Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Microsc ; 265(3): 313-321, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27896802

RESUMO

A method is presented, which allows quantification of the roughness of nonplanar boundaries of objects for which the neutral plane is not known. The method provides quantitative descriptions of both the local and global characteristics. How the method can be used to estimate the sizes of rough features and local curvatures is also presented. The potential of the method is illustrated by quantification of the roughness of two recrystallization boundaries in a pure Al specimen characterized by scanning electron microscopy.

2.
Nanoscale ; 8(21): 11002-11, 2016 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-27174233

RESUMO

Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gelation matrix composed of sucrose acetate isobutyrate has been developed for use as an in vivo dosimeter for external beam radiotherapy. In situ photonuclear reactions trigger the formation of radioactive (106)Ag, which enables post treatment verification of the delivered dose using positron emission tomography imaging. The silver-nanosensor was investigated in a tissue equivalent thorax phantom using clinical settings and workflow for both standard fractionated radiotherapy (2 Gy) and stereotactic radiotherapy (10- and 22 Gy) in a high-energy beam setting (18 MV). The developed silver-nanosensor provided high radiopacity on the planning CT-scans sufficient for patient positioning in image-guided radiotherapy and provided dosimetric information about the absorbed dose with a 10% and 8% standard deviation for the stereotactic regimens, 10 and 22 Gy, respectively.


Assuntos
Dosimetria in Vivo , Nanopartículas Metálicas , Tomografia por Emissão de Pósitrons , Radioterapia , Prata , Humanos , Posicionamento do Paciente , Imagens de Fantasmas
3.
IEEE Trans Med Imaging ; 19(11): 1053-63, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11204843

RESUMO

From a set of longitudinal three-dimensional scans of the same anatomical structure, we have accurately modeled the temporal shape and size changes using a linear shape model. On a total of 31 computed tomography scans of the mandible from six patients, 14,851 semilandmarks are found automatically using shape features and a new algorithm called geometry-constrained diffusion. The semilandmarks are mapped into Procrustes space. Principal component analysis extracts a one-dimensional subspace, which is used to construct a linear growth model. The worst case mean modeling error in a cross validation study is 3.7 mm.


Assuntos
Mandíbula/anatomia & histologia , Mandíbula/crescimento & desenvolvimento , Antropometria , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Lactente , Masculino
4.
Semin Ultrasound CT MR ; 13(2): 135-9, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1599731

RESUMO

Using the computer as a diagnostic tool is a normal everyday function of modern radiology departments with CT, MRI, and ultrasound. This article describes the preliminary results using the computer as a coworker in a diagnostic scrutinizing process. Conventional analogous mammographic films were digitized and analyzed. Promising results were obtained detecting microcalcifications, dense areas, and their borderlines and stellate configurations. There are problems with detecting skin changes, probably caused by insufficient digitizing.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia , Interpretação de Imagem Radiográfica Assistida por Computador , Computadores , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Projetos Piloto , Software
5.
Scand J Clin Lab Invest ; 53(3): 215-23, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8316750

RESUMO

In an earlier study it was shown, that, in a hospital population, only about 30% of patients with hypercalcaemia had the diagnosis identified and so an alarm filter was developed, at the laboratory level, to differentiate between clinically significant and clinically non-significant hypercalcaemia. The filter correctly classified 84% and 77% of women and men with hypercalcaemia, respectively, with respect to the clinical significance of the hypercalcaemia. The sensitivity and the specificity of the discriminant functions were 90% and 73% in women and 80% and 67% in men. The alarm filter was based on a two-step procedure. The patients were primarily classified by the discriminant functions into one of the following medical diagnoses related to hypercalcaemia: primary hyperparathyroidism, malignancy, and transient hypercalcaemia. Based on this classification the patients were characterized as having either a clinically significant or non-significant hypercalcaemia. The alarm filter was based on two discriminant functions. The discriminant variables were phosphate, albumin, protein, LD, and a haemoglobin in women, and albumin, protein, ALP, and age in men. Missing values were estimated. The discriminant variables were selected from 17 possible discriminant variables, all measured by routine, and age. The study group comprised 257 patients with hypercalcaemia, consecutively registered, during half a year. The classification efficiency of the discriminant functions were based on comparison of results obtained by cross-validation of the discriminant functions, and the medical diagnosis decided by the clinicians in the respective departments of the hospital. The medical diagnoses were based on principles and definitions generally used in the departments with no knowledge of the results assessed by the discriminant functions.


Assuntos
Hipercalcemia/diagnóstico , Idoso , Proteínas Sanguíneas/análise , Cálcio/sangue , Feminino , Hemoglobinas/análise , Humanos , Hipercalcemia/etiologia , Hiperparatireoidismo/complicações , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Fosfatos/sangue , Albumina Sérica/análise , Fatores Sexuais
6.
Anal Biochem ; 165(2): 384-91, 1987 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3425908

RESUMO

A computerized method for automatic evaluation and comparison of crossed immunoelectrophoretic and crossed radioimmunoelectrophoretic patterns that requires limited hardware resources has been developed. For the initial reading of the plates an ordinary video camera is used. Feature extractors that allow the computer to recognize a point on the precipitation curve as being a peak point have been developed. After this automatic procedure the program allows for an interactive menu-driven proofreading phase during which it is possible to force the system to take into consideration any number of extra points along the precipitation curve in the curve-fitting process. The system has been tested on crossed immunoelectrophoretic patterns as well as crossed radioimmunoelectrophoretic patterns and it has been shown that the system can recognize the same precipitation curves on different immunoplates and autoradiographs. In addition, the system reports the mean, the variance, and the area of the precipitation curves, thus allowing not only a qualitative comparison of two or more plates but also a quantitation of individual antigens or antibodies.


Assuntos
Anticorpos/análise , Antígenos/análise , Imunoeletroforese Bidimensional/métodos , Imunoeletroforese/métodos , Algoritmos , Alérgenos , Animais , Autoanálise , Cabelo , Cavalos , Humanos , Hipersensibilidade , Imunoglobulina G/análise , Radioimunoensaio/métodos
7.
Scand J Clin Lab Invest ; 54(2): 169-76, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8197404

RESUMO

Blood samples were obtained from 183 blood donors and measured in two hospitals in the same geographical area using identical reference intervals and measuring equipment. The analytical bias of the clinical chemical analyses was investigated through paired measurements. The results showed that out of 15 routine analyses only four meet the goals for acceptance of common reference intervals, of which at least three were of clinical significance. The problems were reflected in the quality assessment results but, nevertheless, no action seems to have been taken.


Assuntos
Análise Química do Sangue/normas , Laboratórios Hospitalares/normas , Adulto , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Valores de Referência
8.
Int J Biomed Comput ; 40(3): 235-40, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8666476

RESUMO

Diagnostic hypercalcaemia discriminant functions, discriminating between clinically significant and non-significant hypercalcaemia, were tested 5 years after their development in order to evaluate the impact of time on their diagnostic capacity. Two populations, consisting of 257 and 129 patients with hypercalcaemia, were consecutively recorded, during six and three months respectively, 5 years apart under similar circumstances. The prevalence of hypercalcaemia was comparable in both populations, being 2.57 and 2.38% respectively (non-significant) (NS). The female/male ratio was 1.9 and 1.7 (NS). The discriminant functions correctly classified 81 and 80% of the women, respectively (NS) and respectively 75% and 64% of the men (NS) in the first and second recorded populations.


Assuntos
Análise Discriminante , Hipercalcemia/etiologia , Hiperparatireoidismo/diagnóstico , Neoplasias/diagnóstico , Adulto , Fosfatase Alcalina/sangue , Creatinina/sangue , Técnicas de Apoio para a Decisão , Feminino , Humanos , Hipercalcemia/sangue , Hiperparatireoidismo/sangue , Masculino , Neoplasias/sangue , Sensibilidade e Especificidade
9.
Biophys J ; 80(3): 1195-209, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11222284

RESUMO

In response to glucose application, beta-cells forming pancreatic islets of Langerhans start bursting oscillations of the membrane potential and intracellular calcium concentration, inducing insulin secretion by the cells. Until recently, it has been assumed that the bursting activity of beta-cells in a single islet of Langerhans is synchronized across the whole islet due to coupling between the cells. However, time delays of several seconds in the activity of distant cells are usually observed in the islets of Langerhans, indicating that electrical/calcium wave propagation through the islets can occur. This work presents both experimental and theoretical evidence for wave propagation in the islets of Langerhans. Experiments with Fura-2 fluorescence monitoring of spatiotemporal calcium dynamics in the islets have clearly shown such wave propagation. Furthermore, numerical simulations of the model describing a cluster of electrically coupled beta-cells have supported our view that the experimentally observed calcium waves are due to electric pulses propagating through the cluster. This point of view is also supported by independent experimental results. Based on the model equations, an approximate analytical expression for the wave velocity is introduced, indicating which parameters can alter the velocity. We point to the possible role of the observed waves as signals controlling the insulin secretion inside the islets of Langerhans, in particular, in the regions that cannot be reached by any external stimuli such as high glucose concentration outside the islets.


Assuntos
Sinalização do Cálcio/fisiologia , Ilhotas Pancreáticas/fisiologia , Modelos Biológicos , Animais , Cálcio/fisiologia , Técnicas In Vitro , Ilhotas Pancreáticas/citologia , Cinética , Matemática , Camundongos , Camundongos Endogâmicos , Microscopia de Fluorescência
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa