to 75.8 mm Hg, with an average of 42.7 +/- 19.9 mm Hg. Intracardiac anatomical imaging was possible in all hearts, providing unique views of normal and pathological endocardial anatomy as well as biomedical device-heart interactions. CONCLUSIONS: We have described a unique isolated heart preparation with which we have successfully reanimated 11 human hearts deemed not viable for transplant, perfused them by working mode, and performed intracardiac anatomical imaging. This approach provides a novel means for obtaining images of functional human cardiac anatomy and various types of unique biomedical assessments.


Assuntos
Coração , Técnicas de Cultura de Órgãos/métodos , Adulto , Idoso , Cateterismo Cardíaco , Cardiotônicos/farmacologia , Meios de Cultura , Dobutamina/farmacologia , Cardioversão Elétrica , Eletrocardiografia , Epinefrina/farmacologia , Desenho de Equipamento , Feminino , Fluoroscopia , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Coração/efeitos dos fármacos , Coração/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Cultura de Órgãos/instrumentação , Perfusão , Coleta de Tecidos e Órgãos
19.
Am J Physiol Heart Circ Physiol ; 284(6): H2091-9, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12543635

RESUMO

Pharmacological preconditioning with kappa-opioid receptor agonists is proarrhythmic and exerts antipreconditioning effects in rats. In swine, it is unknown whether kappa-opioid receptor stimulation plays a role in pharmacological preconditioning. Swine were preconditioned with 1) saline (controls), 2) [d-Ala(2),d-Leu(5)]enkephalin (DADLE), 3) morphine, 4) pentazocine, 5) norbinaltorphimine (nor-BNI), 6) DADLE + nor-BNI, 7) morphine + nor-BNI, or 8) pentazocine + nor-BNI before occlusion (45 min) and reperfusion (180 min) of the left anterior descending coronary artery. Infarct size to area at risk (IS), regional (systolic shortening) and global (pressures and flows) myocardial function, and arrhythmia occurrence were assessed. Only DADLE + nor-BNI preconditioning significantly decreased infarct size compared with controls (47 +/- 13 vs. 65 +/- 5%, P < 0.05); morphine preconditioning was not cardioprotective with or without kappa-opioid receptor blockade (nor-BNI). DADLE preconditioning significantly increased ischemia-induced arrhythmias relative to controls, whereas pentazocine-preconditioned animals (n = 2) experienced intractable ventricular fibrillation during ischemia. kappa-Opioid receptor blockade with DADLE or pentazocine preconditioning alleviated proarrhythmic effects. These results suggest that kappa-opioid receptor activation during pharmacological preconditioning is proarrhythmic in swine.


Assuntos
Precondicionamento Isquêmico Miocárdico , Naltrexona/análogos & derivados , Entorpecentes/farmacologia , Receptores Opioides kappa/fisiologia , Animais , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/prevenção & controle , Circulação Coronária/efeitos dos fármacos , Circulação Coronária/fisiologia , Leucina Encefalina-2-Alanina/farmacologia , Hemodinâmica/efeitos dos fármacos , Morfina/farmacologia , Infarto do Miocárdio/induzido quimicamente , Infarto do Miocárdio/patologia , Infarto do Miocárdio/prevenção & controle , Isquemia Miocárdica/patologia , Naltrexona/farmacologia , Antagonistas de Entorpecentes/farmacologia , Pentazocina/farmacologia , Receptores Opioides kappa/agonistas , Suínos
20.
Am J Physiol Heart Circ Physiol ; 282(6): H1953-60, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12003798

RESUMO

Opioids are involved in cardiac ischemic preconditioning. Important species differences in cellular signaling mechanisms, antiarrhythmic, and antistunning effects have been described. The role of the delta-opioid receptor activation in swine remains unknown. Forty minutes before a 45-min occlusion and 180-min reperfusion of the left anterior descending coronary artery, open-chest, pentobarbital-anesthetized swine received either 1) saline (controls); 2) [D-Ala(2),D-Leu(5)]enkephalin (DADLE); 3) [D-Pen(2,5)]enkephalin (DPDPE); 4) deltorphin-D, a novel delta(2)-opioid agonist; or 5) ischemic preconditioning (IP). Assessed were 1) infarct size to area at risk (IS, triphenyltetrazolium staining), 2) regional and global myocardial function (sonomicrometry, ventricular pressure catheters), and 3) arrhythmias (electrocardiogram analyses). It was found that DPDPE and deltorphin-D pretreatment reduced IS from 64.7 +/- 5 to 36.5 +/- 6% and 27.4 +/- 11% (P < 0.01), respectively, whereas DADLE had no effect (66.8 +/- 3%). Both IP and DADLE had a proarrhythmic effect (P < 0.01). However, no differences in global or regional myocardial function or arrhythmia scores were observed between groups. This suggests that delta-receptor-specific opioids provide cardioprotection in swine.


Assuntos
Cardiotônicos/uso terapêutico , Precondicionamento Isquêmico Miocárdico , Infarto do Miocárdio/patologia , Receptores Opioides delta/agonistas , Receptores Opioides delta/fisiologia , Animais , Arritmias Cardíacas/epidemiologia , Eletrocardiografia , D-Penicilina (2,5)-Encefalina/uso terapêutico , Leucina Encefalina-2-Alanina/uso terapêutico , Hemodinâmica , Infarto do Miocárdio/fisiopatologia , Isquemia Miocárdica , Reperfusão Miocárdica , Oligopeptídeos/uso terapêutico , Especificidade da Espécie , Suínos , Pressão Ventricular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa