Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(2): e13860, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36565180

RESUMO

This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95-23.01) to 2.36 µSv (IQR, 0.52-12.66) (-36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 µSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 µSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (-30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação , Humanos , Doses de Radiação , Estudos Prospectivos , Retroalimentação Sensorial , Radiometria , Lesões por Radiação/prevenção & controle , Exposição à Radiação/prevenção & controle , Exposição Ocupacional/prevenção & controle , Radiografia Intervencionista , Fluoroscopia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa