Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JAMIA Open ; 6(1): ooac108, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36632328

RESUMO

The objective of this study is to describe application of the Observational Medical Outcomes Partnership (OMOP) common data model (CDM) to support medical device real-world evaluation in a National Evaluation System for health Technology Coordinating Center (NESTcc) Test-Case involving 2 healthcare systems, Mercy Health and Mayo Clinic. CDM implementation was coordinated across 2 healthcare systems with multiple hospitals to aggregate both medical device data from supply chain databases and patient outcomes and covariates from electronic health record data. Several data quality assurance (QA) analyses were implemented on the OMOP CDM to validate the data extraction, transformation, and load (ETL) process. OMOP CDM-based data of relevant patient encounters were successfully established to support studies for FDA regulatory submissions. QA analyses verified that the data transformation was robust between data sources and OMOP CDM. Our efforts provided useful insights in real-world data integration using OMOP CDM for medical device evaluation coordinated across multiple healthcare systems.

2.
JAMA Netw Open ; 5(8): e2227134, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35976649

RESUMO

Importance: The ThermoCool SmartTouch catheter (ablation catheter with contact force and 6-hole irrigation [CF-I6]) is approved by the US Food and Drug Administration (FDA) for paroxysmal atrial fibrillation (AF) ablation and used in routine clinical practice for persistent AF ablation, although clinical outcomes for this indication are unknown. There is a need to understand whether data from routine clinical practice can be used to conduct regulatory-grade evaluations and support label expansions. Objective: To use health system data to compare the safety and effectiveness of the CF-I6 catheter for persistent AF ablation with the ThermoCool SmartTouch SurroundFlow catheter (ablation catheter with contact force and 56-hole irrigation [CF-I56]), which is approved by the FDA for this indication. Design, Setting, and Participants: This retrospective, comparative-effectiveness cohort study included patients undergoing catheter ablation for persistent AF at Mercy Health or Mayo Clinic from January 1, 2014, to April 30, 2021, with up to a 1-year follow-up using electronic health record data. Exposures: Use of the CF-I6 or CF-I56 catheter. Main Outcomes and Measures: The primary safety outcome was a composite of death, thromboembolic events, and procedural complications within 7 to 90 days. The exploratory effectiveness outcome was a composite of AF-related hospitalization events after a 90-day blanking period. Propensity score weighting was used to balance baseline covariates. Risk differences were estimated between catheter groups and averaged across the 2 health care systems, testing for noninferiority of the CF-I6 vs the CF-I56 catheter with respect to the safety outcome using 2-sided 90% CIs. Results: Overall, 1450 patients (1034 [71.3%] male; 1397 [96.3%] White) underwent catheter ablation for persistent AF, including 949 at Mercy Health (186 CF-I6 and 763 CF-I56; mean [SD] age, 64.9 [9.2] years) and 501 at Mayo Clinic (337 CF-I6 and 164 CF-I56; mean [SD] age, 63.7 [9.5] years). A total of 798 (55.0%) had been treated with class I or III antiarrhythmic drugs before ablation. The safety outcome (CF-I6 - CF-I56) was similar at both Mercy Health (1.3%; 90% CI, -2.1% to 4.6%) and Mayo Clinic (-3.8%; 90% CI, -11.4% to 3.7%); the mean difference was noninferior, with a mean of 0.5% (90% CI, -2.6% to 3.5%; P < .001). The effectiveness was similar at 12 months between the 2 catheter groups (mean risk difference, -1.8%; 90% CI, -7.3% to 3.7%). Conclusions and Relevance: In this cohort study, the CF-I6 catheter met the prespecified noninferiority safety criterion for persistent AF ablation compared with the CF-I56 catheter, and effectiveness was similar. This study demonstrates the ability of electronic health care system data to enable safety and effectiveness evaluations of medical devices.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
3.
BMJ Surg Interv Health Technol ; 3(1): e000089, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047806

RESUMO

OBJECTIVES: To determine the feasibility of using real-world data to assess the safety and effectiveness of two cardiac ablation catheters for the treatment of persistent atrial fibrillation and ischaemic ventricular tachycardia. DESIGN: Retrospective cohort. SETTING: Three health systems in the USA. PARTICIPANTS: Patients receiving ablation with the two ablation catheters of interest at any of the three health systems. MAIN OUTCOME MEASURES: Feasibility of identifying the medical devices and participant populations of interest as well as the duration of follow-up and positive predictive values (PPVs) for serious safety (ischaemic stroke, acute heart failure and cardiac tamponade) and effectiveness (arrhythmia-related hospitalisation) clinical outcomes of interest compared with manual chart validation by clinicians. RESULTS: Overall, the catheter of interest for treatment of persistent atrial fibrillation was used for 4280 ablations and the catheter of interest for ischaemic ventricular tachycardia was used 1516 times across the data available within the three health systems. The duration of patient follow-up in the three health systems ranged from 91% to 97% at ≥7 days, 89% to 96% at ≥30 days, 77% to 90% at ≥6 months and 66% to 84% at ≥1 year. PPVs were 63.4% for ischaemic stroke, 96.4% for acute heart failure, 100% at one health system for cardiac tamponade and 55.7% for arrhythmia-related hospitalisation. CONCLUSIONS: It is feasible to use real-world health system data to evaluate the safety and effectiveness of cardiac ablation catheters, though evaluations must consider the implications of variation in follow-up and endpoint ascertainment among health systems.

SELEÇÃO DE REFERÊNCIAS